• Title/Summary/Keyword: Fires

Search Result 1,222, Processing Time 0.03 seconds

Research and Analysis of the Causes and Preventive Measures of Fires Caused by a Disposable Gas Lighter (1회용 가스라이터로 인한 화재 원인과 예방대책의 조사·분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • This study analyzed the regulatory actions of disposal gas lighters as well as the situations, causes, and preventive measures of fires, and accidents caused by disposal gas lighters. Since child-resistant lighters became mandatory, the percentage of fires caused by playing with fire has decreased in Korea as it did in America and Japan. Fires caused by disposal gas lighters can occur by afterburning, unintentional lighting, large flames, or explosion or bursting as well as by arson and playing with fire. This study suggests the preventive measures of fires caused by disposal gas lighters as follows: Taking a step not to be used as child's tool for playing with fire, the warning of fire cases caused by afterburning, warning of the dangers of leaving disposal gas lighters on the car dashboard or high temperature places, improving the protective synthetic resin cover of the stop part of a vehicle seat rail, and providing information on precautions for keeping in drawers or disposition methods.

An Forest Ecological Environment Impact Assessment of Forest Fire Suppression Chemicals - To Plants & Soil Organism - (산불 진화용 소화약제의 산림생태환경 영향 평가 - 식물 및 토양생물독성에 대하여 -)

  • Kim, Dong-Hyun;Lee, Myung-Bo;Yoo, Se-Kuel;Na, Young-Eun;Choi, Won-Il;Kim, Eung-Sik;Jung, Ki-Chang
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.48-54
    • /
    • 2008
  • Forest fires occur the world over, with large-scale fires constantly breaking out. A suppressant a type of forest fire chemical is widely used to respond to fires rapidly and effectively. In general, suppressants used for fires have been divided into dry powder, liquid, foam, and gel type, according to physical form and use. This study has conducted toxicity tests relating to phytotoxicity(Pinus densiflora seed germination rate and mortality of containerized seedling), and soil organism toxicity(earthworm acute toxicity tests), of these suppressants, with the loaded stream suppressant for direct forest fire extinguishing a Loaded Stream and foam concentrates generally being used in Korea. From the results of the tests, the loaded stream and the foam concentrate had an effect on the toxicity levels. In the case of the loaded stream type, it was observed that toxicity indicating a 100% lethality rate was found among all toxicity test methods. Therefore, it is determined that forest ecology environmental toxicity impact assessments related to the suppressant used to extinguish forest fires are necessary in the near future.

Construction of Case-based System for the Cause Diagnosis of an Electrical Fires (전기화재 원인진단을 위한 사례기반 시스템 구축)

  • Lee, Jong-Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • Fire Science and Engineering
    • /
    • v.21 no.2 s.66
    • /
    • pp.42-47
    • /
    • 2007
  • This paper presents the development of a case-based system for an electrical fire cause diagnosis system using the entity relation database. The relation database which provides a very simple but powerful way of representing data is widely used. The system focused on database construction and cause diagnosis can diagnose the causes of electrical fires easily and efficiently. In order to store and access to the information concerned with electrical fires, the key index items which identify electrical fires uniquely are derived out. The case-based system consists of a case which contains information from the past fires. The case-based system could present the cause of a newly occurred fire to be diagnosed by searching the case-based database for reasonable matching. The case-based system has not only searching functions with multiple attributes by using the collected various information(such as fire evidence, structure, and weather of a fire scene) but also more improved diagnosis functions which can be easily used for the electrical fire cause diagnosis system.

An Extraction of Solar-contaminated Energy Part from MODIS Middle Infrared Channel Measurement to Detect Forest Fires

  • Park, Wook;Park, Sung-Hwan;Jung, Hyung-Sup;Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.1
    • /
    • pp.39-55
    • /
    • 2019
  • In this study, we have proposed an improved method to detect forest fires by correcting the reflected signals of day images using the middle-wavelength infrared (MWIR) channel. The proposed method is allowed to remove the reflected signals only using the image itself without an existing data source such as a land-cover map or atmospheric data. It includes the processing steps for calculating a solar-reflected signal such as 1) a simple correction model of the atmospheric transmittance for the MWIR channel and 2) calculating the image-based reflectance. We tested the performance of the method using the MODIS product. When compared to the conventional MODIS fire detection algorithm (MOD14 collection 6), the total number of detected fires was improved by approximately 17%. Most of all, the detection of fires improved by approximately 30% in the high reflection areas of the images. Moreover, the false alarm caused by artificial objects was clearly reduced and a confidence level analysis of the undetected fires showed that the proposed method had much better performance. The proposed method would be applicable to most satellite sensors with MWIR and thermal infrared channels. Especially for geostationary satellites such as GOES-R, HIMAWARI-8/9 and GeoKompsat-2A, the short acquisition time would greatly improve the performance of the proposed fire detection algorithm because reflected signals in the geostationary satellite images frequently vary according to solar zenith angle.

