• 제목/요약/키워드: Flame Detection

검색결과 197건 처리시간 0.024초

원자흡광법을 이용한 요중 연 배설량의 정량 (Determination of Lead in Urine by Atomic Absorption Spectrophotometry)

  • 백남원;윤복상;정규철
    • Journal of Preventive Medicine and Public Health
    • /
    • 제7권2호
    • /
    • pp.377-381
    • /
    • 1974
  • Determination of lead in urine is important in industrial hygiene and toxicology. Dithizone method has been principally used for the determination of lead in urine, which gives accurate results in skilful hands but is usually complex and time-consuming. Atomic absorption spectrophotometry is a new simple method and several procedures have been described. However, the influences of pH and the presence of chelating agents during treatment of lead poisoning are not clear. The purpose of this study was to find out the effect of pH and chelating agents on the determination of lead using Shimadzu atomic absorption/flame spectrophotometer, model AA-610. The results obtained were as follows: 1. The atomic absorption spectrophotometry(AAS) could be applied without prior acid digestion to specimens in the absence of chelating agents. The absorbance at $2,170\;{\AA}$, though more sensitive, was more noisy electronically. Therefore, we selected the wavelength of $2,833\;{\AA}$ plus scale expansion. 2. The optimal pH was in the range from 2 to 3. 3. The sensitivity was $0.075{\mu}g/ml/%$ and detection limit was about $0.2{\mu}g/ml$. 4. In the presence of EDTA, lead could not be completely determined without prior acid digestion. 5. On specimens from patients receiving penicillamine therapy, a comparison was made between the values obtained with dithizone method and AAS method with prior acid digestion. The results of comparison showed a very good agreement.

  • PDF

Novel Solid Phase Extraction Procedure for Some Trace Elements in Various Samples Prior to Their Determinations by FAAS

  • Sacmaci, Srife;Kartal, Senol;Sacmaci, Mustafa;Soykan, Cengiz
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권2호
    • /
    • pp.444-450
    • /
    • 2011
  • A novel method that utilizes poly(5-methyl-2-thiozyl methacrylamide-co-2-acrylamido-2-methyl-1-propanesulfonic acid-co-divinylbenzene) [MTMAAm/AMPS/DVB] as a solid-phase extractant was developed for simultaneous preconcentration of trace Cd(II), Co(II), Cr(III), Cu(II), Fe(III), Mn(II), Ni(II), Pb(II), and Zn(II) prior to the measurement by flame atomic absorpiton spectrometry (FAAS). Experimental conditions for effective adsorption of the metal ions were optimized using column procedures. The optimum pH value for the simultaneously separation of the metal ions on the new adsorbent was 2.5. Effects of concentration and volume of elution solution, sample flow rate, sample volume and interfering ions on the recovery of the analytes were investigated. A high preconcentration factor, 100, and low relative standard deviation values, $\leq$1.5% (n = 10), were obtained. The detection limits (${\mu}gL^{-1}$) based on the 3s criterion were 0.18 for Cd(II), 0.11 for Co(II), 0.07 for Cr(III), 0.12 for Cu(II), 0.18 for Fe(III), 0.67 for Mn(II), 0.13 for Ni(II), 0.06 for Pb(II), and 0.09 for Zn(II). The validation of the procedure was performed by the analysis of two certified reference materials. The presented method was applied to the determination of the analytes in various environmental samples with satisfactory results.

Integrated Machine Vision을 이용한 LED Die Bonder 검사시스템 (LED Die Bonder Inspection System Using Integrated Machine Visions)

