• Title/Summary/Keyword: First flush

Search Result 165, Processing Time 0.028 seconds

Demonstration Study of Half-Saturated Bio-filter Wetland with Recirculation Pump for Road Stormwater (반포화 순환 여과식 인공습지에 의한 도로 강우유출수의 실증처리 연구)

  • Park, Kisoo;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.19 no.3
    • /
    • pp.259-270
    • /
    • 2017
  • In this study, field-scale half-saturated bio-filter wetland equipped with recirculation system was operated with stormwater from the paved road, and its operational performance and functions of LID-BMP were analyzed and compared with other facilities. The reduction of TSS, COD, TN, and TP were 92%, 63%, 36%, and 75%, respectively. Comparison of the reduction efficiency were carried out with respect to ratio between surface and catchment areas(SA/CA). In addition, this LID-BMP facility can reduce about 70% of pollutant by treating only 18% of total rainfall runoff. The results show that LID used for this study gave similar efficiency although its ratio was smaller. In addition, comparison study was made between synthetic fiber as a filter media and organic media, which shows that there was not any significant difference between, TSS and TP reduction, but there were large difference in COD and TN removal due to the presence and absence of release of organic carbon. Meanwhile, wetland system in this study equipped with a first-flush capture gave a higher stability in terms of treatment performance.

The Performance of Pollutant Removal Using Nonpoint Treatment Filtration Device and Analysis of the Filter Backwashing Effect (여과형 비점오염 처리장치의 오염물질 제거특성 및 역세척 분석)

  • Lee, Jun-ho;Yang, Seung-ho;Bang, Ki-woong
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.5
    • /
    • pp.523-532
    • /
    • 2015
  • Hydrocyclone is widely used in industry, for its simple design, high capacity, low maintenance and low operational cost. The objective of this study is to develop hydrocyclone coagulation and filtration system. The system is made of hydrocyclone ballasted coagulation with polyaluminium chloride silicate (PACS) and upflow filter to treat micro particles in urban storm runoff. Roadside sediment particles (< $200{\mu}m$) was mixed with tap water to make various turbid suspensions to simulate urban storm runoff. The filter cartridge was filled with polyethylene media system and ran 1hr per everyday and total operation time were 8.19hrs and backwashing everyday after end of operation. The operation condition of flowrate was $8.2{\sim}11.9m^3/day$ (mean $10.1m^3/day$) and surface overflow rate (SOR) based on filter surface area was $45.5{\sim}65.9m^3/m^2/day$ (mean $55.7m^3/m^2/day$). The range of PACS dosage concentration was 14.0~31.5 mg/L. As the results of operation, the range of removal efficiency of turbidity, SS were 81.0~95.8% (mean 89.5%) 81.8~99.0% (mean 91.4%), respectively. An increase of filtration basin retention time brought on increased of removal efficiency of turbidity and SS, and increase of SOR brought on decreased of removal efficiency. During the first flush in urban area, storm runoff have an high concentration of SS (200~600 mg/L) and the filtration bed becomes clogged and decreased of removal efficiency. Backwashing begins when the drainage pipe valve at the filtration tank bottom is completely open (backwashing stage 1). Backwashing stage 2 was using air bubbles and water jet washing the media for 5 mins and open the drainage valve. After backwashing stage 1, 2, 61.83~64.04%, 18.53~27.51% of SS loading was discharged from filtration tank, respectively. Discharged SS loading from effluent was 7.12~14.79% and the range of residual SS loading in fliter was 2.26~5.00%. The backwashing effects for turbidity, SS were 89.5%, 91.4%, respectively. The hydrocyclone coagulation and filtration with backwashing system, which came out to solve the problems of the costly exchange filter media, and low efficiency of removing micro particles of filter type nonpoint treatment devices, is considered as an alternative system.

