• 제목/요약/키워드: Fixed-width

검색결과 456건 처리시간 0.033초

A New PWM-Controlled Quasi-Resonant Converter for a High Efficiency PDP Sustaining Power Module

  • Lee, Woo-Jin;Choi, Seong-Wook;Kim, Chong-Eun;Moon, Gun-Woo
    • Journal of Power Electronics
    • /
    • 제7권1호
    • /
    • pp.28-37
    • /
    • 2007
  • A new PWM-controlled quasi-resonant converter for a high efficiency PDP sustaining power module is proposed in this paper. The load regulation of the proposed converter can be achieved by controlling the ripple of the resonant voltage across the resonant capacitor with a bi-directional auxiliary circuit, while the main switches are operating at a fixed duty ratio and fixed switching frequency. Hence, the waveforms of the currents can be expected to be optimized from the view-point of conduction loss. Furthermore, the proposed converter has good ZVS capability, simple control circuits, no high voltage ringing problem of rectifier diodes, no DC offset of the magnetizing current and low voltage stresses of power switches. In this paper, operational principles, features of the proposed converter, and analysis and design considerations are presented. Experimental results demonstrate that the output voltage can be controlled well by the auxiliary circuit using the PWM method.

저전압 고성능 DSP를 이용한 AC 서보모터 제어 (AC Servo Motor Control Using Low Voltage High Performance DSP)

  • 최치영;홍선기
    • 반도체디스플레이기술학회지
    • /
    • 제3권1호
    • /
    • pp.21-26
    • /
    • 2004
  • Recently with the development of power switching device and DSP which has peripheral devices to control AC servo system, the servo technology has met a new development opportunity. Those things make it possible to reduce the time of developing a AC servo system. Fixed point DSP such as TMS320F240x, and TMS320F28x series have a disadvantage in calculating floating number where TMS320C32 or TMS320C31 are floating point DSP. However they usually become a complex hardware system to implement the AC servo system and it increases the cost. In this study, a DSP based AC servo system with a 3-phase PMSM is proposed. The newly produced DSP TMX320F28l2-version C which has the performance of fast speed, 150MIPS, and a rich peripheral interface such as a 12bit high speed AD converter, QEP(Quadrature Encoder Pulse) circuit, PDPINT(Power Drive Protect Interrupt), SVPWM module and dead time module are used. This paper presents a method to overcome fixed point calculating using scaling all parameters. Also space vector pulse width modulation (SVPWM) using off-set voltage and a digital PI control are implemented to the servo system.

  • PDF

미세 딤플 가공 표면의 수력학적 윤활특성에 대한 수치해석 (NUMERICAL INVESTIGATION ON HYDRODYNAMIC LUBRICATION CHARACTERISTICS OF MICRO DIMPLE TEXTURED SURFACES)

  • 홍사훈;이재응;조민행;이성혁
    • 한국전산유체공학회지
    • /
    • 제14권4호
    • /
    • pp.56-61
    • /
    • 2009
  • This study deals with the numerical investigation on two-dimensional lubrication characteristics of micro-dimple shapes fabricated on solid surfaces by using the commercial CFD code (Fluent V.6.3) to examine the influence of micro dimple depth and width on the reduction in friction under the sliding plate condition. In addition, single and multiple dimple arrays are simulated, all for a fixed area fraction of dimple on the surface. As a result, it is found that the existence of micro-dimpled surface makes it possible to substantially reduce the friction forces exerted on the surfaces, and such an optimum dimple depth would be present because the dimple depth larger than the optimum value did no longer affect the reduction in shear stresses, indicating that the reduction of friction is likely to be associated with inner flows of lubricant inside dimples. Moreover, it is observed that at the fixed area fraction, the friction reduction increases with the increase of dimple diameter.

