• Title/Summary/Keyword: Floor

Search Result 6,097, Processing Time 0.041 seconds

Study on the Utilization of Sawdust Bedding Barn for Dairy Cows (착유우의 톱밥발효우사 이용연구 제 1 보 : 낙농가의 톱밥발효우사 형태별 이용효과 비교)

  • Kweon, Du-Jung;Kweon, Ung-Gi;Ki, Wang-Seok;Lee, Kee-Jong;Han, Jeong-Dae;Jung, Suk-Chan;Kang, Seung-Won;Kang, Sang-Lyol;Jung, Hyoung-Sup;Chang, Hak-Joo
    • Journal of Animal Environmental Science
    • /
    • v.1 no.1
    • /
    • pp.9-19
    • /
    • 1995
  • This study was carried out to investigate the effect of sawdust bedding barn on manure handing, management labour and physiological aspect of dairy cows, and then to establish the criteria on the optimum utilization method of sawdust bedding barn. 46 tie stall barns and 49 sawdust bedding barns were surveyed to cmopare the milk productivity between two different barns, and also 5 tie stall barns, 15 sawdust bedding barns and 1 rice hull bedding barn were selected to study the utilization situation of sawdust barn in Kyung-Ki province area. The major results obtained were as follows; 1. The roof material of sawdust barn were consisted of 66% vinyl house, 23% PVC light and 11% slate and galvanum coated tin. Most of the floor structure was earth ground with the rate of the approximately 82%. 2. The average occupied area of sawdust bed per cow was 15.2 $m^2$, depth that 30 cm and the utilization period was 12 months. 3. Milk Yield was significantly higher at sawdust barn than at tie stall barn(P<0.01). Bacterial and somatic cell count in raw milk were less at the sawdust barn than in tie stall barn. However, there was not significance difference between two barns. 4. The labour hour needed to cow management in the sawdust barn was approximately 48% of that of tie stall barn. 5. The temperature and moisture content measured in sawdust bed were closely affected by seasonal ambient temperature. The skin and hair of cow were much cleaner at the PVC light roofed sawdust barn than any other roof materials. 6. The additives used for improving of fermentation did not show any effect on temperature and moisture content in sawdust bed. When the ambient temperature was $30.4^{\circ}C$, the surface temperature of measured 1 cm above the sawdust bed was $12.2^{\circ}C$ lower and the temperature of 100 cm above the sawdust bed was $2.4^{\circ}C lower under shading net facility than that of vinyl roofed one.7. The hoof length of miking cow was 7.95 cm in tie stall and 9.19 cm in sawdust barn with high significance (P<0.01). And disease occurence such as mastitis and foot-rot tended to decrease in the sawdust barn. 8. The number of total bacteria and coliform bacteria were less in the sawdust bed compared with earth ground resting area. And a parasite strongyloides papillosus was detected but without any infected cow. 9. The nitrate($NO_3N$) content in non-roofed earth ground resting area and earth ground under the sawdust bed was likely to pollute the ground water. 10. In economic point of view, rice hull bedding barn was the cheapest among different systems. And in the sawdust bedding barn PVC light + slate roofed barn was most desirable, and vinyl roofed one the least.

  • PDF

Evaluating the Visual Contrast Rating of the Landscape Impact Factors - A case study for the Buildings in Natural Landscape - (경관영향 요소별 경관 대비성 평가 - 자연경관에 도입되는 건축물을 중심으로 -)

