• 제목/요약/키워드: Flat Tube

검색결과 258건 처리시간 0.035초

일체형원자로 인쇄기판형 증기발생기 열수력학적 설계 (Thermal-hydraulic Design of A Printed-Circuit Steam Generator for Integral Reactor)

  • 강한옥;한훈식;김영인
    • 한국유체기계학회 논문집
    • /
    • 제17권6호
    • /
    • pp.77-83
    • /
    • 2014
  • The vessel of integral reactor contains its major primary components such as the fuel and core, pumps, steam generators, and a pressurizer, so its size is proportional to the required space for the installation of each component. The steam generators take up the largest volume of internal space of reactor vessel and their volumes is substantial for the overall size of reactor vessel. Reduction of installation space for steam generators can lead to much smaller reactor vessel with resultant decrease of overall cost for the components and related facilities. A printed circuit heat exchanger is one of the compact types of heat exchangers available as an alternative to conventional shell and tube heat exchangers. Its name is derived from the procedure used to manufacture the flat metal plates that form the core of the heat exchanger, which is done by chemical milling. These plates are then stacked and diffusion bonded, converting the plates into a solid metal block containing precisely engineered fluid flow passages. The overall heat transfer area and pressure drops are evaluated for the steam generator based on the concept of the printed circuit heat exchanger in this study. As the printed circuit heat exchanger is known to have much larger heat transfer area density per unit volume, we can expect significantly reduced steam generator compared to former shell and tube type of steam generator. For the introduction of new steam generator, two design requirements are considered: flow area ratio between primary and secondary flow paths, and secondary side parallel channel flow oscillation. The results show that the overall volume of the steam generator can be significantly reduced with printed circuit type of steam generator.

NACA0012 날개 위의 천이 경계층에 관한 실험적 연구 (An experimental study on the transitional boundary layer developing on NACA0012 airfoil)

  • 강신형;신상철;이현구
    • 대한기계학회논문집B
    • /
    • 제20권5호
    • /
    • pp.1689-1699
    • /
    • 1996
  • A study on the transitional boundary layer with arbitrary pressure gradient under various upstream conditions is very important for engineering applications like the performance predictions of the turbomachineries under various and strong disturbances. Experimental data on the transitional boundary layer for real cascades of the turbomachinery are rare because of difficulties in boundary layer experiments. Flow on NACA0012 airfoil is more similar to the real case than that on the flat plate with which many researches are done. The data of the transitional flow on the airfoil could be used to verify or to develop a turbulence model for numerical simulations. The experiment was performed with two cases of Reynolds number at a=0$^{0}$ and one case of Reynolds number at a=5$^{0}$ . The measured data are the transition length and the wall shear stresses. These two characteristic values are measured within 25%~90% of the airfoil chord by Computation Preston tube Method(CPM) proposed by Nitsche et al.(1983). At a=0$^{0}$ , transition occured at 70% and 55% of chord length when R $e_{c}$=6*10$^{5}$ and 8* 10$^{5}$ , respectively. It started when R {\theta}=500 regardless of R $e_{c}$, and ended when R {\theta}=750, and 850 respectively. The transition length was 15~20% of the chord length. At a=5$^{0}$ (R $e_{c}$=6*10$^{5}$ ), boundary layer on the pressure side does not undergo transition, but on the suction side transition occured at .chi.$_{c}$/c=0.16 and ended at .chi.$_{c}$/c=0.22.c//c=0.22./c=0.22.c//c=0.22.

In Vitro Development of Porcine Parthenogenetic Embryos under the Oil-free Culture System

