• Title/Summary/Keyword: Flip angle

검색결과 75건 처리시간 0.027초

Design and Safety Performance Evaluation of the Riding Three-Wheeled Two-Row Soybean Reaper

  • Jun, Hyeon-Jong;Choi, Il-Su;Kang, Tae-Gyoung;Kim, Young-Keun;Lee, Sang-Hee;Kim, Sung-Woo;Choi, Yong;Choi, Duck-Kyu;Lee, Choung-Keun
    • Journal of Biosystems Engineering
    • /
    • 제41권4호
    • /
    • pp.288-293
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the key factors in designing a three-wheeled two-row soybean reaper (riding type) that is suitable for soybean production, and ensure worker safety by proposing optimal work conditions for the prototype of the designed machine in relation to the slope of the road. Methods: A three-wheeled two-row soybean reaper (riding type) was designed and its prototype was fabricated based on the local soybean-production approach. This approach was considered to be closely related to the prototype-designing of the cutter and the wheel driving system of the reaper. Load distribution on the wheels of the prototype, its minimum turning radius, static lateral overturning angle, tilt angle during driving, and The working and rear overturning (back flip) angle were measured. Based on the gathered information, investigations were conducted regarding optimal work conditions for the prototype. The investigations took into account driving stability and worker safety. Results: The minimum ground clearance of the prototype was 0.5 m. The blade height of the prototype was adjusted such that the cutter was operated in line with the height of the ridges. The load distribution on the prototype's wheels was found to be 1 (front wheel: F): 1.35 (rear-left wheel: RL): 1.43 (rear-right wheel: RR). With the ratio of load distribution between the RL and RR wheels being 1: 1.05, the left-to-right lateral loads were found to be well-balanced. The minimum turning radius of the prototype was 2.0 m. Such a small turning radius was considered to be beneficial for cutting work on small-scale fields. The sliding of the prototype started at $25^{\circ}$, and its lateral overturning started at $39.3^{\circ}$. Further, the critical slope angle for the worker to drive the prototype in the direction of the contour line on an incline was found to be $12.8^{\circ}$, and the safe angle of slope for the cutting was measured to be less than $6^{\circ}$. The critical angle of slope that allowed for work was found to be $10^{\circ}$, at which point the prototype would overturn backward when given impact forces of 1,060 N on its front wheel. Conclusions: It was determined that farmers using the prototype would be able to work safely in most soybean production areas, provided that they complied with safe working conditions during driving and cutting.

UBM(Under Bump Metallurgy)이 단면 증착된 Si-wafer의 젖음성에 관한 연구 (A Study on the Wetting Properties of UBM-coated Si-wafer)

  • 홍순민;박재용;박창배;정재필;강춘식
    • 마이크로전자및패키징학회지
    • /
    • 제7권2호
    • /
    • pp.55-62
    • /
    • 2000
  • Si-wafer에 단면 코팅된 UBM(Under Bump Metallurgy)의 젖음성을 Sn-Pb 솔더에서 평가하기 위하여 wetting balance 법을 사용하였다. 단면 코팅된 UBM의 젖음곡선은 양면 코팅된 시편의 젖음 곡선과 비교할 때, 젖음곡선의 모양이 비슷하고 젖음곡선을 특징짓는 변수들의 온도에 대한 변화경향이 일치하였다. 단면 코팅된 금속층의 젖음성을 젖음곡선으로부터 정의한 새로운 젖음 지수 $F_{min}$, $F_{s}t_{s}$로 평가할 수 있었다. Au/Cu/Cr UBM은 젖음시간의 측면에서 Au/Ni/Ti UBM보다 젖음성이 우수하였다 Si-wafer에 단면 코팅된 UBM과 Sn-Pb 솔더의 접촉각을 $F_{s}$와 기울어짐각을 측정하고 메니스커스의 정적상태에서 힘의 평형으로부터 유도된 식을 이용하여 계산할 수 있었다.

  • PDF

UV 장비 및 대기압 플라즈마 장비를 이용한 PCB 표면 처리 효과 비교 (Comparison of PCB Surface Treatment Effect Using UV Equipment and Atmospheric Pressure Plasma Equipment)

  • 유선중
    • 마이크로전자및패키징학회지
    • /
    • 제16권3호
    • /
    • pp.53-59
    • /
    • 2009
  • PCB 표면 개질 및 세정에 있어서 저압 수은 램프를 이용한 UV 장비가 널리 사용되어왔다. 본 연구에서는 공정의 생산성을 향상 시키기 위하여 기존 UV 장비를 대체하여 리모트 DBD 방식의 대기압플라즈마 장비를 새로이 개발하였다. 두 장비의 생산성 비교는 처리 시간 증가에 따른 표면 접촉각의 변화를 측정함으로써 정량적으로 비교할 수 있었다. 측정 결과 대기압 플라즈마 장비의 생산성이 UV 장비에 비하여 매우 우수한 것으로 확인 되었다. 또한 XPS를 이용한 표면 조성 측정 결과 동일한 접촉각 수준에서 UV 및 대기압 처리의 효과는 유사한 것으로 파악되었다. 즉, 유기 오염 수준이 감소되었으며 표면 일부 표면 원소가 산회되었다. 최종적으로 대기압 플라즈마를 BGA제조의 플럭스 도포 공정에 적용하였는데, 대기압 플라즈마를 처리함으로써 도포 공정의 균일도가 향상되는 결과를 얻을 수 있었다.