  • Choi, Won-Bin;Shin, Ji-Hoon
    • Journal of Korean Society of Rural Planning
    • /
    • v.24 no.3
    • /
    • pp.87-96
    • /
    • 2018
  • While cities became bigger and bigger since 1990s, many indiscretely high buildings started to be built in the mountain areas inside a city and in the rural areas in the suburb of each city. To regulate such indiscrete developments, the government prepared for some relevant legal and institutional criteria by having enacted the "Landscape Act" and established a strong management means in the legal and institutional aspects by having introduced the natural landscape deliberation system and the landscape deliberation one into the "Natural Environment Conservation Act." However, since some uniform levels of absolute height and no. of stories are suggested legally and institutionally, it is hard to consider the effects of a real building structure onto the relevant landscape. Accordingly, this thesis is intended to grasp the contrast of the landscape elements in the allowable height section, which is presented through landscape sensitivity. As the results from the visual contrast rating on a small apartment complex located in Dangjin and a large scale of apartment complex in Seosan as the apartment complexes surrounded with natural landscapes that were selected as the subjects of this study, the following conclusion can be finalized. First, there were deducted some factors, that is, forms, lines, colors, textures and sizes as the ones with which can measure and evaluate the contrasting properties when a structure gets into a natural landscape. Second, in case of a small scale of apartment complex (in the foreground) compared to a large one (in the foreground), it was found that the contrasting properties were bigger. In addition, it was also found that the contrasting property of the landscape factor of the foreground compared to that of the middle one becomes bigger depending on a distance. Third, as the results from an evaluation on the contrasting properties of the landscape factor depending on the changes of each floor of a structure, it was found that the factors, that is, forms, lines, colors, textures and sizes are very significant. Among those factors, the factors, forms and lines in a small scale of apartment complex (in the foreground) showed each log regression. But in all of the other cases, they showed each line regression. Fourth, as the results from examining the regression coefficients of the landscape factor, the coefficients of the shapes and lines have similar coefficients and the colors and the textures have similar ones, too. In case of the sizes of apartment complexes, the colors and the textures of a large apartment complex (in the foreground) have similar coefficients, in case of that in the middle ground, the shapes and lines have similar coefficients. Fifth, as the results from estimating the contrasting properties of the landscape factor on the floors within the allowed scope of the landscape sensitivity, it was found that the contrasting property was 3.5 to 4.9 in case of a small scale of apartment complex (in the foreground), but 2.5to 3.7 in case of a small scale of one. In case of a large scale of apartment complex, the value was 3.5 to 5.3, but in case of a large one in the middle ground was 2.9 to 4.9. Sixth, it was comprehended that the contrasting properties of the landscape factor become different depending on each size of apartment complex and the distance of a view point. In this study, it is intended to find the meaning from the aspect that the results can be used as the baseline data for comprehending a proper range of heights of structures objectively during a natural landscape deliberation or a landscape deliberation.

Radiotherapy for Oral Cavity Cancer (구강암의 방사선치료)

  • Shim Jae Won;Yoo Seong Yul;Koh Kyoung Hwan;Cho Chul Koo;Yun Hyong Geun;Kim Jae Young
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.267-275
    • /
    • 1993
  • Eighty five patients of oral cavity cancer, treated with radiation at the Department of Therapeutic Radiology, Korea Cancer Center Hospital, during the period from March 1985 to September 1990 were analyzed retrospectively. Among 85 patients, 37 patients were treated with radiation only and 48 patients were treated with radiation following surgery. And 70 patients received external irradiation only by $^{60}Co$ with or without electron, the others were 7 patients for external irradiation plus interstitial implantation and 8 patients for external irradiation plus oral cone electron therapy. Primary sites were mobile tongue for 40 patients, mouth floor for 17 patients, palate for 12 patients, gingiva including retromolar trigone for 10 patients, buccal mucosa for 5 patients, and lip for 1 patient. According to pathologic classification, squamous cell carcinoma was the most common (77 patients). According to AJC TNM stage, stage I + II were 28 patients and stage III+IV were 57 patients. Acturial overall survival rate at 3 years was $43.9\%,$ 3 year survival rates were $60.9\%$ for stage I + II, and $23.1\%$ for stage III+IV, respectively. As a prognostic factor, primary T stage was a significant factor (p<0.01). The others, age, location, lymph node metastasis, surgery, radiation dose, and cell differentiation were not statistically significant. Among those factors, radiation plus surgery was more effective than radiation only in T3+T4 or in any N stage although it was not statistically sufficient (p<0.1). From those results, it was conclusive that definitive radiotherapy was more effective than surgery especially In the view of pertainig of anatomical integrity and function in early stage, and radiation plus surgery was considered to be better therapeutic tool in advanced stage.

