• Title/Summary/Keyword: Firing Control System

Search Result 157, Processing Time 0.036 seconds

A Fuzzy Logic Controller Design for Maximum Power Extraction of Variable Speed Wind Energy Conversion System (가변 풍력발전 시스템의 최대출력 제어를 위한 Fuzzy 제어기 설계)

  • Kim Jae-gon;Huh Uk-youl;Kim Byung-yoon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.11
    • /
    • pp.753-759
    • /
    • 2004
  • This paper presents a modeling and simulation of a fuzzy controller for maximum power extraction of a grid-connected wind energy conversion system with a link of a rectifier and an inverter. It discusses the maximum power control algorithm for a wind turbine and proposes, in a graphical form, the relationships of wind turbine output, rotor speed, power coefficient, tip-speed ratio with wind speed when the wind turbine is operated under the maximum power control. The control objective is to always extract maximum power from wind and transfer the power to the utility by controlling both the pitch angle of the wind turbine blades and the inverter firing angle. Pitch control method is mechanically complicated, but the control performance is better than that of the stall regulation method. The simulation results performed on MATLAB will show the variation of generator's rotor angle and rotor speed, pitch angle, and generator output.

A Development of 3 Phase Current Balance Control Algorithm (3상 전류평형 제어기술 알고리즘 개발)

  • Cheon, Y.S.;Seong, H.S.;Won, H.J.;Han, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1091-1093
    • /
    • 2001
  • The power semiconductor is widely used in the power plant or industrial field because of genealization and enlargement. It has been controlled and operated according to its own control method. Especially in case of Power plant, it plays a major role in AVR(Automatic Voltage Regulator) or electro chlorination control circuits. Generally, they used in Analog control system at above field. But each SCR current value is different because of load unbalance or switching characteristic variations, it may cause power plant unit trip or system disorder according to SCR element burn out or bad operating condition. Therefore, in this paper a development of 3 phase current balance control algorithm is described. it gets over the past analog control system limit, controls SCR gate firing angle for 3 phase current balance.

  • PDF

Performance of PI Controller for Maximum Power Extraction of a Grid-Connected Wind Energy Conversion System (계통연계 풍력발전 시스템의 최대출력 제어를 위한 PI 제어기의 성능 분석)

  • No, Gyeong-Su;Ryu, Haeng-Su
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.8
    • /
    • pp.391-397
    • /
    • 2002
  • This paper presents a modeling and simulation of a PI controller for maximum power extraction of a grid-connected wind energy conversion system with a link of a rectifier and an inverter. It discusses the maximum power control algorithm fnr a wind turbine and proposes, in a graphical form, the relationships of wind turbine output, rotor speed, power coefficient, tip-speed ratio with wind speed when the wind turbine is operated under the maximum power control. The control objective is to always extract maximum power from wind and transfer the power to the utility by controlling both the Pitch angle of the wind turbine blades and the inverter firing angle. Pitch control method is mechanically complicated, but the control performance is better than that of the stall regulation method. The simulation results performed on MATLAB will show the variation of generator's rotor angle and rotor speed, pitch angle, and generator output.

Design of Fuzzy Controller for Firing Angle of TCSC Using Tabu Search (Tabu Search를 이용한 TCSC의 점호각 제어용 퍼지 제어기의 설계)

  • Kim, Woo-Geun;Hwang, Gi-Hyeon;Mun, Gyeong-Jun;Kim, Hyeong-Su;Park, Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.37-39
    • /
    • 2000
  • This paper describes the application of Fuzzy Logic Controller (FLC) to Thyristor Controlled Series Capacitor (TCSC) which can have significant impact on Power system dynamics. The function of the FLC is to control the firing angle of the TCSC. We tuned the scaling factors of the FLC using Tabu Search. The proposed FLC is used for damping the low frequency oscillations caused by disturbances such as the sudden changes of small of large loads or the outages in the generators or transmission lines. To evaluate usefulness of the proposed FLC. we performed the computer simulation for single-machine infinite system. The response of FLC is compared with that of PD controller optimized using Tabu Search. Simulation results that the FLC shows the better control performance than PD controller.

  • PDF

Application of Tabu Search in Design of Fuzzy Controller for Firing Angle of TCSC Improving Transient Stability (과도 안정도 향상을 위한 TCSC의 점호각 제어용 퍼지제어기의 설계에 Tabu 탐색법의 적용)

  • Kim, U-Geun;Hwang, Gi-Hyeon;Kim, Hyeong-Su;Park, Jun-Ho;Park, Jung-Geun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.12
    • /
    • pp.561-567
    • /
    • 2001
  • This paper describes the application of Fuzzy Logic Controller (FLC) to Thyristor Controlled Series Capacitor (TCSC) which can have significant impact on power system dynamics. The function of the FLC is to control the firing angle of the TCSC. We tuned the scaling factors of the FLC using Tabu Search. The proposed FLC is used for damping the low frequency oscillations caused by disturbances such as the sudden changes of small or large loads or the outages in the generators or transmission lines. To evaluate usefulness of the proposed FLC, we performed the computer simulation fur single-machine infinite system. The response of FLC is compared with that of PD controller optimized using Tabu Search. Simulation results that the FLC shows better control performance than PD controller.

