• Title/Summary/Keyword: Fire-Flame detection

검색결과 80건 처리시간 0.019초

모션 벡터를 이용한 화염 검출 알고리즘 (Flame Dection Algorithm with Motion Vector)

  • 박장식;배종갑;최수영
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.135-138
    • /
    • 2008
  • Many Victims and property damage are caused in fires. In this paper, an flame detection algorithm is proposed to early alarm fires. The proposed flame detection algorithm is based on 2-stage decision strategy of video processing. The first decision is to check with color distribution of input vidoe. In the second, the candidated region is settled as fire region with activity. As a result of simulation, it is shown that the proposed algorithm is useful for fire recognition.

  • PDF

DSP Embedded Early Fire Detection Method Using IR Thermal Video

  • Kim, Won-Ho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제8권10호
    • /
    • pp.3475-3489
    • /
    • 2014
  • Here we present a simple flame detection method for an infrared (IR) thermal camera based real-time fire surveillance digital signal processor (DSP) system. Infrared thermal cameras are especially advantageous for unattended fire surveillance. All-weather monitoring is possible, regardless of illumination and climate conditions, and the data quantity to be processed is one-third that of color videos. Conventional IR camera-based fire detection methods used mainly pixel-based temporal correlation functions. In the temporal correlation function-based methods, temporal changes in pixel intensity generated by the irregular motion and spreading of the flame pixels are measured using correlation functions. The correlation values of non-flame regions are uniform, but the flame regions have irregular temporal correlation values. To satisfy the requirement of early detection, all fire detection techniques should be practically applied within a very short period of time. The conventional pixel-based correlation function is computationally intensive. In this paper, we propose an IR camera-based simple flame detection algorithm optimized with a compact embedded DSP system to achieve early detection. To reduce the computational load, block-based calculations are used to select the candidate flame region and measure the temporal motion of flames. These functions are used together to obtain the early flame detection algorithm. The proposed simple algorithm was tested to verify the required function and performance in real-time using IR test videos and a real-time DSP system. The findings indicated that the system detected the flames within 5 to 20 seconds, and had a correct flame detection ratio of 100% with an acceptable false detection ratio in video sequence level.

화재 조기 인식을 위한 화염 및 연기 검출 알고리즘 개발 (Development of Flame and Smoke Detection for Early Fire Recognition)

  • 박장식;김대경;최수영;이영성
    • 한국화재소방학회논문지
    • /
    • 제22권4호
    • /
    • pp.27-32
    • /
    • 2008
  • 본 논문에서는 화재의 조기 감지를 위하여 카메라 입력영상으로부터 화염과 연기를 검출하는 알고리즘을 제안한다. 화염과 연기는 특정 색분포를 가지며 지속적으로 형태가 변화하며 움직인다. 제안하는 화염검출 알고리즘은 화염의 색분포와 영상 프레임간의 변화를 측정하여 후보영역을 설정하고 화염의 움직임벡터를 계산하여 화염을 확정한다. 연기에 의하여 영상의 고주파수 성분이 감소하기 때문에 경계값의 변화는 연기의 중요한 특징이다. 연기검출은 색분포, 영상 프레임간의 변화 그리고 경계를 이용하여 후보영역을 설정하고 움직임 벡터를 계산하여 결정한다. 컴퓨터 시뮬레이션을 통하여 제안하는 알고리즘으로 화염과 연기를 검출할 수 있음을 보인다.

화재감지기를 사용한 발화점추적기반의 자동소방시스템 설계 및 구현 (Design and Implementation of the Automatic Fire Extinguishing System Based on the Ignition Point Tracking using the Flame Detecter)

  • 백승현;김영웅;오세일;박홍배
    • 대한임베디드공학회논문지
    • /
    • 제8권3호
    • /
    • pp.155-161
    • /
    • 2013
  • To reduce the personnel and material loss caused by fire, we propose the automatic fire extinguishing system based on the ignition point tracking using the flame detecter. This automatic fire extinguishing system is composed of the flame detecting system and the fire extinguishing system based on the water cannon. We study the method for the ignition point tracking and the automatic fire extinguishing using the water cannon and the flame detecter. The flame detecting system for the early fire detection and the ignition point tracking has to be satisfied the requirement of the detecting range and the flame detection time. So we study the signal process algorithm for an improvement of the flame detecting system.

Thermal Imaging Fire Detection Algorithm with Minimal False Detection

  • Jeong, Soo-Young;Kim, Won-Ho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권5호
    • /
    • pp.2156-2170
    • /
    • 2020
  • This paper presents a fire detection algorithm with a minimal false detection rate, intended for a thermal imaging surveillance environment, whose properties vary depending on temporal conditions of day or night and environmental changes. This algorithm was designed to minimize the false detection alarm rate while ensuring a high detection rate, as required in fire detection applications. It was necessary to reduce false fire detections due to non-flame elements occurring when existing fixed threshold-based fire detection methods were applied. To this end, adaptive flame thresholds that varied depending on the characteristics of input images, as well as the center of gravity of the heat-source and hot-source regions, were analyzed in an attempt to minimize such non-flame elements in the phase of selecting flame candidate blocks. Also, to remove any false detection elements caused by camera shaking, one of the most frequently raised issues at outdoor sites, preliminary decision thresholds were adaptively set to the motion pixel ratio of input images to maximize the accuracy of the preliminary decision. Finally, in addition to the preliminary decision results, the texture correlation and intensity of the flame candidate blocks were averaged for a specific period of time and tested for their conformity with the fire decision conditions before making the final decision. To verify the fire detection performance of the proposed algorithm, a total of ten test videos were subjected to computer simulation. As a result, the fire detection accuracy of the proposed algorithm was determined to be 94.24%, with minimum false detection, demonstrating its improved performance and practicality compared to previous fixed threshold-based algorithms.