  • PDF

Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground (지하에 위치한 방사선종양학과에서의 실내공기 질 평가)

  • Kim, Won-Taek;Shin, Yong-Chul;Kang, Dong-Mug;Ki, Yong-Kan;Kim, Dong-Won;Kwon, Byung-Hyun
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.243-252
    • /
    • 2005
  • Purpose: Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. this study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Methods and Materials : Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate. carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor all quality, All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Results: Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritatation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the contaminated-air circulation immediately Conclusion We verified that some IAQ-related factors and inadequate ventilating system could cause subjective symptoms in hospital workers. The evaluation of IAQ was surely needed to improve the underground working environments for hospital workers and patients. On the basis of these data, from now on, we should actively engage in designs of the department of radiation oncology or improvement in environments of the existing facilities.

Differences among Major Rice Cultivars in Tensile Strength and Shattering of Grains during Ripening and Field Loss of Grains (벼알의 인장강도 및 탈립성의 등숙중 변화와 품종간 차이 및 포장손실과의 관계)

  • Y. W. Kwon;J. C. Shin;C. J. Chung
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 1982
  • Degree of grain shattering which is of varietal character is an important determinant for the magnitude of field loss of grains during harvest and threshing. Seven Indica \times Japonica progeny varieties and four Japonica varieties were subjected to measurements of tensile strength of grains, degree of grain shattering when panicles were dropped at 1.5m above concrete floor, and moisture content of grains (wet basis) during a period 35 to 63 days after heading. In addition, two varieties were tested for the relation of tensile strength of grains to the magnitude of field loss of grains in actual binder harvest. The 11 varieties differed conspicuously in tensile strength of grains and the degree of grain shattering: the weakest average tensile strength of grains of a variety was about 90g and the strongest about 250g with varying standard deviation of 30 to 60g. Three Indica \times Japonica varieties and one Japonica variety shattered I to 30% of the grains under the falling test. The threshold tensile strength of grains allowing grain shattering was estimated to be 180g on average for a sampling unit of 10 panicles, but only the grains having tensile strength weaker than 98g within the samples shattered. A decrease in average tensile strength by 10g below the threshold value corresponded to an increase of 3 to 5% in grain shattering. Most varieties did not change appreciably the tensile strength of grains and degree of grain shattering with delay in time of harvest and showed a negative correlation between the tensile strength and the moisture content of grains. The average tensile strength of grains was negatively correlated linearly with field loss in binder harvest. The average tensile strength for zero field loss in binder harvest was estimated to be 174g and a decrease in the average tensile strength by 10g corresponded to an increase of 40kg per hectare in field loss of grains. Instead of the average tensile strength of grains, the percentage of grains having tensile strength weaker than 100g is recommended as a criterion for the estimation of field loss of grains during harvesting operations as well as a basis of variety classification for grain shattering, since the standard deviation of tensile strength of grains varies much with variety and time of harvest, and individual grains having tensile strength stronger than 98 did not shatter practically.

  • PDF

A study on measures for the mitigation of fire damage in Korea super high-rise building through the improvement of domestic·foreign standards (국·내외 기준개선을 통한 국내 초고층 건축물의 화재피해경감 대책에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.233-248
    • /
    • 2017
  • Uniform laws and regulations and reasonable design is necessary for the prevention of possible fire in super high-rise building. To this end, this study focused on super high-rise and massive building-related architectural review performance-based design (PBD) evaluation disaster impact assessment (DIA), and provided fire engineering measures for improving fire prevention on the basis of performance-based design by analyzing the buildings subject to these systems and problems in terms of contents. Above all, in the aspect of law and standard improvement, first, with regard to dual parts of two statutes though significant portion of them has the same contents in performance-based design (PBD) evaluation and disaster impact assessment (DIA), it is necessary to operate the systems after making them conform with each other and consolidating or abolishing them. Second, if it is impossible to consolidate or abolish performance-based design (PBD) evaluation and disaster impact assessment (DIA), the areas of contents of performance-based design (PBD) evaluation and disaster impact assessment (DIA) should be precisely classified and established. Next, engineering improvement measures against fire hazard in super high-rise building are as follows. First, it is necessary to revise the provisions of straight-run stairs in special escape stairs. And in case of installing a mechanical smoke exhaust system instead of smoke vent, sandwich pressurization used in the United Stated should be permitted. Second, with regard to smoke control system for special escape stairs, it was shown that there was necessity for revising the standards in order to enable air to be supplied according to section in case of fire, carrying out performance-based design, and the like from the early design stages to the completion stages. In the future, it is expected that an epoch-making contribution will be made to a decrease in casualties and property damage due to fire in case of super high-rise building where the results can be reflected after carrying out a study on maintenance and carrying out an additional study on other considerations of super high-rise building together with reflecting the improvement measures provided in the above-mentioned study.

