• Title/Summary/Keyword: Fire smoke movement

Search Result 120, Processing Time 0.035 seconds

An Experimental and Analytical Studies on the Smoke Movement by Fire in High Rise Building (초고층 건축물의 화재 시 피난로 연기거동에 관한 실험 및 해석적 연구)

  • Shin, Yi-Chul;Kim, Soo-Young;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.11-14
    • /
    • 2008
  • A study on the fire and smoke behavior on experiments and analysis through STAR-CD in using about behavior analysis of the smoke. Kerosene of 3L in using on the experimental garden of 30cm in diameter same applies to heat release rate(HRR), buoyant force by Plume can be calculated at a rate of 1m/s. The result of experiment in average of velocity were 0.29m/s, and interpreted result were 0.28m/s. Besides, it is proved by interpreted that behavior of smoke movement can be not observed in the experiment. After smoke is Plume increased, ceiling-jet in formation being descend in smoke layer will be more thick smoke layer, and then vertical wall is collapsed in formation of wall-jet being descend. It is defined that smoke layer is more thick through descending course in wall-jet and ceiling-jet.

  • PDF

Smoke Movement Characteristics in the Ship's Indoor Spaces with Fire Size and Location (선박 실내공간에서 화재의 크기 및 위치에 따른 연기거동특성)

  • Han, Won-Hui;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.11 no.1 s.22
    • /
    • pp.53-59
    • /
    • 2005
  • It is very dongerous for ship‘s fire which occurs from navigating because of it will not be able to expect fire fighting from land so that handle with the oneself to control. Additionally, in the case of passenger ship is more serious for the reason of not only the property damage but also large life accident can be occurred continuously. When the fire occurs, the many smoke to occur simultaneously as well as the heat from combustion process and the poisonous smoke is brought the life damage as the death from suffocation The purpose of this study is to examine the smoke movement characteristics in the ship's indoor spaces with fire size and location An experimental study was carried out with two sized of fires and three typed of fire source locations. As the results, the smoke and heat diffusion characteristics Ms been showed the most quick rise curve in the case of comer type fire.

  • PDF

Smoke Movement Characteristics in the Ship's Indoor Spaces with Fire Size and Location (선박 실내공간에서 화재의 크기 및 위치에 따른 연기거동특성)

  • Han Won-Hui;Cho Dae-Hwan
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2005.05a
    • /
    • pp.167-173
    • /
    • 2005
  • It is very dangerous for ship‘s fire which occurs from navigating because of it will not be able to expect fire fighting from land so that handle with the oneself to control. Additionally, in the case of passenger ship is more serious for the reason of not only the properly damage but also large life accident can be occurred continuously. When the fire occurs, the many smoke to occur simultaneously as well as the heat from combustion process and the poisonous smoke is brought the life damage as the death from suffocation. The purpose of this study is to examine the smoke movement characteristics in the ship's indoor spaces with fire size and location An experimental study was carried out with two sized of fires and three typed of fire source locations. As the result of it, the smoke and heat diffusion characteristics has been showed the most quick rise curve in the case of comer type fire.

  • PDF

A Numerical Study of an Effect of the Aspect Ratio on Smoke Movement in funnel Fires (터널 화재시 종횡비에 따른 연기 거동에 관한 수치해석적 연구)

  • 이성룡;김충익;유홍선
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.1-6
    • /
    • 2004
  • In this study, numerical simulations were conducted to analyze an effect of the aspect ratio on smoke movement in tunnel fires using FDS 3.0. It was confirmed an application for tunnel fires in comparison with experimental results. The results showed relatively good agreement with experimental data within 1$0^{\circ}C$. Clear height of CFD by velocity distribution was about 3% higher than that of experiment. Smoke movement was confirmed by the analysis of temperature and velocity field. Results from variation of the aspect ratio showed good agreement with experimental data. The temperature at the vicinity of the fire source became lowly with the increase of the aspect ratio. But, decrease rate of the temperature was reduced by the decrease of the heat loss to the width direction.

A Study of Smoke Movement in an Enclosed Corridor. (밀폐된 복도 공간내의 연기 거동에 관한 연구)

  • 김성찬;유홍선;정진용;김충익
    • Fire Science and Engineering
    • /
    • v.13 no.2
    • /
    • pp.18-25
    • /
    • 1999
  • There are a lot of works for predicting smoke movement in a building experimentally and m numerically. It is Vel${\gamma}$ important to predict a smoke movement in a corridor which is c connected to adjacent spaces. A numerical analysis of smoke movement in an enclosed c corridor is perlormed by a field model. The used field model is develo야d with 3-D u unstructured meshes, PISO Algorithm and buoyant plume model. In this study, tern야~ature a and flow field, some important p하ameters such as smoke spread time, hot layer temperature, c ceiling jet velocity were compared with experimental data which were perlormed in Korea I Ins디tute of Machinery and Materials. And average velocity of ceiling jet by this study is c compared with Hinkley's formula. This paper shows a flow characteristic around the soffit a and average velocity of ceiling jet is i따luenced by geometry of corridor, heat output, and d distance from the fire source.

