• Title/Summary/Keyword: Fire weight

Search Result 340, Processing Time 0.028 seconds

Fire Performance of Structural Lightweight Aggregate Concrete using PP fiber (PP섬유 혼입 고강도 경량골재콘크리트의 내화특성)

  • Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.797-800
    • /
    • 2006
  • Normally, Structural light-weight aggregate concrete(LWC) has been main used in high rise building with the object of wight loss. In spite of LWC have the advantage of light-weight, limit the use of strength restrictions by reason that explosive spalling in fire. Especially, LWC is occurred serious fire performance deterioration by explosive spalling. Thus, this study is concerned with fire performance of LWC for the purpose of using PP fibers prevent to explosive spalling. From the experimental test result, LWC is happened explosive spalling.

  • PDF

Improvement Proposal for the Fire Suppression Systems of Open Parking Lots (개방형주차장의 소방설비 개선 제안)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.1-8
    • /
    • 2016
  • In cars, the amount of combustibles, such as plastics, textiles, etc., have increased dramatically to improve the fuel efficiency of cars by reducing the gross vehicle weight according to the increases in an oil price and to reduce environmental problems. One or two cars were involved in a parking lot fire prior to the mid-2000 s. On the other hand, there were many parking lot fires where the entire car was destroyed due to increasing the use of plastics. In this study, the quantity of combustibles in a car was 316.2 kg over a total weight 1935 kg. This is 16.34% of total weight and 10 times greater than that three decades earlier. When a sprinkler is installed as a parking lot fire protection system as a substitute for water spray, the water discharge of the sprinkler must maintain the original density of water spray, $20lpm/m^2$. In addition, the use of a hose reel $CO_2$ system at pilotis parking lots must be prohibited because the hose reel $CO_2$ system has no adaptability for a car fire. Instead, this study proposes foam, dry powder, loaded stream systems be used in parking lot fire suppression systems.

Studies on Plywood Treated Fire-Retardant - III. The Fire-Retardant Degree of Monoammonium Phosphate Treated Plywood (합판(合板)의 내화처리(耐火處理)에 관(關)한 연구(硏究) - III. 제1인산(第一燐酸)암모늄처리합판(處理合板)의 내화도(耐火度))

  • Kim, Jong-Man
    • Journal of the Korean Wood Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.21-28
    • /
    • 1986
  • Plywood used for construction as a decorative inner material is inflammable and can fire accident, causing destruction of human life and property. In this study, 3.5mm Kapur plywoods were soaked in the 23% monoammonium phosphate solutions by cold soaking method 3, 6, 9hrs and hot-cold bath method for 3/3hrs, and redrying was carried out by press-drying at the platen temperature of 110, 130, 160, 180$^{\circ}C$, and then fire test was carried out to investigate burning point, flame exhausted length, frame spread length, back side carbonized area and weight loss. The results are as follows; 1. In cold soaking method for 3, 6, 9hrs. retentions of monoammonium phosphate were 0.377, 0.448, 0.498kg/(30cm)$^3$ respectively, and in hot-cold bath method for 3/3hrs, the retention was 1.331kg(30cm)$^3$ that exceeded the minimum retention 1.124kg/(30cm)$^3$. 2. Correlation coefficients among the variable were shown in table 2. From the table, it could be recognized that there were close negative correlations between the treatment and burning point, flame spread length, back side carbonized area, flame exhausted time and weight loss, and there was negative correlation between treating time and back side carbonized area, but there was positive correlation between platen temperature and burning point. 3. From table 3, it can be observed that there were highly significant differences for burning point, flame spread length, flame exhausted time, back side carhonized area, weight loss between treatments. And in 2-way interactions, there were also highly significant for burning point, flame spread length, flame exhausted time, weight loss between time x treatment. 4. It was observed that burning point, flame exhausted time, flame spread length, back side carbonized area, and weight loss in fire-retardant treated plywood were the best effects in fire-retardant treated plywood, water treated plywood and nontreated plywood. In conclusion, I can estimate that absorbed chemical contents by hot-cold bath method for 3/3hrs, have a lot of effects on fire-retardant factors such as burning point, flame spread length, flame exhausted time, backside carbonized area and weight loss, but platen temperatures have a little effects on the fire factors.