유전자 알고리즘을 이용한 고정 셀에서 글자 폰트(font) 최적화 (Word Processor font optimization in Fixed-function cell Using a Genetic Algorithm)

  • 김상원;김승희;김우제
    • 한국컴퓨터정보학회논문지
    • /
    • 제18권10호
    • /
    • pp.163-172
    • /
    • 2013
  • 본 연구는 유전자알고리즘을 사용하여 표의 크기에 맞게 가장 최적화된 글자로 표현할 수 있는 방법을 실험하였다. 그 결과 셀의 넓이와 높이, 입력받을 글자의 개수를 계산하여 글자 크기, 줄 간격, 자간 간격의 최적의 값을 찾아 길이가 서로 다른 글자를 최적화된 상태로 표현할 수 있도록 폰트를 제공할 수 있었다. 본 연구는 유전자 알고리즘을 통하여 현재 사용하고 있는 다양한 워드프로세스에서 발생되고 있는 셀 고정 상태에서의 글자 최적화 문제에 대한 해결 방법을 제시하였다는데 그 의의가 있다.

PWM-Based Sliding Mode Controller for Three-Level Full-Bridge DC-DC Converter that Eliminates Static Output Voltage Error

  • Liu, Jilong;Xiao, Fei;Ma, Weiming;Fan, Xuexin;Chen, Wei
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.378-388
    • /
    • 2015
  • This paper proposes a pulse width modulation (PWM)-based sliding mode controller (SMC) for a full-bridge DC-DC converter that can eliminate static output voltage error. Hysteretic SMC in DC-DC converter does not have a fixed switching frequency, and applying hysteretic SMC to full-bridge converters is difficult. Fixed-frequency SMC, which is also called PWM-based SMC, based on equivalent control overcomes these shortcomings. However, the controller order reduction in equivalent control in PWM-based SMC causes static output voltage error. To resolve this issue, an integral item is added to the PWM-based SMC. Sliding mode coefficients are designed by applying a standard second-order system to the sliding mode surface. The effect of adding an integral item on the controller is analyzed, and an integral coefficient design method is proposed. Experiment results on a three-level full-bridge DC-DC converter verify the control scheme and design method proposed in this paper.

균열모델을 사용한 철근콘크리트 구조물의 비선형거동 해석에 관한 연구 (A Study on Nonlinear Behavior of RC Structure using Different Crack Models)

  • 김성칠;안영기;박성용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권4호
    • /
    • pp.139-146
    • /
    • 2002
  • A analysis of crack behavior in RC member was performed by nonlinear finite element method. Two crack models were used in F.E.M.(finite element method): one was FCM (the fixed crack model) and the other was RCM (the rotated crack model). Based on parametric study, the ratio of shear steel, strength of concrete, and a/d(shear span/effective depth) were compared with test results of references. According to the test results, when the member behavior was affected by the shear or diagonal tension, RCM was reasonable. However, when the behavior was affected by the flexibility, FCM was more appropriate. In addition, each crack model behavior for the change of shear steel ratio, the increase of strain energy was constant in FCM, but it was different in RCM because of diagonal crack distribution and crack width. Since the strength of concrete is affected not only by shear but also by flexural strength, each crack model behavior yields similar results.

An approximate formula to calculate the fundamental period of a fixed-free mass-spring system with varying mass and stiffness

  • Kim, Juwhan;CoIIins, Kevin R.;Lim, Yun Mook
    • Structural Engineering and Mechanics
    • /
    • 제25권6호
    • /
    • pp.717-732
    • /
    • 2007
  • A formula to approximate the fundamental period of a fixed-free mass-spring system with varying mass and varying stiffness is formulated. The formula is derived mainly by taking the dominant parts from the general form of the characteristic polynomial, and adjusting the initial approximation by a coefficient derived from the exact solution of a uniform case. The formula is tested for a large number of randomly generated structures, and the results show that the approximated fundamental periods are within the error range of 4% with 90% of confidence. Also, the error is shown to be normally distributed with zero mean, and the width of the distribution (as measured by the standard deviation) tends to decrease as the total number of discretized elements in the system increases. Other possible extensions of the formula are discussed, including an extension to a continuous cantilever structure with distributed mass and stiffness. The suggested formula provides an efficient way to estimate the fundamental period of building structures and other systems that can be modeled as mass-spring systems.

