• Title/Summary/Keyword: Flexible PV

Search Result 18, Processing Time 0.026 seconds

A study on the MPPT tracking algorithm using angle control of flexible PV in BIPV (BIPV에서 Flexible PV의 각도 조절을 이용한 MPPT 추적 알고리즘 연구)

  • Kim, Jaejin
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.3
    • /
    • pp.27-33
    • /
    • 2017
  • In this paper presents the MPPT tracking algorithm using angle control of flexible PV in BIPV. The proposed algorithm is based on MPPT tracking algorithm for curtain wall using flexible PV. It is an algorithm to find optimal power generation condition by controlling the angle of flexible PV using the air layer of window. The angle of flexible PV tests the power generation by separating the center of flexible PV into the interior angle in the interior direction and the external angle in the center of flexible PV. When the angle of flexible PV was used as interior angle, the generation amount was increased by 15.79% and increased by 8.45% compared with the external angle. MPPT tracking is performed on the generation amount of the interior angle which has the most power after comparing the generation amount according to the bending shape of the flexible PV. This algorithm can be the most efficient method for the curtain wall using flexible PV because the bending pattern with the greatest amount of power generation may be different because the environment of the building applying the curtain wall is different.

Comparison of Performance of Flexible Solar Cells construction applied to Curtain Walls (커튼 월에 적용하는 플랙시블 태양전지의 모양에 따른 성능 비교)

  • Kim, Jaejin
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.4
    • /
    • pp.163-168
    • /
    • 2018
  • In this paper presents comparison of performance of flexible solar cells construction applied to curtain walls. The proposed paper compares power generation for curtain walls of various shapes using flexible PV. Through the comparison of performance, the power generation was compared by installing various types of flexible PV on the air layer of double windows. By comparing the measured power generation, it is possible to find an optimal flexible PV shape that can be applied to a curtain wall. Flexible PV installation was divided into diagonal, S and W shapes. As a result of comparison, the amount of power generation when there was no flexure of flexible PV was large. Also, as the angle with the light source increased, the power generation decreased. Therefore, it is necessary to study the structure which can fix the PV more than the flexible PV and to be able to direct the sun without distortion.

Fabrication of Lightweight Flexible c-Si Shingled Photovoltaic Modules for Building-Applied Photovoltaics (건물 부착형 고경량 유연성 슁글드 태양광 모듈)

  • Minseob, Kim;Min-Joon, Park;Jinho, Shin;Eunbi, Lee;Chaehwan, Jeong
    • Current Photovoltaic Research
    • /
    • v.10 no.4
    • /
    • pp.107-110
    • /
    • 2022
  • Lightweight and flexible photovoltaic (PV) modules are attractive for building-integrated photovoltaic (BIPV) applications because of their easy construction and applicability. In this study, we fabricated lightweight and flexible c-Si PV modules using ethylene tetrafluoroethylene (ETFE) front cover and shingled design string cells. The ETFE front cover instead of glass made the PV modules lighter in weight, and the shingled design string cells increased the flexibility. Finally, we fabricated a PV module with a conversion power of 240.08 W at an area of 1.25 m2 and weighed only 2 kg/m2. Moreover, to check the PV module's flexibility, we conducted a bending test. The difference of conversion power between the modules before and after bending shown was only 1.7 W, which showed a power reduction rate of about 0.7%.

A Study on the Comparison of the PV Module Generation from Daylight Irradiation and Indoor Lighting Savings with Lighting Simulation (일사량 분석을 통한 PV모듈 발전량과 시뮬레이션을 이용한 실내 조명에너지 절감량 비교)

  • Park, Yoon-Min;Hong, Seong-Kwan;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.17-24
    • /
    • 2010
  • Recently, BIPV system which is good enough for maintenance and functions with the shading system is being used. However BIPV system with the shading system is different from existing PV module because of using flexible PV module. Prior to the application of the BIPV system, the clearness index was calculated by Erbs et al.(1982) and analyzed for the amount of electric power generation of sky irradiance with measured data. To predict electric lighting energy savings in daylit space, electric lighting power savings with amount of PV module electric power generation was compared by using Relux 2010 software in this study.

A Photovoltaic Device Model for Grid-connected PV System Simulation (계통연계형 태양광발전시스템의 태양광전지모델 시뮬레이션)

  • Campbell, Ryan;Kim, Hak-Man;Lee, Jong-Su;Shin, Myong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.18-19
    • /
    • 2006
  • The recent interest in distributed generation (DG) due to the opening of the electricity market and the need for alternatives to conventional fossil fuel-based electricity generation has created renewed interest in grid-connected photovoltaic(PV) systems. Many studies are being performed at the power system level to examine the impacts of grid-connected PV systems and several models for PV arrays have been proposed in the literature. However, the complexity of these models and difficulties of implementing them in various software programs can be deterrents to their use. This paper proposes a robust and flexible PV device model suitable for dynamic and transient studies where the PV array's non-linear DC characteristics are important. The model's implementation in software is straightforward and it can even be constructed using standard software library components, as demonstrated using PSCAD/EMTDC.

