• 제목/요약/키워드: Fire-Resist Performance

검색결과 21건 처리시간 0.026초

화재가열을 받은 고강도 콘크리트를 충전한 CFT 기둥의 내화성능 평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Fire-Resist Performance of High-Strength Concrete Filled steel Tube Column at Fire)

  • 이형준;이태규;김영선;한희철;김규용;김무한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.193-197
    • /
    • 2008
  • Recently, it increases in use of CFT(Concrete filled steel tube, below CFT) that is an excellent internal force and deformation capacity because material and method are required to be diversification and High-Performance according to increase the super-high structure. And it is proposed to use high-strength Concrete Filled steel Tube Column. But it is difficult quantitative evaluation about fire-resist performance of CFT because steel tube bind concrete. Also, the case of high strength CFT is feared that spalling occur inside. Therefore, this study made CFT specimen that determine the factor(which is strength of concrete) and then CFT column was exposed to heating controlled as closely as possible the ISO-834 standard fire curve. Also, it tried to analyze internal temperature through nonlinear transient heat flow analysis.

  • PDF

재하 및 비재하 내화 실험을 통한 고강도콘크리트의 내화성능에 관한 실험적 연구 (A Experimental Study on the Fire Resistant Performance of the High Strength Concrete with Loading and Unloading test)

  • 김우재;김현배;김규용;김영선
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.61-64
    • /
    • 2009
  • Recently, the higher buildings are, the stronger concrete are used. Ultra high strength concrete have the possibility of spalling when a fire breaks out. so the fire-resistance performance is necessary to use the ultra high strength concrete on the high-rise building. On this study, the heating test for the concrete with loading/unloading is performed for ultra high strength concrete using nylon fiber. The heating test followed by ISO-834 heating curve on the real-size specimen and the strength of concrete are 60, 80, 100, 200 MPa.

  • PDF

옥내용 뿜칠내화피복재의 촉진내구성 시험방법 연구 (Development of Acceleration Duability Test Method for Fireproof Spray-Applocation)

  • 김대회;이건철;이세현
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.104-105
    • /
    • 2013
  • The buildings constructed with steel structure is coated with certified fire resistive material to resist from fire. Coating materials lose their initial performances as time passes, so they need some maintenance. Fireproof spray-application also loses its performance and this performance loss of thr fireproof spray-application is very important because fire resistance of buildings depends on fireproof spray-application. So this study is to develop Acceleration durability test method of Fireproof spray-application, and use the Certification of fire resistant coating system.

  • PDF

초고층 건축공사 고강도 콘크리트 골조의 내화 및 폭렬 방지성능 중요도 선정 (Decision of the priority of Fire Endurance and Spatting Prevention Efficiency in High Strength Concrete at High Rise Building Work)

  • 백대현;한민철;한천구
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2008년도 정기학술발표대회 논문집
    • /
    • pp.804-807
    • /
    • 2008
  • 최근 건축 구조물의 초고층화 대형화로 인해 고강도화 되는 콘크리트는 치밀한 조직으로 인해 화재시 폭렬에 취약하고, 내화성이 저하되는 문제점을 지니고 있다. 이로 인해 국내에서도 내화의 문제점을 인식하고 방안제도를 마련하고 있으며, 많은 연구진에 의해 고강도 콘크리트의 내화공법이 소개되고 있다. 이에 본 연구에서는 고강도 콘크리트의 내화공법 선정시 중요도를 관련 전문가의 설문조사를 기반으로 AHP 기법을 이용하여 분석하였다. 설문조사를 통한 분석 결과 상위 평가항목의 화재성능과 상시성능 중 내화공법 선정시에는 화재성능이 가장 중요시되는 것으로 나타났다. 화재성능에 대한 하위 항목에서는 인명보호가 중요한 요소로 산정되었고, 인명보호에 대한 하위 항목에서의 설문분석 결과 유해가스 발생억제가 중요한 요소로 산정되었다.

  • PDF

용접 불티 차단막 개발을 위한 섬유류의 적정 방염처리 방안 연구 (A Study on the Treatment of Suitable Flame Retardant to the Fibers for Welding Blanket Development)

  • 이근원;김관응;이두형
    • 한국화재소방학회논문지
    • /
    • 제16권3호
    • /
    • pp.48-55
    • /
    • 2002
  • 본 연구는 용접불티 차단막 개발을 위해 섬유류의 방염처리 후 화재성능 평가를 통해 적정한 방염 처리 방안을 제시하였다. 실험재료는 시중에서 유통되고 있는 섬유류이며, 방염처리는 난연제와 방화도료를 사용하였다. 화재성능 실험은 한국과 일본 기준에 따라 수행하였다. 실험결과 방염처리된 섬유류는 방염 및 난연성능이 충분하였으며, 그들의 난연등급은 A급에서 C급으로 나타났다. 최소산소지수는 방염제로 처리된 모든 시료가 국제기준을 만족하였다. 용접불티 차단막을 수평으로 설치하여 사용할 경우에는 작업대 높이에 관계없이 난연 A급에서 C급의 성능을 가진 제품을, 수직으로 설치할 경우 난연 C급 성능을 갖는 제품을 사용하는 것이 용접불티에 의한 화재확산을 예방할 수 있을 것으로 사료된다.

