• Title/Summary/Keyword: Flood disaster

Search Result 620, Processing Time 0.029 seconds

Estimating Critical Stream Power by the Distribution of Gravel-bed Materials in the Meandering River (만곡하천의 자갈하상재료 분포에 따른 한계수류력 평가)

  • Shin, Seung-Sook;Park, Sang-Deok;Lee, Seung-Kyu;Ji, Min-Gyu
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.2
    • /
    • pp.151-163
    • /
    • 2012
  • The distribution of gravel-bed materials in mountainous river is formed by the process of deposition and transportation of sediment responding to stream power of the latest flood that is over the certain scale. The particle size of bed material was surveyed in the longitudinal points of river and detail points of a specific meandering section and used to estimate the critical velocity and stream power. Yang's critical unit stream power and Bagnold's critical stream power for gravel-bed materials increased with the distance from downstream to upstream. Dimensionless shear stress based on the designed flood discharge in Shields diagram was evaluated that the gravel-bed materials in most survey points may be transported as form of bedload. The mean diameter in the meandering section was the biggest size in first water impingement point of inflow water from upstream and the second big size in second water impingement point by reflection flow. The mean diameters were relatively the small sizes in points right after water impingement. The range of mean critical velocity was 0.77~2.60 m/s and critical unit stream power was big greatly in first water impingement point. The distribution of critical stream power, range of 7~171 $W/m^2$, was shown that variation in longitudinal section was more obvious than that of cross section and estimated that critical stream power may be affected greatly in first and second water impingement point.

A Study on Determination of Capacity for Pump and Detention Pond in Small Basins for Flood Control (소유역에서 홍수조절용 펌프 및 유수지 규모의 결정에 관한 연구)

  • Ahn, Tae-Jin;Park, Jong-Yoon;Lyu, Heui-Jeong;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.3 s.134
    • /
    • pp.385-398
    • /
    • 2003
  • The concept of the effective storage ratio has been suggested to determine the size of detention pond by the previous researchers. The 11 pump - pond facilities in Dongdu-chun city were selected to analyze the critical duration for design rainfall and the storage ratio for each rainfall duration in this study It has been then found that the criteria of the maximum storage ratio is not reasonable for determining the size of detention pond because the difference of storage ratio with respect to each rainfall duration is too small. Moreover, since the size of pond compared with the pump capacity is not always big enough, the pump should be frequently operated, which may result in pump failure. Thus, the pond should be sufficiently sized to prevent the possibility of the pump failure due to frequent operation. According to the analyses for changing pump capacity, it has been found that if the function of the pond compared with the pump is concentrated, determining the size of pond based on the storage ratio is operationally feasible for even small basin. Thus, an improved procedure based on the storage ratio for determining the size of detention pond in small basin has been suggested. The results by the proposed procedure considering pump switching frequency may lead to reasonable pump operation. A simple linear programming model has been also adopted to figure out the relationship between pump capacity and pond size. It has been shown that the determination lot the size of detention pond based on conventional hydrologic flood routing in pond is feasible for only urban districts not rural areas.

A Study on the Improvement of Huff's Method for Applying in Korea : II. Improvement of Huff's Method (Huff 강우시간분포방법의 개선방안 연구 : II. Huff 방법의 개선방안)

  • Jang Su-Hyung;Yoon Jae-Young;Yoon Yong-Nam
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.9 s.170
    • /
    • pp.779-786
    • /
    • 2006
  • In this study, we propose a new method that utilizes rainfall data in and out of a basin, which is greater than 25.4mm for point rainfall or 12.7mm for areal mean rainfall respectively. From our analysis, most frequent quartile for point and areal mean rainfall were found to be the same in general for various rainfall duration intervals. From an evaluation of design rainfall per each rainfall duration distributed in time by the MOCT(Ministry of Construction and Transportation) version of Huff's method and this study, peak rainfall intensity by this study was found to be greater than the one by MOCT, but there were no consistent increase or decrease of this difference with rainfall durations. Using the distributed design rainfall per each duration by MOCT and this study, corresponding flood inflow hydrographs were simulated and compared each other. Contrary to the case of peak rainfall intensity, difference in peak flow by both methods per each rainfall duration started to increase from about 12-hr duration. Especially, the difference in peak flow was significant when critical rainfall duration was considered, and this trend was similar for peak flows of other rainfall durations. Therefore, the method proposed in this study is thought to be the effective procedure for the construction of dimensionless cumulative rainfall curve that is representative of a basin while considering time distribution characteristics for different rainfall durations.

