• Title/Summary/Keyword: Flexible AC Transmission System

Search Result 94, Processing Time 0.022 seconds

A Study on Operation Zone of Adaptive Distance Relay on Transmission Line Connected UPFC Between Kangjin and Jangheung (UPFC가 연계 된 강진-장흥 송전선로 보호용 거리계전기의 동작특성에 관한 연구)

  • Lee, Seung-Hyuk;Jung, Chang-Ho;Kim, Jin-O;Jung, Hyun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.305-307
    • /
    • 2003
  • This paper presents an apparent impedance calculation procedure for distance relaying of transmission line involving FACTS (Flexible AC Transmission System) devices, particularly the UPFC (Unified Power Flow Controller), between Kangjin and Jangheung in Korea. With the changes of UPFC's parameters, the measurement and protective range (trip boundaries) of the adaptive distance relay can also be changed. So, it is the most important part in the field of system protection to analyze the operating characteristic of relaying system. The presence of UPFC significantly affects the trip boundaries which are also adversely affected by fault resistance combined with remote end infeed. This paper presents the apparent impedance calculations and the distance relay setting characteristics for faults involving the UPFC in the KEPCO system.

  • PDF

Improvement of Line Protection Methods by Dynamic Analysis on a FACTS-compensated transmission line (FACTS 보상 송전선의 동적 해석을 통한 송전선 보호 방안 개선)

  • Lim Jung-Uk;Runolfsson Thodur
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.12
    • /
    • pp.573-579
    • /
    • 2005
  • Dynamic analysis of a transmission line which is compensated by a FACTS device such as STATCOM, SSSC and UPFC is carried out in this paper and the impacts on conventional line protection methods such as the DCPM (Differential Current Protection Method) and the DPM (Distance Protection Method) are reviewed. A refined DCRM is proposed to detect faults properly regardless of the FACTS operation. The proposed method is applied to a FACTS-compensated line with a variety of faults and is verified by simulation results. An adaptive DPM on a FACTS-compensated line was proposed previously in the literature. In order to emphasize the necessity of the modified DPM, the conventional DPM is applied to a FACTS-compensated system. Significant factors such as fault types, fault locations, and fault resistances as well as FACTS device types are considered for relaying setting.

Characteristic Analysis of Voltage Stability Improvement and Power Factor Correction by STATCOM (STATCOM의 전압안정도개선 및 역률 보상 특성분석)

  • Park, Ji-Yong;Park, Duk-Hee;Han, Byung-Moon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.12
    • /
    • pp.1507-1513
    • /
    • 1999
  • This paper describes simulation and experimental results to analyze the dynamic characteristics of STATCOM, which is connected to the ac system for compensation the power factor and improving the voltage stability. The simulation and experimental results confirm that the scaled model for STATCOM can properly compesate the power factor of the load and regulate the bus voltage at the common connection point.

  • PDF

Development of RTDS model for Sea-Deagu SVC (실시간 디지털 시뮬레이터를 위한 서대구 SVC 모델 개발)

  • Kim, Y.K.;Lee, J.;Yoon, Y.B.;Kim, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.280-282
    • /
    • 2002
  • This paper presents the characteristics and Real Time Digital Simulator(RTDS) model for Seo-deagu Static Var Compensator(SVC) systems installed in 1999. SVC system is a power system controller using power electronics called Flexible AC Transmission Systems (FACTS). RTDS model for Seo-deagu SVC is developed and verified, we recognize to be essential for SVC systems and understand SVC systems through simulation.

  • PDF

1MVA Distribution-STATCON for Flexible AC Transmission System (FACTS) (유연송전 시스템을 위한 1MVA 배전용 동기 조상기)

  • Moon, Gun-Woo;Yoon, Suk-Ho;Park, Yong-Bae;Yoon, Jong-Soo;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.1933-1935
    • /
    • 1997
  • The availability of high power IGBT has led to development of controllable reactive power and harmonics compensation source for use in power transmission system. The paper describes the fundmental operating principles and several application examples. The control technique of reactive power and harmonics compensation for Distribution STATCON is presented, and the computer simulation results are shown to show the effectiveness of tile proposed control technique.