  • PDF

굽힌 동전의 확률 (Bent coin toss probability)

  • 우덕관;오창혁
    • Journal of the Korean Data and Information Science Society
    • /
    • 제21권1호
    • /
    • pp.147-153
    • /
    • 2010
  • 동전을 이용하여 확률의 개념을 가르치는 일은 오랫동안 이루어져 왔으며, 통계 교과서에는 공정한 동전과 그렇지 않은 동전에 관한 많은 문제가 제시되고 있다. 그러나, 공정하지 않은 동전을 실제로 만나본 사람은 없는 것으로 알려져 있다. 본 연구에서는 확률 학습에 사용될 공정하지 않은 동전으로 가운데가 굽혀진 동전을 제시한다. 또한, 여러 가지 각도로 굽혀진 동전의 앞면이 나올 확률을 던지기 실험을 통하여 추정한다. 굽혀진 동전은 통계학 수업에서 공정하지 않은 동전을 다루는 경우에 실습용으로 사용될 수 있을 것이다.

fMRI를 이용하여 지적능력에 따른 뇌 신경망 규명 : 언어능력 vs 공간지각능력 (Brain neural networks based on individual's verbal and visuospatial abilities)

  • 이경화;박세훈;김연희;손진훈
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2001년도 춘계학술대회 논문집
    • /
    • pp.175-181
    • /
    • 2001
  • 본 연구의 목적은 사람들이 언어과제와 공간지각과제을 수행하는 동안 활성화되는 뇌 영역의 차이를 규명하는 것이다. 428명의 대학생을 대상으로 집단 심리실험을 수행하여, fMRI 연구를 위한 실험참여자로 17명의 오른손잡이 여대생을 선정하였다. 17명 중 8명은 언어능력은 뛰어나지만 공간지각능력이 떨어지고, 나머지 9명은 언어능력은 빈약하지만, 공간지각능력이 우수한 사람들이었다. fMRI 실험에 사용된 패러다임에는 언어과제와 공간지각과제가 각각 8block으로 구성되었으며, 각 block은 동일한 과제 3문항을 포함하였다. fMRI 이미징은 1.5T Siemens Vision Scanner로 수집되었으며, Single-shot EPI 기법으로 (TR/TE : 3840/40ms, flip angle : 90, FOV : 220, 64x64 matrix) 이미지를 스캔하였다. 자료분석은 SPM-99 소프트웨어를 사용하였다. 감산(subtraction)분석결과, 언어능력이 뛰어난 집단에서는 양측 대상회(bilateral cingulate gyri)와 좌측 상두정엽 (left superior parietal lobe)이 더 많이 활성화되었고, 언어능력이 떨어지는 집단에서는 양측 전두엽 (both frontal lobes)이 더 많이 활성화되었다. 공간지각능력이 떨어지는 집단에서는 우측 시상 (right thalamus)과 좌측 측-후두엽 (left temporooccipital)이 더 많이 활성화되었다. 언어능력이나 공간지각능력이 우수한 집단에서는 공통적으로 대상회 (cingulate gyri)가 활성화되었다.

  • PDF

Dual contrast MR imaging of liver with superparamagnetic iron oxides and mangafodipir trisodium: Influence of the first on the second contrast agents

  • Kim, Joo-Hee;Kim, Myeong-Jin;Chung, Jae-Joon;Lee, Jong-Tae;Yoo, Hyung-Sik
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.109-109
    • /
    • 2001
  • Purpose: To assess the feasibility of sequential administration of ferumoxides and mangafodi trisodium in the same imaging protocols. Method: Thirty patients underwent double-contrast enhanced MR imaging of liver usi ferumoxides (Fe-MRI) and mangafodipir trisodium (Mn-MRI) on 1.5T GE Horizon system. In twenty patients, Mn-MRI was immediately followed by Fe-MRI. In ten patients, Fe-MR was performed first, then Mn-MRI was performed immediately, In all cases, precontras T1-weighted in-phase and opposed-phase spoiled gradient echo (GRE) images an T2-weighted fast spin-echo images (TR 4000ms, TE 102ms, ETL 8-12) were obtained Fe-MRI was performed with FSE and steady state GRE (TE 10 msec, flip angle 30 sequences. Mn-MRI was performed with in-phase and opposed-phase spoiled GR sequences. The SNR changes after the use of each contrast agents were calculated.