Effects of Herbal Product (Miracle®) on the Performance, Nutrient Digestibility, Fecal Microflora and Immunoresponse in Weanling Pigs (생약제제(미라클®)첨가가 이유 자돈의 성장률, 영양소 이용율, 분내 미생물균총 및 면역기능에 미치는 영향)

  • Suk, J.C.;Lim , H.S.;Paik, I.K.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.767-776
    • /
    • 2003
  • An experiment was conducted to investigate the effects of dietary herbal product(Miracle$^{\circledR}$) supplementation on the performance, nutrient digestibility, fecal microflora and blood parameters in pigs. Forty eight cross bred(Y${\times}$L${\times}$D) weanling pigs (average initial body weight 7.84kg${\pm}$0.17, 28 d old) were used in 35 d feeding trial. Pigs were allotted to 16 raised floor cages(W 35.5cm${\times}$L45cm${\times}$H 55cm). Each treatment had four replications of 3 pigs each. Treatments were: control (T1), CTC 100ppm (T2), Miracle$^{\circledR}$ 0.15% (T3) and CTC 100ppm + Miracle$^{\circledR}$ 0.15% (T4). The herbal product supplementation(T3) tended to improve the weight gain, feed intake, feed/gain but there were no significant differences among treatments. Nutrient digestibility was significantly(P〈0.05) affected by dietary treatments. The pigs fed T3 diet showed the lowest digestibility of DM, crude protein, NFE, P, and amino acids among treatments. Serum cholesterol level of pigs fed T3 diet was lowest and significantly(P〈0.05) lower than those fed antibiotic supplemented diet(T2). Triglyceride and HDL level of the pigs fed T3 diet were also lower than those of others but the differences were not significant. The level of serum IgG was significantly(P〈0.05) different among treatments. The level of serum IgG was highest in T4, followed by T1, T2 and T3. Serum AST(Aspartate aminotransferase) level of the control(T1) was lower than other treatments. Levels of serum total protein, albumin and ALT(Alanine aminotransferase) were not significantly different among treatments. The colony forming units (CFU) of Lactobacillus, Cl. perfringens and E.coli in feces were not significantly different among treatments but those of Cl. perfringens of T2 (CTC 100ppm) showed the lowest count at both 3rd and 5th wk. It is concluded that herbal product Miracle$^{\circledR}$ does not significantly affect growth performance of weanling pigs but it influenced the digestibility, serum IgG, cholesterol and AST level. The combination of the herbal product Miracle$^{\circledR}$ with antibiotic(CTC) showed no synergistic effects.

The Development of a Model for Selecting Method of Entry for Apartment in Remodeling an Underground Parking Lot (지하주차장 리모델링 공사시 주동진입방법 선정 모델 개발)

  • Song, Nak-Hyun;Jung, In-Su;Lee, Chan-Sik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.2
    • /
    • pp.65-74
    • /
    • 2009
  • It is expected that the number of apartment complexes in Korea that are over 20 years old will rapidly increase to more than 3,500,000. Consequently, the remodeling of these buildings is being revitalized throughout the country. Among the requirements for such remodeling, the expansion of parking lots has considerable weight. When enlarging a parking lot, the access route from an underground floor to the main building (i.e., the means of entry into the main building) determines the possibility of vertical enlargement for elevators, the size of the parking lot, the construction period, and construction expenses, etc. When enlarging an underground parking lot of an apartment complex, the access between the main building and the parking lot, as well as the inhabitants' requirements for entering the main building, are generally determined based on the designer's experience, rather than on the exact estimation of the peculiarity of the complex. In order to resolve such a problem, when enlarging an underground parking lot, a systematic and rational method is needed for selecting the means of entry into the main building. In this study, a selection model is derived for the method of selecting an access route into the main building when constructing an underground parking lot, in order to provide a reasonable decision-making process. A research method was investigated for determining the access route into the main building when enlarging a parking lot. On the basis of research carried out through in-depth interviews with experts, the characteristics for each means of entry into the main building were analyzed and the factors affecting the selection of the access route were deduced. The affecting factors selected were construction efficiency, convenience efficiency and economic efficiency. Weight values were then estimated for the selected affecting factors by applying the AHP method. Results showed that convenience efficiency, which gained the highest value, is the most important factor in selecting the means of entry into the main building. The most suitable means of entry into the main building was also suggested after estimating the applicability of the site by selecting complexes with remodeling possibility. This study will be applied as a reference for selecting the means of entry into the main building when constructing an underground parking lot particularly for older apartment complexes.