  • PDF

An Experimental Study on the Insulation Property of Light-Weight Foamed Concrete according to Foaming Agent Type (기포제 종류에 따른 경량기포콘크리트의 단열특성에 관한 실험적 연구)

  • Choi, Hun-Gug;Sun, Joung-Soo;Lee, Jung-Goo;Choi, Duck -Jin;Jeong, Ji-Yong;Kim, Jin-Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.27-30
    • /
    • 2007
  • Recently, use of light-weight panel is increasing in building. Styrofoam sandwich panel is inexpensive and it is excellent in insulation ability and constructability. But styrofoam of panel inside is low ignition point. Consequently, when panel is fired, it is occur in poisonous gas. On the other hand, light-weight foamed concrete is excellent in insulation ability, fire resistance due to inner pore. Properties of light-weight concrete is influenced by foaming agent type. Accordingly, this study investigate in insulation property of according to foaming agent type in order to using light-weight foamed concrete instead of styrofoam. As a results, Non-heating zone temperature of light-weight foamed concrete of using AP, FP are lower than light-weight foamed concrete of using AES. Light-weight foamed concrete of using AES, FP are satisfied with fire performance of two hours at foam ratio 50, 100. Light-weight foamed concrete of using AP is satisfied with fire performance of two hours at AP ratio 0.1, 0.15. Insulation property is better closed pore by made AP, FP than open pore by made AES.

  • PDF

Fire Resistance Performance of Load Bearing Hybrid Panel Infilled with Light-weight Formed Mortar (복합스터드에 경량기포모르터를 충전한 내력벽체의 내화성능 비교연구)

  • Park, Keum Sung;Bae, Kyu Woong;Kang, Hyun Sik;Lim, Seo Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.2
    • /
    • pp.109-116
    • /
    • 2007
  • The purpose of this paper is to evaluate the fire resistant performances of load-bearing wall using both composite and steel stud panel infilled with light-weight formed mortar under axial loading according to KS F 2257(1999). The minimum requirement of 2 hours fire resistant rating is needed for the residential and commercial buildings under the fire regulation of Korea. From test results, it is found that two types of specimen composed of the hybrid stud and steel stud panel filled with light-weight formed mortar fited in with the requirement of 2 hours fire resisting rate for the load-bearing wall. In the conclusions, the specimen with hybrid stud shows predominating fire-resistant performance on the adiabatic effects rather than that of the steel stud specimen.

Fire resistance of Light-weight Ceramic Board for Exterior Fire resistance Material (경량세라믹보드의 외장재 적용을 위한 화재성능평가)

  • Shin, Hyeon-Uk;Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.119-120
    • /
    • 2016
  • This study is about development of inorganic insulation material using by-product materials. The organic material is due to toxic gas emission, when a fire occurs. And it has lower water resistance. The inorganic material is heavy and worse thermal performance than organic materials. In this study, installed light weight ceramic insulation by concrete structure to evaluation fire resistance.

  • PDF

A Study on the Heat Release Characteristic of Household Items using LSC(Large Scale Cone Calorimeter) (LSC를 이용한 생활용품의 발열량 특성에 관한 연구)

  • Park, Ju Young;Baek, Chang Sun;Lee, Hae Pyeong;Hong, Yi Pyo
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.38-44
    • /
    • 2015
  • For this study, fire tests were performed targeting household items (Sofa, Drawer, Refrigerator, Washing machine) using a large cone calorimeter (Large Scale Cone Calorimeter, LSC). The data were obtained focusing on the fire characteristic of the data when the actual fire occurs. The study results showed the following mean HRR of the household items; drawer 2843 KW, sofa 2939 KW, washing machine 719 KW, refrigerator 2907 KW, and THR is found in sofa 2202 MJ, drawer 1559 MJ, refrigerator 1193 MJ, washing machine 627 MJ. From the result, it could be found that the sofa can cause significant heat generation when the fire occurs, and the flashover tendency was found relatively high in compartment fire. In addition, a weight of the four our household items was reduced sharply in a similar time (20min before and after) degree after ignition. The drawer and sofa which has a high heat release can be considered to speed up the fire spread as their weight decrease rapidly and showed relatively weak to the fire compared to the refrigerator and washing machine.