  • PDF

Performance Evaluation of a Rapid Three Dimensional Diffusion MRI

  • Numano, Tomokazu;Homma, Kazuhiro;Nishimura, Katsuyuki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.356-358
    • /
    • 2002
  • MRI, particularly diffusion weighted imaging (DWI), plays vital roles in detection of the acute brain infarction$\^$1-4/ and others metabolic changes of biological tissues. In general, every molecule in biological tissues may diffuse and move randomly in three-dimensional space. However, in clinical diagnosis, only 2D-DWI is used. The authors have developed a new method for rapid three-dimensional DWI (3D-DWI). In this method, by refocusing of the magnetized spin with the applied gradient field, direction of which is opposite to phase encoding field. Magnetized spin of $^1$H is kept under the SSFP (steady state free precession)$\^$5-6/. Under SSFP, in addition of FID, spin echo and stimulated echo are also generated, so the acquired signal is increased. The signal intensity is increased depending on flip angle (FA) of magnetized spin. This phenomenon is confirmed by human brain and phantom studies. The performance of this method is quantitatively analyzed by using both of conventional spin echo DWI and 3D-DWI. From experimental results, three dimensional diffusion weighted images are obtained correctly for liquid phantoms (water, acetone and oil), diffusion coefficient is enhanced in each image. Therefore, this method will provide useful information for clinical diagnosis.

  • PDF

패키지 기판 습식 공정용 클램프 이송 장치의 개발 (Development of Clamp Type Transferring Mechanism for Package Substrate's Wet Process)

  • 유선중;허준연;조승현
    • 한국정밀공학회지
    • /
    • 제28권2호
    • /
    • pp.193-201
    • /
    • 2011
  • Clamp type transferring mechanism for package substrate's wet processes was newly developed instead of conventional roller type transferring mechanism. Clamp type transferring mechanism has the advantages of reducing the panel deflection and of minimizing the contact problem between the panel and the transferring mechanism. Individual clamp of the mechanism has two distinct mechanical functions which are perfectly fixing a panel during the transferring and generating adequate tension for the panel. To determine the mechanical parameters of the clamp, panel deflection simulation was conducted and the result was verified by the panel deflection measurement. Also, fixing angle of a clamp could be determined by the free body force analysis of individual clamp. Finally clamp type transferring mechanism was actually manufactured and the transferring performance was verified during the water spraying condition of the package substrate's wet processes.

Development of TEM Coil for Animal Experiments at 3T MRI System

  • Chu, Myung-Ja;Choe, Bo-Young;Kim, Kyung-Nam;Chung, Sung-Taek;Oh, Chang-Hyun;Lee, Hyoung-Koo;Suh, Tae-Suk
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.78-78
    • /
    • 2002
  • Purpose: The purpose of this study is to describe a distributed circuit approach to high frequency volume coil design illustrated with specific coils built accordingly and results obtained from animal studies at 3.0 tesla. Method: All experiments were conducted on 3T MRI system (Medinus Co., Ltd. Korea). The tuned TEM resonator measures 15cm outer diameter. by 10cm inside diameter by 30cm in length. The inside diameter and length were determined by animals body or head size (eg. rats or small dogs, etc.) while the outer diameter was chosen for compactness with some sacrifice of the optimal coil Q predicted for a larger cavity. A spin echo sequence with a TR/TE/flip angle=500/12.4ms/$75^{\circ}$was used to check image qualities with phantom. The breed of rat which used for animal images was Sprague-dawley(SD) and was anesthetic using ketamin hydrochloride 75mg/kg.

  • PDF

Efficient baseline suppression via TIP and modified DEPTH

  • Hyun, Namgoong
    • 한국자기공명학회논문지
    • /
    • 제26권4호
    • /
    • pp.51-58
    • /
    • 2022
  • The baseline flattened NMR spectrum has been achieved by several methodologies including pulse manipulation with a series of phase cycling. The background signal inherent in the probe is also main source of baseline distortion both in solution and solid NMR. The simple direct polarization with 90° pulse flipping the magnetization from the z-axis onto the receiver coil requires the strong rf pulse enough to encompass the wide frequency range to excite the resonance of interest nuclei. Albeit the perfect polarization 90° pulse, the signal from the unwanted magnetic fields such as background signal can not be completely suppressed by suitable phase cycling. Moreover, slowly baseline wiggling signal from the low 𝛾 nuclei is not easy to eliminate with multiple pulse manipulation. So there is still need to contrive the new scheme for that purpose in an adroit manner. In this article new triple pulse excitation schemes for TIP and modified DEPTH pulse sequence are analytically examined in terms of arbitrary phase and flip angle of pulse. The suitable phase cycling for these pulse trains is necessary for the good sensitivity and resolution of the spectrum. It is observed that the 13C sensitivity TIP experiment is almost equal to the CP/MAS with modified DEPTH sequence, both of which are applicable to both solid and solution state NMR.