• Title/Summary/Keyword: Flicker Test

Search Result 41, Processing Time 0.025 seconds

A Design and Implementation of a Mobile Test Device Based-on Embedded System (임베디드 기반의 모바일 LCD 모듈 검사장비 설계 및 구현)

  • Kim, Hong-Kyu;Lee, Ki-Wha;Moon, Seung-Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.6
    • /
    • pp.523-529
    • /
    • 2008
  • In this paper, we proposed mobile LCD module test device on embedded based, when operating the existing LCD, divide flicker clearly in full frame, and configuration so as to support between other CPU interface, MDDI, SPI, 24Bit RGB interface, etc. that is based on a high-speed CPU. In addition, when demand to test about each pixel of LCD, it is possible to change IP design of H/W, FPGA, but proposed system is application possible without other design changing. Proposed system is made smaller and equipped with battery, so secure with mobility for effective test the LCD/OLED module and it is able to test the pattern by the client program, for example exiting picture, mpeg, simple pattern test and test per pixel, scale, rotation, Odd/Even pixel per video, etc. From now on, if integrating with independent test system and it is configured that is able to mutual communication and test, it is expected to reduce consumption of human resources and improve productivity for LCD module test.

Development of Image Quality Register Optimization System for Mobile TFT-LCD Driver IC (모바일 TFT-LCD 구동 집적회로를 위한 화질 레지스터 최적화시스템 개발)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.592-595
    • /
    • 2008
  • This paper presents development of automatic image quality register optimization system using mobile TFT-LCD (Thin Film Transistor-Liquid Crystal Display) driver IC and embedded software. It optimizes automatically gamma adjustment and voltage setting registers in mobile TFT-LCD driver IC to improve gamma correction error, adjusting time, flicker noise and contrast ratio. Developed algorithms and embedded software are generally applicable for most of the TFT-LCD modules. The proposed optimization system contains module-under-test (MUT, TFT-LCD module), control program, multimedia display tester for measuring luminance, flicker noise and contrast ratio, and control board for interface between PC and TFT-LCD module. The control board is designed with DSP and FPGA, and it supports various interfaces such as RGB and CPU.

  • PDF

A Study on Malfunction Mode of CMOS IC Under Narrow-Band High-Power Electromagnetic Wave (협대역 고출력 전자기파로 인한 CMOS IC에서의 오동작 특성 연구)

  • Park, Jin-Wook;Huh, Chang-Su;Seo, Chang-Su;Lee, Sung-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.9
    • /
    • pp.559-564
    • /
    • 2016
  • This study examined the malfunction mode of the HCMOS IC under narrow-band high-power electromagnetic wave. Magnetron is used to a narrow-band electromagnetic source. MFR (malfunction failure rate) was measured to investigate the HCMOS IC. In addition, we measured the resistance between specific pins of ICs, which are exposed and not exposed to the electromagnetic wave, respectively. As a test result of measurement, malfunction mode is shown in three steps. Flicker mode causing a flicker in LED connected to output pin of IC is dominant in more than 7.96 kV/m electric field. Self-reset mode causing a voltage drop to the input and output of IC during electromagnetic wave radiation is dominant in more than 9.1 kV/m electric field. Power-reset mode making a IC remained malfunction after electromagnetic radiation is dominant in more than 20.89 kV/m. As a measurement result of pin-to-pin resistance of IC, the differences between IC exposed to electromagnetic wave and normal IC were minor. However, the five in two hundred IC show a relatively low resistance. This is considered to be the result of the breakdown of pn junction when latch-up in CMOS occurred. Based on the results, the susceptibility of HCMOS IC can be applied to a basic database to IC protection and impact analysis of narrow-band high-power electromagnetic waves.

