• Title/Summary/Keyword: Fixed prosthesis

Search Result 345, Processing Time 0.028 seconds

Implant Supported Fixed Restoration for Maxillary Edentulism using CAD/CAM Guided Implant Surgery (NobelGuide$^{TM}$) and Immediate Loading (상악 완전 무치악 환자의 CAD/CAM 을 이용한 임플란트 식립(NobelGuide$^{TM}$) 및 즉시하중 후 고정성 보철수복 증례)

  • Huh, Yoon-Hyuk;Yi, Yang-Jin;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.423-439
    • /
    • 2012
  • This case report described a technique utilizing a computer-aided design (CAD)/computer-aided machining (CAM) - guided surgical implant placement and prefabricated temporary fixed prosthesis for an immediately loaded restoration. The advantages of CAD/CAM guided implant procedures are flapless, minimally invasive surgery and shorter surgery time. With this technique, less postoperative morbidity and delivery of prosthesis for immediate function would be possible. A patient with an edentulous maxilla received 8 implants in maxilla using CAD/CAM surgical templates. Prefabricated provisional maxillary implant supported fixed prosthesis were connected immediately after implant installation. Provisional prosthesis was evaluated for aesthetics, function during 6 months. Definitive implant supported fixed porcelain fused metal bridges were fabricated.

Combined application of roll flap and combination onlay-interpositional graft to enhance esthetics of maxillary anterior fixed partial denture: A case report

  • Oh, Sang-Chun;Cha, Dong-Hee;Lee, Jae-In
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.70-74
    • /
    • 2016
  • In the maxillary anterior region, reconstruction of the localized alveolar ridge defect is very important in enhancing the esthetics of fixed partial denture. A 40-year-old female patient presented with a chief complaint of the inconvenience and unesthetic problem of 3-unit maxillary anterior prosthesis due to alveolar ridge resorption. After removal of old prosthesis, intraoral examination revealed moderate (buccolingually 4 mm) ridge deficiency in missing tooth region, leading to the diagnosis of Class I alveolar ridge defect. One of the reconstruction techniques to overcome this problem might be a technique that combines two types of soft tissue augmentation techniques. The purpose of this paper was to demonstrate the new combined technique of roll flap and combination onlay-interpositional graft utilized to acquire sufficient dimension of recipient area by one time of operation and to present the esthetic improvement of fixed partial denture by using this procedure in case of maxillary anterior localized ridge defect.

Study on Comparison of Dental Prosthesis Condition according by Educational Level (교육수준에 따른 구강 보철물 상태 비교 연구)

  • Kim, Hye Youn;Lee, Mi Hee;Kim, Ji Hye
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.123-129
    • /
    • 2017
  • This study investigated the dental prosthesis condition from the sixth primitive data of Korea National Health and Nutrition Examination Survey to analyze and compare the necessity of existent dental prosthesis condition, dental bridge and dentures in order to determine the real oral health condition by educational level targeting adults aged over 20 years old. From the results, based on demographic-sociologic features, 32.2% of females were under elementary school graduation level, which was lower than males, and the educational level decreased with increasing age, and these trends were statistically significant. As for income level, 45.3% of university graduates had the highest income level and 77.4% of this age group were professionals, which was the highest percentage and was statistically significant. In terms of dental prosthesis condition according to educational level, the under elementary school graduation group had the most dental prosthesis and the greatest need for partial dentures and full dentures. As for the necessary number of fixed implants, the upper jaw had the most number of fixed implants and in the lower jaw, the under middle school graduation needed the most fixed implants.

Single-unit fixed restoration using the automated crown shaping artificial intelligence program (자동 치관 형성 인공지능 프로그램을 이용한 단일 고정성 보철물 수복 증례)

  • Eun-Bi Park;Young-Eun Cho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.169-178
    • /
    • 2024
  • Recently, several attempts have been made to integrate AI into the field of dentistry. To overcome the limitations of traditional fixed prosthetic fabrication methods such as CAD-CAM (computer-aided design-computer-aided manufacturing), AI programs are being developed for automated crown fabrication, and various studies are underway to applicate in clinical situation. In these case studies, single-unit fixed prostheses were fabricated using an AI program (Dentbird Crown, Imagoworks Inc, Seoul, Korea) in both the anterior and posterior regions and the fabrication time and accuracy were compared with previously used CAD-CAM method. The first case is a 44-year-old woman who presented for re-fabrication of a zirconia prosthesis due to a prosthesis fracture on the lingual side of the upper right lateral incisor. The second case is a 53-year-old male patient who presented for a crown restoration on an upper left first molar following root canal treatment, where he received a final zirconia restoration. In both cases, the first prosthesis was designed manually using a CAD program, the second prosthesis was designed using AI alone, and the third prosthesis was designed using AI and then modified by CAD program, and the three designs were superimposed to compare suitability. When evaluated after temporary placement, the final prosthesis demonstrates adequate stability, retention and support, resulting in functional and esthetic satisfaction.

In vitro evaluation methods on adaptation of fixed dental prosthesis (고정성 보철물의 적합도에 대한 실험적 평가방법)

  • Lee, Hyunho;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.63-70
    • /
    • 2017
  • Clinically, the fit of fixed prosthesis is an essential element for successful restoration. The fit of prosthesis is largely classified into marginal fit and internal fit, and various methods to assess these have been introduced including microscopic margin measurement, cross-sectional measurement, silicone replica technique, 3-dimensional scanning data superposition, weight technique and micro CT scanning. Thus, this study is aimed at proposing a more convenient and accurate measurement method of fits in a digital environment by comparatively analyzing the advantages and disadvantages of each known method based on existing literature.