  • 조용규;하석재;김종수;조명우;최원호
    • 한국산학기술학회논문지
    • /
    • 제14권6호
    • /
    • pp.2624-2630
    • /
    • 2013
  • LED 칩 패키징에서 다이 본딩은 분할된 칩을 리드 프레임에 고정시켜 칩이 이후 공정을 견딜 수 있도록 충분한 강도를 제공하는 중요한 공정이다. 다이본딩 공정 중에서, 측정 단계는 정확한 에폭시 토출 위치 지정과 충분한 강도를 가지고 접합할 수 있도록 다이가 정확한 위치에 놓여있는지 상태를 결정하는데 있어 매우 중요하다. 본 연구에서는 LED 다이 본딩을 위한 머신 비전 기반의 측정 시스템을 개발하였다. 제안된 시스템에서 에폭시 토출과 어태칭 상태 검출을 위해 각각 2개의 카메라를 사용하였다. 제안된 측정 시스템에 새로운 비전 알고리즘을 적용하였고, 실험을 통해 본 알고리즘의 효율을 검증하였다. 비전 알고리즘을 이용하여 측정된 위치 오차는 $X:-29{\mu}m$, $Y:-32{\mu}m$, 회전오차는 3도 이내 인 것을 확인할 수 있었다. 결론적으로 제안된 머신 비전 기반의 측정 시스템을 통해 개발된 다이 본딩 시스템의 향상된 성능을 확인하였다.

GC/MS를 이용한 수질환경시료 중 personal care products의 분석 (Determination of personal care products in aquatic environmental samples by GC/MS)

  • 이인정;이철구;허성남;이재관
    • 분석과학
    • /
    • 제23권5호
    • /
    • pp.477-484
    • /
    • 2010
  • 항균제 및 자외선 차단물질, 유기인계 난연제 등과 같은 personal care products는 개인이 일상생활에서 광범위하게 사용하는 비누, 화장품, 치약 등에 포함된 합성유기화합물로 하 폐수 처리시설에서 완벽하게 제거되지 않고 생활하수에 포함된 상당수의 양이 환경 중으로 배출되고 있다. 외국사례의 경우 하천, 해양, 토양, 저질, 생물상 등 다양한 환경매체에서 검출되고 있으며, 잔류성 생물농축성이 있어 지속적으로 노출시 생태계 및 인간의 건강에 심각한 영향을 끼칠 우려가 있다. 본 연구에서는 수질환경시료 중 15종의 personal care products를 액-액추출하여 GC/MS로 분석하였으며, 방법검출한계는 $0.004\sim0.273\;{\mu}g/L$의 범위를 나타내었다. 하천수에서는 TCEP, TCPP 등 2종이 검출되었으며, 하수처리장 시료에서는 triclosan, 4-MBC, EHMC, BP-3, TCEP, TPP, TBEP 등 7종이 검출되었다.

직독식 측정기 PID와 능동식 시료채취기에 의한 GC-FID 정량분석법의 VOCs 농도 비교 연구 (Comparative Analysis between Direct-reading Meter of PID and GC-FID using the Active Type Air Sampler for VOCs Measurement)

  • 여진희;최광민
    • 한국산업보건학회지
    • /
    • 제26권3호
    • /
    • pp.301-306
    • /
    • 2016
  • Objectives: Direct-reading instrument(Photoionization detectors, PID) and quantitative analysis using active type air sampling (Gas chromatography-flame ionization detector, GC-FID) were tested to evaluate their ability to detect volatile organic compounds(VOCs) in a semiconductor manufacturing plant. Methods: The organic compounds used were acetone and ethanol which are normally used as cleaning solutions in the semiconductor manufacturing. The evaluation was based on the preparation of test solutions of known acetone and ethanol concentration in a chamber($600{\times}600{\times}1150mm$). Samples were prepared that would be equivalent to 5~100 ppm for acetone and 10~ 200 ppm ethanol. GC-FID and PID were evaluated simultaneously. Quantitative analysis was performed after sampling and the direct-reading instrument was checked using real-time data logging. Results: Positive correlations between PID and GC-FID were found for acetone and ethanol at 0.04~2.4% for acetone(TLV: 500 ppm) and 0.1~8.3% for ethanol(TLV: 1000 ppm). When the sampling time was 15 min, concentration of test solution was the most similar between measurement methods. However, the longer the sampling time, the less similar the results. PID and GC-FID had similar exposure patterns. Conclusions: The results indicate that PID and GC-FID have similar exposure pattern and positive correlation for detection of acetone and ethanol. Therefore, PID can be used for exposure monitoring for VOCs in the semiconductor manufacturing industry. This study has significance in that it validates measuring occupational exposure using a portable device.

