• Title/Summary/Keyword: Flange panel

검색결과 67건 처리시간 0.023초

패널 존의 비탄성거동과 설계강도 (Inelastic Behavior and Design Strength of Panel Zones)

  • 김동성;김기동;고만기
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.49-52
    • /
    • 2008
  • The design strength of panel zones, which was based on Krawinkler model, was investigated by comparing it with existing test and FEM results. The design strength overestimates of the strength of panel zones with thick column flange while it matches well with the strength of panel zones with thin column flange. More extensive studies are needed to develop a mathematical model which can properly define the inelastic behavior of panel zones with various column flange thicknesses and to determine a more rational design strength.

  • PDF

롤시밍을 이용한 플랜지 패널제작에 대한 연구 (Flange Panel Forming using Roll Seaming Method)

  • 박환서;유송민;이동규;이위로;노대호
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.10-15
    • /
    • 2004
  • A machining processes for flange panel has been introduced. Contrary to the conventional methods like forming and welding, roll-seaming method has been utilized for better quality and less cost. Several measurement methods including digital image processing have been used to confirm the product quality assurance.

  • PDF

레이저 용접 테일러드 블랭크 신장 플랜지의 성형 최적화 (Optimization of Stretch Flange Forming of Laser Welded Tailored Blank)

  • 인정제;안덕찬
    • 소성∙가공
    • /
    • 제10권4호
    • /
    • pp.283-293
    • /
    • 2001
  • Laser welded tailored blanks(TB) are increasingly used in automotive parts. Among these, TB side panel has forming difficulties in stretch flanging areas such as front and center pillar lower region. To avoid splits in the stretch flanging areas, Proper design of blank shape and drawbeads are essential In this study, the forming simulaton is carried out to investigate the influences of blank shape and drawbeads on stretch flange formability of different thickness TB. And an optimization procedure including the effects of both the blank design and drawbeads is presented. The optimization procedure proposed in this study is expected to be effectively used in blank and die design of TB side panel.

  • PDF

강제라멘교각 접합부의 응력평가법 (Stress Evaluation Procedure for Connection of Steel Frame Pier)

  • 황원섭;김영필
    • 한국강구조학회 논문집
    • /
    • 제10권3호통권36호
    • /
    • pp.327-338
    • /
    • 1998
  • 본 연구는 강제라멘교각 접합부의 탄성거동에 대하여 검토한 것이다. 여기에서는 접합부 시험체의 실험결과와 FEM해석모델에 대한 결과를 비교하였다. 이와 같은 해석 및 실험결과를 비교 검토한 결과, 접합부 panel zone에서의 전단응력분포는 단면적비$(A_f/A_w)$에 따라 변화한다는 것과 전단지연(shear lag)현상에 의하여 플랜지에 발생하는 부가응력 또한 기존의 제안식과 현저한 차이가 있음을 알 수 있었다. 따라서 본 연구에서는 이상의 실험 및 해석결과를 기초로하여 접합부의 설계변수의 영향을 고려한 panel zone과 플랜지의 응력평가방법을 제안하였다.

  • PDF

편칭조건이 가공용 냉연강판의 신장플랜지 성형성에 미치는 영향 (Effect of Punching Conditions on the Stretch Flange Formability of Cold rolled Steels for Deep Drawing)

  • 전영우
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 춘계학술대회논문집
    • /
    • pp.161-164
    • /
    • 1999
  • In order to investigate the effect of punching condition on the stretch flange formability of sheet for deep drawing hole expansion tests at various edge condition were done. Edge conditions were changed by altering tool clearances artifical defects grinding and deburring. For a determination of optimum edge condition of side panel of automobile punched section analysis and forming results were studied and the laboratory test results were used. In case of considered side panel tool clearance should be less than 15% and punched edge should be uniform without defects for safe forming

  • PDF

Seismic performance of beam-to- SST column connection with external diaphragm

  • Rong, Bin;Yin, Shuhao;Zhang, Ruoyu;Wang, Lei;Yang, Ziheng;Li, Hongtao;Wan, Wenyu
    • Steel and Composite Structures
    • /
    • 제37권6호
    • /
    • pp.633-647
    • /
    • 2020
  • This paper aims to study the seismic performance of external diaphragm connection between SST (square steel tube) column and H-shaped beam through experimental and analytical study involving finite element (FE) method and theoretical analysis. In the experimental study, three external diaphragm connection specimens with weak panel zone were tested under axial pressure on the top of the column and antisymmetric cyclic loads at the beam end to investigate the seismic performance of the panel zone. The hysteretic behavior, failure mode, stiffness and ductility of the specimens were discussed. Key point to be explored was the influence of the thickness of the steel tube flange on the shear capacity of the specimens. In the analytical study, three simplified FE models were developed to simulate the seismic behavior of the specimens for further analysis on the influence of steel tube flange. Finally, four existing calculation formulas for the shear capacity of the external diaphragm connection were evaluated through comparisons with the results of experiments and FE analysis, and application suggestions were put forward.