A Study on the Application of the DVR System using EMTDC Simulation (EMTDC 시뮬레이션을 이용한 DVR 시스템 적용에 관한 연구)

  • Choy, Y.D.;Kwak, N.H.;Jeon, Y.S.;Jeon, D.H.
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.69-71
    • /
    • 2008
  • Recently, the interest on power quality has been hot issue because the equipments cause voltage disturbance and become more sensitive to the voltage disturbance. The DVR(Dynamic Voltage Restorer) is one of the Custom Power Device that can compensate the voltage. DVR operates as a series connected compensator whose output voltage can be controlled system voltage. And the magnitude of compensation voltage is limited by the characteristics of system and load. Compensation capability of DVR was simulated by EMTDC under several condition. This paper analyzed effect of DVR's compensation at power quality test center which has SSFG(Sag, swell, and Flicker Generator, CPDs(SSTS, DVR, DSTATCOM), and loads.

  • PDF

A Study on the Characteristics of Control Schemes for STATCON (STATCON 제어방식에 따른 특성 연구)

  • Han, Y.S.;Cha, J.D.;Hong, S.W.;Lee, H.S.;Moon, K.W.;Yoon, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2076-2078
    • /
    • 1998
  • This paper presents STATCON(Static Condenser) control schemes for voltage regulation, power factor correction and harmonics mitigation. Each control scheme can be applied in the system depending on the system requirements. The 20KVA STATCON is developed and tested in the reduced system model for the verification of three different control algorithms. The results of proposed controls are compared for power factor correction and voltage regulation algorithms. For each algorithm, harmonic mitigation scheme is adopted as a part of control. Finally verification of STATCON for the transient response is implemented by voltage flicker test.

  • PDF

The Study on Affecting Subject Accomplishment by Noise (소음이 과제수행에 미치는 영향에 관한 연구)

  • Kim, Sung-Cheol;Park, Keun-Sang;Kim, Kwan-Woo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.121-128
    • /
    • 2010
  • The purpose of this study is to confirm the impact of noise on subject accomplishment as well as physical/mental load, and evaluates the effects of noise-masking and earplug. 15 college students participate in the test, and the comparison is performed by executing four projects according to conditional categories of noise environments; control condition, noise condition, earplug condition, and noise-masking condition. Noise in the field site of the H manufacturer was used as the noise source, the general job aptitude test which consist of linguistic ability, math ability, perception ability, reasoning ability was used as the task of this project. To estimate physical/mental load evaluation, we used the heart rate R-R interval, Criteria flicker fusion frequency(CFF) and measured NASA-TLX workload for subjective evaluation. As the research outcome, it is shown that there is a meaningful difference for the project task score, dropping rate of CFF, the heart rate, and NASA-TLX subjective evaluation score according to conditions of noise environment. Therefore, the impact of noise on capability of subject accomplishment as well as physical/mental load was confirmed along with the effects of using earplug and noise-masking.

Comparison of Some Physiological Indices during Graded Load with Paced & Self-Paced Respiration (보조와 외부보조 호흡시 부하에 대한 생리적 지표들의 비교연구)

  • Kim, Jeong-Seok;Lee, Jong-Seong;No, Jae-Ho
    • Journal of the Ergonomics Society of Korea
    • /
    • v.4 no.2
    • /
    • pp.17-24
    • /
    • 1985
  • To compare heart rate, $O_2$ uptake, $Vo_2$ ($O_2$ consumption), blood pressure (systolic, diastolic), reaction time, stability, flicker fusion value during 4 load levels with Rs (self-paced respiration) and Rp (paced respiration), 4 subjects participated in this experiment 1 hour/day, 6 days/week for 9 weeks. The cycle of Rp is 6 sec. (inspiration: 3 sec. & expiration: 3 sec.) Implications of the results are discussed in terms of the change in the physiological responses and human performance by the respiratory pattern. The results are as follows, 1. The changing magnitude of heart rate with Rp was larger than with Rs and the variance during load level 4 was significant. 2. The $Vo_2$ with Rp was smaller than with Rs and maximal $O_2$ uptake given load levels with Rp occurred and for two subjects, it significantly moved from low load level to high load level. 3. The changing magnitude of blood pressure was not consistent but the systolic pressure with Rp was smaller at rest than with Rs. 4. The score of reaction time test and stability test with Rp was better than with Rs.

