• Title/Summary/Keyword: Five phase

Search Result 1,087, Processing Time 0.034 seconds

Evaluation Technique of Linearity of Ratio Error and Phase Angle Error of Voltage Transformer Comparison Measurement System Using Capacitor Burden (전기용량 부담을 이용한 전압변성기 비교 측정 시스템의 비오차 및 위상각 오차의 직선성 평가기술)

  • Jung Jae Kap;Kim Han Jun;Kwon Sung Won;Kim Myung Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.6
    • /
    • pp.274-278
    • /
    • 2005
  • Voltage transformer(VT) comparison measurement system is usually used for measurements of ratio error and phase angle error of VT made in industry. Both ratio error and phase angle error in VT are critically influenced by values of burden of VT used. External burden effects on both ratio error and phase angle error in VT are theoretically calculated. From the theoretical calculation, a method of evaluation for linearity of ratio error and phase angle error in VT measurement system have been developed using the standard capacitive burdens, with negligible dissipation factor less than 10$^{-4}$. These burden consists of five standard capacitors, with nominal capacitance of 1.1 $\mu$F, 1 $\mu$F, 0.1 $\mu$F, 0.01 $\mu$F, 0.001 $\mu$F. The developed method has been applied in VT measurement system of industry, showing in good consistency and linearity within 0.001 $\%$ between theoretical and measured values.

The Annual Reproductive Cycle of Silurus microdorsalis, a Korean Endemic Species

  • KI, Se-Un;LEE, Won-Kyo
    • Development and Reproduction
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • The annual reproductive cycle of the Korean endemic slender catfish, Silurus microdorsalis, was examined histologically regarding water temperature and day length of habitat, gonadosomatic index (GSI), and development characteristics of female and male gonads. The maximum GSI value was found in May, $1.23{\pm}0.33$ and $11.77{\pm}3.23$ for male and female respectively (habitat water temperature $21.5^{\circ}C/13.59hr$ day length). On the other hand, the minimal level was $0.63{\pm}0.10$ in July ($26.5^{\circ}C/14.17$) for male and $1.36{\pm}0.08$ in October ($20^{\circ}C/11.2hr$) for female. We compared and calculated the stages of testis and ovary development process in order to determine the germ cell development characteristics and the reproductive cycle. According to results, we classified the annual reproductive cycle of the slender catfish into five stages: Growing phase (December-February), Mature phase (March-April), Ripe and spawning phase / Releasing phase in male (May-June), Degenerative phase (July-August), and Resting phase (September-November).

Numerical Study of Heat Transfer with Selective Phase Change in Two Different Phase Change Materials (이종 PCM의 선택적 상변화 시의 열전달 해석)

  • Kim, Hyung Kuk;Lee, Dong Gyu;Peck, Jong Hyeon;Kang, Chaedong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.9
    • /
    • pp.477-483
    • /
    • 2013
  • A numerical analysis of solid-liquid phase change was performed on a heat transfer module which consisted of circulating water path (BRINE), heat transfer plate (HTP) and phase change material (PCM) layers, such as high temperature PCM (HPCM, $78{\sim}79^{\circ}C$) and low temperature PCM (LPCM, $28{\sim}29^{\circ}C$). There were five arrangements, consisting of BRINE, HTP, LPCM and HPCM layers in the heat transfer module. The time and heat transfer rate for melting/solidification was compared to their arrangements, against each other. As results, the numerical time without convection was longer than the experimental one for melting/solidification. Moreover, the melting/solidification with the BRINE I-LPCM-BRINE II-HPCM arrangement was faster(10 hours) than the others; HPCM-BRINE-LPCM, BRINE I-HPCM-LPCM-BRINE II one.

An Analytical Method of Formaldehyde in Exhaust Gases from Industrial Facilities using a HPLC under Isocratic Conditions (Isocratic 조건하에서 HPLC를 이용한 산업시설 배출가스 중 포름 알데하이드 분석)