  • PDF

Maximization of Transmission System Loadability with Optimal FACTS Installation Strategy

  • Chang, Ya-Chin;Chang, Rung-Fang
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.991-1001
    • /
    • 2013
  • Instead of building new substations or transmission lines, proper installation of flexible AC transmission systems (FACTS) devices can make the transmission networks accommodate more power transfers with less expansion cost. In this paper, the problem to maximize power system loadability by optimally installing two types of FACTS devices, namely static var compensator (SVC) and thyristor controlled series compensator (TCSC), is formulated as a mixed discrete-continuous nonlinear optimization problem (MDCP). To reduce the complexity of the problem, the locations suitable for SVC and TCSC installations are first investigated with tangent vector technique and real power flow performance index (PI) sensitivity factor and, with the specified locations for SVC and TCSC installations, a set of schemes is formed. For each scheme with the specific locations for SVC and TCSC installations, the MDCP is reduced to a continuous nonlinear optimization problem and the computing efficiency can be largely improved. Finally, to cope with the technical and economic concerns simultaneously, the scheme with the biggest utilization index value is recommended. The IEEE-14 bus system and a practical power system are used to validate the proposed method.

A Study on The Application and The Location of FACTS for Congestion Prob (혼잡해결을 위한 FACTS 기기의 적용과 위치선정)

  • Moon, Jun-Mo;Jung, Yun-Ho;Lee, Kwang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.22-24
    • /
    • 2000
  • As a competition is introduced in the electricity supply industry, a congestion problem arises in the transmission network. The congestion causes the transmission cost to increase. One way to decrease the congestion cost is to control the transmission flow through the installation of FACTS(Flexible AC Transmission system). This paper deals with the optimal site of the FACTS for reducing the congestion cost using a shadow price which is one of the economic signals for the systems. Test results show that the site of the FACTS(UPFC) is optimal to minimize the congestion cost by the proposed algorithm.

  • PDF

The Design and Implementation of TCSC Control Hardware for KERI Simulator (시뮬레이터급 TCSC 제어기 설계 및 구현)

  • Jeon J.H.;Kim K.S.;Kim J.W.;Chun Y.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.158-161
    • /
    • 2003
  • KERI simulator is a analog simulator for power system at KERI power system division lab. It consist of many power system components, which are a 380V 5kVA generators, scale-downed transmission line modules, transformers, switches, PACTS(Flexible AC Transmission System) devices. As a FACTS device module, 20kVA TCSC(Thyristor Controlled Series Compensator) module was designed and implemented. In this paper, we present the design and implementation of TCSC control hardware for KERI simulator

  • PDF

The Design and Implementation of 20kVA TCSC Simulator (20kVA 시뮬레이터급 TCSC 설계 및 제작)

  • Jeon J.H.;Kim K.S.;Kim J.W.;Chun Y.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.154-157
    • /
    • 2003
  • In this study, we design and implement the 20kVA TCSC(Thyrister Controlled Series Compensator) simulator It was tested on the KERI simulator The KERI simulator is a analog simulator for power system at the KERI power system division lab. It consist of many power system components, which are a 380V 5kVA generators, scale-downed transmission line modules, transformers, switches, FACTS(Flexible AC Transmission System) devices. In this paper, we present the design and implementation of 20kVA TCSC simulator and its basic test results.

  • PDF

Optimal Allocation of FACTS Devices Considering both Corrective and Prevenvite Mode (수정모드를 고려한 예방모드에서의 유연송전기기 최적투입계획 관한 연구)

  • Lim, Nam-Kyu;Song, Hwa-Chang;Lee, Byong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.23-25
    • /
    • 2000
  • In recent deregulation and competitive power market environment, electric utilities plan and operate their systems for economic benefit with secure system condition. Flexible AC transmission system(FACTS) technology opens up new opportunities of controlling power and enhancing the usable capacity of present transmission system. This paper presents a method for security constrained optimal allocation of FAETS considering contingencies for the purpose of enhanced system operation. The proposed scheme uses Benders decomposition to account of both corrective and preventive mode.

  • PDF