• Title/Summary/Keyword: Flattening method

Search Result 94, Processing Time 0.023 seconds

A Study on Development of Men's Formal Jacket Pattern by 3D Human Body Scan Data -A Focus on Men's in their Late 30s- (3D 인체데이터를 활용한 남성 정장재킷 패턴개발 연구 -30대 후반 남성을 중심으로-)

  • Shin, Kyung-hee;Suh, Chuyeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.43 no.3
    • /
    • pp.440-458
    • /
    • 2019
  • Based on a 3D body data and pattern comparison analysis, this study developed a formal jacket pattern for men in their late 30s. In order to select the representative type of men in their late 30s, factor analysis and cluster analysis were conducted on data form 319 men, 35 to 39 years old using the anthropometric data from The 7th Size Korea (2015) as the representative body type. The surface of the body surface was developed using a 3D human shape of a male in his 30s in The 6th Size Korea (2010). Then the shape was changed to a flat pattern that confirmed the necessary elements for setting the shape and dimension. Cluster analysis revealed type B as the representative type because it showed the best shape characteristics for men in the late 30s. The drafting method of the final research pattern is as follows. Jacket length: stature/2.5cm, back length: stature/5+8.5cm (constant)], armhole depth: [stature/ 7-1.5cm (constant)], back width: [C/9+9.5cm (constant)]+1cm (ease), front width: [C/9+8.5cm (constant)]+1cm (ease), armscye depth: C/8, front waist darts: 1cm, front closure amount: 2cm.

NEW EVALUATION METHODS FOR RADIAL UNIFORMITY IN NEUTRON TRANSMUTATION DOPING

  • Kim, Hak-Sung;Lim, Jae-Yong;Pyeon, Cheol-Ho;Misawa, Tsuyoshi;Shiroya, Seiji;Park, Sang-Jun;Kim, Myong-Seop;Oh, Soo-Youl;Jun, Byung-Jin
    • Nuclear Engineering and Technology
    • /
    • v.42 no.4
    • /
    • pp.442-449
    • /
    • 2010
  • Recently, the neutron irradiation for large diameter silicon (Si)-ingots of more than 8" diameter is requested to satisfy the demand for the neutron transmutation doping silicon (NTD-Si). By increasing the Si-ingot diameter, the radial non-uniformity becomes larger due to the neutron attenuation effect, which results in a limit of the feasible diameter of the Si-ingot. The current evaluation method has a certain limit to precisely evaluate the radial uniformity of Si-ingot because the current evaluation method does not consider the effect of the Si-ingot diameter on the radial uniformity. The objective of this study is to propose a new evaluation method of radial uniformity by improving the conventional evaluation approach. To precisely predict the radial uniformity of a Si-ingot with large diameter, numerical verification is conducted through comparison with the measured data and introducing the new evaluation method. A new concept of a gradient is introduced as an alternative approach of radial uniformity evaluation instead of the radial resistivity gradient (RRG) interpretation. Using the new concept of gradient, the normalized reaction rate gradient (NRG) and the surface normalized reaction rate gradient (SNRG) are described. By introducing NRG, the radial uniformity can be evaluated with one certain standard regardless of the ingot diameter and irradiation condition. Furthermore, by introducing SNRG, the uniformity on the Si-ingot surface, which is ignored by RRG and NRG, can be evaluated successfully. Finally, the radial uniformity flattening methods are installed by the stainless steel thermal neutron filter and additional Si-pipe to reduce SNRG.

Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료의 다양한 EPID 영상 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Cho, Jeong-Hee;Lee, Jea-Hee;Jung, Jae-Yong;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.451-461
    • /
    • 2015
  • In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$ and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeam$^{TM}$ (Varian), BEAMVIEW$^{PLUS}$ (Siemens), iViewGT (Elekta) and Clinac$^{(R)}$iX (Varian) were used. As for MTF results, TrueBeam$^{TM}$(Varian) flattening filter free(FFF) showed the highest values of $0.46mm^{-1}$ and $1.40mm^{-1}$ for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and $1mm^{-1}DQE$ of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID).

