• Title/Summary/Keyword: Fixing material

Search Result 109, Processing Time 0.035 seconds

Effects of a Blindfold in Improving Concentration (착용형 시야 가리개가 집중력 향상에 미치는 영향)

  • Chung, Soon-Cheol;Choi, Mi-Hyun;Kim, Hyung-Sik
    • Science of Emotion and Sensibility
    • /
    • v.24 no.1
    • /
    • pp.37-44
    • /
    • 2021
  • A study was conducted on the effects of improving concentration by obscuring the peripheral vision using a blindfold that only covers the left and right sides of the field of view. The blindfold was trapezoidal in shape (5 × 4.8 cm in length and width) and was fixed to the left and right sides of the glasses with fixing clips. The material was a black-colored polypropylene (PP) and weighed 2.3 g including the clip. Qualitative and quantitative evaluations were performed on 50 healthy college students during the 15 days of using a blindfold. The qualitative analysis was performed utilizing a questionnaire regarding the improvement of concentration and the structure of the blindfold. EEG was measured while watching a learning video that required attention for quantitative analysis, and signal power and ERD/S analyses were performed for the mid β band (15-20 Hz) at the F4 position, which was the frontal lobe. The results showed that 40 of the 50 people reported improved concentration when they wore a vision shield, and 80% of the total subjects found it to be effective. From the quantitative evaluation, the ERS peak (p = 0.023) and the ERD + ERS peak value showed a significant difference (p = 0.017). In conclusion, concentration still improved even if only the left and right visual fields were used. Thus, it is expected that blindfolding could be used in various environments that require concentration.

An Analysis of the Effect of PBD Discharge Capacity to Leave Period (방치기간에 따른 PBD의 통수능 효과 분석)

  • Lee, Keeyong;Park, Minchul;Jeong, Sangguk;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.10
    • /
    • pp.39-49
    • /
    • 2011
  • Recently PBD method, one of acceleration of consolidation methods is used in the soft ground to shorten consolidation time for fast settlement during construction. It is economical and easy to work. Discharge capacity of PBD is sensitive in proportion to thickness of soft ground layer, and drainage of PBD declines due to disturbance effect in surrounding ground by mandrel used for vertical drainage setting and setting machines and type. Also, deviation of discharge capacity is large according to ground condition, construction condition and soil properties. In addition, when embankment loading is not conducted instantly after PBD setting due to rain or lack of embankment material supply, it causes leaving period problems. But cause and analysis of those problems for discharge capacity is lack. So, in this test, ground improvement and discharge capacity is investigated by implementing composite discharge capacity test for analysis of an effect factor of PBD discharge capacity with leaving period. After fixing the vertical drain on a cylindrical cylinder, put churned sample into the cylinder. Then leave 0day, 30day, 60day and 90day. And then, load following the loading step of 30, 70 and 120kPa using a pressure device. As a result, the longer leaving period, discharge capacity is reduced. It is caused by a decrease of discharge area caused by creep transformation moisture absorption of PBD filter after long leaving period.

The Conservation Treatment for the Mattress from National Folklore Cultural Heritage, the Red-lacquered Furniture with Inlaid Mother-of-pearl Design Used by Empress Sunjeonghyo and Comparative Study of Manufacturing Techniques (국가민속문화재 전 순정효황후 주칠 나전가구(傳 純貞孝皇后 朱漆 螺鈿家具) 매트리스의 보존처리 및 제작 기법 비교)