Evaluation of dental panoramic radiographic findings in edentulous jaws: A retrospective study of 743 patients "Radiographic features in edentulous jaws"

  • Kose, Taha Emre;Demirtas, Nihat;Karabas, Hulya Cakir;Ozcan, Ilknur
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.5
    • /
    • pp.380-385
    • /
    • 2015
  • PURPOSE. The aim of this study was to determine the frequency of significant panoramic radiographic findings and eventual treatment requirements before conventional or implant supported prosthetic treatment in asymptomatic edentulous patients. MATERIALS AND METHODS. A total of 743 asymptomatic edentulous patients were retrospectively evaluated using a digital panoramic system. We analyzed the radiographic findings, including impacted teeth, retained root fragments, foreign bodies, severe atrophy of the posterior maxillary alveolar bone, mucous retention cysts, soft tissue calcifications and radiopaque-radiolucent conditions. RESULTS. Four-hundred-eighty-seven (65.6%) patients had no radiographic finding. A total of 331 radiographic findings were detected in 256 (34%) patients. In 52.9% (n=175) of these conditions, surgical treatment was required before application of implant-supported fixed prosthesis. However, before application of conventional removable prosthesis surgical treatment was required for 6% (n=20) of these conditions. CONCLUSION. The edentulous patients who will have implant placement for implant-supported fixed prosthesis can frequently require additional surgical procedures to eliminate pathological conditions.

Autotransplantation in patient who is not indicated fixed prosthesis: case report (고정성 보철 수복이 부적절한 환자에서 자가치아이식을 응용한 치험례)

  • Baek, Sang-Hyeon;Jeong, Hye-Sim;Seong, Sang-Jin;Mun, Yun-Sik;Jang, Hyeon-Ho;Ra, Yun-Sik
    • The Journal of the Korean dental association
    • /
    • v.42 no.8 s.423
    • /
    • pp.514-522
    • /
    • 2004
  • Clinicians often meet the growing patient who is not treated with fixed prosthesis until alveolar bone growth is completed. When both esthetic and function needs are important, and if proper donor tooth is present, the application of autotransplantation may be better treatment option than space maintainer. Although prognosis of autotransplantation is not always favorable, it depends on the treatment design which is based on the ability of case selection and consideration. This report will present the clinical cases of autotransplantation in growing patient, and discuss about several clinical aspects of autotransplantation.

  • PDF

Occlusal adjustment of natural teeth and fixed prosthesis (자연치아와 고정성 보철물의 실전 교합조정)

  • Seo, Jae-Min
    • The Journal of the Korean dental association
    • /
    • v.53 no.6
    • /
    • pp.402-410
    • /
    • 2015
  • The aims of occlusal adjustment are as follows: to eliminate occlusal interference, to redirect force generated during function to which is favorable for teeth, to improve mastication efficiency and simultaneously establish stable maximal intercuspation or centric occlusion. Also, it should permit mandible to move freely from all positions. The sequence of occlusal adjustment in natural teeth and fixed prosthesis shall be as follows: 1) Eliminate interference that prevent optimal intercuspation and recontouring adjustment 2) Establish maximal intercuspation 3) Eliminate interference in lateral mandibular movement 4) Eliminate interference in anterior mandibular movement 5) Refine occlusal relationships.

Burnishing effect on marginal misfit of implant-supported screw-and-cement retained prostheses: A case report (임플란트 지지 나사-시멘트 유지형 보철물에서 보철물-지대주 제거 후 변연부 연마의 효과: 증례보고)

  • Kim, Mijoo;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.239-243
    • /
    • 2020
  • When the marginal fit of fixed dental prosthesis decreases, biological and technical complications, such as plaque accumulation, periodontal disease, hypersensitivity, components fracture, cement loss, can happen. The complications affect the long-term success and survival of prostheses. This case report describes a clinical procedure to minimize the marginal gap of implant-supported screw-and-cement retained prosthesis by removing prosthesis-abutment complex and burnishing the interface area. The marginal gap was measured before and after the burnishing using a stereomicroscope and compared. This technique improves the marginal fit, thereby contributing the longevity of the prosthesis.

Research for the Standard Model of the Items of the National Qualification Examination for the Dental Technician (치과기공사국가시험 문항개발기준안연구)

  • Lee, Duck-Hye;Chung, In-Sung;Han, Chang-Sik
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.75-93
    • /
    • 2002
  • This research was preformed for the purpose of preparing the items of standard model of the national dental technician test base on the duty analysis of the dental technician. The results of the duty analysis for the dental technician follows. 1. The dental technician is a profession to make the oral function smooth through the dental supplement and equipment in a scientific method and the skilled technique. 2. The duty of the dental technician are determined as A. preparation for manufacture B. manufacture C. management of the place of the dental technology D. self-development. A. The field of "the preparation for manufacture" are determined as 1. to confirm work authorization 2. To confirm the working model, B. The field of "In manufacture" are determined as 1. to manufacture the temporary crown 2. to manufacture the inlay and crown & bridge prosthesis 3. to manufacture the porcelain fused metal crown prosthesis 4. to manufacture the all ceramic crown prosthesis 5. to manufacture the temporary denture prosthesis 6. to manufacture the partial denture prosthesis 7. to manufacture the complete denture prosthesis 8. to manufacture the attachment prosthesis 9. to manufacture implant prosthesis 10. to manufacture the removable orthodontic device, 11. to manufacture the fixed orthodontic device, 12. to manufacture the orthodontic study cast C. The field of "in management of the dental lab." are determined as 1. management 2. to control the dental lab. D. The field of "In the self-development" are determined as 1. to improve the professionalism 2. self-control. 3. The developing items selected under the duty evaluation of the dental technician are l7s in the manufacture preparation, 1,011s in the manufacture, 7s in the management for the dental technology, 5s in self-development, and in all together 1,040s

  • PDF