OPTICAL MULTI-CHANNEL INTENSITY INTERFEROMETRY - OR: HOW TO RESOLVE O-STARS IN THE MAGELLANIC CLOUDS

  • Trippe, Sascha;Kim, Jae-Young;Lee, Bangwon;Choi, Changsu;Oh, Junghwan;Lee, Taeseok;Yoon, Sung-Chul;Im, Myungshin;Park, Yong-Sun
    • Journal of The Korean Astronomical Society
    • /
    • v.47 no.6
    • /
    • pp.235-253
    • /
    • 2014
  • Intensity interferometry, based on the Hanbury Brown-Twiss effect, is a simple and inexpensive method for optical interferometry at microarcsecond angular resolutions; its use in astronomy was abandoned in the 1970s because of low sensitivity. Motivated by recent technical developments, we argue that the sensitivity of large modern intensity interferometers can be improved by factors up to approximately 25 000, corresponding to 11 photometric magnitudes, compared to the pioneering Narrabri Stellar Interferometer. This is made possible by (i) using avalanche photodiodes (APD) as light detectors, (ii) distributing the light received from the source over multiple independent spectral channels, and (iii) use of arrays composed of multiple large light collectors. Our approach permits the construction of large (with baselines ranging from few kilometers to intercontinental distances) optical interferometers at the cost of (very) long-baseline radio interferometers. Realistic intensity interferometer designs are able to achieve limiting R-band magnitudes as good as $m_R{\approx}14$, sufficient for spatially resolved observations of main-sequence O-type stars in the Magellanic Clouds. Multi-channel intensity interferometers can address a wide variety of science cases: (i) linear radii, effective temperatures, and luminosities of stars, via direct measurements of stellar angular sizes; (ii) mass-radius relationships of compact stellar remnants, via direct measurements of the angular sizes of white dwarfs; (iii) stellar rotation, via observations of rotation flattening and surface gravity darkening; (iv) stellar convection and the interaction of stellar photospheres and magnetic fields, via observations of dark and bright starspots; (v) the structure and evolution of multiple stars, via mapping of the companion stars and of accretion flows in interacting binaries; (vi) direct measurements of interstellar distances, derived from angular diameters of stars or via the interferometric Baade-Wesselink method; (vii) the physics of gas accretion onto supermassive black holes, via resolved observations of the central engines of luminous active galactic nuclei; and (viii) calibration of amplitude interferometers by providing a sample of calibrator stars.

A Study on the Introduction and Application of Core Technologies of Smart Motor-Graders for Automated Road Construction (도로 시공 자동화를 위한 스마트 모터 그레이더의 구성 기술 소개 및 적용에 관한 연구)

  • Park, Hyune-Jun;Lee, Sang-Min;Song, Chang-Heon;Cho, Jung-Woo;Oh, Joo-Young
    • Tunnel and Underground Space
    • /
    • v.32 no.5
    • /
    • pp.298-311
    • /
    • 2022
  • Some problems, such as aging workers, a decreased population due to a low birth rate, and shortage of skilled workers, are rising in construction sites. Therefore research for smart construction technology that can be improved for productivity, safety, and quality has been recently developed with government support by replacing traditional construction technology with advanced digital technology. In particular, the motor grader that mainly performs road surface flattening is a construction machine that requires the application of automation technology for repetitive construction. It is predicted that the construction period will be shortened if the construction automation technology such as trajectory tracking, automation work, and remote control technology is applied. In this study, we introduce the hardware and software architecture of the smart motor grader to apply unmanned and automation technology and then analyze the traditional earthwork method of the motor grader. We suggested the application plans for the path pattern and blade control method of the smart motor grader based on this. In addition, we verified the performance of waypoint-based path-following depending on scenarios and the blade control's performance through tests.

Various Expression Pattern of Beta-catenin in the Preimplantation Stage of Porcine Embryos

  • Han, Jee-Soo;Koo, Deog-Bon;Shin, Bo-Rami;Lee, Kyung-Kwang;Han, Yong-Mahn
    • Proceedings of the KSAR Conference
    • /
    • 2003.06a
    • /
    • pp.56-56
    • /
    • 2003
  • Beta-catenin is very important in early development including involvement in cell adhesion, cell signaling, and developmental fate specification. Cell-cell interaction is an important process during mammalian embryonic development. In preimplantation embryos, embryonic compaction is the process of increased cellular flattening and adhesion of junctional complexes and results in a polarized distribution. Beta-catenin is associated with embryonic compaction in mammals. Here, we examined the relationship between beta-catenin expression and compaction in porcine embryos derived from in vitro fertilization. First of all, we investigated beta-catenin expression in each embryonic developmental stage and also focused on expression pattern according to full, partial and non-compaction at morula stage. We used the immunocyto-chemical method in this research. To confirm compaction affects on the embryonic development, we compared between compaction and developmental rates to the blastocyst. The result showed that compaction and non-compaction rates were 14.6% and 63.8% at 4 days after IVF, respectively The developmental rates to the blastocyst and their total cell number were 50.9% vs 36.4% and 41.4$\pm$11.5 vs 26.8$\pm$12.7 in compaction and non-compaction groups. Although no difference was detected in the ratio of ICM to total cells between two groups, total cell number of the blastocysts in compaction group was superior to that of the blastocysts in non-compaction group (P<0.05). Expression of beta-catenin appeared in the boundary of membrane surface between blastomeres in 2- and 4-cell stage, and observed irregular pattern from 8-cell to blastocyst stage. We also investigated beta-catenin expression pattern according to the degree of compaction in the 3 groups; full, partial (>50%) and non-compaction. The expression signal in fully compacted embryos was stronger than those of partial and non-compacted embryos. Especially, beta-catenin expression appeared various patterns in morula stage suggesting the aberrant distribution of beta-catenin is affected by compaction patterns. Our results suggest that abnormal beta-catenin expression was affected by embryo quality and further development in porcine embryos in vitro.