  • Kim, Jun-Pyo;Park, Seung-Shik;Bae, Min-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.4
    • /
    • pp.616-624
    • /
    • 2018
  • In this study, a previous DNPH (2,4-dinitrophenylhydrazine) coupled with high performance liquid chromatography (HPLC) method to measure the concentration of formaldehyde in ambient and source environments has been improved. To improve the disadvantage of the previous HPLC method, an appropriate composition ratio of mobile phase (water: acetonitrile (ACN)) was determined and an isocratic analysis was conducted. Furthermore, limit of detection (LOD), limit of quantitation(LOQ), accuracy, and precision were investigated to verify the reliability of the analytical conditions determined. Finally, samples of exhaust gases from five different industrial facilities were applied to HPLC analytial method proposed to determine their formaldehyde concentrations. The appropriate composition ratio of the mobile phase under the isocratic condition was a mixture of water(40%) and ACN(60%). As the volume fraction of the organic solvent ACN increases, retention time of the formaldehyde peak was reduced. Detection time of formaldehyde peak determined using the proposed isocratic method was reduced from 7 minutes(previous HPLC method) to approximately 3 minutes. LOD, LOQ, accuracy, and precision of the formaldehyde determined using standard solutions were 0.787 ppm, 2.507 ppm, 93.1%, and 0.33%, respectively, all of which are within their recommended ranges. Average concentrations of the formaldehyde in five exhaust gases ranged from 0.054 ppm to 1.159 ppm. The lowest concentration (0.054 ppm) was found at samples from waste gas incinerator in a bisphenol-A manufacturing plant. The highest was observed at samples from the absorption process in manufacturing facilities of chemicals including formaldehyde and hexamine. The analytical time of the formaldehyde in ambient air can be shortened by using the isocratic analytical method under appropriate mobile phase conditions.

Opening Status of the Korea Midwifery Birthing Centers and Development of Midwifery Practice Guideline (한국 조산원 개원실태 및 조산직무지침 개발)

  • Song, Ji Young;Park, Young-Joo
    • Journal of Korean Academy of Nursing
    • /
    • v.50 no.4
    • /
    • pp.583-598
    • /
    • 2020
  • Purpose: This study was to investigate the operational status of the midwifery birthing centers (MBCs) and midwives' job status (Phase 1) and to develop midwifery practice guidelines (MPG) (Phase 2) in Korea. Methods: In the first phase, the subjects were 15 midwives who operated 11 of 14 MBCs that were opened as of August 2018. The questionnaire consisted of items to measure the operational status of the MBC and midwives' job status. In the second phase, the MPG was developed from literature review, interviews with five midwives opening their MBCs, surveys with 74 midwives, and a validity evaluation conducted by seven experts. Results: The distribution of operating MBCs was five in Gyunggi-do, two each in Seoul and Incheon, one each in Busan, Chungcheongbuk-do, Gyeongsangbuk-do, Gyeongsangnam-do and Jeju-do. The mean age of midwives was 54.3 and all were female. In 2017, a total of 762 births including 81 homebirths were performed by midwives. The job performance was highest in the order of neonatal care 3.81, childbirth care 3.56, and postpartal care 3.53, respectively. The MPG included seven areas of prenatal care, childbirth care, postpartal care, neonatal care, primary health care, law/ethics, and administration, with 56 tasks and 166 task elements. Conclusion: This study provides the valid basic data for the operational status of the MBC and the midwives' job status. The MPG describes the midwife's job and may be used as basic data for preparing policies for the development of midwifery practice in Korea.

A Smoke Detection Method based on Video for Early Fire-Alarming System (조기 화재 경보 시스템을 위한 비디오 기반 연기 감지 방법)

  • Truong, Tung X.;Kim, Jong-Myon
    • The KIPS Transactions:PartB
    • /
    • v.18B no.4
    • /
    • pp.213-220
    • /
    • 2011
  • This paper proposes an effective, four-stage smoke detection method based on video that provides emergency response in the event of unexpected hazards in early fire-alarming systems. In the first phase, an approximate median method is used to segment moving regions in the present frame of video. In the second phase, a color segmentation of smoke is performed to select candidate smoke regions from these moving regions. In the third phase, a feature extraction algorithm is used to extract five feature parameters of smoke by analyzing characteristics of the candidate smoke regions such as area randomness and motion of smoke. In the fourth phase, extracted five parameters of smoke are used as an input for a K-nearest neighbor (KNN) algorithm to identify whether the candidate smoke regions are smoke or non-smoke. Experimental results indicate that the proposed four-stage smoke detection method outperforms other algorithms in terms of smoke detection, providing a low false alarm rate and high reliability in open and large spaces.

