• Title/Summary/Keyword: Flexible tissue surface

Search Result 10, Processing Time 0.029 seconds

Management of flabby ridges using liquid supported denture: a case report

  • Keni, Nandita Nitin;Aras, Meena Ajay;Chitre, Vidya
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.1
    • /
    • pp.43-46
    • /
    • 2011
  • Flabby ridges commonly occur in edentulous patients. Inadequate retention and stability of a complete denture are the often encountered problems in these patients. A liquid supported denture due to its flexible tissue surface allows better distribution of stress and hence provides an alternate treatment modality in such cases. This case report presents the use of a liquid supported denture in a patient with completely edentulous maxillary arch with flabby tissue in anterior region opposing a partially edentulous mandibular arch.

Palate bone exposure from flexible denture: a case report (탄성의치에 의한 구개부 골노출 증례)

  • Jin, Soo-Yoon;Kim, Mi-Gyeong;Kim, Hee-Jung;Lee, Gyeong-Je
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.1
    • /
    • pp.19-24
    • /
    • 2017
  • Recently, flexible denture is widely used with some advantages such as esthetics, flexibility and biocompatibility. However, there is an opposite opinion about stability because of the movement of denture by the material's flexibility. As the denture moves to tissue surface during mastication, it irritates the supporting tissue. It can lead to trauma and rapid resorption of residual ridges if this irritation lasts for a long time. In this case, the patient has used flexible denture with insufficient stability, retention and support for several years and thus continuous irritation of the supporting tissue resulted in palate bone exposure. The patient discomfort and palate bone exposure underwent improvements by the new denture with stability and retention. A careful case selection for flexible denture, regular checkup and proper treatment are necessary to prevent the side effects.

A Study on The Ultra-precision Polishing Method of Co-Cr-Mo alloy Using MR Fluid Polishing (MR Fluid Polishing을 이용한 Co-Cr-Mo alloy의 초정밀 연마 방법)

  • Shin, Bong-Cheol;Kim, Byung-Chan;Song, Ki-Hyeok;Cho, Myeong-Woo
    • Design & Manufacturing
    • /
    • v.11 no.3
    • /
    • pp.8-12
    • /
    • 2017
  • In general, metallic bio-materials is more widely used in solid tissue like bone or tooth than flexible tissue such as skin or muscle. Especially, Cobalt Chrome Molybdenum(Co-Cr-Mo), which is used in tooth surgery, has a great corrosion resistance. Because this bio-material is non-toxic in human body, and has a bio-compatibility that the vital reaction is not occurred with tissue in body. However the chemical reaction is occurred by fatal matter that deteriorate the property of material surface in conventional polishing, and it can affect to fatal disease in human body or decrease the material properties such as hardness, yield strength or bio-compatibility. This surface in poor condition can cause development of corrosion or bacteria. In this study, MR fluid polishing is used to minimize the scratch, pit or surface flaws generated in conventional polishing. Surface roughness is measured according to the polishing condition to obtain fine surface condition.

Endovaginal and Endorectal Surface Coils for in-ViVo Human MR Imaging and Spectroscopy (자궁경부암 진단용 MR 질내표면코일과 전립선암 진단용 MR 경직장표면코일의 제작 : 인체에서의 MR 영상과 MR 분광)

  • 문치웅;조경식
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.481-491
    • /
    • 1995
  • Endovaginal and endorectal receiver only surface coils were designed for MR imaging (MRI) and $^1H$ MR spectroscopy (MRS) for the uterine cervix and the prostate. The shape of endovaginal coil wire was rectangular with round corner. Size of the coil wire was empirically determined for 7cm and 4cm along the long and short axis, respectively. The coil wire loop was supported by acryl handle and bent about $150^{\circ}$ at one side of the loop considering the average angle of the cervix to the vagina. We called this as a "spoon-type endovaginal coil". The wire of the endorectal coil was made of the flexible materials so that the wire loop became long elliptic shape by pushing the acryl handle into the plastic tube for the comfort of patients when the coil was inserted into the cervix. Then, the shape was maintained to be circle by popping out handle. Conventional spin echo (SE) and fast spin echo (FSE) sequences were used as 71 and 72 weighted imaging sequences, respectively. Matrix size was 128~$256{\times}256$. FOVs for surface coil and body coil were 14cm and 24cm, respectively. 3D volume localized in vivo $^1H$ MR spectroscopy of the human cervix and prostate was performed using PRESS or STEAM localization method with the following parameters . TR=3 sec, TE=135 msec for PRESS or 30 msec for STEAM, NEX=2, NS=48, Sl=2048, and SW=2500 Hz. Using home-built endovaginal and endorectal coils, excellent T1- and T2-images were obtained to visualize early cervical and prostate tumors. 3D volume localized in vivo IH MRS was useful to differentiate the cancerous tissue from the normal tissue.