Cyclic testing of chevron braced steel frames with IPE shear panels

  • Zahrai, Seyed Mehdi
    • Steel and Composite Structures
    • /
    • 제19권5호
    • /
    • pp.1167-1184
    • /
    • 2015
  • Despite considerable life casualty and financial loss resulting from past earthquakes, many existing steel buildings are still seismically vulnerable as they have no lateral resistance or at least need some sort of retrofitting. Passive control methods with decreasing seismic demand and increasing ductility reduce rate of vulnerability of structures against earthquakes. One of the most effective and practical passive control methods is to use a shear panel system working as a ductile fuse in the structure. The shear Panel System, SPS, is located vertically between apex of two chevron braces and the flange of the floor beam. Seismic energy is highly dissipated through shear yielding of shear panel web while other elements of the structure remain almost elastic. In this paper, lateral behavior and related benefits of this system with narrow-flange link beams is experimentally investigated in chevron braced simple steel frames. For this purpose, five specimens with IPE (narrow-flange I section) shear panels were examined. All of the specimens showed high ductility and dissipated almost all input energy imposed to the structure. For example, maximum SPS shear distortion of 0.128-0.156 rad, overall ductility of 5.3-7.2, response modification factor of 7.1-11.2, and finally maximum equivalent viscous damping ratio of 35.5-40.2% in the last loading cycle corresponding to an average damping ratio of 26.7-30.6% were obtained. It was also shown that the beam, columns and braces remained elastic as expected. Considering this fact, by just changing the probably damaged shear panel pieces after earthquake, the structure can still be continuously used as another benefit of this proposed retrofitting system without the need to change the floor beam.

다구찌법을 이용한 테일러드 블랭크의 신장플랜지 성형에 미치는 설계 인자의 영향 분석 (Effects of Blank Design factors on Stretch Flange Forming of the Tailored Blank Using Taguchi Method)

  • 백승엽;권재욱;이경돈
    • 소성∙가공
    • /
    • 제9권4호
    • /
    • pp.339-347
    • /
    • 2000
  • For the successful forming of tailored blank, it is important to control the deformation of the stretch flange mode, which is strong1y dependent upon the location of weld line and blank shape. In order to investigate the effects of tailored blank design factors on the stretch flange forming, we made the model die which can simulate stretch flange mode. Taguchi method was employed to analyze the sensitivity of blank design factors for the forming of tailored blank. From the results of experiment S/N ratios were calculated and using Variance Analysis, significance of parameters and optimal condition of each factors were extracted. Based on these analyses, the weld line height and the strength ratio and the arc center height were selected as effective parameter. The analysed result was practically applied for Side outer panel stamping process.

  • PDF

일축대칭단면 HSB800 강재 플레이트거더의 비탄성 횡비틂좌굴강도의 해석적 평가 (Numerical Analysis of Inelastic Lateral Torsional Buckling Strength of HSB800 Steel Plate Girder with Monosymmetric Section)

  • 박용명;이건준;최병호;황민오
    • 한국강구조학회 논문집
    • /
    • 제25권2호
    • /
    • pp.153-164
    • /
    • 2013
  • 본 연구에서는 균일휨모멘트를 받는 일축대칭단면 HSB800 고강도강 플레이트거더의 횡비틂좌굴(LTB) 강도를 비선형해석으로 평가하였다. 압축플랜지 단면이 인장플랜지에 비해 작은 경우와 큰 경우에 대해 각각 세장, 비조밀 및 조밀 복부판을 갖는 단면들을 고려하였으며, 비지지길이는 비탄성 LTB 영역을 대상으로 하였다. Eurocode 3 및 AASHTO, AISC 기준들과의 비교를 위해 단일패널모델과 3-패널모델을 각각 고려하였으며, 모델의 타당성을 평가하기 위해 SM490 강재 거더에 대해 먼저 해석을 수행하고 각 기준과 비교하였다. 이후 동일한 방법으로 HSB800 강재거더에 대해 LTB 강도 평가 해석을 수행하였으며, 압축플랜지 단면이 인장플랜지에 비해 작고 비조밀플랜지-세장/비조밀복부판 단면들은 현재 기준의 휨강도에 도달하지 못하는 결과를 얻었다.

Racking shear resistance of steel frames with corner connected precast concrete infill panels

  • Hoenderkamp, J.C.D.;Snijder, H.H.;Hofmeyer, H.
    • Steel and Composite Structures
    • /
    • 제19권6호
    • /
    • pp.1403-1419
    • /
    • 2015
  • When precast concrete infill panels are connected to steel frames at discrete locations, interaction at the structural interface is neither complete nor absent. The contribution of precast concrete infill panels to the lateral stiffness and strength of steel frames can be significant depending on the quality, quantity and location of the discrete interface connections. This paper presents preliminary experimental and finite element results of an investigation into the composite behaviour of a square steel frame with a precast concrete infill panel subject to lateral loading. The panel is connected at the corners to the ends of the top and bottom beams. The Frame-to-Panel-Connection, FPC4 between steel beam and concrete panel consists of two parts. A T-section with five achor bars welded to the top of the flange is cast in at the panel corner at a forty five degree angle. The triangularly shaped web of the T-section is reinforced against local buckling with a stiffener plate. The second part consists of a triangular gusset plate which is welded to the beam flange. Two bolts acting in shear connect the gusset plate to the web of the T-section. This way the connection can act in tension or compression. Experimental pull-out tests on individual connections allowed their load deflection characteristics to be established. A full scale experiment was performed on a one-storey one-bay 3 by 3 m infilled frame structure which was horizontally loaded at the top. With the characteristics of the frame-to-panel connections obtained from the experiments on individual connections, finite element analyses were performed on the infilled frame structures taking geometric and material non-linear behaviour of the structural components into account. The finite element model yields reasonably accurate results. This allows the model to be used for further parametric studies.