Predicting Forest Fires Using Machine Learning Considering Human Factors (인적요인을 고려한 머신러닝 활용 산림화재 예측)

  • Jin-Myeong Jang;Joo-Chan Kim;Hwa-Joong Kim;Kwang-Tae Kim
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.28 no.5
    • /
    • pp.109-126
    • /
    • 2023
  • Early detection of forest fires is essential in preventing large-scale forest fires. Predicting forest fires serves as a vital early detection method, leading to various related studies. However, many previous studies focused solely on climate and geographic factors, overlooking human factors, which significantly contribute to forest fires. This study aims to develop forest fire prediction models that take into account human, weather and geographical factors. This study conducted a comparative analysis of four machine learning models alongside the logistic regression model, using forest fire data from Gangwon-do spanning 2003 to 2020. The results indicate that XG Boost models performed the best (AUC=0.925), closely followed by Random Forest (AUC=0.920), both of which are machine learning techniques. Lastly, the study analyzed the relative importance of various factors through permutation feature importance analysis to derive operational insights. While meteorological factors showed a greater impact compared to human factors, various human factors were also found to be significant.

A Study on the Formations of Thermal Stratification of Furniture Fire (가구화재시 열적성층의 형성에 관한 연구)

  • 허만성
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.24-29
    • /
    • 1996
  • The objective of this research is to study on the formations of thermal stratification in a room in case of several furniture fires such as trashcan, chair, carpet, sofa, mattress and wardrobe as a fire starter in a residential room by performing the experimental studies. The uniformly distributed fire in case of carpet showed that the ignition and the initial growth period were relatively short while the fully developed period was considerably long. The concentrated fires such as the mattress and wardrobe showed that the ignitions and the initial growth periods were relatively long. When fire spread to only one direction, like the case for the trashcan with a regular shape, there was one peak of temperature profile, and for the irregular shaped furniture such as chair, sofa, mattress and wardrobe, there were two or more peaks. The interface heights for the furniture fires were around 1(m) mataining constant state. However, at the time of the maximum temperature, the interface height was lowered to 0.25(m)-0.75(m) from the floor

  • PDF

A Study on Circuit Topology Design for Alarm System Development of Series Arc Fault (직렬 아크사고 경보시스템 개발을 위한 회로 토플로지 설계에 관한 연구)

  • Jung, M.S.;Kwak, D.K.;Choi, J.K.;Kim, K.S.;Park, Y.J.
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.38-39
    • /
    • 2016
  • Most of fires are electric fires and 78.65% of those fires are caused by electric arc fault. This series arc fault can be caused not only by decrepit wire, pressed wire or contact badness etc. anywhere we use electricity. There are signs of heat release and flame discharge before the arc fire accident happens. This paper proposes a circuit topology for alarm system of series arc fault. We also verify the qualification of system through various arc fault simulator.

  • PDF

Numerical Study on the Change in Fire Characteristic as Operating Water-mist in Under-ventilated Compartments (워터미스트 작동에 의한 산소저공급 실내화재 특성 변화에 대한 수치해석 연구)

  • Ko, G.H.;Lee, S.H.;Ryou, H.S.
    • Journal of ILASS-Korea
    • /
    • v.13 no.3
    • /
    • pp.156-161
    • /
    • 2008
  • The present article reports a numerical study on the fire characteristic change by water-mist in under-ventilated compartments. The natural gas and heptane pool fires are used as fire sources, which are located in the bottom center of the 2/5 reduced-scaled model of the ISO 9705 standard room. The fire modeling using the FDS (Fire Dynamics Simulator) is validated by comparison with previously published experimental results. For temperature and combustion gas concentrations at two positions located in the upper layer of compartment, the predicted results with and without water-mist are compared each other. The results show that under the water-mist operation, the predicted temperature and carbon monoxide concentration reduce as $300{\sim}400^{\circ}C$ and about 20%, respectively, compared to those without water-mist.

  • PDF

A Study on the Evaluation Method of the Building Safety Performance and the during Building Fires with Computer Prediction of Occupants′ Egress Behavior Simulation (컴퓨터시뮬레이션에 의한 피난행태예측 및 안전성능평가 방법에 관한 연구(I))

  • 최원령;이경회
    • Fire Science and Engineering
    • /
    • v.3 no.1
    • /
    • pp.19-28
    • /
    • 1989
  • It has been recognized that the escape facility planning is very important for effective evacuation of accupants on fire event. The ultimate goal of the escape facility planning is to evacuate occupants rapidly from building fires to the safe areas. In fire event, occupants usually gather, utilize and finally act upon information about state transient of building fire system, which is consisted of components of fire, building and accupant during the ralatively short period of the fire event. That is, occupants' egress behavior is largely dependent upon building fire system. Therefore, comprehensive study for the relationship between building fire system and occupants' egress behavior is needed. This study aims to suggest the pre -occupancy evaluation method of the life safety performance for the architectural design based on prediction of occupants' egress behavior during building fires with computer simulation.

  • PDF

A Study on Improvement of Domestic Airport Service for Rescue and Fire Fighting (국내 공항 구조 및 소방 업무 개선방안 연구)

  • Han, Jae-Hyun;Chung, Ki-Yeon
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.16 no.4
    • /
    • pp.69-74
    • /
    • 2008
  • Aircraft fires due to accident at an airport may be under a special situation. An outstanding characteristic of aircraft fires is their tendency to reach lethal intensity within a very short time. In domestic aviation act, there are regulations related to services coping with the aircraft accidents within an airport. To cope aircraft fires, it is necessary to define clearly the regulations and standards about the services and related activities of rescue and fire fighting, and to keep the regulations and standards. The study has been performed on the basis of International Civil Aviation Organization (ICAO) Airport Services Manual of rescue and fire fighting. The objective of study is to suggest improvement methods for standards applicable to actual service practices of rescue and fire fighting by analyzing through the comparison of domestic and international regulations and standards.

  • PDF