• Title/Summary/Keyword: Floor Heating System

Search Result 278, Processing Time 0.022 seconds

Comparative Study on Performance of Wet-type and Dry-type Floor Heating Systems Using Geothermal Heat Pump (지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구)

  • Lee, Byoung-Doo;Lee, Se-Jin;Lee, Dae-Woo;Oh, Sung-Hae;Nam, Woo-Dong
    • New & Renewable Energy
    • /
    • v.5 no.4
    • /
    • pp.60-65
    • /
    • 2009
  • The present study was conducted for a comparative evaluation of wet and dry floor heating systems using geothermal heat pump. We circulated hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.9^{\circ}C$ for wet type and $32.7^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. As a result, in case of floor heating system using low temperature circulation water, dry type was more practicable for stable floor heating than wet type in terms of floor temperature and access time to indoor set temperature.

  • PDF

The Korean under-floor heating system 'ondal' (온돌과 효율)

  • Kim, Ji-Tae
    • Korean Architects
    • /
    • v.3 no.10 s.10
    • /
    • pp.49-53
    • /
    • 1968
  • The heating system, ondol is indispensable for the Korean traditional houses. In the field of architecture today has been made rapid progress in Korea, but it is fact that under-floor heating system in traditional houses in korea has not improved up to now. As a matter of fact, to improve the traditional ondol under present housing structure is very difficult problem. So long as we live in such houses, we architects will have to fulfil our responsibility to improve the ondol system. This article offering data as a basic experiment will be helpful in studing under-floor heating system ondol.

  • PDF

Estimation of the thermal performance on the double slab floor with supplying air (급기가 되는 이중바닥 구조체의 열 성능 평가)

  • Cha, Kwang-Seok;Park, Myung-Sig;Lee, Dae-Woo;Nam, Woo-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.866-871
    • /
    • 2006
  • Recently according to the fashion of well-being, the case study of under floor heating system type for residential space is increasing. Specially double slab floor system can make several roles as reducing the acoustic noises and also supplying fresh air through the gap. So in present study floor heating performance was examined with various location of the space in the case of floor supply air and ceiling supply air. In both cases return air went out through ceiling opening. As one of the result is that when using the heat pipe type floor heating system the temperature difference between supply and return water was $15.2^{\circ}C$, but in case of commercial type floor heating system the temperature difference was $5.3^{\circ}C$ when the supply water temperature was $50^{\circ}C$.

  • PDF

The Comparison of Space Origination between Korean-Chinese and Chinese Multi-family Housing in China (중국 연변 조선족과 한족피 집합주택 평면구성 비교 연구 - 연길시를 중심으로 -)

  • Kim Jong Young
    • Journal of the Korean housing association
    • /
    • v.15 no.4
    • /
    • pp.55-63
    • /
    • 2004
  • The aims of this research are to find the difference of space origination between Korean-Chinese and Chinese multi-family housing unit plan and to find the main reason to make this difference. To do this research, twenty three different kinds of floor plans were surveyed and examined. The results are as follows; 1. The Chinese-Korean floor plan and Chinese floor plan in Ondol heating system are totally different, although in radiator and floor panel heating system are similar. The inner space origination between two races are different. That is to say, Chinese-Korean likes open space origination and Chinese likes closed space origination. 2. The main reasons to make differences seem to be living style, heating system, constructional method and the trade with South Korea. In the future time, the usage of floor panel heating system will be increased and various kinds of floor plan should be introduced.

Performance Evaluation of Air Source Multi Heat Pump Floor Heating System in Apartment (공동주택 공기열 멀티 히트펌프의 바닥난방 성능 평가)

  • LEE, C.H.;Nah, H.S.;JUNG, H.;Kim, K.S.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.93-98
    • /
    • 2011
  • To analyze and evaluate the performance of developing air to water multi heat pump, the heat pump was installed and tested at low energy house in Daejeon, korea. Heating capacity of heat pump is 16.5KW and cooling capacity is 14.0KW. Space heating/cooling, floor heating and hot water is available. The results performance evaluation of heat pump in lab test showed that the coefficient of performance (cop) was 3.75, and heating capacity was 16.0KW in ambient temperature $7^{\circ}C$. Also at ambient temperature $-15^{\circ}C$, the COP was 1.69. At a low energy house, floor heating is controled by a floor heating water temperature and a room temperature. The COP of heat pump is decreased with frequent on/off operation for controlling of floor heating water temperature.