조명과 환경 변화에 강건한 화염 검출 시스템 (A Flame-Detection System Robust to Lighting and Environments)

  • 박장식;김현태;박수창;손경식
    • 한국화재소방학회논문지
    • /
    • 제22권1호
    • /
    • pp.68-75
    • /
    • 2008
  • 본 논문은 화재를 조기에 검출하기 위하여 칼라 영상처리기법을 이용하여 주변 조명과 환경의 변화에 대하여 강건한 화염검출방법을 제안한다. 주변 조명과 화염의 RGB 색 분포 분석을 통하여 주변 조명과 화염을 구분할 수 있는 임계값을 설정하여 후보 영역을 검출한다. 화염이 발생 후 연속적으로 변화하기 때문에 화염 영역의 히스토그램 평균값의 차를 이용하여 화염 유사 영역을 제기한다. 검출된 영역이 화염임을 판단하기 위하여 영역 서술자인 밀집도를 계산하여 최종적으로 화염 여부를 판정한다. 컴퓨터 시뮬레이션을 통하여 제안한 방법이 화염을 보다 잘 검출하고 조명 등 주변 환경 변화에 강건함을 보인다.

도로터널용 방수노즐 위치제어형 자동소화설비의 화재감지성능실험 (Fire Detection Performance Experiment of the Water Jet Nozzle Position Control Type Automatic Fire Extinguishing Facility for Road Tunnels)

  • 김창용;공하성
    • 한국화재소방학회논문지
    • /
    • 제33권1호
    • /
    • pp.85-91
    • /
    • 2019
  • 이 연구는 불꽃파장 감지기술과 불꽃영상 감지기술을 융합한 도로터널용 자동소화설비의 화재감지성능을 평가하기 위한 실험이다. 화재감지성능을 향상시키기 위한 이 융합기술은 화재 시 화원의 위치를 파악하고, 노즐을 화원으로 향하여 화재가 발생한 장소에만 가압수를 방사함으로서 화재진압에 따른 수손피해를 줄이는 효과를 얻을 수 있었다. 도로터널의 화재 중 불꽃 및 연기가 선행되는 상황에서 각각 15 m, 20 m, 25 m, 30 m, 35 m 거리에 $70cm{\times}70cm$의 목표물을 두었을 때 화원의 위치를 파악하는지를 실험하였다. 실험결과 농연의 간섭으로 인해 자외선 및 삼파장적외선센서의 감지능력이 감쇠되는 결과를 확인하였다. 또한 농연으로 인해 불꽃이 가려진 경우 이미지센서가 농연을 감지하여 화재신호를 발신함을 확인하였다.

THE DEVELOPMENT OF A UV FLAME DETECTOR FOR THE AUTOMATIC FIRE SUPPRESSION SYSTEM FOR ENGINE COMPARTMENT FIRES

  • Lim, Sung-Mook;Jung, Ki-Chang;Kim, Eung-Sik;Kim, Hong
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.590-597
    • /
    • 1997
  • In this work, a new type of UV flame detection system was developed. In order to measure the performance of UV flame detector, various kinds of experiments was performed. The results show that the maximum response time of the UV flame detector is 0.2 seconds when the detection distance is one meter The advantages of this system include wide area, high speed response and high sensitivity. After testing the W flame detector in engine compartment it detected fire within 0.09 seconds and extinguished within 5 seconds. Hence, the UV flame detector can be applied in automatic fire suppression system for automobiles.

  • PDF

카메라 영상을 이용한 연기 및 화염의 조기 감지 최신 연구 동향 (Survey for Early Detection Techniques of Smoke and Flame using Camera Images)

  • 강성모;김종면
    • 한국컴퓨터정보학회논문지
    • /
    • 제16권4호
    • /
    • pp.43-52
    • /
    • 2011
  • 시대가 발전함에 따라 초고층 건물들이 도처에 세워지고 밀집되어 있다. 이러한 건물에 화재가 발생되면 발화지점 근처로 불이번지면서 대형화재의 위험성이 높아지고 이에 따른 인명 및 재산 피해가 증가한다. 따라서 이런 대형화재를 예방하고 피해를 최소화하기 위해서 화재를 미연에 감지하는 화재감지 기술에 대한 필요성이 높아지고 있다. 화재를 감지하기 위해 열감지기, 연기감지기, 불꽃감지기 등을 사용하는 방법이 있으나 본 논문에서는 감시 카메라에서 들어오는 입력 영상을 분석하여 화염과 연기를 초기에 감지하는 화재감지 시스템의 최근 연구 동향을 알아보고자 한다. 또한 이러한 화염과 연기 감지 알고리즘들을 다양한 형태의 동영상을 이용하여 구현 및 성능을 평가하였다.

Fast Video Fire Detection Using Luminous Smoke and Textured Flame Features

  • Ince, Ibrahim Furkan;Yildirim, Mustafa Eren;Salman, Yucel Batu;Ince, Omer Faruk;Lee, Geun-Hoo;Park, Jang-Sik
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권12호
    • /
    • pp.5485-5506
    • /
    • 2016
  • In this article, a video based fire detection framework for CCTV surveillancesystems is presented. Two novel features and a novel image type with their corresponding algorithmsareproposed for this purpose. One is for the slow-smoke detection and another one is for fast-smoke/flame detection. The basic idea is slow-smoke has a highly varying chrominance/luminance texture in long periods and fast-smoke/flame has a highly varying texture waiting at the same location for long consecutive periods. Experiments with a large number of smoke/flame and non-smoke/flame video sequences outputs promising results in terms of algorithmic accuracy and speed.