• Title/Summary/Keyword: Fixed surface

Search Result 1,454, Processing Time 0.037 seconds

The Effect of Fixed Oxide Charge on Breakdown Voltage of p+/n Junction in the Power Semiconductor Devices (전력용 반도체 소자의 설계 제작에 있어서 Fixed oxide charge가 p+/n 접합의 항복전압에 미치는 영향)

  • Yi, C.W.;Sung, M.Y.;Choi, Y.I.;Kim, C.K.;Suh, K.D.
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.155-158
    • /
    • 1988
  • The fabrication of devices using plans technology could lend to n serious degradation in the breakdown voltage as a result of high electric field at the edges. An elegant approach to reducing the electric field at the edge is by using field limiting ring. The presence of surface charge has n strong influrence on the depletion layer spreading at the surface region because this charge complements the charge due to the ionized acceptors inside the depletion layer. Surface charge of either polarity can lower the breakdown voltage because it affects the distribution of electric field st the edges. In this paper we discuss the influrences of fixed oxide charge on the breakdown voltage of the p+/n junction with field limiting ring(or without field limiting ring).

  • PDF

Investigation of surface-piercing fixed structures with different shapes for Bragg reflection of water waves

  • Ding, Wei-Wei;Zou, Zao-Jian;Wu, Jing-Ping;Huang, Bai-Gang
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.2
    • /
    • pp.819-827
    • /
    • 2019
  • Bragg reflection of water waves by three kinds of surface-piercing fixed structures with rectangular, cosinoidal and triangular shapes is studied. Boundary element method is used to analyze the wave scattering by these structures based on the linear wave theory. Results of reflection and transmission coefficients are validated by comparing with those available in literature. These structures with proper configurations are proved to be effective in attenuating waves by using Bragg reflection, and the triangular structures are found to be the best choices among the structures with same width and same area. Systematic calculations are then carried out for the triangular structures by varying the number, the draft, the width, the gap and the combination of width and gap of the structures to analyze their influences on the characteristics of Bragg reflection. The results are of reference values for design of the structures to attenuate waves based on the Bragg reflection.

A Study on the Parameter Estimation of DURUMI-II for the Fixed Right Elevator Using Flight Test Data

  • Park Wook-Je;Kim Eung-Tai;Seong Kie-Jeong;Kim Yeong-Cheol
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.8
    • /
    • pp.1224-1231
    • /
    • 2006
  • The stability and control derivatives of DURUMI-lI UAV using the flight test are obtained. The flight test data is gathered from the normal flight condition (normal mode) and the flight condition assumed as the right elevator fixed (fault mode). Using real-time parameter estimation techniques, applied to Fourier transform regression method, simulates the aircraft motion. From the result, the fault of control surface is to be detected. In this paper, the results of the real- time parameter estimation techniques are compared with the results of the Advanced Aircraft Analysis (AAA). Using the aerodynamic derivatives, it provides the base line of normal/failure for the control surface by using the on-line parameter estimation of Fourier transform regression. In flight, this approach maybe helpful to detect and isolate the fault of primary control surface. It is explained how to perform the flight condition assumed as the right elevator fixed in the flight test. Also, it is mentioned how to switch between the normal flight condition and the assumed fault flight condition.

A study of high-efficiency rotating condensing hybrid solar LED street light module system (고효율 회전 집광형 하이브리드 태양광 LED 가로등 모듈 시스템 연구)

  • Min, Kyung-Ho;Jeon, Yong-Han
    • Design & Manufacturing
    • /
    • v.15 no.3
    • /
    • pp.50-55
    • /
    • 2021
  • Solar power generation, which is one of the methods of using solar energy, has a high possibility of practical implementation compared to other renewable energy power generation, and it has the characteristic that it can generate as much power as needed in necessary places. In addition, maintenance is easy, unmanned operation is possible, and power management can be performed more efficiently if operated in a hybrid method with existing electric energy. Therefore, in this study, numerical analysis using a computer program was performed to analyze the efficient operation and performance improvement of solar energy of the rotating condensing type solar LED street lamp. As a result, the two-axis tracking type could obtain 15.23 % more electricity per year than the fixed type, and additional auxiliary power generation was required for the fixed type by 19 % per year than the tracking type. As a result of computational fluid dynamics(CFD) simulation for PV module surface temperature prediction, the The surface temperature of the Photovoltaics(PV) module incident surface was predicted to be about 10℃ higher than that of the fixed type.

Experimental Study on the Ground Support Conditions of Pipe Ends in Single Span Pipe Greenhouse (단동파이프하우스의 지점조건 분석을 위한 실험 연구)

  • Lee, Suk-Gun;Lee, Jong-Won;Kwak, Cheul-Soon;Lee, Hyun-Woo
    • Journal of Bio-Environment Control
    • /
    • v.17 no.3
    • /
    • pp.188-196
    • /
    • 2008
  • Single span pipe greenhouses (pipe houses) are widely used in Korea because these simple structures are suitable for construction by farmers thus reducing labor cost. However, these pipe houses are very weak and frequently damaged by heavy snow and strong wind. Pipe house is constructed by pipe fabricator, which is anchored to the ground by inserting each pipe end into ground to $30\sim40cm$, so the ground support condition of pipe end is not clear for theoretical analysis on greenhouse structure. This study was carried out to find out the suitable ground support condition needed f3r structural analysis when pipe house was designed. The snow and wind loading tests on the actual size pipe house were conducted to measure the collapsing shape, displacement and strain. The experimental results were compared with the structural analysis results for 4 different ground support conditions of pipe ends(fixed at ground surface, hinged at ground surface, fixed under ground and hinged under ground). The pipe house under snow load was collapsed at the eaves as predicted, and the actual strain at the windward eave and ground support under wind load was larger than that under snow load. The displacement was the largest at the hinged support under ground, followed by the hinged at ground surface, the fixed under ground and then the fixed at ground surface independent of displacement direction and experimental loading condition. The experimental results agreed most closely with the results of theoretical analysis at the fixed condition under ground among 4 different ground support conditions. As the results, it was recommended that the pipe end support condition of single span pipe greenhouse was the fixed under ground for structural analysis.

