• Title/Summary/Keyword: First half cycle

Search Result 75, Processing Time 0.022 seconds

Development of an analysis model for the first half cycle non-limiting type Hybrid SFCL (22.9kV 반주기후한류방식 복합형 초전도한류기 해석모델 개발)

  • Lee, Seung-Ryul;Yoon, Jae-Young;Lee, Byong-Jun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.1
    • /
    • pp.6-11
    • /
    • 2010
  • For real power system application of SFCL, it is necessary to develop an analysis model of the SFCL. In Korea, hybrid SFCL of the first half cycle non-limiting type have been jointly developed by KEPRI and LS Industrial Systems through DAPAS program. In this study, we developed a PSCAD/EMTDC analysis model of the hybrid SFCL of the first half cycle non-limiting type. The simulation results of the developed model are in agreement with the test results of the real SFCL. The developed SFCL model is tested in real power system model.

Comparative Analysis on Current Limiting Characteristics of Hybrid Superconducting Fault Current Limiters (SFCLs) with First Half Cycle Limiting and Non-Limiting Operations

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.5
    • /
    • pp.659-663
    • /
    • 2012
  • The application of large power transformer into a power distribution system was inevitable due to the increase of power demand and distributed generation. However, the decrease of the power transformer's impedance caused the short-circuit current of the power distribution system to be increase thus, the higher short-circuit current exceeded the cut-off ratings of the protective devices such as circuit breaker. To solve these problems, several countermeasures have been proposed to protect the power system effectively from higher fault current and the superconducting fault current limiter (SFCL) has been expected to be the promising countermeasure. In spite of excellent current limiting performances of the SFCL, on the other hand, the efforts to apply the SFCL into power system has been delayed due to both the limited spaces for the SFCL's installation and its long recovery time after the fault removal. In order to solve these problems, a hybrid SFCL, which can perform either first half cycle limiting of first half cycle non-limiting operation, has been developed by corporation of LSIS (LS Industrial System) and KEPCO (Korea Electric Power Corporation). In this paper, we tried to requirements hybrid SFCL by PSCAD/EMTDC. Simulation results of our analysis of the hybrid SFCL is that its accompanied the characteristics both the limit the fault current and quick recovery caused by the less impact from superconductor.

Analysis on Operation Characteristics of Hybrid Superconductor Fault Current Limiter(SFCL) with First Half Cycle Non-Limiting Operation (반주기 이후 하이브리드 초전도 전류제한기의 동작 특성 분석)

  • You, Il-Kyoung;Kim, Jin-Seok;Kim, Myoung-Hoo;Lim, Sung-Hun;Kim, Jae-Chul;Choi, Jong-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.239-244
    • /
    • 2011
  • Due to large demand, the increase of fault current has caused the capacity of power machines in power grid to increase. Among several countermeasures, the superconducting fault current limiter (SFCL) has been noticed as one of the promising countermeasures to solve these problems. However, in spite of excellent current limiting performances of the SFCL, the application of SFCL to power system has been delayed due to both the limited space for the SFCL's installation and its longer recovery time after the fault removal. In order to solve these problems, a hybrid type SFCL was developed. In this paper, we studied the operation characteristics of the hybrid SFCL with first half cycle non-limiting operation by modelling using PSCAD/EMTDC and experiment. It was shown through the simulation using PSCAD/EMTDC and the simulated experiment that the fault current limiting and the fast recovery operations of the hybrid SFCL with the first half cycle non-limiting operation were achieved.

A New Digital Distance Relaying Algorithm Based on Fast Haar Transformation Techniques with Half a Cycle Offset Free Data (Offset이 제거된 반주기 테이터를 사용하는 고속Haar 변환에 기초한 디지털 거리계전 알고리)

  • 강상희;박종근
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.9
    • /
    • pp.973-983
    • /
    • 1992
  • A very fast algorithm, using fast Haar transformation with half a cycle dc-offset free data, to extract the power frequency components and to detect faults in power systems is proposed. For the speed-up, two important techniques are used. First, according to the symmetric characteristics of sine and cosine functions, fundamental frequency components are calculated with only half a cycle sample data. For using these characteristics, post-fault de-offset components must be removed beforehand. Therefore, secondly, a newly designed digital filter is used to remove exponentially decaying dc-offset from the post-fault signal. In accordance with series simulations, transmission line faults can be detected in around half a cycle after faults.

Analysis on Current Limiting Characteristics of a Hybrid SFCL with the First Half Cycle Limiting Operation Due to Resistance of Superconducting Element (초전도소자의 저항변화에 따른 반주기내 한류형 하이브리드 초전도 전류제한기의 전류제한 특성 분석)

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul;Choi, Jong-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1817-1822
    • /
    • 2011
  • The fault current has been increasing due to expansive substation facilities for meeting the increase of demand. To limit increasing fault current in a power system, among methods the superconducting fault current limiter (SFCL) has been considered to be adopted in the power grid. However, in case of adopting SFCL in the power system, most of SFCLs need to solve problems such as recovery, cost. With efforts to solve those problems, the novel fault current limiting device which is called hybrid SFCL is developed. To apply the hybrid SFCL, it has to be needed to analyze application possibility and itself operation characteristics. In this paper, the fault current limiting and operation characteristics of hybrid SFCL with first half cycle the limiting operation in case of various resistances of superconducting element were analyzed through experiment.