Azimuth Accuracy Test of Phase Comparison Direction Finding Method Using F-16 Fighter Scale-down Model (F-16 전투기 축소모델을 사용한 위상비교 방향 탐지 기법의 방위각 정확도 시험)

  • Lim, Joong-Soo;Chae, Gyoo-Soo;Kim, Young-Ho;Kim, Kichul
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.5
    • /
    • pp.83-88
    • /
    • 2017
  • This paper describes the azimuth accuracy test of phase comparison direction finding method using F-16 fighter scale-down model. When the antennas are placed on the bottom of a fighter, reflection signals caused by an aircraft structure arises and an azimuth error occurs. In this research, the F-16 fighter scale-down model was made to 5:1, and five antennas were placed on the bottom of the model, then the radio waves of emitters were received by the antennas in the $0-360^{\circ}$ azimuth angles. The accuracy test was performed by numerically analyzing the phases of the radio waves received by the five antennas. The azimuth error of the phase comparison direction finding with scale-down model was measured to be less than $0.5^{\circ}$ when the signal noise ratio was larger then 0dB, and it could be very useful for the design of the phase comparison direction finding method of the fighter.

Study on the Application of Five Phases Theory to the Joints of the Limbs from the Viewpoint of Ha-Do Based on I-Ching (하도(河圖) 원리로 본 사지관절(四肢關節)의 오행(五行)배속 연구)

  • Kim, Byoung-Soo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.6
    • /
    • pp.1374-1377
    • /
    • 2008
  • The aim of this study is to explore the principle that the joints of the limbs belong to Five Phases in Korean medicine. According to the principle of I-Ching, Ha-Do provides the logic which could attach everything to Five Phases. Ha-Do is composed of the numbers from one through ten, and in order to explain the logic of Universe formation, it furnishes the method of transforming 'immateriality' into 'materiality'. If we apply formation theory of Ha-Do to the joints of the limbs, however, it could be understood that the trunk of body develops the appendages, which means Ha-Do suggests a logic that 'materiality' generates 'materiality' in this case. Therefore, it is not the Water but the Earth that occurs first in the appendages development in this theory, and the shoulder joints belong to the Earth. Following development should occur in order of Five Phases formation of Ha-Do ; that is to say, the elbow joints belong to the Water, the wrist joints belong to the Fire, the finger joints belong to the Wood, and the ends of fingers belong to the Metal.

Direct Torque Control of Five-leg Dual-PMSM Drive Systems for Fault-tolerant Purposes

  • Wang, Wei;Zhang, Jinghao;Cheng, Ming;Cao, Ruiwu
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.161-171
    • /
    • 2017
  • To enhance the reliability of two-motor drive systems, this paper proposes an improved direct torque control (DTC) scheme (P-DTC) for five-leg dual-PMSM drive systems. First, the topology of a five-leg dual-PMSM drive system is illustrated. To clarify the analysis of the P-DTC, the standard DTC scheme for three-phase drive systems is presented. The operation of a five-leg dual-PMSM drive system is classified into three situations according to the definitions of the switching-vector unions. Compared with the existing DTC scheme (R-DTC), the P-DTC can minimize the replacement of active switching-vectors to zero switching-vectors. When this replacement cannot be avoided, the P-DTC uses a proposed master-slave selection principle to minimize the system error. Comparing with the R-DTC, the P-DTC has lower torque ripples, a wider speed range and a faster torque increasing response. Experiments have been carried out in the coupling and independent modes, and the effectiveness of the P-DTC is verified by the obtained results.

VCO Design using NAND Gate for Low Power Application

  • Kumar, Manoj
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.650-656
    • /
    • 2016
  • Voltage controlled oscillator (VCO) is widely used circuit component in high-performance microprocessors and modern communication systems as a frequency source. In present work, VCO designs using the different combination of NAND gates with three transistors and CMOS inverter are reported. Three, five and seven stages ring VCO circuits are designed. Coarse and fine tuning have been done using two different supply sources. The frequency with coarse tuning varies from 3.31 GHz to 5.60 GHz in three stages, 1.77 GHz to 3.26 GHz in five stages and 1.27 GHz to 2.32 GHz in seven stages VCO respectively. Moreover, for fine tuning frequency varies from 3.70 GHz to 3.94 GHz in three stages, 2.04 GHz to 2.18 GHz in five stages and 1.43 GHz to 1.58 GHz in seven stages VCO respectively. Results of power consumption and phase noise for the VCO circuits are also been reported. Results of proposed VCO circuits have been compared with previously reported circuits and present circuit approach show significant improvement.