목조문화재 건축물 구조에 따른 화재감지기 종류 선정에 관한 연구 (Selection of a Fire Detector for Wood Cultural Property)

  • 노삼규;윤형욱
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.88-93
    • /
    • 2016
  • 2008년 숭례문 화재사고 이후 국내 목조문화재에 설치된 화재감지기는 목조화재의 특성이나 구조에 대한 감지기 종류 선정기준을 가지고 있지 않다. 목조문화재 건축물은 일반건축물과 구조 및 화재특성이 달라 일반규정을 적용하기 어렵다. 따라서 목조문화재 건축물에 설치되어 있는 화재감지기의 문제점을 파악하기 위하여 건축물의 형태를 4가지로 분류하였고 현장조사 및 목조건축물의 구조 및 화재특성을 살펴보았다. 문제점으로는 화재감지기 설치 장소에 따른 적응성 부족 감지기 선택과 외부화재감지 누락이 나타났다. 문제점을 해결하기 위하여 폐쇄 및 개방된 공간의 실내화재감시에는 연기감지기를 선택하고 외부화재감시를 위해서 불꽃감지기 또는 정온식 감지선형 감지기를 건물 유형에 적합한 종류를 선정하였다.

Purity Assessment of Organic Reference Materials with a Mass Balance Method: A Case Study of Endosulfan-II

  • Kim, Seung-Hyun;Lee, Joonhee;Ahn, Seonghee;Song, Young-Sin;Kim, Dong-Kyum;Kim, Byungjoo
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권2호
    • /
    • pp.531-538
    • /
    • 2013
  • A mass balance method established in this laboratory was applied to determine the purity of an endosulfan-II pure substance. Gas chromatography-flame ionization detector (GC-FID) was used to measure organic impurities. Total of 10 structurally related organic impurities were detected by GC-FID in the material. Water content was determined to be 0.187% by Karl-Fischer (K-F) coulometry with an oven-drying method. Non-volatile residual impurities was not detected by Thermal gravimetric analysis (TGA) within the detection limit of 0.04% (0.7 ${\mu}g$ in absolute amount). Residual solvents within the substance were determined to be 0.007% in the Endosulfan-II pure substance by running GC-FID after dissolving it with two solvents. The purity of the endosulfan-II was finally assigned to be ($99.17{\pm}0.14$)%. Details of the mass balance method including interpretation and evaluating uncertainties of results from each individual methods and the finally assayed purity were also described.

Flotation-Spectrophotometric Determination of Ag(I) at the 10-7 mol L-1 Level Using Iodide and Ferroin as an Ion-associate

  • Hosseini, Mohammad Saeid;Hashemi-Moghaddam, Hamid
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권10호
    • /
    • pp.1529-1532
    • /
    • 2005
  • A simple and cost effective method for separation and preconcentration of Ag(I) at the $10^{-7}\;mol\;L^{-1}$ level in the environmental and mineral samples is present. The method is based on the flotation of Ag(I)-iodide complex as an ion-associate with ferroin in pH of 4 from a large volume of an aqueous solution (500 mL) using nheptane. The floated layer was then dissolved in dimethylsulfoxide (DMSO) for the subsequent spectrophotometric determination. Beer's law was obeyed over a range of 2.0 ${\times}$ $10^{-7}$-4.0 ${\times}$ $10^{-6}$ mol $L^{-1}$ with the apparent molar absorptivity of 2.67 ${\times}$ $10^5$ L $mol^{-1}\;cm^{-1}$. The detection limit (n = 5) was 4 ${\times}$ $10^{-8}$ mol $L^{-1}$, and RSD (n = 5) obtained for 2.0 ${\times}$ $10^{-6}$ mol $L^{-1}$ of Ag(I) was 2.2%. The interference effects of a number of elements was studied and found that only $Hg^{2+}$ at low concentration, and $Pb^{2+}$, $Cd^{2+}$, $Cu^{2+}$, and $Fe^{3+}$ ions at moderately high concentrations were interfered. To overcome on these interference effects, the solution was treated with EDTA at a buffering pH of 4 and passed through a column containing Amberlite IR-120 ionexchanger resin, just before the flotation process. The proposed method was applied to determine of Ag(I) in a synthetic waste water, a photographic washing sample and a geological sample and the results was compared with those obtained from the flame atomic absorption spectrometry. The results were satisfactorily comparable with together, so that the applicability of the proposed method was confirmed in encountering with the real samples.