  • PDF

Bio-degradable 3D-scaffold fabrication using rapid-prototyping system (쾌속조형시스템을 이용한 생체 조직 재생용 지지체 제작과 특성분석)

  • Kim, Ji-Woong;Park, Ko-Eun;Lee, Jun-Hee;Park, Su-A;Kim, Wan-Doo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1697-1699
    • /
    • 2008
  • The purpose of tissue engineering is to repair or replace damaged tissues or organs by a combination of cells, scaffold, suitable biochemical and physio-chemical factors. Among the three components, the biodegradable scaffold plays an important role in cell attachment and migration. In this study, we designed 3D porous scaffold by Rapid Prototyping (RP) system and fabricated layer-by-layer 3D structure using Polycarprolactone (PCL) - one of the most flexible biodegradable polymer. Furthermore, the physical and mechanical properties of the scaffolds were evaluated by changing the pore size and the strand diameter of the scaffold. We changed nozzle diameter (strand diameter) and strand to strand distance (pore size) to find the effect on the mechanical property of the scaffold. And the surface morphology, inner structure and storage modulus of PCL scaffold were analyzed with SEM, Micro-CT and DMA.

  • PDF

Characteristics of the Histological Structure of the Mandibular Barbels of Two Species of Catfish (Siluridae) from Korea (한국의 메기과 (Siluridae) 어류 2종의 상악 수염의 조직학적 특성)

  • Park, In-Seok;Kim, Chi-Hong
    • Korean Journal of Ichthyology
    • /
    • v.17 no.1
    • /
    • pp.36-42
    • /
    • 2005
  • Histological observations on the barbels of catfish (Siluridae) in Korea are reported. The mandibular barbel of Far Eastern catfish, Silurus asotus, has epidermis and dermis surrounding an axial rod of cartilage. The stratified epidermis embodies mucous cells, club cells, and taste buds. The mucous cells, which are thin rims of basophilic cytoplasm, and the taste buds, which are basophilic, are located at the surface and the distal portion of the epidermis, respectively. The basement membrane lies between the epidermis and dermis except in places of dermal papillae. The dermis is made up of loose connective tissue fibers enclosing nerve bundles and blood vessels. The central region of cartilage is innermost and enclosed within muscle layers. The mandibular barbel of slender catfish, S. microdorsalis, has an identical structure to those of the Far Eastern catfish however, the percentage thickness of epidermis in the upper and lower parts of the barbel and the number of taste buds in the upper and middle parts of the barbel are different from those of Far Eastern catfish. This study shows that the mandibular barbels in Far Eastern catfish and slender catfish are of a stiff and flexible type.

Electron microscopic studies on Flavobacterium branchiophila in experimentally induced gill disease of rainbow trout (세균성(細菌性) 아가미병(病)에 실험적(實驗的)으로 감염(感染)된 무지개송어에 있어서 Flavobacterium branchiophila에 대한 전자현미경학적(電子顯微鏡學的) 연구(硏究))

  • Heo, Gang-joon
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.3
    • /
    • pp.381-387
    • /
    • 1992
  • Gill epithelia of normal rainbow trout fingerlings and abnormal ones suffering bacterial gill disease by experimental infection were examined by transmitting electron microscopy (TEM) and scanning electron microscopy (SEM). TEM observations revealed that Flavobacterium branchiophila consisted of slender rods measuring 0.5 by 5 to $8{\mu}m$, and they had which were long, thin, flexible filaments measuring approximately 4 nm by $1{\mu}m$, and packed together to organize into bundles. Morphological alterations of the diseased epithelia started at hypertrophy of the lamellar epithelium. F branchiophila attached to the gill surface of infected fish through pili with a regular distance, and did not invade into gill tissue. In SEM observations, normal surface ultrastructure of epithelial cell in the outermost layer were characterized by a typical labyrinth-like structure branching and anastomosing microridges on the cell surface. Hyperplastic lesions in experimentally infected gill were most serious at near the tips. Each filament exhibited a club-like, and fusion between the filaments was sometimes observed at their tips. On the surface of gill filaments, thread-like bacterial cells attached and were entangled. The bacterial cells almost covered the surface. After immersion in 5 % NaCl, the cell of F branchiophila, however, appeared to be indeterminate shape.