  • PDF

A Numerical Study of Smoke Movement for the Three Types of Atrium Fires using PISO Algorithm (PISO 알고리즘을 이용한 세 가지 형태의 아트리움 공간에서 화재 발생시 연기 거동에 대한 수치해석적 연구)

  • 정진용;유홍선;김성찬
    • Fire Science and Engineering
    • /
    • v.13 no.1
    • /
    • pp.21-30
    • /
    • 1999
  • In this paper, the smoke filling process for the three types of atrium spaces are simulated u using the two types of deterministic fire model; zone models and field models. The zone models u used are the FffiST, CFAST, and CCFM.VENTS m떠els develo야퍼 at the Building and Fire R Research Laboratories, NIST, USA and the NBTC one-room model of FIR.ECAIι delveloped at C CSffiO, Austr;외ia. The field models used are the fire field model developed by W. K Chow and a a self-developed Sl\1EP(Smoke Movement Estimating Program) based on computational fluid d dynamics the$\alpha$1es. The results pn려icted by the two approaches are very similar. The field model u using SIl\1PLE algorithm or SIl\1PLER algorithm requires much more computing time compared w with the use of Sl\1EP using PISO algorithm.

  • PDF

Study of Smoke Behavior and Differential Pressure in the Refuge Safety Area According to Damper Capacity of Smoke Control (제연댐퍼 송풍량에 따른 피난 안전 구역 차압 및 연기 거동 특성 연구)

  • Lee, Jae-Bin;Moon, Joo-Hyun;Lee, Seong-Hyuk;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2011
  • In this study, we calculated the smoke movement at the fire area of the refuge floor which has the refuge safety area in case of fire in the high rise building by using a computational fluid dynamics (CFD) code of FLUENT (ver. 13.0). The buoyancy plume was applied using the temperature and flow velocity which represent 10 MW heat release rate in order to describe the fire, and the smoke movement was predicted using a species conservation equation. The pressurization system of smoke control was adopted with smoke control damper in refuge safety area, at the result, it is confirmed that the damper capacity was enough to smoke control in which the flow rate of supply was applied 25 $m^3/s$ in the case of the door at fire area opened only, and 50 $m^3/s$ in the doors at the fire area and lobby both opened case. They were satisfied in NFSC 501-A. Even though the door of fire area closed, there were smoke leakages at the gap between the door and wall. In addition, the refugee could be isolated in the fire area when the door of fire area closed during smoke control in the case of using the high damper flow rate of supply, 50 $m^3/s$. Therefore the proper damper flow rate of supply are needed in order to prevent the damage of refugee and this study proposes the suitable condition of damper capacity according to refuge scenario.

A Study on the Design of Evacuation Route at Subway Station Using Simulation Analysis (Simulation 분석을 통한 지하철 역사 피난동선 설계 방안에 관한 연구)

  • Ham, Eun-Gu;Roh, Sam-Kew
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.1-7
    • /
    • 2010
  • Since subway fire disaster at Daegu, Korea smoke control system and passengers evacuation distance has been focused to reform. Existing smoke control facilities need to expand volume of ventilation capacity however, the complicate subway station structure can hardly react dispersion of smokes from massive subway cabin fire. Smoke flow at platform level move upward thought vertical stairway and passengers evacuation goes with same direction. The victims of evacuees from subway station fire mainly due to exposure of heat radiation and smoke. The study demonstration the effect of downward evacuates stairway system by separating evacuation route to smoke movement pass way including saving times of evacuation.

Numerical Study on the Smoke Movement and Evacuation in the Deeply Underground Subway Station Fire (대심도 지하역사에서의 화재시 연기거동과 피난에 대한 수치해석 연구)

  • Kim, Hong-Jin;Bae, Sung-Yong;Choi, Young-Ki;Hong, Gi-Bae;Ryou, Hong-Sun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1342-1347
    • /
    • 2011
  • Advantages of the deeply underground subway are underground space efficiency, high speed, decrease of noise and vibration. However, when fire occurs in the deeply underground subway station, large casualties are occurred like Daegu subway station fire due to the increase of evacuation distance. In this study, a numerical analysis was performed by using the fire and evacuation analysis program FDS+EVAC for smoke movement and evacuation in Beotigogae station among the deeply underground subway station. Heat release rate of carriage fire was set 10MW and the fire growth rate was ultrafast. As a result, the smoke move to the exit at 1085 second. The total evacuation time took 956 second.