Study on the Fire Resistance of Light Weight Inorganic Polymer Concrete Panel Wall (Inorganic Polymer Concrete를 이용한 경량패널의 내화특성에 관한 실험적 연구)

  • Hwang, Ji-Soon;Kim, Woo-Jae;Kim, Dae-Hoi;Park, Dong-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.205-206
    • /
    • 2011
  • Inorganic Polymer Concrete, a type of Alkali activated cement and concrete, is known for various excellent performances, especially for better performance in the area of high temperature heat resistance(thermal characteristic) than portland cement concrete.In this study, light weight concrete panel was manufactured using this Inorganic Polymer Concrete and then evaluated for fire resistance with a small-scale heating furnace. Since the result showed excellent fire resistance, it is considered usable for manufacturing fire resistant concrete panel wall.

  • PDF

A Study on the Spontaneous Ignition Possibility of Shredded Waste Thermoplastic Elastomer (폐 열가소성 플라스틱 탄성체 분쇄물의 자연발화가능성에 관한 연구)

  • Park, Young Ju;Lee, Hae Pyeong;Goh, Kyoung Chun;Eom, Young Sup
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.1
    • /
    • pp.61-65
    • /
    • 2016
  • In this study, we considered the ignition possibility for the shredded thermoplastic elastomer at the fire ground loaded the waste TPE. The average moisture content of the TPE sample was almost 0.33 wt.% at $110^{\circ}C$ and the range of ignition point was $461.9{\sim}491.9^{\circ}C$ approximately. In addition, we analyzed the change of weight and calorie the TPE sample according to temperature variations using the TG-DTA analyzer. As a result, the weight loss occurred twice in $250{\sim}420^{\circ}C$ and $420{\sim}473^{\circ}C$, and we found the second weight loss temperature range was the ignition point of TPE. Also, we conducted the spontaneous ignition tests of TPE for the wet and dry samples and we confirmed that the possibility of spontaneous ignition of TPE was very low. The elapsed time and humidity had little influence on the spontaneous ignition of TPE in this experimental conditions. In conclusion, the spontaneous of the shredded waste TPE in this study.

Effects of Antimony Trioxide-containing Coating on Fire Retardancy of Wood-based Materials (Antimony Trioxide가 첨가(添加)된 내화도료(耐火塗料)의 도막(塗膜)이 목질(木質) 판상재료(板狀材料)의 내화성(耐火性)에 미치는 영향(影響))

  • Yun, Young-Ki;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.31-42
    • /
    • 1992
  • In this study, the relative effectiveness of antimony trioxide-containing coat on fire retardancy of plywood, particleboard and medium density fiberboard was investigated and compared through ISO ignition test and inclined panel test with non-coated ones. The results obtained were summarized as fallows: Any treated materials was not ignited in inclined panel test with 5 minutes, but only particleboard among treated ones burned in ISO ignition test with fairly delayed time. The weight loss rate of plywood decreased with the increased addition level of fire-retardant and the least values were obtained in particleboard and MDF at addition level of 7% and 5% respectively. Carbonized area of wood based materials decreased with the increased addition level of fire retardant. The temperatures of back in plywood, particleboard treated with fire-retard ant coat containing 7% $Sb_2O_3$ showed the lowest but MDF did not show any effectiveness with the increased addition level. The first flash time of plywood treated with fire retardant coat containing 9% $Sb_2O_3$, MDF and particleboard treated with fire retardant coat containing 7% $Sb_2O_3$ were 257sec., 286.4sec., 165.4sec. respectively.

  • PDF