Characteristics of Stormwater Runoff with respect to Pavement Types (도로 포장방법에 따른 비점오염물질 유출특성 비교)

  • Kim, Cheolmin;Choi, Jiyeon;Lee, Jung Min;Cho, Hyejin;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.16 no.3
    • /
    • pp.423-429
    • /
    • 2014
  • Due to high imperviousness rates of the roads, various pollutants originated from vehicle activities and air depositions are accumulated on the road surfaces. The washed-off pollutants can deteriorate the water quality and destroy the aqua-ecosystems with their toxicity. Usually the roads are paved with asphalt and concrete, which can affect on the pollutant concentrations with different frictional forces. Therefore, this research is performed to evaluate the influences of different pavement type on discharged concentrations of pollutant. The results shows the first flush phenomenon was occurred on both pavement types. However, peak concentrations are higher in concrete pavement areas than asphalt pavement because concrete pavement has high contact area with vehicles. The EMCs(Event Mean Concentration) also shows high values in concrete paved roads. As a result of this research, it can be concluded the pavement type is also one of the important affecting factors on pollutant emissions from the roads.

Evaluation of Pollutants Concentrations and Runoff Characteristics in Highway Rest Area (국내 고속도로 휴게소지역 비점오염원 유출특성 분석)

  • Kim, Jeong-Hyun;Kang, Hee-Man;Ko, Seok-Oh
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.131-137
    • /
    • 2010
  • The stormwater runoff from rest areas in highways are known as more polluted compared to highways because of more vehicle activities. This study is performed to find pollutant characteristics in the rest areas in the magnitude of statistical pollutant concentrations during storms. Washoff characteristics of pollutants from rest areas by monitoring of rainfall, runoff rate and runoff samples were evaluated. High concentrations of pollutants in runoff were observed at the beginning of runoff and rapid decrease thereafter, indicating that first-flush effects are clearly occurred. Event Mean Concentrations(EMCs) of TSS, COD, TN, and TP are estimated to be in the range of 31.04-127.11mg/L, 35.5-369.5mg/L, 2.62-9.86 mg/L, and 0.53-1.96mg/L, respectively. Heavy metals in runoff showed relatively high values, possibly due to the abrasion of brake pad or tire while cars are slowly moving for parking. EMCs of total Pb, total Cu, and total Ni are in the range of $1206-16293{\mu}g/L$, $237-7906{\mu}g/L$, and $53-6372{\mu}g/L$, respectively. Pollutant loading per rest area calculated by using EMC, flowrate and target area is also described for each pollutant.

Characteristics of Non-point Pollutant from Highway Toll Gate Landuse (고속도로 영업소지역에서의 비점오염물질 유출특성)

  • Lee, Eun-Ju;Son, Hyun-Geun;Kang, Hee-Man;Kim, Lee-Hyung
    • International Journal of Highway Engineering
    • /
    • v.9 no.4
    • /
    • pp.185-192
    • /
    • 2007
  • Newly constructed road is a requisite to be able to carry out BMPs (Best Management Practices) under TMDL(Total Maximum Daily Load) program of the Ministry of Environment. BMPs require pollutant source control during road construction and wash off reduction plan as well as maintenance practices subsequent to construction on the purpose of discharging the minimum wash off non-point source pollutants. The objective of this study is to provide supportive discharged data in evaluating the discharged non-point pollutant load from a highway toll gate area. It can be applied to manage non-point source pollutants on roads. The results validate the first flush phenomenon that it is known to be one of the wash off characteristics in paved area. In addition, the load per unit area and load per unit rainfall duration applying EMC are calculated. The mean load per unit rainfall duration is assessed to be $533.7mg/m^2-hr$ for TSS, $396.2mg/m^2-hr$ for COD, $17.0mg/m^2-hr$ for TN, and $4.8mg/m^2-hr$ for TP. These results show the unitload taken from monitoring are higher than the unit load suggested in the TMDL. It is important to adopt real pollutant unit for road to be able to perform BMP successfully.