  • PDF

Electrical and Rheological Behaviors of VGCF/Polyphenylene Sulfide Composites (기상성장 탄소섬유/폴리페닐렌설파이드 복합체 제조 및 전기적$\cdot$유변학적 거동)

  • Noh, Han-Na;Yoon, Ho-Gyu;Kim, Jun-Kyung;Lee, Hyun-Jung;Park, Min
    • Polymer(Korea)
    • /
    • v.30 no.1
    • /
    • pp.85-89
    • /
    • 2006
  • The effect of vapor grown carbon fiber (VGCF) contents on electrical and rheological properties of VGCF filled polyphenylene sulfide (PPS) composites prepared through melt mixing using a twin screw exruder was studied. This method was proved to be quite effective to produce good dispersion of VGCF in the matrix even for highly filled PPS. From the dependence of the electrical conductivity on VGCF content, the percolation phenomena began to occur above $10\;wt\%$. While there is only a marginal increase of viscosity for 1 and $5\;wt\%$ VGCF filled PPS, the composites containing $10\;wt\%$. While VGCF showed abrupt increase in viscosity as well as flattening of frequency vs modulus curve, indicating a transition from a liquid-like to a solid-like behavior due to the creation of VGCF network. This result agrees well to the fact that the network formation in the composite can be composite by rheological property dependence on filler content as well as by electrical conductivity measurement.

CORRECTION OF SECONDARY CLEFT-LIP NASAL DEFORMITY BY USING ABBE FLAP: REPORT OF 4 CASES (Abbe 피판을 이용한 이차성 구순열비변형의 교정 4예)

  • Ryu, Sun-Youl;Kim, Tae-Hee;Hwang, Ung;Koo, Hong;Kwon, Jun-Kyung;An, Jin-Suk;Park, Hong-Ju
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.1
    • /
    • pp.55-62
    • /
    • 2007
  • Radical paring of the cleft edge during primary cleft lip operation or repeated secondary surgeries can result in tightness of the upper lip. In case, the degree of the resulting side-to-side tension is very severe, the possibility of a lip switch flap must be considered. When the lip tightness accompanies a loss of more than two-thirds of the Cupid's bow, an Abbe flap is an alternative. The disadvantages of Abbe flap are scar formation on the lower lip, design of incision line on the upper lip, disharmony of colors, and the dysfunction of the orbicularis muscle. These problems have been recognized in the literature and extreme discretion has been advised in its application. We experienced four cases of Abbe flap operation which were designed differently to correct the secondary unilateral or bilateral cleft-lip nasal deformities. The Abbe flap operations resulted in removal of the scars and tightness of the upper lip, reconstruction of the Cupid's bow, lengthening of the columella, and therefore secondary cleft-lip nasal deformity could be corrected. It is thought that carefully applied Abbe flap is an appropriate method to relieve horizontal tightness or flattening of the upper lip which occured after primary operation of cleft lip.

Study on 6 MV Photon beam Dosimetry by Asymmetric Collimator Variation of Linear Accelerator (6MV 선형가속기의 비대칭 조사야의 변화에 따른 선량분포)