Surface roughness analysis of ceramic bracket slots using atomic force microscope (원자현미경을 이용한 세라믹 브라켓 슬롯의 표면조도에 대한 연구)

  • Park, Ki-Ho;Yoon, Hyun-Joo;Kim, Su-Jung;Lee, Gi-Ja;Park, Hun-Kuk;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.40 no.5
    • /
    • pp.294-303
    • /
    • 2010
  • Objective: This study was designed to measure the surface roughness at the slot floor of various ceramic brackets. Methods: One kind of stainless steel bracket ($Succes^{(R)}$), two kinds of monocrystalline brackets (Inspire $Ice^{(R)}$, $Perfect^{(R)}$) and two kinds of polycrystalline brackets (Crystalline $V^{(R)}$, $Invu^{(R)}$) were examined. Atomic force microscopy (AFM) was used to measure the surface roughness of each bracket. Data acquisition and processing were performed using $SPIP^{TM}$. Results: The differences in values of Sa, Sq, and Sz in $Invu^{(R)}$ and Inspire $Ice^{(R)}$ were not statistically different from the control group $Succes^{(R)}$. The values of Sa, Sq, and Sz of $Perfect^{(R)}$ and Crystalline $V^{(R)}$ were greater than those of $Succes^{(R)}$. Differences of all the Sa, Sq, and Sz values between $Perfect^{(R)}$ and Crystalline $V^{(R)}$ were not statistically significant. Conclusions: It is concluded that the slot surfaces of $Succes^{(R)}$, Inspire $Ice^{(R)}$, and $Invu^{(R)}$ were smooth compared to those of Crystalline $V^{(R)}$ and $Perfect^{(R)}$.

A Study on The Introduction of LID Prior Consultation for Small-Scale Development Projects - Focusing on Cost-Benefit Analysis - (소규모 개발사업의 저영향개발(LID) 사전협의 제도 도입 연구 - 비용편익 분석을 중심으로 -)

  • Ji, Min-Kyu;Sagong, Hee;Joo, Yong-Jun
    • Clean Technology
    • /
    • v.26 no.2
    • /
    • pp.151-157
    • /
    • 2020
  • Rapid urbanization has elevated the risk of urban flooding due to the increase in the impervious surface, causing environmental disasters and environmental pollution problems, such as lowering the groundwater level and increasing water pollution. In Korea, low impact development (LID) techniques have been introduced to minimize these environmental impacts and maintain the water cycle soundness. However, most small-scale development projects are in blind spots because there is no legal basis for rainfall runoff management. Small-scale development projects that increase the surface runoff of rainwater are required to mandate the application of LID facilities in accordance with the polluters' responsibility principle. Therefore, it is necessary to implement a preliminary consultation system for water cycle recovery. This study focuses on the cost-benefit analysis on the application of LID techniques for small-scale development projects. The scale of nationwide small-scale development projects used for cost-benefit analysis were defined as buildings with a land area of more than 1,000 ㎡ or a total floor area of 1,500 ㎡. As a result of analyzing the cost-benefits from the installation of LID facilities, they were found to be much lower than the economic standard value of 1. This might be due to the high cost of facilities compared to the scale of the project. However, considering the overall environmental value of improving the water environment and air quality by the installation of LID facilities and the publicity of reducing the operating cost of sewage treatment facilities, the introduction of a prior consultation for small-scale development projects is inevitable. In the future, institutional and financial support from local governments is required to improve the cost-benefits with the introduction of a prior consultation for small-scale development projects.