  • PDF

Clogging Potential in Constructed Vertical Flow Wetlands Employing Different Filter Materials for First-flush Urban Stormwater Runoff Treatment (도시 초기 강우유출수 처리를 위한 수직흐름습지에서 여재별 폐색 잠재성 분석)

  • Chen, Yaoping;Guerra, Heidi B.;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.20 no.3
    • /
    • pp.235-242
    • /
    • 2018
  • The function of vertical subsurface flow wetlands can potentially be reduced with time due to clogging and are often assumed to be occurring when ponding and overflow is observed during rainfall. To investigate their clogging potential, three pilot-scale vertical subsurface flow (VSF) wetland systems were constructed employing woodchip, pumice, and volcanic gravel as main media. The systems received stormwater runoff from a highway bridge for seven months, after which the media were taken out and divided into layers to determine the amount and characteristics of the accumulated clogging matters. Findings revealed that the main clogging mechanism was the deposition of suspended solids. This is followed by the growth of biofilm in the media which is more evident in the wetland employing woodchip. Up to more than 30% of the clogging matter were found in the upper 20 cm of the media suggesting that this layer will need replacement once clogging occurs. Moreover, no signs of clogging were observed in all the wetlands during the operation period even though an estimation of at least 2 months without clogging was calculated. This was attributed to the intermittent loading mode of operation that gave way for the decomposition of organic matters during the resting period and potentially restored the pore volume.

Breeding of a new cultivar 'Dadam' for Lentinula edodes sawdust cultivation (표고 톱밥재배용 신품종 '다담' 육성)

  • Kim, Jeong-han;Shin, Bok-Eum;Baek, Il-Sun;Choi, Jong-In;Ha, Tai-Moon;Jung, Gu-Hyun
    • Journal of Mushroom
    • /
    • v.19 no.2
    • /
    • pp.96-102
    • /
    • 2021
  • A new cultivar of oak mushroom 'Dadam' was bred from monokaryotic strains of 'GMLE36062-4' and 'GMLE36288-34'. The optimum temperature for mycelial growth of the new cultivar 'Dadam' on potato dextrose agar was 19-22℃. Total cultivation period of the new cultivar, from innoculation to its first harvest, was 135-139 days, similar to that of the control cultivar 'Hwadam'. The pileus color and stipe thickness of the new cultivar were darker and thinner than those of 'Hwadam'. Total yield of 'Dadam' was 621 g per 3 kg substrate, and is higher than that of 'Hwadam' (371 g). In farmhouse field test, it showed that the period of mycelial growth, browning, and fruiting body formation were the same as those of the control cultivar L808. The number of available fruiting bodies of 'Dadam' was 15, and is lower than that of the control (47), therefore, it was possible to save workforce in thinning. The total yield for 2 flush was 480 g for 'Dadam', similar to the 473 g of the control cultivar.

Characteristics of Newly Bred Lentinula edodes Cultivar 'Jadam' for Sawdust Cultivation (표고 톱밥재배용 신품종 '자담' 육성 및 특성)

  • Jeong-Han Kim;IL-Sun Baek;Jong-In Choi;Bok-Eum Shin;Young-Ju Kang;Tai-Moon Ha;Gu-Hyun Jung;Yeon-Jin Kim;Jun-Yeong Choi
    • The Korean Journal of Mycology
    • /
    • v.50 no.2
    • /
    • pp.93-102
    • /
    • 2022
  • A new cultivar of oak mushroom Lentinula edodes 'Jadam' was bred from monokaryotic strains of 'Hwadam-18' and 'GMLE36295-22'. The optimum temperature for mycelial growth of 'Jadam' on potato dextrose agar was 22-25℃. Total cultivation period of the new cultivar, from inoculation to its first harvest, was 122-124 days, shorter to that of the control cultivar 'Hwadam'. Total yield of 'Jadam' was 623.8 g per 3 kg substrate, and is higher than that of 'Hwadam' (455.2 g). In the fruiting body of the new cultivar, the stipe was shorter and thinner than those of 'Hwadam'. A farmhouse field test showed that the period of mycelial growth and browning was shorter than that of control cultivar 'L808'. The total yield for 2 flush was 543.3 g for 'Jadam'. It was similar to the 585.3 g of the control cultivar. Therefore, the new cultivar 'Jadam' could be a substitute for 'L808' in the field of farms.