Analysis on Rainwater Harvesting System as a Source of Non-Potable Water for Flood Mitigation in Metro Manila (마닐라의 홍수저감을 위한 잡용수 대체자원으로서의 가정용우수저류시설 분석)

  • Necesito, Imee V.;Felix, Micah Lourdes A.;Kim, Lee-Hyung;Cheong, Tae Sung;Jeong, Sangman
    • Journal of Wetlands Research
    • /
    • v.15 no.2
    • /
    • pp.223-231
    • /
    • 2013
  • Excessive precipitation, drought, heat waves, strong typhoons and rising sea levels are just some of the common indicators of climate change. In the Philippines, excessive precipitation never failed to devastate and drown the streets of Metro Manila, a highly urbanized and flood-prone area; such problems are expected to occur frequently. Moreover, the water supply of Metro Manila is dependent only to Angat Reservoir. Rainwater harvesting can serve as an alternative source of raw water and it can mitigate the effects of flooding. The harvested rainwater can be used for: potable consumption if filtered and disinfected; and non-potable consumptions (e.g., irrigation, flushing toilets, carwash, gardening, etc.) if used untreated. The rainfall data were gathered from all 5 rainfall stations located in Metro Manila namely: Science Garden, Port Area, Polo, Nangka and Napindan rain gauge stations. To be able to determine the potential volume of rainwater harvested and the potentiality of rainwater harvesting system as an alternate source of raw water; in this study, three different climatic conditions were considered, the dry, median and wet rainfall years. The frequent occurrence of cyclonic events in the Philippines brought significant amount of rainwater that causes flooding in the highly urbanized region of Metro Manila. Based from the results of this study, the utilization of rainwater harvesting system can serve as an alternative source of non-potable water for the community; and could also reduce the amount of surface runoff that could result to extreme flooding.

Analysis on Effect of Construction Facilities depending on a Scenario of Sea Level Rise around Jeju Coastal Area (해수면 상승 시나리오에 따른 제주연안지역 건설시설물의 영향 분석)

  • Lee, Dong Wook;Bu, Yang Su
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2D
    • /
    • pp.267-274
    • /
    • 2011
  • In this study, around Jeju area where climatic change is most considerably appearing in Han Peninsula, we prepared sea level rise height caused by sea level rise (Seogwipo 5.6 mm/yr, Jeju 5.3 mm/yr) and a sea level rise scenario for the case when an enlarged typhoon attacks during high water ordinary spring tide, and evaluated flooding area and effect on road and facility using Digital Elevation Model(DEM) and GIS Spatial Analysis Technique. As a result, the flooding areas were shown to be 2.9 $km^2$ in 2040, 5.4 $km^2$ in 2070, and maximum 5.4 $km^2$ in 2100. Analyzing the effect of flooding on each type of road, the local roads(Gun-do) were shown to be mostly affected. The most flood effected facilities were individual houses. Especially, as there is a possibility for casualties to occur due to disaster in Hwabuk-dong because the effect of flooding on individual houses in this area was shown to be high. In addition, flood on port facilities will considerably affect logistic and marine activities. This study is thought to be a basic data which can be utilized for establishment of strategic coping measures and policies of government affiliated organizations through analysis of effect of sea level rise on construction field.

Urban Runoff According to Rainfall Observation Locations (강우 측정 지점에 따른 도시 유역 유출량 변화 분석)

  • Hyun, Jung Hoon;Chung, Gunhui
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.305-311
    • /
    • 2019
  • Recently, global climate change causes abnormal weather and disaster countermeasures do not provide sufficient defense and mitigation because they were established according to the historical climate condition. Repeated torrential rains, in particular, are causing damage even in the robust urban flood defense system. Therefore, in this study, the change of runoff considering the spatial distribution of rainfall and urban characteristics was analyzed. For rainfall concentrated in small catchment, rainfall in the watershed must be accurately measured. This study is based on the rainfall data observed with Automated Surface Observing System (ASOS) and Automatic Weather Stations (AWS) provided by the Seoul Meteorological Administration. Effluent from the pumping station was estimated using the EPA-SWMM model and compared and analyzed. Catchments with rainwater pumping station are small with large portion of impermeable areas. Thus, when the ASOS data where is located from from the chatchment, runoff is often calculated using rainfall data that is different from rainfall in the catchment. In this study, the difference between rainfall data observed in the AWS near the catchment and ASOS away from the catchment was calculated. It was found that accurate rainfall should be used to operate rainwater pumping stations or forecast urban flooding floods. In addition, the results of this study may be helpful for estimating design rainfall and runoff calculation.