  • Park, Sang-Kyu;Choi, Young-Ju;Roh, Sang-Ho
    • 한국수정란이식학회지
    • /
    • 제25권4호
    • /
    • pp.259-262
    • /
    • 2010
  • Optimization of the preimplantation mammalian embryo culture condition was widely focused on refining medium composition under the name of chemically defined media. However, recent research revealed that the alteration of physical environment can be a crucial factor to a successful embryo development. In this study, under the same embryo density, a novel culture device named oil-free micro tube culture (MTC) system was evaluated using porcine parthenogenetic embryos. The activated oocytes were placed into the 0.2 ml thin-wall flat cap PCR tube and cultured to the blastocyst stage. As a preliminary step, embryo density and culture medium volume were optimized under a standard drop culture system. The optimal embryo density range for in vitro culture was 0.5 embryos per ${\mu}l$ in $20\;{\mu}l$ drop (20.5%) and 1.0 embryos per ${\mu}l$ in $10\;{\mu}l$ drop (20.6%). Based on these results, we compared drop culture system and 'MTC' system in terms of the developmental rate to the blastocyst stage. In $20\;{\mu}l$ medium volume, the 'MTC' system showed similar blastocyst formation rate when compared with drop culture system (20.2% versus 20.5%, respectively) while the 'MTC' system showed lower blastocyst formation rate than drop culture system in $10\;{\mu}l$ one (12.7% versus 20.0%, respectively). Therefore the $20\;{\mu}l$ MTC system may be an alternative incubation system for short-distance embryo transport without carrying the $CO_2$ incubator and this provides novel embryo culture device to clinical veterinary embryologists.

디지털흉부X선촬영에서 검출기 방식에 따른 최적의 노출조건 (Optimal Exposure Conditions according to Detector Type in Chest Digital Radiography)

  • 이원정
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.213-221
    • /
    • 2015
  • The aim of this study was to set up the optimal exposure condition according to detector type considering image quality (IQ) with radiation dose in chest digital radiography. We used three detector type such as flat-panel detector (FP) and computed radiography (CR), and charge-coupled device (CCD). Entrance surface dose (ESD) was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image informations. Standard exposure condition using each institution was 117 kVp-AEC at FP and 117 kVp-8 mAs at CR, and 117 kVp-8 mAs at CCD. Statistical analysis was performed by One way ANOVA (Dunnett T3 test) using SPSS ver. 19.0. In FP, IQ scores were not significant difference between 102 kVp-4 mAs and 117 kVp-AEC (28.4 vs. 31.1, p=1.000), even though ESD was decreased up to 50% ($62.3{\mu}Gy$ vs. $125.1{\mu}Gy$). In CR, ESD was greatly decreased from 117 kVp-8 mAs to 90 kVp-8 mAs without significant difference of IQ score (p=1.000, 24.6 vs. 19.5). In CCD, IQ score of 117 kVp-8 mAs was similar with 109 kVp-8 mAs (29.6 vs. 29.0), with decreasing from $320.8{\mu}Gy$ to $284.7{\mu}Gy$ (about 11%). We conclude that optimal x-ray exposure condition for chest digital radiography is 102 kVp-4 mAs in FP and 90 kVp-8 mAs in CR, and 109 kVp-8 mAs in CCD.

C-arm CT의 필수 성능평가 기준 마련을 위한 연구 (A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography)

  • 김은혜;박혜민;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

전류 면적차를 이용한 아크 센서의 용접선 추적에 관한 연구 (A Study of Seam Tracking by Arc Sensor Using Current Area Difference Method)

  • 김용재;이세헌;엄기원
    • Journal of Welding and Joining
    • /
    • 제14권6호
    • /
    • pp.131-139
    • /
    • 1996
  • The response of the arc sensor using the welding current and/or welding voltage as its outputs has been obtained by the analysis and/or experiments of the static characteristics of arc sensor. But in order to improve the reliability of arc sensor, it is necessary to know its dynamic characteristics. So in this paper, it is presented the dynamic model of arc sensor including the power source, arc voltage, electrode burnoff rate, and wire feed rate. A numerical simulation of the dynamic model of arc sensor was implemented, computing the welding current with input of CTWD. The results of computer simulations and experiments of $CO_2$arc welding showed that a linear relationship between weaving center - weld line distance and current area difference was established. Additionally, a real-time weld seam tracking system interfaced with industrial welding robot was constructed, the result of the weld seam tracking experiment for weld line with an initial offset error of 5$^{\circ}$was good.