The Characteristics and the Effects of Pollutant Loadings from Nonpoint Sources on Water Quality in Suyeong Bay (수영만 수질에 미치는 비점원 오염부하의 특성과 영향)

  • CHO Eun Il;LEE Suk Mo;PARK Chung-Kil
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.3
    • /
    • pp.279-293
    • /
    • 1995
  • The most obvious and easily recognizable sources of potential water pollution are point sources such as domestic and industrial wastes. But recently, the potential effects of nonpoint sources on water quality have been increased apparently. In order to evaluate the characteristics and the effects of nonpoint sources on water quality, this study was performed in Suyeong Bay from May, 1992 to July, 1992. The depth-averaged 2-dimensional numerical model, which consists of the hydrodynamic model and the diffusion model was applied to simulate the water quality in Suyeong Bay. When flowrate was $65.736m^3/s,$ the concentration of pollutants (COD, TSS and VSS) at Oncheon stream (Sebeong bridge) during second flush were very high as much as 121.4mg/l of COD, 1148.0mg/l of TSS and 262.0mg/1 of VSS. When flowrate was 4.686m^3/s, the concentration of pollutants $(TIN,\;NH_4\;^+-\;N,\;NO_2\;^--N\;and\;PO_4\;^{3-}-P)$ during the first flush were very high as much as 20.306mg/1 of TIN, 14.154mg/1 of $NH_4\;^+-N$, 9.571mg/l of $NO_2\;^--N$ and l.785mg/l of $PO_2\;^{3-}-P$ As results of the hydrodynamic model simulation, the computed maximum velocity of tidal currents in Suyeong Bay was 0.3m/s and their direction was clockwise flow for ebb tide and counter clockwise flow for Hood tide. Four different methods were applied for the diffusion simulation in Suyeong Bay. There were the effects for the water quality due to point loads, annual nonpoint loads and nonpoint loads during the wet weather and the investigation period, respectively. The efforts of annual nonpoint loads and nonpoint loads during the wet weather seem to be slightly deteriorated in comparison with the effects of point loads. However, the bay was significantly polluted by the nonpoint loads during the investigation period. In this case, COD and SS concentrations ranged 2.0-30.0mg/l, 7.0- 200.0mg/l in ebb tide, respectively. From these results, it can be emphasized that the large amount of pollutants caused by nonpoint sources during the wet weather were discharged into the bay, and affected significantly to both the water quality and the marine ecosystem. Therefore, it is necessary to consider the loadings of nonpoint pollutants to plan wastewater treatment plant.

  • PDF

Effects of NaCl Concentrations on Production and Yields of Fruiting Body of Oyster Mushrooms, Pleurotus spp. (NaCl의 농도가 느타리버섯 자실체 발생 및 수량에 미치는 영향)

  • Jhune, Chang-Sung;Sul, Hwa-Jin;Kong, Won-Sik;Yoo, Young-Bok;Cheong, Jong-Chun;Chun, Se-Chul
    • The Korean Journal of Mycology
    • /
    • v.34 no.1
    • /
    • pp.39-53
    • /
    • 2006
  • This studies investigated the effect of concentrations of sodium chloride (NaCl) on occurrence and growth of fruitbody in oyster mushrooms, Pleurotus spp. Our experiments divided into two parts. When the water contents in substrate were added with sodium chloride solution in cotton waste box cultivation as a first experiment, the growth of mushroom was damaged as the concentration was increased, even though there was a little difference according to the strains. The yield in 1.0% NaCl solution was decreased to 72% compared to non-treated plot while that in 3.0% solution was only 2% of the non-treated plot. Morphological characteristics of mushrooms cultivated in substrate with the different concentration of the solution showed different results. For example, the size and thickness of pilei were not influenced by NaCl concentration, but the length of stipes and individual weight were much influenced. In plastic box cultivation filled with cotton waste, watering treatment with the different concentrations of sodium chloride solution, the second experiment, did not show any difference according to the concentration until 1.0% solution but there was a little difference according to the strains. The productivity of fruitbody started to decrease at 2.0% of the solution and the yield and quality of mushroom in 3.0% solution treatment were generally low. After the second flush, days for mushroom sprouting were generally prolonged in proportion to the solution concentration. Taken altogether, the second experiment did not show a clear effect as the case of the first experiment.