• Title/Summary/Keyword: Fire-fighting activities

Search Result 39, Processing Time 0.029 seconds

The 2018 Fire department emergency medical technician survey (2018년 소방공무원 응급구조사 총조사)

  • Yun, Hyeongwan;Park, Jooho;Lee, Hyeongyeong;Han, Seungtae;Lee, Jeamin
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.3
    • /
    • pp.145-162
    • /
    • 2021
  • Purpose: The 2018 General survey of emergency assistance was conducted to examine the working conditions and welfare, including educational direction, interests, and awareness of work, of the fire department emergency medical technicians (EMT). This would be used as basic data for future policy directions. Methods: Among the fire-fighting officers in 16 cities nationwide, emergency rescue workers engaged in first-aid activities were targeted. With prior consent, a survey was conducted through electronic documents. Of the total 1,227 people, responses from 1,151 were finally analyzed, excluding 76 who did not respond appropriately. Results: The working conditions and welfare of 119 firefighters were moderate, but in the fields of education and interest, the learning according to the regulations was high. In particular, satisfaction with the scope of work was found to be below average. However, it was positive that it will play a role as a social safety net in the future and will converge with cutting-edge science. Conclusion: Although this study was a total investigation of the EMT survey, conducting an EMT survey on all fire fighters in Korea is difficult. Further research is needed, particularly on first-class emergency medical personnel who play a major role in 119 paramedics.

A study on present status and improvement of protection relay system in subway station for stable power supply (지하철 역사의 안정적 전원공급을 위한 보호시스템 검토)

  • Na, Jong-Woo;Jo, Won-Kang;Park, Dong-Seon;Yoo, Yeon-Seong;Moon, Hwa-Soo
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.433-444
    • /
    • 2008
  • Nowadays, subway station has provided not only transportation but living spaces for everyday activities. Therefore, a variety of facilities have been installed for a safety of citizens such as fire-fighting equipment, platform screen doors and giving high level of benefits such as air-conditioning and heating equipment, escalators, lighting apparatus. In order to operate these facilities appropriately, it is needless to say that electric power supply must be reliable. Many protection relays have been installed to protect electric apparatus and power system, nevertheless it..s study has been insufficient in the concrete. From this paper, through analyzing of protection relay system of electric room operated in line 2 of Seoul metro, we can help to improve stable power supply system of subway station.

  • PDF

Improvement Plan of Fire-Related Laws of Disaster Prevention Facilities of Road Tunnels (도로터널 방재시설의 소방관계법령 개선방안)

  • Seo, Hyo-Seon;Whang, Young-Kwon;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.124-131
    • /
    • 2019
  • When a fire occurs in a road tunnel, it is likely to develop into a major disaster because of its sealed structural characteristics. Because of this, a range of disaster prevention facilities should be installed, and they should show their appropriate functions in fire prevention and response. In addition, the installation of essential disaster prevention facilities is missing due to the lack of considering an extension of continuous tunnels and soundproof tunnels. For these reasons, it was judged that an amendment to the law would be necessary. Therefore, this paper reviewed the changes in domestic laws related to the disaster prevention facilities of road tunnels, and the results of the study on the parts that need to be revised in the fire-related laws through a comparative analysis between laws are as follows. First, consecutive tunnels should consider the sum of the extensions of the individual tunnels and ensure that the soundproof tunnels are included in the category of tunnels in the law. In this way, the necessary disaster prevention facilities should be installed. Second, it is necessary to secure a legal justification for installing disaster prevention facilities in tunnels. Therefore, it is essential that water mist fire extinguishing system facilities, emergency broadcasting facilities, and leading lights, which are excluded from installation in tunnels, are specified in the Fire-related laws. Third, to specify in the law that air respirators must be provided in the tunnel is necessary from the viewpoint of the field response. Accordingly, it will make a great contribution to the fire-fighting activities and the life-saving efforts by fire-fighters.

Experimental Study to Estimate the Required Flow of Fire Extinguishing System for Flame Spread Prevention on Composite Panel (복합패널 화재확산 방지를 위한 소화시스템의 소요유량 산정을 위한 실험적 연구)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Hwi-Seong;Kim, Yang-Kyun
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.33-39
    • /
    • 2017
  • Composite panel refers to the particular plywood produced in a way of stacking the different kinds of material in sandwich form and adhering them using adhesives and is widely used as building material for its constructability and cost efficiency. But as the surface is finished with steel plate, fire extinguishing agent cannot reach to the core material because of such steel plate on surface which causes the difficulties in suppressing the fire as well as in fire-fighting activities due to collapse. This study, to deal with such problem, is intended to set the fire pipe in core material to prevent the fire from spreading and in a bid to achieve this using minimized fire water, water supply test device was fabricated to estimate the required water flow of fire extinguisher and consequently, optimal water flow (0.5 L/min) was determined through a full-scale fire test.

Perception survey analysis for legal support in case of legal disputes among firefighters (소방공무원의 법적 분쟁 시 법률지원을 위한 인식조사 분석)

  • Reem, Young-Jin;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.495-507
    • /
    • 2023
  • The purpose of this study is to identify the current status of legal disputes that occur while firefighters are performing their duties and to suggest efficient response measures. To investigate awareness of legal disputes, a survey was conducted on 3,500 firefighters, and the responses of 505 people who participated in the survey were analyzed. As a research method, frequency analysis and cross-analysis were conducted based on the demographic characteristics of the participants and a survey of firefighters' awareness of the law, and through this, basic statistics and status were analyzed. As a result of the analysis, it was found that firefighters feel a lot of burden, including time and material losses, as well as disadvantages and mental anxiety in the workplace when legal disputes occur while performing their duties. The need for an organizational response in the workplace as an efficient response to this was statistically confirmed. Therefore, based on the results of this study, we propose the permanent establishment and operation of a professional legal support team within each city/provincial fire department headquarters so that firefighters can concentrate on their duties free from legal disputes.

