• Title/Summary/Keyword: Flat Panel

Search Result 750, Processing Time 0.027 seconds

A Integrated Circuit Design of DC-DC Converter for Flat Panel Display (플랫 판넬표시장치용 DC-DC 컨버터 집적회로의 설계)

  • Lee, Jun-Sung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.10
    • /
    • pp.231-238
    • /
    • 2013
  • This paper describes a DC-DC converter IC for Flat Panel Displays. In case of operate LCD devices various type of DC supply voltage is needed. This device can convert DC voltage from 6~14[V] single supply to -5[V], 15[V], 23[V], and 3.3[V] DC supplies. In order to meet current and voltage specification considered different type of DC-DC converter circuits. In this work a negative charge pump DC-DC converter(-5V), a positive charge pump DC-DC converter(15V), a switching Type Boost DC-DC converter(23V) and a buck DC-DC converter(3.3V). And a oscillator, a thermal shut down circuit, level shift circuits, a bandgap reference circuits are designed. This device has been designed in a 0.35[${\mu}m$] triple-well, double poly, double metal 30[V] CMOS process. The designed circuit is simulated and this one chip product could be applicable for flat panel displays.

The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT (상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: With the demand of SPECT/CT increasing, the interest in complex diagnostic information of CT is rising along with the expansion of various studies on potential performance value. But the study on reduction of exposure dose generated by CT is not being conducted enough. Therefore, in this study, the goal is to identify how much dose reduction exists when performing the extremity bone SPECT/CT using the flat-panel CT. Materials and Methods: The extremity bone SPECT/CT was performed with two equipments -BrightView XCT (Philips Healthcare, Cleveland, USA) and Brilliance 16 CT (Philips Healthcare, Cleveland, USA)-to identify the exposed dose and image quality resulted by changing scan parameter (mAs) applying for both equipment respectively. The noise value of image and spatial resolution were measured with AAPM CT phantom. Tube voltage (kVp) was fixed to 120 kVp, tube current (mAs) calculated at different mA (20, 30, 40, 50, 60, 70, 80) was applied to both equipments respectively. DLP (dose length product) were calculated at the same distance at respective mAs. Also, we acquired images and % contrast with NEMA IEC body phantom to confirm the effect on image. The output of statistics was analyzed by SPSS ver.18. Results: Regarding AAPM phantom, the noise decreased as the tube current (mAs) increased and flat-panel had less noise than Helical CT. This difference increased at lower dose exposure. As to the evaluation of spatial resolution, we can differentiate the space up to 0.75 mm with both equipments. With scan parameter (mA) growing, the value of DLP increased up to 54-216 mGy cm at flat-panel CT and up to 177-709 mGy cm at Helical CT. Regarding NEMA IEC body phantom, same sphere with varied parameter (mA) shows that similar results. Conclusion: There is no significant differences of image quality in both flat-panel and Helical CT when the scan parameter (mA) is changed respectively. Moreover, we can identify the reduction of exposure dose and confirm %contrast analysis value with maintaining image quality. Therefore, at the extremity bone SPECT/CT requiring high spital resolution without the wide ROI, the flat-panel CT is considered to be more useful and it expected to result in the similar image quality with lower exposure dose compared to Helical CT. Additionally, through this study, we expect to help the reduction of the unnecessary exposure dose.

  • PDF

Alternatives to Enhance Flat Slab Ductility

  • Husain, Mohamed;Eisa, Ahmed S.;Roshdy, Ramy
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.1
    • /
    • pp.161-169
    • /
    • 2017
  • Flat slab systems are vastly used in multi-story buildings because of their savings in story height and construction time, as well as for their flexibility in architectural remodeling. However, they frequently suffer brittle punching-shear failure around columns, especially when subjected to lateral loads. Therefore, seismic codes labeled flat slabs as non-ductile systems. This research goal is investigating some construction alternatives to enhance flat slab ductility and deformability. The alternatives are: adding different types of punching-shear reinforcement, using discreet fibers in concrete mixes, and increasing thickness of slab around columns. The experimental study included preparation and testing of seven half-scale interior slab-column connections up to failure. The first specimen is considered a reference, the second two specimens made of concrete mixes with different volumetric ratios of polymer fibers. Another three specimens reinforced with different types of punching-shear reinforcement, and the last specimen constructed with drop panel of inverted pyramidal shape. It is found that using the inverted pyramid-shape drop panel of specimen, increases the punching-shear capacity, and the initial and the post-cracking stiffnesses. The initial elastic stiffnesses are different for all specimens especially for the slab with closed stirrups where it is experienced the highest initial stiffness compared to the reference slab.

The Research of Electrical and Optical Properties for 24″ Flat Panel-Florescent Lamp (24″평판형광램프에 관한 전기적광학적특성연구)

  • 김수용;박승곤
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.527-530
    • /
    • 2001
  • In this paper, the basic characteristics of flat fluorescent lamp using ultraviolet generate from gas discharge and powder type electrolyminescent display(P-ELD) using a phenomenon of the light emission eaused by the electrical field applied to phosphor are studied. The lamp is a simple structure with insulator layer, phosphor layer, and gas gap. Current(displacement current + discharge current) in flat fluorescent lamp using.

  • PDF

Recovery of Indium for the Recycling of End-of-life Flat Panel Display Devices (폐 디스플레이 재활용을 위한 인듐 회수기술)

  • Uhm, Sunghyun;Cho, Sungsu;Lee, Sooyoung
    • Applied Chemistry for Engineering
    • /
    • v.26 no.4
    • /
    • pp.389-393
    • /
    • 2015
  • Recovery of indium from secondary sources have been attracting over years not only because of increasing demand together with development of flat panel display industry but also industrial criticality of indium. Applied technology to recover indium for recycling of end-of-life FPD devices can be broadly divided into three major steps, disassembly or dismantling, enrichment or upgrading, and refining or purification. In addition, advanced technology such as zone-refining can be employed for ultra-high purity products. In this mini-review, we present currently applied technologies for recovery of indium and the outlook for total recycling of FDP devices.

Evaluation of the 256ch Flat Panel PS-PMT on Positioning Image Histogram for PET

  • Orita, Narimichi;Murayama, Hideo;Kawai, Hideyuki;Inadama, Naoko;Umehara, Takaya;Kasahara, Takehiro;Tsuda, Tomoaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.324-327
    • /
    • 2002
  • For a next generation PET that realizes high sensitivity and high resolution, we proposed a design of a depth of interaction detector. A unit of the detector is constructed of four stages rectangular blocks of 2 by 2 Gd$_2$SiO$\sub$5/: Ce (GSO) crystal array optically coupled to position sensitive photomultiplier tube (PS-PMT). The 256ch flat panel PS-PMT is under development by Hamamatsu Photonics K.K., JAPAN. It has large cathode area, 51.7 by 51.7 mm$^2$, and the ratio of the effective area to external size is about 90%. The feature will contribute high packing fraction, accordingly high sensitivity. The 256 anodes are arranged in 16 by 16 at intervals of 3.0 mm. So as to evaluate the detector capability for identifying crystal of interaction, we got positioning image histograms with coupling a 16 by 5 array of GSO crystals, 2.9 by 2.9 by 7.5 mm$^3$, to the PS-PMT by irradiating a gamma ray uniformly from a point source. Flat panel PS-PMT is a new promising device for PET. We need to evaluate it if its performance is sufficiency. The performance was compared to the one with a 16ch PS-PMT.

