• Title/Summary/Keyword: Floor Impact Vibration

Search Result 303, Processing Time 0.032 seconds

Comparison of Panel STLs for Ships Measured in Laboratory and Mock-up (선박용 판넬의 음향투과손실(STL)의 실험실법 측정과 Mock-up 측정값의 비교)

  • Kim, Hyun-Sil;Kim, Bong-Ki;Cha, Sun-Il;Kim, Young-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.69-72
    • /
    • 2005
  • In this paper, FSTL(field sound transmission loss) measured in the mock-up is studied and compared to the STL measured in laboratory. A mock-up is built by using 6t steel plate, and two identical cabins are made where 25t or 50t panel is used to construct wall and ceiling inside the steel structure. Various wall panels and ceilings are tested, where the effects of U/T, sealing, panel thickness, ceilings are studied. It is shown that the effect of ceiling thickness is negligible and FSTL is lower than STL by 5-7 dB due to several flanking paths.

  • PDF

The dynamic stiffness of resilient materials for floor impact sound according to temperature change (온도변화에 따른 바닥충격음 완충재의 동탄성계수 변화)

  • Yeon, Junoh;Goo, Heemo;Lee, Sungchan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.338-342
    • /
    • 2018
  • In order to solve the floor impact sound problem in the upper and lower floors, the Ministry of Land, Transport and Maritime Affairs also notifies the physical properties of the resilient material affecting the floor impact sound level. The dynamic modulus of elasticity and the loss factor before and after heating are most related to the floor impact noise, especially for the cushioning material. Therefore, in this study, the rate of change with respect to the dynamic modulus and loss factor with temperature change was examined by increasing $10^{\circ}C$ by $10^{\circ}C$ from the temperature condition of $70^{\circ}C$ specified in the standard. The dynamic modulus of elasticity and the loss modulus were measured by using the pulse excitation method for eight kinds of samples. The calculation method was calculated by the time series analysis method using the damped vibration waveform.

Numerical Analysis of Heavy-weight Impact Noise for Apartment Units Considering Acoustic Mode (음향모드를 고려한 공동주택 중량충격음 소음해석)

  • Mun, Dae-Ho;Park, Hong-Gun;Hwang, Jae-Seung;Hong, Geon-Ho;Im, Ju-Hyeuk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.7
    • /
    • pp.676-684
    • /
    • 2012
  • Numerical analysis was performed to investigate the heavy-weight impact noise of apartment houses. The FEM is practical method for prediction of low-frequency indoor noise. The results of numerical analysis, the shape of the acoustic modes in room-2 are similar to that of acoustic pressure field at the fundamental frequency of acoustic modes. And the acoustic pressure was amplified at the natural frequency of the acoustic modes and structural modes. The numerical analysis result of sound pressure level at 63 Hz and 125 Hz octave-band center frequency are similar to the test results, but at 250 Hz and 500 Hz have some errors. Considering most of bang-machine force spectrum exists below 100 Hz, the noise at 250 Hz and 500 Hz are not important for heavy-weight impact noise. Thus, the FEM numerical analysis method for heavy-weight impact noise can apply to estimate heavy-weight impact noise for various building systems.

Noise and Vibration Analysis for Net Form Slabs (네트공법 슬라브의 소음 및 진동 해석)

  • Kim, Young-Woo;Kang, Ki-Jun;Jung, Jun-Oh
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.11
    • /
    • pp.1262-1266
    • /
    • 2009
  • The slab(flat) truss plate used for building construction is analyzed for vibration and noise. Using floor impact test and numerical method (FEM), both net form and traditional form are compared for vibration and noise. The results show that the frequencies of a net form are lower than those of a traditional form in the case of free vibration, and the noise values of a net form are lower than those of a traditional form for the range from 500 Hz to 2000 Hz.

Estimation of Dynamic Load of the Utility in Building by TPA Method (TPA 기법을 이용한 건물 내 설비 동하중 산정)

  • Jeong, Min-Ki;Lee, Seong-Soo;Kim, Yong-Ku;Ahn, Sang-Kyung;Lee, Sang-Yeop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.8
    • /
    • pp.773-780
    • /
    • 2009
  • The facility equipments generate dynamic force on building floor and the force can be measured with force transducer. However, this method depends on the measuring capacity or range of sensor, or mounts installation condition of equipments. Because of this restricting condition on force measuring system, this paper suggests a indirect method, the TPA(transfer path analysis) method, that produces a closely approximate dynamic force of equipments. This method calculates the dynamic force by using transfer response function. Firstly, the calculated dynamic force of impact load and continuous load was respectively compared with the sensor-measured value to examine the accuracy of TPA method. After that, the dynamic force and response induced by large facility equipments - a cooling tower, AHU and a large ventilator - were calculated by TPA method and the validity of these value were examined.