  • PDF

Determination of Optimal Operating Angle for HVDC System (전류형 HVDC 시스템의 최적 운전각 결정)

  • Kim, Jin-Young;Kim, Jae-Han;Kim, Chan-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.7-15
    • /
    • 2012
  • In this paper a process of determination for thyristors operating with optimal angle is described. The proposed method is based on the trade-off between the cost(due to rating and loss) and controllability of the system. Large control angle increases controllability of HVDC system and also increase the rating of the system which leads to a high price. Therefore it is important to determine a control angle at a first step of design procedure. This paper shows a rating trend of C.Tr, Valve and Filter due to control angle variation, and then introduces a determination process of the HVDC operating angle.

A study on DSP based power analyzing and control system by analysis of 3-dimensional space current co-ordinates (3차원 전류좌표계 해석법에 의한 DSP 전력분석 제어장치에 관한 연구)

  • 임영철;정영국;나석환;최찬학;장영학;양승학
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.543-552
    • /
    • 1996
  • The goal of this paper is to developed a DSP based power analyzing and control system by 3-Dimensional (3-D) space current co-ordinates. A developed system is made up of 486-PC and DSP (Digital Signal Processor) board, Active Power Filter, Non-linear thyristor load, and Power analyzing and control program for Windows. Power is analyzed using signal processing techniques based on the correlation between voltage and current waveforms. Since power analysis algorithm is performed by DSP, power analysis is achieved in real-time even under highly dynamic nonlinear loading conditions. Combining control algorithm with power analysis algorithm is performed by DSP, power analysis is achieved in real-time even under highly dynamic nonlinear loading conditions. Combining control algorithm with power analysis algorithm, flexibility of the proposed system which has both power analysis mode and control mode, is greatly enhanced. Non-active power generated while speed of induction motor is controlled by modulating firing angle of thyristor converter, is compensated by Active Power Filter for verifying a developed system. Power analysis results, before/after compensation, are numerically obtained and evaluated. From these results, various graphic screens for time/frequency/3-D current co-ordinate system are displayed on PC. By real-time analysis of power using a developed system, power quality is evaluated, and compared with that of conventional current co-ordinate system. (author). refs., figs. tabs.

  • PDF

Power Flow Control of Thyristor Controlled Shunt Compensator (싸이리스터 제어 병렬 보상기에 의한 전력 제어 연구)

  • 정교범
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.680-683
    • /
    • 1999
  • A thyristor controlled shunt compensator, which is installed in the middle of the transmission line is adopted for controlling real power flow in a simple power transmission system. By means on the Fourier series representation of the thyristor switching action and the system parameters, the thyristor current equations are derived, which transmit the required real power of the simple power transmission system and inform the thyristor firing angle, the thyristor conduction angle, the power flows and the harmonic characteristics EMTP simulations at the various operating points show the dynamic characteristics of the thyristor controlled shunt compensator and correspond to the results calculated with the Fourier series representation.

  • PDF

Algorithm Development for Improving Output Characteristics of Thyristor Dual Converter with AC Input Voltage Variation (교류 입력 전압 변동에 따른 사이리스터 듀얼 컨버터의 출력 특성 개선을 위한 알고리즘 개발)

  • Kim, Sung-An;Han, Sung-Woo;Cho, Yun-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1437-1443
    • /
    • 2017
  • Electric energy is consumed or regenerated according to an operation of electric rail cars in urban railway power substations. A thyristor dual converter system is used to deal with the electric energy. Since the AC input voltage of power substations is $22.9kV{\pm}10%$, the magnitude of the AC voltage fluctuates according to load conditions, so the secondary side voltage of the DDY transformer also fluctuates. In the thyristor dual converter, the response characteristics of the DC output voltage and the DC output current are changed based on an initial firing angle in the cross mode conversion between the forward mode and the reverse mode. Therefore, this paper proposes the initial firing angle tracking algorithm considering fluctuation of the AC input voltage. The effectiveness of the proposed algorithm is verified by a simulation compared with the conventional algorithm.

Lasers in Endodontics (임상가를 위한 특집1 - 근관치료에서의 레이저의 활용)

  • Huh, Sun-Yoon;Rhim, Eun-Mi;Kim, Sun-Young;Park, Sang-Hyuk
    • The Journal of the Korean dental association
    • /
    • v.49 no.11
    • /
    • pp.660-669
    • /
    • 2011
  • Er: YAG laser irradiation utilizing the newly developed RCLase side-firing spiral tip was used for the cleansing of root canals following their bio-mechanical preparation with ProTaper Ni-Ti files. The distal and palatal roots of 20 freshly extracted molar teeth were instrumented to size F3 with ProTaper files. In the experimental group (10 teeth) the pulp chamber and the root canals were filled with EDTA 17% and the root canals were lased for 30 s using the Er: YAG laser irradiation at 600 mJ per pulse and a frequency of 12 Hz. In the control group (10 teeth) the root canals were not lased. Scanning electron microscope analysis showed clean wall surfaces of the lased root canals with open dentinal tubules, free of smear layer and debris. In the scanning electron microscope photographs of the walls of the non-lased root canals a considerable amount of debris could be detected. It appears that an efficient cleansing of the root canal system can be achieved by using the Er: YAG laser irradiation with the RCLase Side-firing Spiral Tip following bio-mechanical preparation of the root canal with Ni-Ti Taper files.