  • PDF

Evaluation of Residential Performance in Commercialization of Flexible Unit Infra Free Residential for Disaster (재난 시 대응을 위한 Flexible-Unit형 인프라 프리(임시)주거의 성능평가)

  • Park, Beungyong;Cho, Jinkyun;Jeong, Yongdae;Lee, Wonhak
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.6
    • /
    • pp.37-49
    • /
    • 2018
  • In this paper a new kind of unit-prefabricated building is shown. The unit-prefabricated buildings are made up living unit, energy unit, water unit. The design trend implemented the energy insulation, solar PV panels, energy storage system which are maintained for zero energy buildings. We made a prototype for zero energy flexible residential unit. The first step, we was evaluated the physical performance, insulation, airtightness. The second step, we was evaluated energy performance building to design heating and cooling system to combined PV system. As a results, the insulation performance wall was $0.18W/(m^2{\cdot}K)$. The results of air-tightness was 12.13 ACH@50 (1/h). The building energy demand ratings and solar energy generation has the possible to be ballanced.

Flammability and Released Toxic Halogen Gases during Combustion of Flame-Retardant Flexible Polyurethane Foam (난연 연질 폴리우레탄 반도체의 난연성과 연소시 발생되는 유독성 할로겐 기체 검출에 관한 연구)

  • 전종한
    • Journal of the Korean Society of Safety
    • /
    • v.6 no.1
    • /
    • pp.26-30
    • /
    • 1991
  • Flammability, and released toxic halogen gases during combustion about two kinds of flame-retardant flexible foam(F.R. flexible PV foam) were investigated. One of the above was F.R. flexible PU foam with the containment of halogen and the other was manufactured with pure flexible PU foam in aqueous solution of alumina trihydrate(ATH) and dried 4 hours at 10$0^{\circ}C$. Flammability by L.O.I and UL94 HF-1 of the two materials were similarly shown. And combustion gases were analyzed with GC-Mass. HCI, CI$_2$ and HF were detected at both halogen being contained F.R. flexible PU foam and ATH dolng one The reason, to find halogen gases from burning ATH-containing F, R. flexible PU foam which wasn't used for any halogenated F.R., could be considered as by using trichlorofluoromethane with blowing agent to make PU foam. The relative quanity of relesed halogen gases of F.R. flexible PU foam with the containment of halogen had been indicated tree times HCI and CI$_2$, two times HF than ATH containing, respectively.

  • PDF

Policy implications for up-scaling of off-grid solar PV for increasing access to electricity in rural areas of Nepal: Best practices and lessons learned

  • Sapkota, Surya Kumar
    • Bulletin of the Korea Photovoltaic Society
    • /
    • v.6 no.1
    • /
    • pp.8-20
    • /
    • 2020
  • Nepal has huge potential of hydro and other renewable energy resources including solar energy. However, only 70% of the total population have access to electricity despite the long history of hydropower development in the country. Still more than 37% population in rural areas and around 73% population in Karnali Province, one of the least developed provinces, are living without access to electricity despite taking several initiatives and implementing various policies by government supporting electrification in off-grid rural areas. Government together with donors and private sector has extensively been promoting the off-grid solar photovoltaic (PV) echnology in un-electrified areas to increase electricity access. So far, more than 900,000 households in rural areas of Nepal are getting electricity from stand-alone solar PV systems. However, there are many challenges including financial, technical, institutional, and governance barriers in Nepal. This study based on extensive review of literatures and author's own long working experiences in renewable energy sector in Nepal, shares the best practices and lessons of off-grid solar PV for increasing access to electricity in rural areas of Nepal. This study suggests that flexible financial instruments, financial innovations, bundling of PV systems for concentrating energy loads, adopting standards process, local capacity building, and combination of technology, financing and institutional aspects are a key for enhancing effectiveness of solar PV technology in rural areas of Nepal.

유기태양전지 연구 동향

  • Kim, Gyeong-Gon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.20-20
    • /
    • 2010
  • Organic based photovoltaics (OPV) have been received a lot of attention because they are lightweight, inexpensive to fabricate and flexible compare to crystalline Si solar cells. In this seminar, several important progresses in the Polymer PV, such as, formation of bulk heterojunction, development of post annealing technique, tandem cell fabrication will be introduced. In addition that, some efforts to achieve the further improvement in the performance of the Polymer PV will be discussed.

  • PDF

A Study on the Large-scale Adoption Method of Distribution System Interconnected with PV System by Energy Storage System (전기저장장치를 이용한 태양광전원이 연계된 배전계통 수용성향상 방안에 관한 연구)

  • Nam, Yang-Hyun;Choi, Sung-Sik;Kang, Min-Kwan;Lee, Hu-Dong;Park, Ji-Hyun;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1031-1039
    • /
    • 2018
  • If large-scale PV systems are continuously interconnected to distribution system, customer voltages could violate the allowable voltage limit($220{\pm}13V$) according to reverse power flow of PV system. In order to solve these problems, this paper proposes flexible adoption evaluation algorithm of PV system in distribution system which estimates proper introduction capacity and location of ESS(energy storage system) for keeping customer voltages within allowable voltage limit based on various operating scenarios related with connecting point and capacity of PV system. And also this paper proposes modeling of ESS, SVR(step voltage regulator) and PV system using PSCAD/EMTDC S/W and analyzes characteristics of customer voltages and the adoption ability of PV system in distribution system. From the simulation results, it is confirmed that proposed algorithm is useful for large-scale adoption of PV system in distribution system to maintain customer voltages within allowable voltage limit.