Factor Analysis of the Aircraft Noise Impact Assessment in the Building Site Development District Around of Gimpo Airport (김포공항 주변 택지개발지구 항공기소음 영향평가에 미치는 요인분석)

  • Kim, Heung-Sik;Ju, Si-Woong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.6 s.99
    • /
    • pp.718-723
    • /
    • 2005
  • The purpose of this study is to present a fundamental data for evaluating aircraft noise of building site development. By the field experiments and the predicted equal noise level contours using the INM program, actual condition in the building site development arranged district was investigated. In order to get the results, Analysis of factors effected on noise level, sound level on the rate of increase to aircraft demand and difference on the aircraft noise levels according to floor level in apartment house was carried out. As a result the influence of the take-off and landing direction were appeared greatly. The influences of the height at receiving point, movement number of aircraft and increase to aircraft demand were appeared small And the influence of 1 day average WECPNL must be considered.

A study on the capability of inverse A weighting through the auditory perception test (청감실험을 통한 역A특성 평가방법의 타당성 검토)

  • 이성찬;전진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.586-591
    • /
    • 2002
  • Recently, the research and discussion to set up the evaluation standard for nor impact noises in multistory residential buildings has been vividly carried out In Korea. Therefore, the correlation between the methods and auditory responses was investigated through this research to investigate the applicability of the L index evaluation method and the reverse A characteristics evaluation method that are listed in JIS A 1419 since Japanese circumstance are similar to Korean after evaluating the duality of Korean multistory residential buildings. As a result, it was found that the correlation between the value resulted from L index evaluation and the value from reverse A characteristics evaluation is high. In addition, it was also revealed that human responses to each Impacter was similar. Consequently, it is considered th:31 the tendency about the two methods would be similar.

  • PDF

A Study on the Noise and Vibration Reduction Effect Depending on Dynamic Property of Slab (바닥판의 동적특성에 따른 소음진동 저감성능에 관한 연구)

  • 황재승;김선우;송진규;서재란
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.259-266
    • /
    • 2004
  • The vibration of slab causes a sudden change of air pressure in the interface between slab and air to create structure home sound. Floor impact noise induced from the vibration of slab became one of the hottest social issues in these day, and it took the biggest parts of the cause of damage in environmental dispute. Because the structure borne sound of slab is different from the dynamic characteristic of slab, it is required more precise vibroacaustic analysis. In this study, we was trying to understand by what mechanism the slab noise is induced from the slab vibration and the relationship between the dynamic propety of slab and the noise is shown by the numerical simulation.

  • PDF

Perceptual Evaluation of Noise Sources in a Chamber for Residential and Working Environment (주거 및 사무환경 챔버에서의 생활소음에 대한 감성적 평가)

  • Jeon, Jin-Yong;Kim, Kyong-Ho;Jung, Jeong-Ho;Ryu, Jong-Kwan;Cho, Moon-Jae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.6
    • /
    • pp.437-444
    • /
    • 2002
  • This paper is to provide the basic way of a acoustical evaluation and efficient control noise by investigating the limits of perceptual loudness of living environment and by finding out any correlation between Physical characteristics of noise and psychoacoustic parameters. The limits of perceptual loudness were selected by the subjects in a chamber for residential and working environment. And the noise sources were analyzed to find out whether there is any correlation with Zwicker parameters and ACF factors. In this study especially, to set up the domestic evaluation grade about floor impact noise. we'd like to suggest the loudness Perception research result as fundamental resource for setting up the evaluation grade through the result that is based on annoyance. In the result of this research, upper limit of heavy-weight impact noise was L-60, and lower limit of it was L-50. On the other hand, upper limit of light-weight impact noise was L-70, and lower limit of it was L-55. It seemed that the loudness of noise from vacuum cleaner noise does not affect its perceived noisiness. Noises implicated In human such as floor walking noise and talking sound, are the most irritating noise in office environment.

The Selection of the Improved Void Slab Applying the Impedance Method to the Floor-Impact Sound (바닥충격음 임피던스법에 의한 개량형 보이드 슬라브의 선정)

  • Kim, U-Taek;O, Jae-Eung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.12
    • /
    • pp.159-166
    • /
    • 2001
  • Recently, high story apartments are common to solve a housing problem especially in major cities. Apartments are considered as clean, sanitary and convenient to live. However, There are some problems because residents share walls, floors and ceilings with other people. Thus, the residents are often disturbed by neighbours since sound travels the building elements. Especially, impact noise through the floors causes the many complains. And so, it has been drawn attention to isolate by the impact sound. The purpose of this study is to analyze the characteristics of vibration response of 12-type void slabs in the improved void slab by impedance method, and is to find the best improveds void slab on the 12-type void slabs.

  • PDF