• Title/Summary/Keyword: Flashover Voltage

Search Result 162, Processing Time 0.032 seconds

The Effect of the Non Soluble Industrial Dust on the Electrical Properties of Distribution Porcelain Suspension Insulators (비용해성 산업용 분진이 배전용 자기제 현수애자의 전기적 특성에 미치는 영향)

  • Kim, Chan-Young;Song, Il-Keun;Kim, Ju-Yong;Han, Jae-Hong;Kim, Dong-Myung;Lee, Byung-Sung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.4
    • /
    • pp.182-189
    • /
    • 2001
  • In this paper, the distribution suspension porecelain insulators which had been used for long periods in the contaminated area were evaluated. The contaminated area is close to the sea and in the high density of industries. The heavily contaminated domestic and imported insulators were investigated by using electrical characteristics, such as power-frequency dry flashover voltage, power-frequency wet, flahover voltage, and leakage current. Also, these electrical results were compared with the contaminants on the surface. From these analysis, we found that the contamination from the industrial dust, only slightly decreased flashover voltage and increased leakage current. Therefore, the electrical properties of insulators used for 30 years in the area of coast and industrial complex were not much changed.

  • PDF

Tracking Resistance of Epoxy Mold Insulating Materials by the Rotating Wheel Dip Test (회전윤법에 의한 에폭시 몰드 절연재료의 내트래킹성 평가)

  • Cho, Han-Goo;Yun, Mun-Su;Park, Yang-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1590-1592
    • /
    • 2000
  • The time to tracking breakdown of treated filled specimen is longer than untreated filled specimen. And, after the RWDT, the surface of specimen by adding untreated filler appeared heavy erosion. It was found that the addition to surface treated filler. the better tracking resistance. In the RWDT, the breakdown specimen is not affected by the dry flashover voltage. despite the fact that the surface degradation of tracking test has different state on each specimen. This suggests that wet flashover voltage play an important role in evaluating of tracking and erosion on the surface degradation in tracking test. And, the flashover voltage of specimen under wet conditions are greatly affected by the salt concentration and degree of degradation by the RWDT. Because of hydrophobicity and degree of degradation by the RWDT, the flashover voltage of treated filled specimen is higher than that of untreated filled specimen. Different types of specimen may have different hydrophobicity and their surface state under contaminated conditions may not be the same. It is assumed that this phenomenon is related to the decrease in hydrophobicity of the surface of the materials.

  • PDF

A Review of the Flashover Performance of High Voltage Insulators Constructed with Modern Insulating Materials

  • Khatoon, Shabana;Khan, Asfar Ali;Singh, Sakshi
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.5
    • /
    • pp.246-249
    • /
    • 2017
  • Pollution flashover of outdoor insulators is a common risk, which affects the safe operation of overhead transmission networks. Early electrical power systems, which feature insulators made from ceramic materials have been used all over the world with good performance. At present, non-ceramic insulators are in common use, as a result of their good electrical as well as mechanical properties. The aim of this paper is to discuss and compare the flashover performance of insulators typically used in power lines, such as, porcelain, ethylene-propylene-diene-monomer (EPDM) rubber, room temperature vulcanized (RTV) and high temperature vulcanized (HTV) coated silicone rubber. The effect of various parameters, including the severity of pollution, ice accumulation, and shade profile, are considered.. From the studies reviewed it was concluded that there is a distinct difference in the flashover voltages of different types of insulators, and the silicone provides the best flashover performance of all insulating materials.

A Study on the Characteristics of DC Flashover with Floating Metallic Objects in Unipolar Ion Field (불평등 전계중에 금속구 및 금속침의 부유 물체가 존재하는 경우의 Flashover특성)

  • Seok, B.Y.;Huh, G.D.;Kim, K.S.;Cho, J.S.;Park, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.469-471
    • /
    • 1995
  • This paper describes the effect of floating metallic object on do flashover characteristics in all gap producing unipolar ion flow field. Needle-to-plane electrodes of 120mm in gap length were used as the main gap electrode and the tested metallic objects were spheres with the radius of 2,10 and 15mm or needles from 5 to 40mm long. The characteristics of flashover voltage vs. location of the floating object are different completely with the shape of the floating metal and polarity of the applied voltage.

  • PDF

Investigation of Pre-Flashover of Alumina in Vacuum (진공중에서 Al의 플래쉬오버 현상)

  • Oh, Yong;Hwang, Jong-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.237-238
    • /
    • 2008
  • It is believed that the pre-flashover phenomena would play a very important role in the procedure of the flashover in the interface between the insulators and vacuum. This paper is mainly concerned on the pre-flashover phenomena of Alumina insulators in vacuum. There are 24 different types of alumina insulators were tested with a $0.7/4{\mu}s$ pulsed voltage under a $1{\times}10^{-4}Pa$ vacuum. The observed pre-flashover phenomena were classified and the pre-flashover characteristics were concluded. It is useful to study further on the flashover mechanism in vacuum.