  • Yoon, Joo-Ho;Lee, Chul-Soo;Yum, Ha-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.91-104
    • /
    • 2000
  • Recently linear accelerator in radiation therapy in asymmetric field has been easily used since the improvement and capability of asymmetrical field adjustment attached to the machine. It has been thought there have been some significant errors in dose calculation when asymmetrical radiation fields have been utilized in practice of radiation treatments if the fundamental data for dose calculation have been measured in symmetrical standard fields. This study investigated how much the measured data of dose distributions and their isodose curves are different between in asymmetrical and symmetrical standard fields, and how much there difference affect the error in dose calculation in conventional method measured in symmetrical standard field. The distributions of radiation dose were measured by photon diode detector in the water phantom (RFA-300P, Scanditronix, Sweden) as tissue equivalent material on utilization of 6 MV linear accelerator with source surface distance (SSD) 1000 mm. The photon diode detector has the velocity of 1 mm per second from water surface to 250 mm depth in the field size of $40mm{\times}40mm\;to\;250mm{\times}250mm\;symmetric\;field\;and\;40mm{\times}20mm\;to\;250mm{\times}125mm$ asymmetrical fields. The measurements of percent depth dose (PDD) and subsequent plotting of their isodose curves were performed from water surface to 250mm dmm from Y-center axis in $100mm{\times}50mm$ field in order to absence the variability of depth dose according to increasing field sizes and their affects to plotted isodose curves. The difference of PDD between symmetric and asymmetric field was maximum $4.1\%\;decrease\;in\;40mm{\times}20mm\;field,\;maximum\;6.6\%\;decrease\;in\;100mm{\times}50mm\;and\;maximum\;10.2\%\;decrease\;200mm{\times}100mm$, the larger decrease difference of PDD as the greater field size and as greater the depth, The difference of PDD between asymmetrical field and equivalent square field showed maximum $2.4\%\;decrease\;in\;60mm{\times}30mm\;field,\;maximum\;4.8\%\;decrease\;in\;150mm{\times}75mm\;and\;maximum\;6.1\%\;decrease\;in\;250mm{\times}125mm$, and the larger decreased differenced PDD as the greater field size and as greater the depth, these differences of PDD were out of $5\%$ of dose calculation as defined by international Commission on radiation unit and Measurements(ICRU). In the dose distribution of asymmetrical field (half beam) the plotted isodose curves were observed to have deviations by decreased PDD as greater as the blocking of the beam moved closer to the central axis, and as the asymmetrical field increased by moving the block 10 mm keeping away from the central axis, the PDD increased and plotted isodose curves were gradually more flattened, due to reduced amount of the primary beam and the fraction of low energy soft radiations by passing thougepth in asymmetrical field by moving independent jaw each 10 h beam flattening filter. As asymmetrical radiation field as half beam radiation technique is used, the radiation dosimetry calculated in utilizing the fundamental data which measured in standard symmetrical field should be converted on bases of nearly measured data in asymmetrical field, measured beam data flies of various asymmetrical field in various energy and be necessary in each institution.

  • PDF

Radiation-Induced Apoptosis of Lymphocytes in Peripheral Blood (말초혈액 내 림프구의 방사선에 의한 아포프토시스)

  • Oh, Yoon-Kyeong;Lee, Tae-Bum;Nam, Taek-Keun;Kee, Keun-Hong;Choi, Cheol-Hee
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.75-81
    • /
    • 2003
  • Purpose : This study quantitatively evaluated the apoptosis In human peripheral blood lymphocytes using flow cytometry, and investigated the possibility of using this method, with a small amount of blood, and the time and dose dependence of radiation-induced apoptosls. Materials and Methods : Peripheral blood lymphocyes were isolated from the heparinized venous blood of 11 healthy volunteers, 8 men and 3 women, with each 10 ml of blood being divided Into IS samples. The blood lymphocytes were Irradiated using a linear accelerator at a dose rate of 2.4 Gy/min, to deliver doses of 0.5, 1, 2 and S Gy. The control samples, and Irradiated cells, were maintained in culture medium for 24, 48 and 72 hours fellowing the Irradiation. The number of apoptotic cells after the in vitro X-irradiation was measured by flow cytometry after Incubation periods of 24, 48 and 72 hours. We also observed the apoptotic cells using a DNA fragmentation assay and electron microscopy. Results : The rate oi spontaneous apoptosis increased in relation to the time interval following irradiation (1.761 ${\pm}$0.161, 3.563${\pm}$0.554, 11.098${\pm}$2.849, at 24, 48, and 72 hours). The apoptotli cells also increased In the samples irradiated with 0.5, 1, 2 and 5 Gy, In a radiation dose and time interval after Irradiation manner, with the apoptosls being too great at 72 hours after Irradiation. The dose-response curves were characterized by an Initial steep Increase In the number of apoptotic cells for Irradiation doses below 2 Gy, with a flattening of the curves as the dose approached towards 5 Gy. Conclusion :The flow cytometric assay technique yielded adequate data, and required less than 1 mL of blood. The time and dose dependence of the radiation-induced apoptosis, was also shown. It is suggested that the adequate time Interval required for the evaluation of apoptosis would be 24 to 48 hours after blood sampling.