Nanofluid flow and heat transfer from heated square cylinder in the presence of upstream rectangular cylinder under Couette-Poiseuille flow

  • Sharma, Swati;Maiti, Dilip K.;Alam, Md. Mahbub;Sharma, Bhupendra K.
    • Wind and Structures
    • /
    • 제29권1호
    • /
    • pp.65-75
    • /
    • 2019
  • A heated square cylinder (with height $A^*$) is kept parallel to the cold wall at a fixed gap height $0.5A^*$ from the wall. Another adiabatic rectangular cylinder (of same height $A^*$ and width $0.5A^*$) is placed upstream in an inline tandem arrangement. The spacing between the two cylinders is fixed at $3.0A^*$. The inlet flow is taken as Couette-Poiseuille flow based non-linear velocity profile. The conventional fluid (also known as base fluid) is chosen as water (W) whereas the nanoparticle material is selected as $Al_2O_3$. Numerical simulations are performed by using SIMPLE algorithm based Finite Volume approach with staggered grid arrangement. The dependencies of hydrodynamic and heat transfer characteristics of the cylinder on non-dimensional parameters governing the nanofluids and the fluid flow are explored here. A critical discussion is made on the mechanism of improvement/reduction (due to the presence of the upstream cylinder) of heat transfer and drag coefficient, in comparison to those of an isolated cylinder. It is observed that the heat transfer increases with the increase in the non-linearity in the incident velocity profile at the inlet. For the present range studied, particle concentration has a negligible effect on heat transfer.

유출수 및 유실토량 측정장치에 관한 수리시험 (Hydraulic Experiments on the Measuring Equipments of Ronoff and Soil Loss)

  • 유한열
    • 한국농공학회지
    • /
    • 제10권1호
    • /
    • pp.1377-1387
    • /
    • 1968
  • In order to measure runoff and soil losses produced in a small test plot during rainfall, it is usually insufficient to use a tank only, necessitating the combined use of a main tank and a subsidiary tank. Accordingly. exact measurement largely depends on how to connect those two measuring tanks. The main purpose of this thesis is to improve the connecting parts of two measuring tanks so as to assure exact measurement of runoff and soil losses. In this experiment, two types of main tank, i. e. A-type and B-type, were used. A-type is a square tank having a flume at its end. At the flume, ten apertures are provided by using metal columns so as to be able to catch one tenth of total muddy flow discharging at the end of the flume, One tenth of total flow is led to the subsidiary tank through a slot sampler fixed to an aperture. B-type differes in that its flume does not have apertures and slot sampler is fixed directly to the end of the flume, other features being the same as those of A-type. Discharge volumes were measured by using weighing tanks and compared. The effect of baffle screen provided in the flume was also observed in connection with exact measurements. In order to keep main tank and its flume in a horizontal position, bolts and nuts mechanism was used. Vertical and horizontal screens were provided in the main to prevent coarse sands coming into the flume. The conclusion derived through this experiment is as follows: (1) The discharge through slot sampler at each aperture is almost the same for A-type. However, it is slightly more than one tenth of total discharge volume. (2) In case that baffle screen is provided in the flume of A-type tank, the discharge volume of slot sampler is less than that of the same type without screen. (3) For B-type tank, slot sampler discharge increases as slot sampler nears toward the center of flume. (4) When baffle screen is provided in the flume of B-type, slot sampler discharge is less than that of the same type without screen, and this phenomenon is more apparent as compared with A-type. (5) In case that the slot width of slot sampler for B-type is one inch, slot sampler discharge exceeds one tenth of total discharge volume. (6) When the slot width for B-type is 15/16 inch and slot sampler is fixed 3/8 inch apart from either flume wall, slot sampler discharge is approximately equal to one tenth of total discharge volume.

  • PDF

고정식 초점형 SPECT에 있어, 선예도와 감도의 공간 균일성에 대한 평가 (Evaluation of Spatial Uniformity about Resolution and Sensitivity of a 'fixed focusing type SPECT')

  • 김재일;임정진;조성욱;노경운
    • 핵의학기술
    • /
    • 제23권1호
    • /
    • pp.54-58
    • /
    • 2019
  • Capillary tube 10개를 $^{99m}Tc$로 채워서 고정식-초점형 SPECT와 회전식-평형 SPECT 장비를 이용하여 선예도와 감도를 평가하였다. 그리고 이 데이터를 이용하여 검출-조사야 내에서의 평균값과 표준편차를 이용하여 균일도를 나타내는 변동계수를 평가하였다. 고정식-초점형 SPECT의 선예도 균일도와 감도 균일도는 회전식-평형 SPECT 에 비해 각각 68%, 110% 높게 평가되었다.