비재하 가열시험 및 Stub 시험체를 활용한 CFT기둥의 역학적 특성평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Mechanical Properties of CFT Column by Unstressed Test and Stub Specimen)

  • 이대희;이태규;이의배;김영선;김규용;김무한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.209-213
    • /
    • 2008
  • Recently, it increases in use of CFT(Concrete filled steel tube, below CFT) because material and method are required to be diversification and High-Performance according to increase the super-high structure. But, CFT column lose bearing capacity under fire because steel tube is exposed to outside. As a result, structure is collapsed and then it cause much damage. In case of the Europe, Japan and America, they have studied the fire-resistance performance of CFT under fire for a long time. However, it would have hardly studied it in domestic because it is much difficulty about experiment machine and cost. So it is needed base on fire-resist performance of CFT under fire. Therefore, this study dynamic specificity of stub column which made tester of stub column based on facts of strength and mixing fiber evaluated used heating and load testing machine. As a result, it is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with experiment according to the design high strength concrete.

  • PDF

옥내용 뿜칠내화피복재의 촉진내구성 조건 설정 연구 (Development of Acceleration Duability test condition for Fireproof Spray-Application.)

  • 김대회;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.170-171
    • /
    • 2014
  • The buildings constructed with steel structure is coated with certified fire resistive material to resist from fire. Coating materials lose their initial performances as time passes, so they need some maintenance. This study is covers standardization of the methods for assessing the durability of SFRM. In Korea, more than 90 percent of SFRM are used indoors. So This study is to decide proper test method through investigation and examination of effect factor to performance of fire-resistant structure and applicable test method.

  • PDF

옥내용 뿜칠내화피복재의 촉진내구성 조건 설정 연구(II) (Development of Acceleration Duability test condition for Fireproof Spray-Application(II).)

  • 김대회;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.109-110
    • /
    • 2014
  • The buildings constructed with steel structure is coated with certified fire resistive material to resist from fire. Coating materials lose their initial performances as time passes, so they need some maintenance. This study is covers standardization of the methods for assessing the durability of SFRM. In Korea, more than 90 percent of SFRM are used indoors. So This study is to decide proper test method through investigation and examination of effect factor to performance of fire-resistant structure and applicable test method.

  • PDF

무내화피복 CFT 공법의 내화성능 확보를 위한 실험적 연구 (An Experimental Study on the Ensuring the Fire Resistance Performance of Non-Refractory Coating CFT)

  • 이지환;한민철
    • 한국건축시공학회지
    • /
    • 제15권3호
    • /
    • pp.273-280
    • /
    • 2015
  • 본 연구는 3시간 내화성능을 만족할 수 있는 고성능 무내화피복 CFT 기둥 개발을 위한 연구로서, 고로슬래그 미분말 치환율에 따른 성능평가를 실시한 결과 고로슬래그 미분말 치환율이 증가함에 따라 내화성능이 개선되는 것을 확인 할 수 있었으며, 내화성능을 고려한 CFT 기둥용 100MPa 충전콘크리트의 고로슬래그 미분말 적정 사용량은 40%로 나타났다. 이에 따라 고로슬래그 미분말 40% 혼입 100MPa 충전콘크리트를 적용한 CFT 실물 시험체를 대상으로 재하하중별 내화시험을 실시한 결과 재하하중이 증가함에 따라 내화성능 발현시간이 감소하는 것으로 나타났으며, 재하하중 2,000kN에서는 240분 이상의 내화성능을 나타내었고, 3,000kN에서는 184분, 4,000kN에서는 120분의 내화성능을 나타내었다.

중인방을 포함한 목골조 경량벽체의 내화성능에 관한 연구 (A Study on the Fire Resistance Performance of Wood Framed Lightweight Wall which Including a Middle Lintel)

  • 여인환;조범연;민병렬;윤명오
    • 한국화재소방학회논문지
    • /
    • 제25권3호
    • /
    • pp.91-98
    • /
    • 2011
  • 이 연구는 전통 벽체 형식으로서 중인방을 포함한 목골조 경량벽체의 내화성능에 대한 것이다. 대상으로 한 경량벽체는 $38{\times}89$ mm($2"{\times}4"$) 목재를 골구로 하고 방회석고보드로 마감하는 형식의 비내력구조 이다. 벽체의 중간부에는 $150{\times}150$ mm 단면의 집성목 중인방을 설치하였다. 실험체는 단열재 유무 등에 따라 3가지 타입으로 제작하였다. 내화실험 결과 실험체-1, 2, 3 모두 90분 이상의 내화성능을 확보하는 것으로 나타났고, 각각 92분, 98분, 99분만에 중인방의 측면과 하부에서 불꽃이 발생하여 실험을 중단하였다. 가열면의 방화석고보드($12.5mm{\times}2$겹)는 약 45분간 내화성능을 유지하는 것으로 나타났고, 중인방의 연소는 일반적인 목재의 탄화속도와 유사한 거동을 보였다 벽체 내부의 목재스터드는 방화석고보드의 기여로 연소가 지연되는 동안 탈수가 일어나 고온에 노출된 이후에는 수분에 의한 온도상승 지연효과가 일어나지 않고 비교적 빠른 연소가 진행되는 것으로 나타났다.