The Proposition of Domestic Sprinklers Installation Standard and the Fire Services Act (국내 스프링클러 설치기준과 소방관련 법에 관한 고찰)

  • Kim, Yong-Moon;Lee, Young-Jai
    • Journal of Korean Society of Disaster and Security
    • /
    • v.7 no.2
    • /
    • pp.17-24
    • /
    • 2014
  • Recently, many accidents occur frequently because sprinklers aren't installed or don't work right when there are outbreak of fire in houses and aggregate buildings. Therefore, they can result in damage for humans and loss of property. Sprinklers are the most appropriate which can extinguish buildings' fire in the initial stages. Through lack of legal system, in domestic cases, sprinklers cannot operate their inherent performance. Domestic standard simply classifies installation objects according to types of business and forms of buildings, also divides into uses and floors of buildings. Especially it only regulates that sprinklers must be installed every floors in particular fire buildings that have more than eleven floors. While it doesn't need to install sprinklers below ten floors, so we are threatened the safety. In this study, we derived causes and implications by analyzing concepts of sprinklers facilities, installation standards in domestic and foreign legal system, and recent cases that expanded damages in fire accidents because of weak point of installation and control standards. In domestic cases, as a result, government has to provide an institutional strategy and law that regulate duty to install sprinklers to all aggregate buildings regardless of floors in terms of new buildings. Also, if someone who has existing buildings wanted to install them, government would guarantee subsidy to encourage installation. In addition, government supervises fire-fighting activities when there are fire by compensating standards about regular inspection by a qualified technician, operation and maintenance of sprinklers as well as reinforcement of administrative criteria.

Development Considerations of Natural Disaster Command System for Public Officers through Analysis of Disaster Response Activities at On-Scene (풍수해 현장대응업무 분석을 통한 재난현장 일반직 공무원 대응편제 개발시 고려사항 연구)

  • We, Kum Sook;Jeong, An Young
    • Journal of Korean Society of Disaster and Security
    • /
    • v.6 no.1
    • /
    • pp.47-53
    • /
    • 2013
  • Standard Incident Command System in Korea is that Incident Command System for Emergency Rescue Operation, which is commanded only by Fire Fighting Agencies. However, in the event of a disaster such as the flood, storm, or landslide disaster, there are many disaster response activities performed by the General Public Officers at the disaster on-scene. Yet, there isn't an Natural Disaster Command System for the General Public Officers in Korea. Thus, we have studied the response activities needed cooperation among agencies and proposed some considerations of the Natural Disaster Command System for General Public Officers. The system will be useful to response and recover disaster rapidly, seamlessly, and cooperatively among General Public Officers and the related agencies.

Investigation Study of Information Improvement in Chemical Accident by Extraordinary Chemical Reaction (이상반응 화학사고 정보제공 개선 연구)

  • Kim, Sungbum;Lim, Myunghee;Park, Joongdon
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.2
    • /
    • pp.219-225
    • /
    • 2015
  • Hydrofluoric acid leakage accident was occurred on Dec. 2012 in Hube Global. That accident has bought many changes of response in national organizations. Chemical companies respond quickly even when small quantities leakage of chemicals and response agencies were put a lot of manpower and equipment in incident response. Incident response to the response activities of the agents is difficult if the accident substance was not identified. Unknown chemicals can be generated by the water for fire-fighting during the emergency response process. In this case, an additional information was needed for response of chemical accident to prevent of great damage. In this study, we investigated the improvement of chemical accident information by extraordinary chemical accident.

A Comparative Study on Korean Compulsory Multiple Prime Contract System (건설산업 제도개선을 위한 분할·분리 발주 제도의 선진화 방안 연구)

  • Kim, Sang-Bum;Cho, Ji-Hoon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.2
    • /
    • pp.184-193
    • /
    • 2013
  • Procurement System for Korean construction industry has mainly been controlled by the complicated regulatory system which has been recognized as unflexible and remotely separated from the global standard. This has been identified by many Korean construction experts as one of the main reasons that hamper the Korean construction industry becoming the global leader. One commonly discussed regulatory system is the compulsory multiple contracting system that has been enforced for a long time. According to the Korean governmental contracting law 68-3, all construction projects cannot be divided into separate contracting packages with a few exceptions. Exceptions stated in the law include construction activities related electrical, Information communication, fire-fighting, and cultural assets which all are governed by the separate laws/acts controlled by the different governmental bodies. This research is to closely investigate multiple prime contracting system that has been compulsory in Korean construction industry and to provide policy recommendations to these restrictions. Although, there has been a long history of this compulsory contracting system, this study attempted to provide objective analysis on current status of the system as well as global standard on the issue. This study suggests main considerations when considering different contracting system such as rights of owners, flexibilities of regulatory systems, and efficiencies of conducting a construction project. It is envisioned that recommendations from this study, if accepted by the regulatory bodies, would improve the Korean construction contraction system by making it more compatible with global standard. Moreover, these would help making the Korean industry more effective in terms of regulatory restrictions.