  • Park, Hyungho;Kim, Jongsu;Kim, Suchul;Keum, Jongsuk;Jang, Jongmin;Kim, Suha;Park, Changyuel
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.1
    • /
    • pp.220-237
    • /
    • 2021
  • This study carried out the conservation treatment for the mattress put on the bed, which is one of 4 items in National Folklore Cultural Heritage, the Red-lacquered Furniture with the inlaid mother-of-pearl design used by Empress Sunjeonghyo (presumed), after identifying the characteristics of the manufacturing techniques and the used materials. And the study intends to compare it with the mattress placed in the Daejojeong in the Changdeokgung Palace in order to identify the characteristics of mattresses domestically used during the 1920s and 1930s. From the analysis of the mattress presumably used by Empress Sunjeonghyo, it was identified that the mattress frame was made of pinaceous hemlock spruce while the webbing and twine in the structural parts were made of jute. The findings are as follows: the burlap had a filling material that was made of jute; the straw mat was made from Oryza; and, the rest of the filling material was cotton. Rayon was used for the top cover while cotton was used for the bottom. As a result of research on the materials and the inner structure, it was found that mattress was manufactured in the form of the upholstery style mainly found in chairs and day-beds in Western furniture. Based on analysis results, materials identical to the original were adopted during the conservation treatment. Next, the process of dismantling, cleaning, repair, reinforcement and assembling was conducted. During the dismantling process, the top cover was newly discovered and some letters (Yokohama, Kobe, and Joseon) were found in the burlap filling, but there was no trace which can clarify its maker or production place. dry cleaning was carried out on the structural parts, filling materials, and the cover, and then the repair and reinforcement were done, preserving the existing materials in the upholstery structure and using the same materials for conservation. The webbing in the structural parts was reinforced using materials identical to the original, and the twine was used for arranging and fixing the springs into wooden frames. For the damaged cotton cloth and burlap, reinforcement materials identical to the original were put over it and sown. For the damaged area of the top cover, reinforcement cloth was cut and then added inside and the damaged area was sown. Assembling was carried out in the reverse order of the dismantling. After the burlap identical to the original material was inserted into the areas in contact with the springs and then fastened, a filling pad, reinforcement cloth, a straw mat, cotton cloth, cotton felt, wide cotton cloth for protecting the cover, and the cover were layered and fastened with tacks. The two mattresses used by Empress Sunjeonghyo differed only by the period of production and followed the same Western upholstery style consisting of the frames, filling materials, and covers. During the conservation treatment process, a velvet cover was newly discovered and the traces of repair in the past were found. Furthermore, identifying straw mats, straw bags, and straws for filling material, this study confirmed changes in the materials used according to the production environment. In the future, it is expected to see changes in the conservation materials during the conservation treatment and manufacturing techniques used for chairs and sofas in the upholstery style belonging to the modern cultural artifacts.

Biaxial Strain Analysis of Various Fixation Models in Porcine Aortic and Pulmonary Valves (돼지 대동맥 판막과 폐동맥 판막의 고정 방법에 따른 양방향 압력-신장도의 비교분석)

  • Cho, Sung-Kyu;Kim, Yong-Jin;Kim, Soo-Hwan;Choi, Seung-Hwa
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.566-575
    • /
    • 2009
  • Background: The function of a bioprosthetic heart valve is determined largely by the material properties of the valve cusps. The uniaxial tensile test has been studied extensively. This type of testing, however, does not replicate the natural biaxial loading condition. The objective of the present study was to investigate the regional variability of the biaxial strain versus pressure relationship based on the types of fixation liquid models. Material and Method: Porcine aortic valves and pulmonary valves were assigned to three groups: the untreated fresh group, the fixed with glutaraldehyde (GA) group, and the glutaraldehyde with solvent (e.g., ethanol) group. For each group we measured the radial and circumferential stretch characteristics of the valve as a function of pressure change. Result: Radial direction elasticity of porcine aortic and pulmonary valves were better than circumferential direction elasticity in fresh, GA fixed and GA+solvent fixed groups (p=0.00). Radial and circumferential direction elasticity of pulmonary valves were better than aortic valves in GA fixed, and GA+solvent fixed groups (p=0.00). Radial and circumferential direction elasticity of aortic valves were decreased after GA and GA+solvent fixation(p=0.00), except for circumferential elasticity of GA+solvent fixed valves (p=0.785). The radial (p=0.137) and circumferential (p=0.785) direction of elasticity of aortic valves were not significantly different between GA fixed. and GA+solvent fixed groups. Radial (p=0.910) and circumferential (p=0.718) direction of elasticity of pulmonary valve also showed no significant difference between GA fixed and GA+solvent fixed groups. Conclusion: When fixing porcine valves with GA, adding a solvent does not cause a loss of mechanical properties, but, does not improve elasticity either. Radial direction elasticity of porcine aortic and pulmonary valves was better than circumferential direction elasticity.