  • PDF

Piezoelectric Polymer Ultrasound Transducers and Its Biomedical Applications (압전고분자 초음파 트랜스듀서와 생의학적 응용)

  • Ha, Kang-Lyeol;Cao, Yonggang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.585-596
    • /
    • 2012
  • PVDF(poly vinylidene fluoride) and P(VDF-TrFE)(poly vinylidene fluoride-tetrafluoroethylene) are the typical piezoelectric polymers with unique properties. Even they are inferior to conventional piezoelectric ceramics PZT in electromechanical conversion efficiency and interior loss, though they are superior in receiving sensitivity and frequency bandwidth. Their acoustic impedances are relatively close to water or biological tissue and it is easier to make thin film than other piezoelectric materials. Futhermore, the film is so flexible that it is easy to attach on a complex surface. Those properties are suitable for the ultrasound transducers which are useful for medical and biological application, so that various types of polymer transducers have been developed. In this paper, several important considerations for design and fabrication of piezoelectric polymer transducers were described and their effect on the transducer performance were demonstrated through the KLM model analysis. Then, it was briefly reviewed about the structures of the polymer transducers developed for obtaining images as well as the characteristics of the images in several important medical and biological application fields.

Biomimetic Analysis on the Spider Silk Apparatus for Designing the Nanofiber-spinning Nozzle (나노섬유 방사노즐 설계를 위한 거미 실크 방적장치의 생체모사 분석)

  • Moon, Myung-Jin;Kim, Hoon;Park, Jong-Gu
    • Applied Microscopy
    • /
    • v.42 no.2
    • /
    • pp.67-76
    • /
    • 2012
  • The biomimetic approach on the cuticular spinning nozzles of the major ampullate silk glands in the golden-web spider Nephila calvata has been attempted using various visualizing techniques of light and electron microscopes to improve the design of spinning nozzle for producing synthetic nanofibers spun from electrospinning apparatus. The major ampullate spigot which has the most effective nozzle system to produce nanofibers for dragline silk with high strength and elasticity is connected via the bullet type spigot on anterior spinneret with flexible terminal segment. The excretory duct which transports the liquid silk feedstock from ampulla to spigot is divided into 3 limbs by loops back on itself to form an S-shape morphology that is bundled in connective tissue. Final diameter of the nanofibers at nozzle was dramatically reduced by gradual narrowing of duct cuticle less than 10 times comparing to its original size of funnel region. Moreover, the funnel has a characteristic cuticular organization with porous microstructure which seems to be related to water removal from feedstock of silk precursors. High magnification electron micrographs also reveal the presence of the spiral grooves on the surface of the cuticular intima near the valve which presumed to reduce friction during rapid flow of liquid silk.

A Study on the Tree Surgery Problem and Protection Measures in Monumental Old Trees (천연기념물 노거수 외과수술 문제점 및 보존 관리방안에 관한 연구)

  • Jung, Jong Soo
    • Korean Journal of Heritage: History & Science
    • /
    • v.42 no.1
    • /
    • pp.122-142
    • /
    • 2009
  • This study explored all domestic and international theories for maintenance and health enhancement of an old and big tree, and carried out the anatomical survey of the operation part of the tree toward he current status of domestic surgery and the perception survey of an expert group, and drew out following conclusion through the process of suggesting its reform plan. First, as a result of analyzing the correlation of the 67 subject trees with their ages, growth status. surroundings, it revealed that they were closely related to positional characteristic, damage size, whereas were little related to materials by fillers. Second, the size of the affected part was the most frequent at the bough sheared part under $0.09m^2$, and the hollow size by position(part) was the biggest at 'root + stem' starting from the behind of the main root and stem As a result of analyzing the correlation, the same result was elicited at the group with low correlation. Third, the problem was serious in charging the fillers (especially urethane) in the big hollow or exposed root produced at the behind of the root and stem part, or surface-processing it. The benefit by charging the hollow part was analyzed as not so much. Fourth, the surface-processing of fillers currently used (artificial bark) is mainly 'epoxy+woven fabric+cork', but it is not flexible, so it has brought forth problems of frequent cracks and cracked surface at the joint part with the treetextured part. Fifth, the correlation with the external status of the operated part was very high with the closeness, surface condition, formation of adhesive tissue and internal survey result. Sixth, the most influential thing on flushing by the wrong management of an old and big tree was banking, and a wrong pruning was the source of the ground part damage. In pruning a small bough can easily recover itself from its damage as its formation of adhesive tissue when it is cut by a standard method. Seventh, the parameters affecting the times of related business handling of an old and big tree are 'the need of the conscious reform of the manager and related business'. Eighth, a reform plan in an institutional aspect can include the arrangement of the law and organization of the old and big tree management and preservation at an institutional aspect. This study for preparing a reform plan through the status survey of the designated old and big tree, has a limit inducing a reform plan based on the status survey through individual research, and a weak point suggesting grounds by any statistical data. This can be complemented by subsequent studies.