Analysis on Operation Characteristics of Hybrid Superconductor Fault Current Limiter(SFCL) with First Half Cycle Non-Limiting Operation |
You, Il-Kyoung
(숭실대 공대 전기공학부)
Kim, Jin-Seok (숭실대 공대 전기공학부) Kim, Myoung-Hoo (숭실대 공대 전기공학부) Lim, Sung-Hun (숭실대 공대 전기공학부) Kim, Jae-Chul (숭실대 공대 전기공학부) Choi, Jong-Soo (한국전기안전공사) |
1 | H. R. Kim, S. W. Yim, O. B. Hyun, J. Sim, and S. Y. Oh, "Analysis on recovery characteristics of superconducting fault current limiters", MT-20 Confernce on Magnet Technology. |
2 | O. B. Hyun, J. W. Sim, h. R. Kim, K. B. Park, S. W. Yim, and I. S. Oh, "Reliability Enhancement of the Fast Switch in a Hybrid Superconducting Fault Current Limiter by Using Power Electronic Switches", IEEE Trans. Appl. Supercond., Vol. 19, No. 3, pp. 1843-1846, June. 2009. DOI ScienceOn |
3 | I. SHIMIZU, Y. NAITO, I. YAMAGUCHI, K. KAIHO, S. YANABU, "Application Study of a High-Temperature Superconducting Fault Current Limiter for Electric Power System", Electrical Engineering in Japan, Vol. 155, No. 4, pp. 20-29, Apr. 2006. DOI ScienceOn |
4 | B. W. Lee, K. B. Park, J. Sim,I. S. Oh, H. G. Lee, H. R. Kim, and O. B. Hyun, "Design and Experiments of Novel Hybrid Type Superconducting Fault Current Limiters", IEEE Trans. Appl. Supercond., Vol. 18, No. 2, pp. 624-627, June. 2008. DOI ScienceOn |
5 | 김준환, 이강완, "전력계통 고장전류 증대와 대응방안," 전기저널, pp. 19-31, 1998. |
6 | O. B. Hyun, K. B. Park, J. W. Sim, H. R. Kim, S. W. Yim, and I. S. Oh, "Introduction of a Hybrid SFCL in KEPCO Grid and Local Points at Issue", IEEE Trans. Appl. Supercond., Vol. 19, No. 3, pp. 1946-1949, June. 2009. DOI ScienceOn |
7 | O. B. Hyun, H. R. Kim, Y. S. Yim, J. Sim, K. B. Park, I. S. Oh, "Domestic Efforts for SFCL Application and Hybrid SFCL", Progress, Supercond., Vol. 10, No. 1, pp. 60-67, Oct. 2008. |
8 | H. Kameda, and H. Taniguchi, "Setting Mothod of Specific Parameter of a Superconducting Fault Current Limiter Considering the Operation of Power System Protcetion", IEEE Trans. Appl Superconduct., Vol. 9, No. 2, pp. 1355-1360, June. 1999. DOI ScienceOn |
9 | S. H. Lim, "Operational Characteristics of Flux-Lock Type SFCL With Series Connection of Two Coils", IEEE Trans. Appl. Supercond., Vol. 17, No. 2, pp. 1895-1898, June. 2007. DOI ScienceOn |
10 | I. K. You, J. S. Kim, M. H. Kim, S. H. Lim, J. F. Moon, J. C. Kim, "Current Limiting Characteristics due to Location of Superconducting Fault Current Limiter in Power Distribution System", KIIEE Spring Annual Conference 2009. |
11 | 조승식, "최신 배전시스템 공학," 북스힐, pp. 396-469, 2006. |
12 | 김진석, "배전변전소에 대용량 변압기 설치시 초전도 전류제한기 적용방안 연구", 숭실대학교 일반대학원 |