Estimation of Daily Sewage and Direct Runoff for the Combined Sewer System of Gunja Experimental Drainage (군자 시험배수구역 합류식 하수관거시스템의 일일하수량 및 직접유출량 산정)

  • Kim, Chung-Soo;Han, Myoung-Sun;Kim, Hyoung-Seop
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.3
    • /
    • pp.191-200
    • /
    • 2009
  • A localized torrential rainfall and flash floods which are more frequently occurred by extraordinary atmospheric phenomena and rising sea surface temperature require more hydrological data collecting and analysis for small watershed. Urban watershed hydrological data monitoring system is needed because of big flood potential damage and lack of urban watershed hydrological data. Therefore, Urban Flood Disaster Management Research Center operates small experimental catchments(Sinnae1, Gunja, and Children's Park) observing and analyzing hydrological data(rainfall, stage, and discharge). In this study, the discharge of combined sewage for Gunja experimental drainage is analyzed with weekly data and day of the week data. Through several analyses in analyzing the urban runoff characteristics and managing the urban sewage system, direct runoff is calibrated and verified by the estimated values of rainfall-runoff model(SWMM).

A Study on the Management Method of Agricultural reservoir Using RCP Scenario (RCP 시나리오 분석을 통한 농업용 저수지 관리방안에 관한 연구)

  • Choo, Yeon Moon;Won, Chang Hee;Kim, Seong Ryul;Gwon, Chang Heon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.28-34
    • /
    • 2020
  • A reservoir is defined as an artificial facility that stores and controls water during floods and droughts. Korea has constructed and managed reservoirs all over the country to benefit farming communities. The importance of reservoirs has decreased gradually due to urbanization and the spread of tap water, but the importance of water is increasing because of the recent shortage of water and the resulting rise in the price of water resources. Therefore, this study suggests countermeasures through an analysis of the used threshold for agricultural reservoirs. To this end, the forecast of rainfall up to 2100 was first analyzed using flood estimates and RCP scenarios through rainwater data collection. The increase in the RCP 8.5 scenario, the largest increase in the probability rainfall, was calculated by adding it to the current probability rainfall, and it was predicted that the marginal height of Odong Dam would reach its limit in 2028. Therefore, as a countermeasure against this, the measures to secure effective water storage were suggested through measures, such as lowering the height of Yeosu and installing movable beams. Overall, it is expected that effective management of the reservoirs used for agriculture will be possible in the future.

Effects of the water level reduction and the flow distribution according to change of the side weir location in detention reservoir (홍수조절지 횡월류위어의 위치 변화에 따른 수위 저감 및 유량 분담 효과)

  • Seong, Hoje;Park, Inhwan;Rhee, Dong Sop
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.7
    • /
    • pp.555-564
    • /
    • 2018
  • The detention reservoir is a hydraulic structure that constructs a levee on the inland of river and sets up side weir in a section of the levee, and this facility stores a part of the flood volume in case of a flood event over a certain scale. In order to optimize the operation of detention reservoir, it is necessary to review the linkage with existing facilities in the river. In this study, the effect of water level reduction and the flow distribution was analyzed according to the location of the side weir in the detention reservoir considering the run-of-the-river gate. Two radial gates were installed in the experimental channel, and the water level in channel and the overflow of weir were measured by moving the location of the side weir upstream from the gate. As a results of experiment, it was confirmed that the water level reduction is more remarkable as the location of the side weir was closer to the gate, and the effect of flow distribution is not greatly changed. When two or more side weirs were operated, it is confirmed that the sufficient storage space was secured and the water level reduction effect with the location of the side weir is not large. In addition, the water level reduction rate according to the location of the side weir was estimated by empirical formula and it is provided as basic data that can be used in the planning of the detention reservoir.

Determination of operating offline detention reservoir considering system resilience (시스템 탄력성을 고려한 빗물저류조 운영수위 결정)

  • Lee, Eui Hoon;Lee, Yong Sik;Jung, Donghwi;Joo, Jin Gul;Kim, Joong Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.403-411
    • /
    • 2016
  • Recently, the number of occurrences of inundation and the severity of flood damage has increased rapidly as the frequency of localized heavy rainfall and the ratio of impervious area increased in urban areas. Most local governments focus on employing structural measures (e.g., the construction of detention reservoirs/pump stations, rehabilitation of drainage and sewer pipes) to prevent urban inundation. On the other hand, the effectiveness of implementing such structural measures is being dimished because there are already many inundation prevention facilities. The limitation of structural measures can be overcoming by employing non-structure measures, such as flood alerts and the operation of drainage facilities. This study suggests the pump operation rule (i.e., suggesting pump stop level) for a new detention reservoir operating method, which triggers the operation of a pump based on the water level at the monitoring node in urban drainage system. In the new reservoir operation, a total of 48 rainfall events are generated by the Huff distribution for determining the proper pump stop level. First, the generated rainfall events are distributed as frequencies, quartiles, and durations. The averaged system resilience value was determined to range from 1.2 m to 1.5 m is based on the rainfall-runoff simulation with rainfall generated by the Huff distribution. In this range, 1.2 m was identified considering the safety factor of 1.25 by the Standard on sewer facilities in 2011.