Surface Encoder Based on the Half-shaded Square Patterns (HSSP)

  • Lee, Sang-Heon;Jung, Kwang-Suk;Park, Eui-Sang;Shim, Ki-Bon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.3
    • /
    • pp.82-84
    • /
    • 2008
  • A surface encoder based on the Half-shaded square pattern (HSSP) is presented. The HSSP working as reference grid is composed of the straight lines which are easy to be fabricated and make measuring time short. Since the periodic cell is separated in ON/OFF by the $45^{\circ}$ straight line, the duration from the starting point of scanning to the first rising edge and the duty cycle of the pulse train vary with respect to the position of the starting point. And the relationship between X and Y position and the duration, and duty cycle is described in the simple linear equation. Therefore, it is possible to measure X and Y position with the measured duration and duty cycle without calculating load. Through the test set-up, the feasibility of the proposed surface encoder was verified. Also the future works for improvement of performance were suggested.

Investigation of Network Application of the Hybrid SFCLs (복합형 초전도 한류기의 한류특성에 따른 계통 적용성 검토)

  • Choe, Won-Joon;Sim, Jung-Wook;Park, Kwon-Bae;Kim, Young-Gun;Oh, Il-Sung;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.223-225
    • /
    • 2008
  • In order to apply SFCLs into electric power systems, the urgent issues to be settled are as follows, such as initial installation price, operation and maintenance cost due to ac loss of superconductor and the life of cryostat, and high voltage and high current problems. We designed novel hybrid SFCLs which combine superconductor and conventional electric equipments including a vacuum interrupter, an electro-magnetic contactor and a current limiting reactor. The main purpose of the hybrid SFCL is to drastically reduce total usage of superconductor by adopting current commutation method by use of the superconductor and the fast switch. According to protective coordination and performance, we investigated two concepts of Hybrid SFCLs. First is a half cycle fault current limitation type and second is a non-half cycle fault current limitation type. We concluded that the non-half cycle fault current limitation type is batter than the other.

  • PDF

PROSPECTIVE ON DEVELOPMENT OF NUCLEAR POWER AND THE ASSOCIATED FUEL CYCLE IN CHINA

  • Gu Zhongmao;Liu Changxin;Fu Manchang
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.156-164
    • /
    • 2005
  • The challenges China is facing in energy security are briefly discussed. Then, the development of nuclear power in China in the first half of 21 st century is envisioned, and it is expected that Generation-3 PWR nuclear power plants (NPPs) would be the leading units of nuclear power in the coming $30\~40$ years. As part of the nuclear power program, the R&D work on nuclear fuel cycle is generally proposed.

  • PDF

Analysis on the Protective Coordination with Hybrid Superconducting Fault Current Limiter (반주기 이후 동작 하이브리드 초전도 전류제한기와 보호기기 협조 분석)

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul;Choi, Jong-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1832-1837
    • /
    • 2011
  • The fault current has increased due to the large power demand in power distribution system and network distribution system. To protect the power system effectively from the increased fault current, the superconducting fault current limiter (SFCL) has been notified. However, the conventional SFCL has some problems such as cost, operation, recovery, loss. To solve some problems, the hybrid superconducting fault current limiter using the fast switch was proposed. However, hybrid SFCL also has a problem that is protection coordination in power distribution system with hybrid SFCL. In this paper, the fault current limiting characteristics of hybrid SFCL with first half cycle non-limiting operation according to the fault angle, the resistance of superconducting element, and the magnitude of Current Limit Resistor (CLR) which are the components of hybrid SFCL were analyzed through the experiments.

Assessing the long-term durability and degradation of rocks under freezing-thawing cycles

  • Seyed Zanyar Seyed Mousavi;Mohammad Rezaei
    • Geomechanics and Engineering
    • /
    • v.34 no.1
    • /
    • pp.51-67
    • /
    • 2023
  • In this research, the degradation rate of physical properties of the Angouran pit bedrock (calc-schist) is first investigated under the specific numbers of freeze-thaw (F-T) cycles. Then, the durability of calc-schist specimens against the F-T cycle number (N) is examined considering the mechanical parameters, and using the decay function and half-time techniques. For this purpose, point load strength (IS(50)), second durability index (Id2), Brazilian tensile strength (BTS), and compressive (VP) and shear (VS) wave velocities of calc-schist specimens are measured after 0, 7, 15, 40, and 75 N. For comparing the degradation rate of mechanical properties of available rock types on the Angouran mine walls, these tests are also carried out on the limestone and amphibolite schist specimens beside the calc-schist. According to test results, the exponential regression models are developed between the mechanical parameters of rock specimen's and N variable. Also, the long-term durability of each rock type versus N is studied using the decay function and half-time techniques. Results indicated that the degradation rate differs for the above rock types in which amphibolite schist and calc-schist specimens have the highest and least resistance against the N, respectively. The obtained results from this study can play a key role in the optimal design of the mine's final walls.