Comparison of the Uniaxial Tensile Strength, Elasticity and Thermal Stability between Glutaraldehyde and Glutaraldehyde with Solvent Fixation in Xenograft Cardiovascular Tissue (이종심혈관 조직에 대한 글루타알데하이드 및 용매를 첨가한 고정방법에 따른 장력, 탄력도 및 열성 안정성 비교연구)

  • Cho, Sung-Kyu;Kim, Yong-Jin;Kim, Soo-Hwan;Park, Ji-Eun;Kim, Wong-Han
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.165-174
    • /
    • 2009
  • Background: With the advances of cardiac surgery, the demand for an artificial prosthesis has increased, and this has led to the development and utilization of diverse alternative materials. We conducted this research to improve an artificial prosthesis by examining the changes of the physical qualities, the pressure related tensile strength, the change in elasticity and the thermostability of a xenograft valve (porcine) and pericardium (bovine, porcine) based on the type of fixation liquid we used. Material and Method: The xenograft valves and pericardium were assigned into three groups: the untreated group, the fixed with glutaraldehyde (GA) group and the glutaraldehyde with GA+solvent such as ethanol etc. group. The surgeons carried out each group's physical activities. Each group's uniaxial tension and elasticity was measured and compared. Thermostability testing was conducted and compared between the bovine and porcine pericardium fixed with GA group and the GA+solvent group. Result: On the physical activity test in the surgeon's hand, no significant difference between the groups was sensed on palpation. For suture and tension, the GA+solvent group was slightly firmer than the low GA concentration group. In general, the circumferential uniaxial tension and elasticity of the porcine aortic and pulmonary valves were better in the fixed groups than that in the untreated group. There was no significant difference between the GA and GA+solvent groups (p>0.05). Bovine and porcine pericardium also showed no significant difference between the GA group and the GA+solvent group (p>0.05). When comparing between the groups for each experiment, the elasticity tended to be stronger in most of the higher GA concentration group (porcine pulmonary valve, porcine pericardium). On the thermostability testing of the bovine and porcine pericardium, the GA group and the G+solvent group both had a sudden shrinking point at $80^{\circ}C$ that showed no difference (bovine pericardium: p=0.057, porcine pericardium: p=0.227). Conclusion: When fixing xenograft prosthetic devices with GA, adding a solvent did not cause a loss in pressure-tension, tension-elasticity and thermostability. In addition, more functional solvents or cleansers should be developed for developing better xenografts.

The Study of Usefulness of Metal Artifact Reduction Algorithm and Artifacts Caused by Metallic Hip Prosthesis on PET/CT (PET/CT에서의 고관절 삽입물에 의한 인공물과 Metal Artifact Reduction Algorithm의 유용성에 대한 고찰)

  • Park, Min Soo;Ham, Jun Cheol;Cho, Yong In;Kang, Chun Goo;Park, Hoon-Hee;Lim, Han Sang;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.35-43
    • /
    • 2012
  • Purpose : PET/CT performed CT-based attenuation correction generates the beam hardening artifact by metallic implant. The attenuation correction causes over or underestimate of the area adjacent to metallic hip prosthetic material and change of $^{18}F$-FDG uptake. Also, the image quality and the diagnosability on genitourinary disease are reduced. Therefore, this study will evaluate the usefulness of MAR (Metal Artifact Reduction) algorithm method to improve the image quality on PET/CT. Materials and Methods : PET/CT was performed by fixing hip prosthesis in SPECT/PET phantom. In PET images with and Without MAR algorithm, the Bright streak, Dark streak, Metal region and Background area that appeared on CT were confirmed, and the change of each SUV (standardized uptake value) was analyzed. Also, in 15 patients who underwent total hip arthroplasty, each MAR algorithm and Without MAR algorithm and non attenuation correction was evaluated. Results : In PET image Without MAR algorithm, SUV of Bright streak region was $0.98{\pm}0.48$ g/ml; Dark streak region was $0.88{\pm}0.02$ g/ml; Metal region was $0.24{\pm}0.16$ g/ml, Background area was $0.91{\pm}0.18$ g/ml. In SUV of PET image with MAR algorithm, Bright streak region was $0.88{\pm}0.49$ g/ml, Dark streak region was $0.63{\pm}0.21$ g/ml, Metal region was $0.06{\pm}0.07$ g/ml, Background was $0.90{\pm}0.02$ g/ml. SUV generally decreased when applying MAR algorithm. In PET image Without MAR algorithm, SUVs of Bright region were higher than those measured in the Background, and it was false positive uptake. But, in PET image with MAR algorithm, SUVs of Bright region were similar to the Background, and false positive uptake disappeared. Conclusion : MAR algorithm could reduce an increase of $^{18}F$-FDG uptake due to attenuation correction in the hip surrounding tissue. However, decrease of SUV in Dark streak region should be considered in the future. Therefore, this study propose that the diagnostic accuracy can be improved in genitourinary diseases adjacent to metallic hip prosthesis, if provided PET images with and Without MAR algorithm, and non attenuation correction images at the same time.