  • PDF

Investigation of Pre-Flashover of Alumina in Vacuum (진공중에서 Al의 플래쉬오버 현상 조사)

  • Oh, Nam-Yeol;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2303-2304
    • /
    • 2008
  • It is believed that the pre-flashover phenomena would play a very important role in the procedure of the flashover in the interface between the insulators and vacuum. This paper is mainly concerned on the pre-flashover phenomena of Alumina insulators in vacuum. There are 24 different types of alumina insulators were tested with a 0.7/4 ${\mu}s$ pulsed voltage under a $1{\times}10^{-4}Pa$ vacuum. The observed pre-flashover phenomena were classified and the pre-flashover characteristics were concluded. It is useful to study further on the flashover mechanism in vacuum.

  • PDF

The Characteristics of Surface Flashover on the Semiconductor in High Electric-Field (고전계 하에서 반도체 연면방전 특성)

  • 이세훈;이충식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.35-43
    • /
    • 2002
  • In the last decade, considerable efforts have been made to make a new class of solid state high power, high speed electronic device, namely, the Photo-Conductive Power Switch(PCPS), and to characterize the high-field performance of PCPS under high power, high voltage conditions. But the problem of surface flashover phenomena persist, preventing the realization of reliable and efficient high-speed, high voltage switching devices. It is essential to have a clear understanding on the physical processes behind the surface flashover problem to develop new technologies and device architectures so as to fabricate PCPS that are capable of high-field high-voltage. Also, it is imperative to identify new materials that could satisfy the requirements for high-field, high-power devices. Since surface flashover, surface breakdown phenomena is observed for all the devices that foiled at the applied field much lower than semiconductor bulk breakdown field, surface passivation is considered one of the important practical methods to improve the high field performance of the devices. Therefore, this paper was studied the main properties and mechanism of the semiconductor surface flashover before and after passivation under high electric-field.

Characteristics of Surface Flashover of spacer in Liquid Nitrogen (액체 질소중에서 고체 Spacer에 의한 연면 방전특성)

  • Kim, Y.S.;Back, S.M.;Lee, B.S.;Jang, H.M.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.912-914
    • /
    • 1999
  • Composite insulation system of liquid nitrogen and solid spacer is widely applied in high temperature superconducting power machine. This study has three step procedure. As follow, first step is composition of parallel deposited electrode and vertically deposited electrode along the direction of immersion in liquid nitrogen($LN_2$). Second step is investigation into surface flashover voltage of solid spacer under partially immersed in $LN_2$, and last step is comparison the result of this research with that of fully immersed in $LN_2$ and at cryogenic temperature gaseous nitrogen($GN_2$). This result presented that surface flashover voltage along solid spacer half immersed in $LN_2$ was almost the same as that of fully immersed spacer when the thickness of spacer(t) was t<10 mm. In the case of t>10 mm, however, spacer flashover voltage was equal to that obtained in $GN_2$ at cryogenic temperature.

  • PDF

Prediction of Flashover and Pollution Severity of High Voltage Transmission Line Insulators Using Wavelet Transform and Fuzzy C-Means Approach

  • Narayanan, V. Jayaprakash;Sivakumar, M.;Karpagavani, K.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1677-1685
    • /
    • 2014
  • Major problem in the high voltage power transmission line is the flashover due to polluted ceramic insulators which leads to failure of equipments, catastrophic fires and power outages. This paper deals with the development of a better diagnostic tool to predict the flashover and pollution severity of power transmission line insulators based on the wavelet transform and fuzzy c-means clustering approach. In this work, laboratory experiments were carried out on power transmission line porcelain insulators under AC voltages at different pollution conditions and corresponding leakage current patterns were measured. Discrete wavelet transform technique is employed to extract important features of leakage current signals. Variation of leakage current magnitude and distortion ratio at different pollution levels were analyzed. Fuzzy c-means algorithm is used to cluster the extracted features of the leakage current data. Test results clearly show that the flashover and pollution severity of power transmission line insulators can be effectively realized through fuzzy clustering technique and it will be useful to carry out preventive maintenance work.

Breakdown and Surface Flashover Characteristics of FRP in $LN_2$ (액체질소 중 FRP의 절연파괴 및 연면방전 특성 연구)

  • 정종만;백승명;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.119-123
    • /
    • 2002
  • In this study, we discussed the characteristics of breakdown and surface flashover of FRP in L$N_2$ for applying it to spacer of a superconducting power equipment. Fiberglass reinforced plastic(FRP) has high breakdown puncture strength and has high mechanical strength. So the research of its dielectric properties have been conducted in liquid nitrogen($LN_2$). We measured breakdown voltage of FRP and distinguished four types of surface flashover along solid insulator with arrangement of electrodes and measured the surface flashover voltages of each types of electrode arrangement. The type of a electrode set at the back of the insulator showed the worst dielectric property. The property of surface flashover depending on pressure was tested.