• Title/Summary/Keyword: Fitting parameters

Search Result 711, Processing Time 0.035 seconds

A Study on Extracting the Parasitic and Intrinsic Parameters of Equivalent Circuit for Schottky Barrier Diode (Schottky barrier 다이오드의 외부 기생 소자 및 내부 소자 추출에 관한 연구)

  • 조동준;김영훈;최민수;양승인;전용구
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2000.11a
    • /
    • pp.248-251
    • /
    • 2000
  • 본 논문에서는 SIEMENS사의 BAS125 소자의 I-V curve에서 RF신호를 고려하여 파라미터를 추출하였으며, 바이어스에 독립적인 외부소자를 추출하고, 바이어스에 종속적인 접합캐패시터를 S-parameter를 fitting하여 추출하였다.

  • PDF

Pad and Parasitic Modeling for MOSFET Devices (MOSFET 기생성분 모델링)

  • 최용태;김기철;김병성
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.181-184
    • /
    • 1999
  • This paper presents the accurate deembeding method for pad and parasitics of MOSFET device. rad effects are deembedded using THRU LINE, which is much simpler method without laborious fitting procedure compared with conventional OPEN and SHORT pad modeling. Parasitic resistance extraction uses the algebraic relation between increments of inversion layer charge and oxide capacitance. It is especially adequate for insulating gate junction device. Extracted parasitics are verified through comparing modeled and measured S parameters.

  • PDF

SURFACE BRIGHTNESS AND MASS DISTRIBUTION OF THE LATE TYPE SPIRAL GALAXY NGC 2403

  • Lee, Yoo-Mi;Chun, Mun-Suk
    • Journal of The Korean Astronomical Society
    • /
    • v.22 no.1
    • /
    • pp.31-41
    • /
    • 1989
  • Luminosity profile of the late type spiral galaxy NGC 2403 was obtained using the PDS scan of the plate. Some physical parameters (scale length, total magnitude, central brightness, disk to bulge ratio and concentric indices) were calculated from the brightness distribution. Total mass and the mass to luminosity ratio were estimated from the fitting of various mass models.

  • PDF

Hypersonic Viscous Interaction of Wedge Flows (극초음속 쐐기 유동의 Viscous Interaction)

  • Kim K. H.;Rho O. H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1996.05a
    • /
    • pp.40-45
    • /
    • 1996
  • This paper discribes the viscous interaction of Hypersonic Wedge Flows using Roe FDS and AUSM+. For this purpose we developed the frozen and the equilibrium code and numerically simulated the viscous interaction by changing the surface temperature and the mach number. We used curve fitting data in NASA Reference Publication 1181, 1260 to calculate equilibrium properties. We compare the equilibrium flow with the frozen flow. We conclude that the mach number and the surface temperature are significant parameters, as the surface temperature and the mach number increase the viscous interaction becomes stronger, and we must consider high-temperature effects in hypersonic flow

  • PDF

Comparison of EKF and UKF on Training the Artificial Neural Network

  • Kim, Dae-Hak
    • Journal of the Korean Data and Information Science Society
    • /
    • v.15 no.2
    • /
    • pp.499-506
    • /
    • 2004
  • The Unscented Kalman Filter is known to outperform the Extended Kalman Filter for the nonlinear state estimation with a significance advantage that it does not require the computation of Jacobian but EKF has a competitive advantage to the UKF on the performance time. We compare both algorithms on training the artificial neural network. The validation data set is used to estimate parameters which are supposed to result in better fitting for the test data set. Experimental results are presented which indicate the performance of both algorithms.

  • PDF

Three-Dimensional Positioning Using EROS A Stereo Pairs

  • Teo, Tee-Ann;Chen, Liang-Chien
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.606-608
    • /
    • 2003
  • This paper investigates the accuracy of three-dimensional positioning for EROS A stereo pairs when different numbers of ground control points are employed. The major works of the proposed schemes include: (1) initialization of orientation parameters (2) preliminary orbit fitting, (3) orbit refinement using the least squares filtering technique, and (4) space intersection. The experiment includes validation of positioning accuracy for an EROS A in-track stereo pair when different number of check points are employed.

  • PDF

One-step Least Squares Fitting of Variogram

  • Choi, Hye-Mi
    • Communications for Statistical Applications and Methods
    • /
    • v.12 no.2
    • /
    • pp.539-544
    • /
    • 2005
  • In this paper, we propose the one-step least squares method based on the squared differences to estimate the parameters of the variogram used for spatial data modelling, and discuss its asymptotic efficiency. The proposed method does not require to specify lags of interest and partition lags, so that we can delete the subjectiveness and ambiguity originated from the lag selection in estimating spatial dependence.

Analysis on the Depressing Force to the Cornea by Fitted Spherical Contact Lens (구면 콘택트렌즈의 피팅에 따른 각막 부착력 해석)

  • Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.97-106
    • /
    • 2011
  • Purpose: This review article was written to theoretically compare the depressing force (pressure, adhesion) to the cornea between when the spherical lenses were being tightly and flat fitted. Methods: Mathematical equations and their numerical solution programs (model) were formulated to calculate the depressing (adhesion) force to the cornea by both the tightly and flat fitted contact lenses. Based on this proposed model the effects of parameters characterizing a contact lens such as BCs, diameters, edge shape and corneal shape (ratio of long and short corneal axis, p) on the depressing force to the cornea were predicted/analyzed in both tightly and flat fitting regimes. Results: Corneal adhesion increased as the corneal p-value increased. Adhesion increase caused by the increased p-value was much larger in flat fitted case than in tight fitted one. Corneal adhesion reduced abruptly as the BC increased in flat fitting regimes while the adhesion rise was insignificant in tight fitting ones. Reduction in corneal adhesion due to lens-size increase was predicted to be insignificant in both tight and flat fitting regimes. Both the lens edge shape (edge angle) and thickness were relevant only in tight fitting regime. Corneal adhesion increased as the increased with tight-fitted lenses. As the thickness of tight fitted lenses increased, corneal adhesion inversely decreased. Conclusions: The two most significantly affecting the depressing force to cornea were found to be the degree of corneal bending toward the periphery and the BCs of lenses.

Sound Characteristics and Hand of Fabrics for Blouse (블라우스용 직물의 소리 특성과 태)

  • 이은주;조길수
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.4
    • /
    • pp.605-615
    • /
    • 2000
  • This study was carried out to investigate sound characteristics including sound parameters and subjective sensation, and primary hand values related with sound of fabrics for blouse, and furthermore to predict subjective sound sensation with mechanical properties and sound parameters. Sound of specimens was analyzed by FFT. Level pressure of total sound(LPT), loudness(Z), coefficients of autoregressive(AR) functions for fitting the spectra, and sound color factors(ΔL and Δf) were obtained as sound parameters. Primary hand values for women's thin dress were calculated by using KES-FB. Subjective sensation for sound including softness, loudness, sharpness, clearness, roughness, highness, and pleasantness was evaluated by free modulus magnitude estimation. The results were as follows; 1. Fabrics for blouse showed similar spectral shapes to one another in that amplitude values were lower in most ranges of frequencies than fabrics for other uses. 2. It was found that fabrics for blouse were less louder because LPT, loudness(Z), and ARC values were lower than other fabrics. 3. Primary hand values indicated that specimens were soft-touched, flexible, and less crisp. Among primary hands related with sound, Shari values were higher for silk fabrics than for synthetic ones, while the values for Kishimi were similar, 4. Fabrics for blouse were rated more highly for softness, clearness, and pleasantness than for loudness, sharpness. roughness, and highness. Silk fabrics were evaluated more pleasant than synthetic fabrics. 5. Subjective sensation for sound of blouse fabrics were predicted with mechanical properties and physical sound parameters.

  • PDF