냉시동 조건에서 디젤 연소 특성 및 연소 개선에 대한 연구 (Improment of Diesel Combustion using multiple injection under Cold Start Condition)

  • 이행수;이진우
    • 한국산학기술학회논문지
    • /
    • 제18권4호
    • /
    • pp.711-717
    • /
    • 2017
  • 디젤엔진은 저온 상태의 냉시동 조건에서 디젤 미립화 특성 악화로 인한 시동성 및 유해배출가스 생성의 문제를 안고 있다. 본 연구에서는 냉시동 시의 연소개선을 위한 방안으로 다단분사 전략 적용 시의 연소 특성을 파악하고자 하였다. 본 연구에서는 냉시동성 개선을 위해 방안으로 다단분사 적용 시의 연소 특성을 파악하고자 하였다. 정적 연소 챔버 내에 설치한 압력센서를 이용하여 취득한 연소압 및 열방출율, 직접 화염 가시화기법을 적용한 화염강도를 이용하여 연소현상을 분석하고자 하였다. 시험 결과 단일 분사 대비하여 다단 분사 적용 시, 주분사에 의한 최대 연소압력 및 열방출 상승률이 증가하며, 주분사에 의한 화염 감지 기간이 단축됨을 확인하였다. 파일럿 분사량 변경을 통해 분사량 증대 시 파일럿 연소에 의한 열방출 향상에 기인한 주분사에 의한 연소가 개선됨을 확인하였다. 또한 분사압력 증대 시 연료 미립화 개선으로 인한 연소개선을 화염 강도 증대를 통해 확인할 수 있었다. 다만 분사량 및 분사압 증대는 벽면적심현상으로 인한 HC, CO의 배출 수준 악화를 초래할 수 있으므로, 실제 엔진 개발 시 이에 대한 정밀한 선정이 필요할 것으로 판단된다.

IoT 기반 건물 내부 지도 및 화재 안내 시스템에 관한 연구 (Study on IoT-based Map Inside the Building and Fire Perception System)

  • 문성룡;조준호
    • 디지털융복합연구
    • /
    • 제17권1호
    • /
    • pp.85-90
    • /
    • 2019
  • 본 논문은 마이크로프로세서와 랩뷰 프로그램을 이용한 IoT 기반의 건물 내부 지도 및 화재 안내 시스템에 관현 연구 이다. 지금까지의 건물 내부의 비상구를 안내하는 장치는 화재 발생시 화재장소와 상관없이 항상 일정한 방향만을 나타내어 화재로부터 건물 밖까지 최적의 비상구를 나타내어 주지 않고 있다. 논문에서 구현된 스마트 제어 시스템은 마이크로프로세서와 불꽃 감지센서, 일산화탄소센서 및 온도센서를 이용하여 화재 발생 장소를 파악하였고, Zigbee 통신을 통하여 최적의 이동경로를 안내하도록 구성되어 있다. 그리고 제안된 시스템은 QR코드를 활용하여 스마트폰과 연동되게 하였다. 코디네이터 제어는 LABVIEW 소프트웨어를 통하여 설치된 스마트제어 시스템의 센서 값이 확인되도록 검증하였다. 본 논문에서 연구된 IoT 기반 제어시스템은 Arduino mega 보드와 LABVIEW 소프트웨어로 구현하였고, 디스플레이 장치와 코디네이션으로 동작 상태를 확인 할 수 있었다.