• Title/Summary/Keyword: Fixation (%)

Search Result 2,831, Processing Time 0.033 seconds

Surface Electrochemical Study on the Fixation Properties of New Water-borne Preservatives in Red Pine (새로운 수용성(水溶性) 방부방충제(防腐防蟲劑)의 재중(材中) 정착성(定着性)에 관한 계면전기화학적(界面電氣化學的) 특성(特性))

  • Kim, Yeong-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.93-99
    • /
    • 1996
  • In order to investigate the extent of fixation of new water-borne preservatives in blocks of pinus densiflora sapwoods the streaming potential through the column with preservative treated wood was measured at various conditions. The rates of leachability of ingredients in the treated wood were estimated by the measurement of electric conductivity of the solution with the leached components. The solution was also analyzed by Atomic absorption spectrophotometer (AA). As a results, the experimental data indicated that the fixation of CCB, CCFZ and ACQ in wood were relatively unstable. The fixation rates of CCB, CCFZ were improved by increasing heat and drying time. The amounts of the leached ingredients were apparently higher in CCB and CCFZ than in CCA, while the rate of leaching of ACQ was not changed at various drying temperature.

  • PDF

Is an Arthroscopically Assisted Reduction and Fixation Necessary in the Medial Malleolar Fracture of the Ankle? (족관절 내과 골절시 보조적 관절경적 정복 및 내고정술이 필요한가?)

  • Shin, Dong Min;Ju, Pyong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.93-96
    • /
    • 1998
  • We treated 10 cases of the medial malleolar fracture of the ankle by open reduction and internal fixation from June 1997 to December 1997. After the rigid internal fixation, we measured the gap of the fracture site and the step off of the articular surface by special instrument under the ankle arthroscopy whether it was reduced anatomically or not. And we tried to know the necessity of the arthroscopically assisted reduction and fixation in the medial malleolar fracture of the ankle. Under the arthroscopic view, all 10 cases were anatomically reduced as less than 1 mm of gap of the fracture site and less than 1mm of step off of the articular surface after open reduction and internal fixation in the medial malleolar fractures. In conclusion, through the arthroscopic management, it has advantage in finding and treating the accompanying intraarticular lesion, but also has disadvantage in setting the arthroscope and prolonging the operation time.

  • PDF

A Prototype of Robotic External Fixation System for Surgery of Bone Deformity Correction

  • Kim, Yoon-Hyuk;Joo, Sang-Min;Lee, Soon-Geul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2448-2450
    • /
    • 2005
  • A robotic external fixation system for the surgery of bone deformity correction was developed to simulate the execution process of mal-unioned femur by the adjustment of the joints of the fixation system. An inverse kinematics analysis algorithm was developed to calculate the necessary rotations and translations at each joint of the robotic system. The computer graphic model was developed for validation of the analysis result and visualization of the surgical process. For given rotational and angular deformity case, the surgical execution process using the robotic system was well matched with the pre-operative planning. The final residual rotational deformities were within $1.0^{\circ}{\sim}1.6^{\circ}$ after surgical correction process. The presented robotic system with computer-aided planning can be useful for knowledge-based fracture treatment and bone deformity correction under external fixation.

  • PDF

반연속식과 직렬식 공정에서 Chlorella sp. HA-1의 $CO_2$ 고정화 특성

  • Lee, Jae-Yeong;Gwon, Tae-Sun;Yang, Ji-Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.455-456
    • /
    • 2000
  • Characteristics of $CO_2$ fixation by Chlorella sp. HA-1 were studied in a semi-continuous mode in a series operation. A high $CO_2$ fixation rate for a long time was obtained, when the method of semi-continuous mode was employed, in which the controlling parameter was the dilution ratio. A constant $CO_2$ fixation rate was maintained even when the dilution ratio was increased with the increment of 0.1 at the initial value of 0.5. The method of series operation was used to improve the efficiency of $CO_2$ fixation. The total amount of $CO_2$ fixation was proportion to the number of reactor in series operation.

  • PDF

A CLINICAL STUDY ON THE ATTACHMENT-FIXATION OVERDENTURE (I) - Preliminary Periodontal Status Study - (ATTACHMENT-FIXATION OVERDENTURE에 관한 임상적 연구(I))

  • Yang, Jae-Ho
    • The Journal of the Korean dental association
    • /
    • v.22 no.11 s.186
    • /
    • pp.953-960
    • /
    • 1984
  • The author applied the attachment fixation overdenture on the patient whose residual alveolar ridge height was poor to increase mechanical denture retention, and observed the periodontal condition of the abutment roots after insertion of attachment fixation overdenture. The author obtained the conclusions as follows; 1. Attachment fixation overdenture showed better mechanical retention than conventional overdenture did, but it resulted unfavorable crown-root ratio. 2. Within one year after insertion, there were not significant changes in periodontal health, which was indicated by plaque index, gingival index, pocket depth, tooth mobility gingival hyperplasia and alveolar bone change. 3. Mild periodontal thickening was observed. 4. This study emphasized the importance of adequate follow-up care and home care instructions.