  • PDF

Quartz Megasonic System for Cleaning Flat Panel Display (평판디스플레이 세정 용 Quartz 메가소닉 시스템)

  • Kim, Hyunse;Lee, Yanglae;Lim, Euisu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.12
    • /
    • pp.1107-1113
    • /
    • 2014
  • In this article, the megasonic cleaning system for cleaning micro/nano particles from flat panel display (FPD) surfaces was developed. A piezoelectric actuator and a waveguide were designed by finite element method (FEM) analysis. The calculated peak frequency value of the quartz waveguide was 1002 kHz, which agreed well with the measured value of 1003 kHz. The average acoustic pressure of the megasonic cleaning system was 43.1 kPa, which is three times greater than that of the conventional type of 13.9 kPa. Particle removal efficiency (PRE) tests were performed, and the cleaning efficiency of the developed system was proven to be 99%. The power consumption of the developed system was 64% lower than that of the commercial system. These results show that the developed megasonic cleaning system can be an effective solution in particle removing from FPD substrate with higher energy efficiency and lower chemical and ultra pure water (UPW) consumption.

Self-Reference PCSR-G Method for Detecting Defect of Flat Panel Display (평판 디스플레이 결함 검출을 위한 자기 참조 PCSR-G 기법)

  • Kim, Jin-Hyung;Lee, Tae-Young;Ko, Yun-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.3
    • /
    • pp.312-322
    • /
    • 2015
  • In this paper a new defect detection method for flat panel display that does not require any separately prepared reference images and shows robustness against problems with regard to pixel tolerance and nonuniform illumination condition is proposed. In order to perform defect detection under any magnification value of camera, the proposed method automatically obtains the value of pattern interval through an image analysis. Using the information for pattern interval, an advanced PCSR-G method presented in this paper utilizes neighboring patterns as its reference images instead of utilizing any separately prepared reference images. Also this paper proposes a scheme to improve the performance of the conventional PCSR-G method by extracting and applying additional information for pixel tolerance and intensity distribution considering the value of pattern interval. Simulation results show that the performance of the proposed method utilizing pixel tolerance and intensity distribution is superior to that of the conventional method. Also, it is proved that the proposed method that is implemented using parallel technique based on GPGPU can be applied to real system.

Scale-up of Flat Panel Photobioreactor considering Hydrodynamics (수력학을 고려한 평판형 광생물 반응기의 스케일업에 관한 연구)

  • Kim, Gwang-Ho;Lee, Dong-Woon;Jeong, Sang-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.1
    • /
    • pp.48-56
    • /
    • 2018
  • Due to the growing concerns of energy resource depletion and environmental destruction, the mass production of microalgae has been studied. The scale-up of a photobioreactor (PBR) is required for the mass production of biomass. In this paper, the geometric parameters and oxygen transfer rate (OTR) are considered, to scale up a flat panel photobioreactor (FP PBR). The PBR is designed using the goal-driven optimization (GDO) method to accomplish the scale-up. The local sensitivity of each output parameter with respect to the input parameter is analyzed through the design of experiment (DOE), and the design candidates are evaluated with the screening sampling method. The volumetric mass transfer coefficient is measured by the dynamic method.

Intelligent Load Distribution of Two Cooperating Robots for Transporting of Large Flat Panel Displays

  • Cho, Hyun-Chan;Kim, Doo-Yong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.2 s.11
    • /
    • pp.25-32
    • /
    • 2005
  • This paper proposes a method for the intelligent load distribution of two cooperating robots(TCRs) using fuzzy logic. The proposed scheme requires the knowledge of the robots' dynamics, which in turn depend upon the characteristics of large flat panel displays(LFPDs) carried by the TCRs. However, the dynamic properties of the LFPD are not known exactly, so that the dynamics of the robots, and hence the required Joint torque, must be calculated for nominal set of the LFPD characteristics. The force of the TCRs is an important factor in carrying the LFPD. It is divided into external force and internal force. In general, the effects of the internal force of the TCRs are not considered in performing the load distribution in terms of optimal time, but they are essential in optimal trajectory planning; if they are not taken into consideration, the optimal scheme is no longer fitting. To alleviate this deficiency, we present an algorithm for finding the internal-force (actors for the TCRs in terms of optimal time. The effectiveness of the proposed system is demonstrated by computer simulations using two three-joint planner robot manipulators.

  • PDF