  • PDF

A Study on Driving Characteristics of the Elderly Driver using a Driving Simulator (운전모의장치를 이용한 고령자의 운전특성 연구)

  • Lee, Won-Young
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.103-111
    • /
    • 2006
  • The purpose of this study was to analyse the relationships between cognitive abilities and driving characteristics of elderly drivers. Driving characteristics of elderly and younger drivers who were driving a fixed base driving simulator vehicle were examined. Participants consisted of 12 drivers over age 65 (the 'older' group) and 12 drivers between the ages of 25 and 55 (the "younger" group). As indices of cognitive ability, critical flicker fusion frequency (CFF) tests and cognitive reaction tests were given before the driving task. CFF was also tested after the simulated driving task for both groups. Cognitive reaction tests, which were composed of speed estimation tests, multiple choice reaction tests and obstacle avoidance tests, were developed by the Korean Road Traffic Safety Authority in 2003. CFF values between the two groups exhibited significant differences both before and after the task, with a p-value less than 0.01 and a t-value of -3.01 before the test and a p-value less than 0.031 and a t-value of -2.35 after the test. Older drivers' CFF values were lower than those of the younger. However, there was no difference in older or younger driver CFF values before and after the task within the same group. Except for the multiple choice reaction test, there was no difference in cognitive reaction test results between the two groups. The elderly drivers made more errors though they did not differ from the younger drivers in reaction times. At the simulated driving task the reaction time of the elderly driver was longer than that of the younger; however, the driving speed of the elderly was lower and the number of collisions greater. There was a positive correlation (r=.496) between the number of errors in the multiple choice reaction test and the number of collisions in the driving task. Therefore, it was identified that critical attributes contributing to automobile crashes involving elderly drivers included cognitive difficulty in judging and responding to complex situations.

Single-Stage Quasi Resonant Type PSR(Primary Side Regulation) PWM Converter for the LED Drive in TRIAC Phase Controlled Dimmer (TRIAC위상 제어 조광기에서의 LED구동을 위한 Single-Stage 준 공진형 PSR(Primary Side Regulation) PWM 컨버터)

  • Han, Jae-Hyun;Lim, Young-Cheol;Jung, Young-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.84-94
    • /
    • 2013
  • In case when the existing TRIAC phase controlled dimmer is drove for the LED lighting equipments, there are many problems such as the LED flicker in low phase-angles, the acoustic noise and elements damage by increase of the peak voltage in the input filter capacitor, mulfunction by insufficiency of the TRIAC holding current, and the abnormal oscillation by LC resonant. In this paper, we proposes the single-stage quasi-resonant PSR(Primary Side Regulation) PWM converter, and the design, the simulation and experiment are performed. As a result, it could confirm that the proposed PWM converter is the lighting equipments for LED drive which can alternate the existing 60W class incandescent bulbs and it has the high drive performance of the efficiency 80% and over, the power factor 0.95 and over under the normal voltage 220V. Finally, total harmonic distortion(THD) is gratified with a standard[1] of the lighting equipments and the durability is evaluated as the high reliablilty of 150,000 hours and over.

A Study on the Development of an Electronic Ballast for 70W Ceramic Discharge Metal Halide Lamps (70W 세라믹 방전관 메탈할라이드 램프용 전자식 안정기 개발에 관한 연구)

  • 김일권;길경석;이성근;김진모
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.301-304
    • /
    • 2002
  • This paper describes a design and fabrication of an electronic ballast for 70[W]ceramic discharge metal halide lamps. The proposed ballast is composed of a rectifier, an active PFC, a half-bridge inverter, a LC resonant circuit and a controller. The design also includes a specially designed time circuit which provides reignition of the lamp. Running frequency of the ballast is set at 45[KHz]to avoid acoustic-resonance and flicker. from the test results, input power factor and efficiency of the ballast were estimated 91[%] and 97.7[%], respectively.

  • PDF