  • PDF

아크형 날개를 이용한 항력식 수직축 소형 풍력 터빈 설계 (Design of Drag-type Vertical Axis Miniature Wind Turbine Using Arc Shaped Blade)

  • 김동건;김문경;차득근;윤순현
    • 한국유체기계학회 논문집
    • /
    • 제9권2호
    • /
    • pp.7-12
    • /
    • 2006
  • This study is to develop a system of electric power generation utilizing the wind resources available in the domestic wind environment. We tested drag-type vortical wind turbine models, which have two different types of blades: a flat plate and circular arc shape. Through a performance test, conditions of maximum rotational speed were found by measuring the rpm of wind turbine. The rotational speed was measured by a tachometer in a wind tunnel and the tunnel wind speed was by using a pilot-static tube and a micro manometer. The performance test for a prototype was accomplished by calculating power, power coefficient, torque coefficient from the measurement of torque and rpm by a dynamometer controller From the measurements for miniature turbine models with two different blades, the circular arc shape was found to Produce a maximum rotational speed for the same wind velocity condition. Based on this result, the prototype with the circular arc blade was made and tested. We found that it produces 500W at the wind velocity of 10.8 m/s and the power coefficient was 20%.

Prediction of Wall Shear Stresses in Transitional Boundary Layers Using Near-Wall Mean Velocity Profiles

  • Jeon, Woo-Pyung;Shin, Sung-Ho;Kang, Shin-Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • 제14권11호
    • /
    • pp.1305-1318
    • /
    • 2000
  • The local wall shear stress in transitional boundary layer was estimated from the near-wall mean velocity data using the principle of Computational Preston Tube Method(CPM). The previous DNS and experimental databases of transitional boundary layers were used to demonstrate the accuracy of the method and to provide the applicable range of wall unit y(sup)+. The skin friction coefficients predicted by the CPM agreed well with those from previous studies. To reexamine the applicability of CPM, near-wall hot-wire measurement were conducted in developing transitional boundary layers on a flat plate with different freestream turbulence intensities. The intermittency profiles across the transitional boundary layers were reasonably obtained from the conditional sampling technique. An empirical correlation between the representative intermittency near the wall and free parameter K$_1$of the extended wall function of CPM has been newly proposed using the present and other experimental data. The CPM has been verified as a useful tool to measure the wall shear stress in transitional boundary layer with reasonable accuracy.

  • PDF

플라즈마 디스플레이의 소음 저감 연구 (Study on Noise Reduction of Plasma Display Panel)

  • 박대경;권해섭;장동섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.693-698
    • /
    • 2002
  • For the evaluation of the plasma display panel (PDP)'s noise, vibration and sound characteristics of fanless PDP are measured and investigated. PDP is a type of two-electrode vacuum tube which operates on the same principle as a household fluorescent light. An inert gas such as argon or neon is injected between two glass plates on which transparent electrodes have been formed, and the glass is illuminated by generating discharge. For this discharge, both high voltage and currents are needed and cause an acoustic noise. We investigated the noise characteristics connected with both a electromagnetic elements from SMPS to panel through X, Y and logic board, and a mechanical elements form panel to case through transfer path which related with vibration and heat. To reduce the noise of PDP, a discharge pulse memory design related with both higher brightness and lower power consumption is important and mechanical characteristics connected with dissipation process of both heat and vibration generated by panel discharge must be investigated.

  • PDF

고온 소결형 그라비어 오프셋용 Ag 페이스트의 물성 연구 (A Study on Properties on High Temperature Sintering Gravure Off-set Ag Paste)

  • 박창원;황보혁;조정우;남수용
    • 한국인쇄학회지
    • /
    • 제29권2호
    • /
    • pp.71-82
    • /
    • 2011
  • Electronic display markets has been developed. The cathode ray tube of brown form recently celebrated their 100th by first display. Also LCD of flat form recently celebrated their 25th by second display and it has advantage of small volume, lower consumption power. But FPD has problem that is property of brittle and noncarrying by glass substrate. Therefore the arrival of portable electronics devices has put an increasing premium on durable, lightweight and inexpensive display components. It is flexible display by third display. Also electronics field such as printed wiring board, RFID, membrane switch prefer flexible display. The conductive pattern can be used mostly in field of electronic displays and electronics. This manufacture of conductive pattern in present used is screen printing. The the conductive pattern. It has advantages of flexibility, high conductivity, drying in low temperature, good conductivity. screen printing has problem that is low productivity and use not flexible substrate because of high fire temperature. This study was developed novel method to form the conductive pattern. It has advantages of flexibility, high conductivity, drying in low temperature, good conductivity.