A review on the effect of a floor heating system on the human body (기존문헌조사에 의한 바닥난방의 인체영향에 관한 연구)

  • 최영식
    • Journal of the Korean housing association
    • /
    • v.3 no.1
    • /
    • pp.85-92
    • /
    • 1992
  • A floor system have played a major part in the living in Korean house. It is an essential element in the residential houses. Uufortunately, a design method of the floor heating system for the human thereat comfort has not established in Korea system. This paper aims to review the previous researches to find the issue for the futher study of comfort floor heating design. The following results were obtained: 1) Nevins et at conducted experiments on the effect of the comfortable of floor and air temperatures on the psychological responses by a large number of subjects. Its objective was to find the combined condition to obtain thermal comfort for sedentary posture.7here has never been researches regarding a sitting Person on the heated floor. 2) Some investigation in Japan on the effect of floor heating system on a sitting person on the floor have been conducted for these years, but they are net based on the human heat balance but on only psychological responses. 3) Hirayama et al developed an indication method of the effect of heat conduction on the sedentary person.4) There are few researches on the human thermal comfort compared whth indoor environmental researches on mechanical controls in Korea. Thus, the further study on the followings in needed the estimaiing of heat conduction between tile hunman body and a floor, developing an index expressed the combined effect of convection, radiation and conduction and its associated experiments.

  • PDF

Thermal performance prediction of amorphous steel fibers mixed into the floor heating system (비정질 강섬유 혼입 바닥난방시스템의 열성능 평가)

  • Cho, Hyun;Pang, Seung-Ki
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.130-135
    • /
    • 2016
  • The thermal performance of amorphous steel fibers mixed floor heating system was evaluated. Analysis of results, depending on the hot water supply temperature changes, the average temperature of the bottom of the hot water supply temperature is an amorphous steel fiber floor heating system is about 2~4% higher. The average temperature of the floor surface to 1.5m air amorphous steel fiber system is 1~2% higher. The amount of heat supplied to indoor air (1.5m) from the bottom surface of amorphous steel fiber floor heating system is about 7~8% higher

An Experimental Study on Two Parameter Control for Radiant Floor Heating System

  • Cho, Sung-Hwan;Tae, Choon-Seob;Jang, Chel-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.136-147
    • /
    • 1998
  • An experimental facility consisting of two 3$\times$4.4$\times$2.8m rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparison of two different control strategies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study: (ⅰ) conventional on-off control based on feedback from room air temperature (ⅱ) TPSC(two parameter switching control )(ⅲ) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

Energy Performance Analysis Program with Heating methods of Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방용 자동온도조절기의 난방방식에 따른 에너지성능 해석용 프로그램에 관한 연구)

  • Ahn, Byung-Cheon;Song, Jae-Yeob;Lee, Tae-Won;Kim, Yong-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.381-386
    • /
    • 2008
  • In this study, the energy characteristic of automatic thermostatic valves according to each heating method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on heating method, valve's control method, outdoor air condition, supply heating water temperature, supply flow rate are performed to compare energy characteristic, respectively.

  • PDF

A Study of Flow Characteristics through the Speed Control and Flow Resistance (유로저항에따른 속도제어를 통한 Zone별 유량특성 연구)

  • Oh, Byung-Kil;Kim, Hway-Suh
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.762-768
    • /
    • 2011
  • We use floor radiant heating system in the house of commons in winter Floor radiant heating system, which transfer heat by radiation, is one of the energy efficient and comfortable systems that. Floor radiant heating system is configured to be controlled by the room for energy-saving. Proper flow rate to a comfortable heating in the room is important. However, Using a constant speed circulation pump in separate rooms, heating system may cause an imbalance because of the difference of length of coil when operating in the rooms. In this study, our Research team examined heating imbalance due to the variation length through the coil length changes and flow control of the circulation pump.