Development of the Small Wastes Incinerator with High Combustion Efficiency (연소효율이 우수한 소형 소각로의 개발)

  • 한돈희;하대성
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.81-85
    • /
    • 2000
  • In order to reduce emission of air pollutants from spot incineration, it is required to develope the combustion chamber of small wastes incinerator having combustion efficiency. The characteristics of combustion of the incinerator with combustion chamber having tangential angels with surface of 45$^{\circ}$of air supply nozzles were studied in accordance with non-grate, fixed-grate and shaking-grate in the combustion chamber. Combustion conditions were evaluated with combustion efficiency, emission of hazardous gases, temperatures, ignition loss of ash and so on. Combustion efficiencies were shown 73.9% for non-gate, 81.1% for fixed-grate and 89.0% for shaking-grate. Emissions of CO were revealed 6.52 ppm for non-grate, 273 ppm for fixed-grate and 224 for shaking-grate. Comprehensively evaluated, combustion conditions got better in order of shaking-grate, fixed-grate and non-grate. This study suggests that small wastes incinerator should have shaking-or fixed-grate in combustion chamber to get better combustion condition even though at expensive cost of manufacturing.

  • PDF

Tungsten CMP in Fixed Abrasive Pad using Hydrophilic Polymer (친수성 고분자를 이용한 고정입자패드의 텅스텐 CMP)

  • 박범영;김호윤;김형재;김구연;정해도
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.7
    • /
    • pp.22-29
    • /
    • 2004
  • As a result of high integration of semiconductor device, the global planarization of multi-layer structures is necessary. So the chemical mechanical polishing(CMP) is widely applied to manufacturing the dielectric layer and metal line in the semiconductor device. CMP process is under influence of polisher, pad, slurry, and process itself, etc. In comparison with the general CMP which uses the slurry including abrasives, fixed abrasive pad takes advantage of planarity, resulting from decreasing pattern selectivity and defects such as dishing & erosion due to the reduction of abrasive concentration especially. This paper introduces the manufacturing technique of fixed abrasive pad using hydrophilic polymers with swelling characteristic in water and explains the self-conditioning phenomenon. And the tungsten CMP using fixed abrasive pad achieved the good conclusion in terms of the removal rate, non-uniformity, surface roughness, material selectivity, micro-scratch free contemporary with the pad life-time.

Treatment of Organic Wastewater by the Anaerobic Fixed-Film Process (혐기성 생물막법에 의한 유기성 배수의 처리)

  • 김용대;정경훈
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.2
    • /
    • pp.41-47
    • /
    • 1991
  • A study on the effects of volumetric loading rate, surface loading rate and hydraulic. retention time (HRT) for the anaerobic treatment was conducted with the anaerobic fixed-film process using synthetic wastewater at lower temperature than that of conventional anaerobic treatment. The results are as follows 1. Alkalinity and pH value decreased as the hydraulic retention time increased 2. Increase of the volumetric lodaing rate led to increasl of effluent COD concentration and decrease of COD removal efficiency. 3. The removed volumetric loading rate increased linearly according to the increase of the volumrtric loading rate. 4. Similarly, the linear increase of the removed surface loading rate was noticed with an increase of the surface loading rate.

  • PDF

Numerical Simulation of NIL Process Based on Continuum Hypothesis (연속체 가정을 통한 NIL 공정의 전산모사)

  • Kim, Seung-Mo;Lee, Woo-Il
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.532-537
    • /
    • 2007
  • Nano imprint lithography(NIL) is a cost-efficient, high-throughput processing technique to transfer nano-scale patterns onto thin polymer films. Polymers used as the resist include UV cured resins as well as thermoplastics such as polymethyl-methacrylate(PMMA). In this study, an analytic investigation was performed for the NIL process of transferring nano scale patterns onto polymeric films. Process optimization calls for a thorough understanding of resist flow during the process. We carried out 2D and 3D numerical analyses of resist flow during NIL process. The simulation incorporated continuum-hypothesis and the effects of surface tension were taken into account. For a more effective prediction of free surface, fixed grid scheme with the volume of fluid (VOF) method were used. The simulation results were verified with experimental results qualitatively. And the parametric study was performed for various process conditions.

  • PDF

Design of a Variable Structure Controller Using Nonlinear Fuzzy Sliding Surfaces (비선형 퍼지 슬라이딩면을 이용한 가변구조 제어기의 설계)

  • 이희진;손홍엽;김은태;조영환;박민용
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1997.10a
    • /
    • pp.449-452
    • /
    • 1997
  • In this paper, we suggest a variable structure controller using the time-varying nonlinear sliding surface instead of the fixed sliding surface, which has been the robustness against parameter variations and extraneous disturbance during the reaching phase. As appling TS fuzzy algorithm to the regulation of the nonlinear sliding surface, the reaching time of the system trajectory is faster than the fixed method . This proposed scheme has better performance than the conventional method in reaching time parameter variation and extraneous disturbance. To demonstrate its performance, the proposed control algorithm is applied to a rotational inverted pendulum.

  • PDF