  • PDF

Minimal incision Wolter Plate Fixation on the Displaced Lateral End Fracture of the Clavicle and the Acromioclayicular Dislocation (견봉쇄골탈구와 원위쇄골골절에서 소절개를 이용한 Wolter금속판 내고정술)

  • Ko, Sang-Hun
    • Clinics in Shoulder and Elbow
    • /
    • v.5 no.1
    • /
    • pp.23-28
    • /
    • 2002
  • Purpose Displaced lateral end fracture of clavicle and acromioclavicular dislocation type Ⅲ∼Ⅵ may be required surgical treatment. Material and Methods : From May 1998 to March 2001, we operated with Welter plate with minimal incision by one surgeon. Immediately, pendulum and passive exercise was initiated after surgery. The shoulder function was evaluated using UCLA score. Average follow up was on 28(12∼45) months. Results : All 11 patients were regained satisfactory function. Average UCLA score was 31.9(29~35) at last follow up. Conclusion . The merit of Welter plate fixation with minimal incision is simple technique, reduced surgical time, smaller scar than large plate, strong fixation, early exercise, reduced implant failure. The disadvantage is expensive, skin irritatatation by long hook. But Welter plate fixation with minimal incision is a good method of internal fixation and excellent clinical result in surgical treatment of type H displaced lateral end fracture of the clavicle and type Ⅲ∼Ⅵ acromioclavicular dislocation.

Cement Augmentation for Lateral Row Fixation in Rotator Cuff Repair: A Case Report

  • Kim, Jin Hwan;Koh, Kyoung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.1
    • /
    • pp.42-45
    • /
    • 2017
  • One of the most important factors leading to a successful healing of rotator cuff tear is good bone quality to secure the suture anchor in the bone for a stable fixation. However, rotator cuff tear are commonly found in elderly patients, and their proximal humerus often shows osteoporosis or cystic lesions. Especially when the transosseous repair prevails for a torn rotator cuff, a weak metaphyseal cancellous bone is often the case, which associated with difficulty in stable fixation of the lateral row suture anchor. In this situation, we were able to augment the lateral row fixation with polymethylmethacrylate bone cement. Although there is a concern of disturbance in the blood flow and healing potential, our case showed good clinical results with respect to healing. If we suspect a weak fixation of the lateral row suture anchor, bone cement seems to be a good option for augmentation.

Studies on $CO_2$-Fixation Ability and Photorespiration in Ginseng Leaves (인삼 잎의 $CO_2$ 고정능과 광호흡에 관한 연구)

  • 이인철
    • Journal of Plant Biology
    • /
    • v.25 no.3
    • /
    • pp.105-111
    • /
    • 1982
  • These studies were undertaken to elucidate the reasons for the low productivity of ginseng by comparing the rate of $CO_2$-fixation and photorespiration, variation in the amounts of intermediates and enzyme activities of glycolate oxidase and catalase in ginseng with those of potato. The ability of $CO_2$-fixation in ginseng was found to be one half of that of potato and there were significant differences between those two plants in the rate of $^{14}C$ incorporated into glutamate, aspartate, malate and 3-PGA, but little differences in P-glycolate, glycolate, serine and glycine. The ratio of photorespiration to dark respiration and the activities of glycolate oxidase and catalase in the two species were about same, but ginseng showed higher ratio in photorespiration to total $CO_2$-fixation than potato did. These results indicated that the low productivity of ginseng may resulted from the low $CO_2$-fixation ability and high rate of photorespiration.

  • PDF

How to Get Well-Preserved Samples for Transmission Electron Microscopy

  • Park, Chang-Hyun;Kim, Hyun-Wook;Rhyu, Im Joo;Uhm, Chang-Sub
    • Applied Microscopy
    • /
    • v.46 no.4
    • /
    • pp.188-192
    • /
    • 2016
  • Proper sample preparation prior to microscopy is necessary for maintaining the components of tissues in a state as close to a living state as possible. For optimal preservation of biological samples, the sampling conditions are as important as the fixation itself. Various factors influence the selection and fixation efficiencies of a fixative, including sample size, osmolarity, pH, penetration rate and depth, fixative temperature, fixation time, fixative concentration, fixative amount, and retention time. Therefore, several factors for selecting and administering fixation procedures are evaluated pertaining to optimal sample preparation for transmission electron microscopy.

Atlantoaxial Rotatory Fixation - Report of 3 Cases - (Atlantoaxial Rotatory Fixation - 3 례 보 고 -)

  • Sohn, Moon Jun;Rhim, Seung Chul;Roh, Sung Woo;Park, Hyung Chun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.4
    • /
    • pp.580-585
    • /
    • 2000
  • The atlantoaxial rotatory fixation is a uncommon disease of deformity, occuring much more frequently in children than in adults. Despite of its benign clinical course, delayed recognition or improper management may cause persistent deformity or recurrence. We report three cases of typical atlantoaxial rotatory fixation. Successful reduction was achieved with posterior atlantoaxial fusion in one case and nonoperative treatment in others. We emphasize that it is necessary to perform dynamic CT scan to obtain correct diagnosis and to plan proper treatment for this disease entity.

  • PDF