  • PDF

Anti-calcification Effects in Decellularized and Variously Fixed Bovine Pericardium (소심낭 절편의 무세포화와 알코올 전처치를 포함한 여러 고정 처리법 시행 후 석회화 경감 효과 관찰 연구)

  • Hwang, Seong-Wook;Kim, Yong-Jin;Kim, Soo-Hwan;Choi, Seung-Hwa
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.235-245
    • /
    • 2010
  • Background: Our goal was to evaluate anti-calcification effects of decellularization and diverse fixing methods including preincubation of the bovine pericardium with ethanol. We also assessed changes in mechanical properties. Material and Method: Harvested bovine pericardium was decellularized with 0.25% sodim dodecysulfate and then treated with 5 methods of fixation: (1) 0.5% glutaraldehyde (GA) for 14 days, (2) 0.5% GA for 5 days, 2% GA for 2 days and 0.25% GA for 7 days, (3) 0.5% GA for 5 days, 2% GA for 2 days, 0.25% GA for 7 days, and then 70% ethanol for 2 days, (4) 0.5% GA for 5 days, a mixture of 2% GA and 70% ethanol for 2 days, and 0.25% GA for 7 days, (5) 0.5% GA for 5 days, a mixture of 2% GA, 65% ethanol, and 5% octanediol for 2 days and then 0.25% GA for 7 days. All treated bovine pericardia were tested for histological variables, lipid content, and mechanical properties including tensile strength and thermal stability. A total 10 kinds of differently treated bovine pericardia were implanted into rat subdermis and harvested 8 weeks later. Harvested pericardia were evaluated for calcium content. Result: No protein denaturation was observed microscopically after decellularization. There was a 32% mean decrease in tensile strength index after decellularization in the bovine pericardium group fixed. Octanediol preincubation attenuated the decrease in tensile strength and maintained thermal stability. TG and cholesterol were not affected by decellularization but were decreased by organic solvent. Calcium content was decreased after decellularization, and organic solvent preincubation decreased calcification in the non-decellularized bovine pericardium group. Conclusion: Decellularization and organic solvent preincubation have anti-calcification effects but decellularization may cause mechanical instability. A method of decellularization and fixation that does not cause damage to matrices will be needed for evaluation of the next step in using tissue-engineering for replacement of cardiac valves.

Bachelard's Theory of Imagination and the Philosophical Bases of Creativity (바슐라르의 상상력 이론과 창의력의 철학적 기초)

  • Yoo, Kyoung-Hoon
    • Journal of Gifted/Talented Education
    • /
    • v.19 no.3
    • /
    • pp.603-646
    • /
    • 2009
  • This paper explores in depth Gaston Bachelard's theory of imagination so as to establish the philosophical bases of creativity. While he had begun his studies on imagination to eliminate unreliable subjectivity hampering objectivity of philosophy of science, he was fascinated to become a philosopher of imagination by its unlimited power. Since his theory of imagination marked a prominent spot in the history of Western idea, this paper will seek its significant implications that will also shed light on the philosophical grounds of creativity. The best way to approach his theory is to differentiate whether imagination is the power of forming images or that of transforming them. If not misguided by surface simplicity of the aforementioned differentiation, it will be revealed that it has accrued strata in the history of Western idea. The power of forming images is related to theory of mimesis or of representation, and to ocularcentric and logo-centric structures. Bachelard strongly opposes to the theory of imagination as power of forming images, since, if it is so, its expansion and development are not possible. He thereby constructs the theory of imagination as power of transforming images. The force of movement lies at the core of his theory. Imagination as an ability to intuit movement is directly related to the problem of change in the history of Western idea. If an entity is incessantly changes itself, it becomes a crucial role of imagination to capture the force perse in the perpetual movement without distortedly and abruptly fixing it at a still point of time and space. Bachelard criticizes such a method that makes movement a controllable entity consisting of partitioned moments of space; instead, he constructs theory of imagination that reveals the true power of indispensable movement. Furthermore, it will be revealed that Bachelard's theory has more affinities with Kantian imagination and reflective judgement of aesthetics than the past researches on Bachelard showed. This paper, by means of the above investigation, will transcend the superficiality of defining what are Bachelard's formal, material, and dynamic imaginations; simultaneously, it will bear philosophical conditions of possibility that makes us experience imagination fully. These conditions also become the philosophical foundations of creativity. It will draw to a provisional close its imaginative journey of everlasting movement by making ontological and ethical dimensions of imagination and creativity.

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF