• Title/Summary/Keyword: First molar

Search Result 1,022, Processing Time 0.024 seconds

Investigation of the effects of storage time on the dimensional accuracy of impression materials using cone beam computed tomography

  • Alkurt, Murat;Duymus, Zeynep Yesil;Dedeoglu, Numan
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.380-387
    • /
    • 2016
  • PURPOSE. The storage conditions of impressions affect the dimensional accuracy of the impression materials. The aim of the study was to assess the effects of storage time on dimensional accuracy of five different impression materials by cone beam computed tomography (CBCT). MATERIALS AND METHODS. Polyether (Impregum), hydrocolloid (Hydrogum and Alginoplast), and silicone (Zetaflow and Honigum) impression materials were used for impressions taken from an acrylic master model. The impressions were poured and subjected to four different storage times: immediate use, and 1, 3, and 5 days of storage. Line 1 (between right and left first molar mesiobuccal cusp tips) and Line 2 (between right and left canine tips) were measured on a CBCT scanned model, and time dependent mean differences were analyzed by two-way univariate and Duncan's test (${\alpha}=.05$). RESULTS. For Line 1, the total mean difference of Impregum and Hydrogum were statistically different from Alginoplast (P<.05), while Zetaflow and Honigum had smaller discrepancies. Alginoplast resulted in more difference than the other impressions (P<.05). For Line 2, the total mean difference of Impregum was statistically different from the other impressions. Significant differences were observed in Line 1 and Line 2 for the different storage periods (P<.05). CONCLUSION. The dimensional accuracy of impression material is clinically acceptable if the impression material is stored in suitable conditions.

Comparison of safety and analgesic efficacy of diclofenac sodium with etodolac after surgical extraction of third molars: a randomized, double-blind, double-dummy, parallel-group study

  • Vaghela, Jitendra H.;Shah, Jigna H.;Patel, Jaladhi H.;Purohit, Bhargav M.
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.1
    • /
    • pp.19-27
    • /
    • 2020
  • Background: Surgical extraction of third molars is associated with postoperative pain and swelling at the extraction site. Pain is commonly managed using non-steroidal anti-inflammatory drugs (NSAIDs). Postoperative pain is usually moderate to severe in the first 12 h postoperatively and lasts for 3-5 days. However, with NSAIDs, these symptoms usually subside within 24 h. Diclofenac sodium and etodolac are NSAIDs, more selectively cyclooxygenase-2 inhibitors, with good analgesic efficacies. Methods: We compared the safety and analgesic efficacy of diclofenac sodium with etodolac peroral after surgical extraction of third molars in a double-blind, double-dummy, parallel-group study. The subjective pain improvement and pain relief after 2, 6, 24, 48, and 72 h using the visual analogue scale were measured as the study outcome. Results: Etodolac was equivalent to diclofenac sodium in pain alleviation at all postoperative time periods. No significant differences were found between diclofenac sodium and etodolac groups (P > 0.05). Both study medications were well tolerated and safe with mild adverse effects in only a few participants. Conclusion: Diclofenac sodium and etodolac are comparable in terms of analgesic efficacy and safety after surgical removal of third molars.

Mongolian Gerbil as a Novel Animal Model for Ligature-induced Periodontitis

  • Jang, Sungil;Bak, Eun-Jung
    • International Journal of Oral Biology
    • /
    • v.41 no.4
    • /
    • pp.225-230
    • /
    • 2016
  • Inflammation from chronic and acute infections of distal organs and tissues such as periodontitis is a risk factor for atherosclerotic vascular processes. Recently, a new model of atherosclerosis with vascular pathologies was developed in the Mongolian gerbil. In this study, we attempted to develop a model of ligature-induced periodontitis in gerbils and compared the characteristics of that periodontitis model with that in rats and mice. Each gerbil, rat, and mouse was randomly assigned to groups of control and periodontitis. A thread was placed around the cervix of the right and left first molars in the mandible with knots placed on the mesial side of each molar. At day 14 after the ligation, the animals were sacrificed and their mandibles were dissected. To measure alveolar bone loss along with inflammation, histopathological and micro-CT analyses were carried out. Gerbils showed tooth characteristics of deeper gingival crevice, longer cusp, longer root trunk and shorter root than those of rats and mice. The increased CEJ-ABC distance in distal and PDL area in furcation was also observed in ligated gerbils. An inflammatory response in the connective tissue under the junctional epithelium was also shown in all the animals. As a result, we confirmed the induction of periodontitis by ligature in the gerbils. We therefore consider the gerbil to be a useful model for investigating relationship between periodontitis and vascular disease in the same animal.

Eagle′s syndrome: report of two cases using computed tomography (전산화단층사진을 포함한 Eagle 증후군의 증례보고)

  • Lee Sul-Mi;Kwon Hyuk-Rok;Choi Hang-Moon;Park In-Woo
    • Imaging Science in Dentistry
    • /
    • v.32 no.2
    • /
    • pp.119-122
    • /
    • 2002
  • Two cases of Eagle's syndrome are reported. The first case involved a 31-year-old man who complained of pain in his throat and pain at preauricular area on turning his head. Panoramic and computed tomography (CT) views showed bilateral stylohyoid ligament ossification. The symptoms were relieved after surgical removal. The second case involved a 56-year-old female whose chief complaints were a continuous dull pain and occasional 'shooting' pain on lower left molar area. During the physical examination, an ossified stylohyoid ligament was palpated at the left submandibular area. Panoramic and CT images showed prominent bilateral stylohyoid ligament ossification. CT scans also showed hypertrophy of left medial and lateral pterygoid muscles. The symptoms were relieved after medication. CT is a useful tool for the examination of ossified stylohyoid ligaments and studying the relationship between Eagle's syndrome and adjacent soft tissue.

  • PDF

Evaluation of the marginal and internal fit of lithium disilicate crowns fabricated by different scanning methods (다른 스캐닝 방법으로 제작된 리튬 디실리케이트 단관의 변연 및 내면 적합도 평가)

  • Kim, Jae-Hong;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.36 no.2
    • /
    • pp.75-81
    • /
    • 2014
  • Purpose: This study was to compare adaptations of lithium disilicate CAD/CAM crowns fabricated with different scanning systems. Methods: This study selected the mandibular right first molar as an abutment for experiments and produced 10 working models. Lithium disilicate crowns appropriate for each abutment were produced by using a CEREC$^{(R)}$ CAD/CAM system. The independent t-test was then used to compare and analyze the data obtained from the two groups(${\alpha}$=0.05). Results: Mean(SD) adaptation were $86.93(22.82){\mu}m$ for the InS group, $88.42(26.77){\mu}m$ for the ExS group. They were no statistically significant differences between groups for adaptation(p>0.05). Conclusion: Within the limitations of this study, the results suggest that the accuracy of all investigated optical scanner were satisfactory for clinical use. Further assessment and improvement of the lithium disilicate ceramic for the fabrication of FPDs is evidently still required.

Nano-particles of Mechanochemical Synthesis

  • Urakaev, Farit Kh.
    • Journal of the Speleological Society of Korea
    • /
    • no.71
    • /
    • pp.5-11
    • /
    • 2006
  • A theoretical investigation of the solid phase mechanochemical synthesis of nano sized target product on the basis of dilution of the initial powdered reagent mixture by another product of an exchange reaction is presented. On the basis of the proposed 3 mode particle size distribution in mechanically activated mixture, optimal molar ratios of the components in mixture are calculated, providing the occurrence of impact friction contacts of reagent particles and excluding aggregation of the nanosized particles of the target reaction product. Derivation of kinetic equations for mechanochemical synthesis of nanoscale particles by the final product dilution method in the systems of exchange reactions is submitted. On the basis of obtained equations the necessary times of mechanical activation for complete course of mechanochemical reactions are designed. Kinetics of solid phase mechanosynthesis of nano TlCl by dilution of initial (2NaCl+$Tl_2SO_4$) mixture with the exchange reaction product (diluent,$zNa_2SO_4$, z=z*=11.25) was studied experimentally. Some peculiar features of the reaction mechanism were found. Parameters of the kinetic curve of nano TlCl obtained experimentally were compared with those for the model reaction KBr+TlCl+zKCl=(z+1) KCl+TlBr (z=z1*=13.5), and for the first time the value of mass transfer coefficient in a mechanochemical reactor with mobile milling balls was evaluated. Dynamics of the size change was followed for nanoparticle reaction product as a function of mechanical activation time.

Stress Analysis of Posterior Porcelain-Fused-to-Metal Crown by Marginal Configurations (구치부(臼齒部) 도재전장주조관(陶在前裝鑄造冠) 변연형태(邊緣形態)에 따른 응력분석(應力分析))

  • Kim, Kwang-Seok;Song, Kwang-Yup;Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.161-179
    • /
    • 1987
  • To study the mechanical behaviors of the margins of porcelain-fused-to-metal crown on the posterior teeth, 5 types of margins on the lower first molar were chosen, and then the finite element models were constructed. 50kg forces were applied to the porcelain on the axial wall supported by the metal vertically. The displacements and stresses of the porcelain-fused-to-metal crown were analyzed to investigate the influence of the type of margins. The results were as follows; 1. High tensile stresses were exhibited on the porcelain of the portion of the coronal line angle insufficient metallic support. 2. In case metal coping had a good supporting form to vertical force, uniform compressive stresses were exhibited on their supporting form. 3. Tensile stresses in the inframetallic margin on the series of the shoulder with a bevel margins were decreased in the bevel portion. 4. Principal stresses on the metal of the chamfer marginal portion were decreased comparing with the series of the shoulder margins. 5. The noticeable compressive stress gradients were exhibited between axial cement layer and metal on the series of the shoulder margins. 6. The principal stresses on the marginal cement layer were higher than that of the occlusal surface and axial wall.

  • PDF

EFFECT OF INNER WALL TEMPERATURE CONDITION OF TUBULAR REACTOR ON PRODUCTION OF BY-PRODUCT FOR ETHANE CRACKING PROCESS (에탄 열분해 공정에서 관형 반응기 내벽 온도 조건이 부산물 생성에 미치는 영향)

  • Shin, C.Y.;Kim, H.J.;Ahn, J.
    • Journal of computational fluids engineering
    • /
    • v.21 no.3
    • /
    • pp.110-117
    • /
    • 2016
  • It is a essential to minimize production of by-products for economically effective petrochemical process. In order to find key factor to achieve the effective process, 2-dimensional computational fluid dynamics considering a variety of physics such as convective and radiative heat transfer and thermal cracking of ethane are carried out. The reactor is modeled as an isothermal tube, whose length is 1.2 m and radius is 0.01 m, respectively. At first, the axial distribution of representative by-products in ethane thermal cracking are investigated in each inner wall temperature conditions. Then the comparison between concentration of propene($C_3H_6$) and ethane conversion is discussed with respect to inner wall temperature conditions too. Finally, both reaction rate and turbulent kinetic energy are used to identify the production mechanism of $C_3H_6$ under the intersection point in the plot for $C_3H_6$ molar concentration and ethane conversion.

THE INFLUENCE OF IMPRESSION MATERIALS ON THE ACCURACY OF THE STONE CASTS POURED FROM COMPLETE ARCH IMPRESSION (전악인상채득시 인상재가 경석고 모형의 정확도에 미치는 영향)

  • Lee, Soo-Young;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.207-218
    • /
    • 1993
  • The purpose of this study was to evaluate the reproducing accuracy of stone casts made from complete arch impressions using different impression materials. The impression materials studied were 1) polyether, 2) polysulfide, 3) polyvinyl siloxane, and 4) irreversible hydrocolloid. Impressions were made from a partially edentulous acrylic resin model with metal inserts in canine, first molar region bilaterally and mid palatal vault region. Each distance between 2 out of 5 meauring points was measured by using 3dimensional measuring machine. Impressions were poured at once with a type IV dental stone. Data were analyzed using t-test with a sample size of six. The results were as follow : 1. Polysulfide and polyether were significantly superior to polyvinyl siloxane and irreversible hydrocolloid in reproducing full arch model(p<0.05), but there were no statistical differences in amount of dimensional reproducing accuracy for full arch impression between polysulfide and polyether(p>0.05). 2. There were statistical differences in amount of dimensional reproducing accuracy between edentulous area and tooth bound area for polysulfide and polyether(p<0.05). but no statistical differences were observed for polyvinyl siloxane and irreversible hydrocolloid(p>0.05).

  • PDF

A EXPERIMENTAL STUDY OF RESTORATIVE TECHNIQUES FOR ENDODONTICALLY TREATED POSTERIOR TEETH (근관충전후 수복술식이 치아파절에 미치는 영향에 관한 실험적 연구)

  • Ahn, Jong-Gill;Choi, Sung-Keun
    • Restorative Dentistry and Endodontics
    • /
    • v.8 no.1
    • /
    • pp.53-59
    • /
    • 1982
  • An in vitro study was performed in order to evaluate the restoring methods in the endodontically treated molar teeth. 68 extracted teeth were divided into 4 groups according to the restoring techniques. The teeth of first group were restored by amalgam. Those of second group were restored by the stainless steel post and amalgam. The teeth of the third group were restored by the amalgam with crown. The teeth of the fourth group were restored by the stainless steel post and amalgam core with crown. All the specimens were tested and measured for the fracture load by means of the Instron (UTM-111-500 Toyo Baldwin Co., LTD. Japan) and the Pressure Instrument (Yonsei University, Department of Metal Engineering.) The results were as follows; 1. There were no statistical differences in the fracture loads between the amalgam restoration and post-amalgam core restorative techniques. 2. The techniques of amalgam core with crown showed lower fracture loads those of post and amalgam core with crown. 3. In the crowned teeth, they presented higher fracture loads than those without crown.

  • PDF