• 제목/요약/키워드: Fire setting

검색결과 131건 처리시간 0.024초

방화(放火)화재 특성에 관한 실험적 연구 (A Experimental Study on the Arson Fire Characteristics)

  • 최진;권오승;강경식
    • 대한안전경영과학회지
    • /
    • 제10권2호
    • /
    • pp.1-13
    • /
    • 2008
  • This Study is to analyze the characteristics of arson fire under fire dynamics to protect people and property from arson fire which has been radically increased with the development of the Korean economy. Assembly and merchandise purposes such as theater, retail, and exhibition has been performed as the arson fire study. The experiment for this study is based on the analysis of the characteristic for its own combustion process and smoke spread when arson fire occurs. This study presents the analysis through comparing the condition of setting fire using liquid fuel such as thinner on purpose to the condition of setting fire naturally depending on each occupancy.

한국소방산업의 발전 방향에 관한 연구 (A Study on the Future Direction of Fire Industry in Korea)

  • 이정일;이성수
    • 한국방재학회 논문집
    • /
    • 제10권4호
    • /
    • pp.69-79
    • /
    • 2010
  • 소방산업은 화재와 재난으로부터 국민의 생명과 재산을 보호하는 중요한 역할을 담당하고 있다. 최근 들어 국내 소방산업은 일본, 미국 등 소방산업 선진국의 소방산업에 대하여는 품질 및 기술 경쟁에서 어려움에 부딪쳐 있고, 중국 등 소방산업 후진국에 대하여는 가격경쟁력 등이 취약하여 소방산업 발전에 어려움을 겪고 있어 이에 관한 연구가 필요한 실정이다. 본 연구의 목적은 소방산업계의 특성을 분석하여 발전 방향을 제시하는데 그 목적이 있다. 본 연구에서 제시된 발전방향은 앞으로의 소방산업 발전을 위한 목표설정, 육성방향을 통해 소방산업의 진흥 발전 실행에 실제 적용이 가능할 것이다.

철골구조물의 SPRAY 내화피복의 내화성능에 관한 실험적 연구

  • 정우택;오창희
    • 한국화재소방학회논문지
    • /
    • 제3권3호
    • /
    • pp.3-7
    • /
    • 1989
  • The aim of this study is to provide the basic data of spray setting method for the fireproof covering. For this purpose, the purpose, the behavior of different three kinds method which is the number of thimes, interval, finishing for a required performance. The result of the data analysis shows that it is better to spray setting method at a time and to finish by natural becomes to reduce a period and labor cost for works.

  • PDF

피난 모델을 이용한 대형할인매장의 화재시 피난에 관한 연구 (A Study on the Evacuation of People used the evacuation model on Fire in Shopping Mall)

  • 이수경;이상준
    • 한국화재소방학회논문지
    • /
    • 제14권4호
    • /
    • pp.17-22
    • /
    • 2000
  • 대형 할인 마트의 인명 안전 설계를 위해 대상 건물을 선정, 피난로의 피난시간을 계산해 보았다. 피난계산은 두 가지 방법으로 하였는데, 하나는 Computer 피난 모델인 EXODUS이고, 다른 하나는 일본의 피난계산법이다. 연구방법은 모델의 특성연구, 실제 대상 및 시나리오 선정, 그리고 피난 계산을 하였다. 연구결과, 대상 건물은 매우 높은 피난시간이 계산되어 설계된 피난로는 설정된 인구 이상의 용량을 피난시킬 수 없는 부적절한 것임을 알 수 있었다.

  • PDF

A Study on the Fire Safety of High-rise Apartments Based on Fire Door Switch and Automatic Fire Extinguishing System

  • Zhang, ZeChen;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • 제9권4호
    • /
    • pp.424-430
    • /
    • 2021
  • The purpose of this study is to analyse the characteristics and spreading laws of parameters such as fire smoke, concentration of CO, visibility, and temperature at fire scene in high-rise residential buildings under the different conditions of fire doors and automatic fire extinguishing systems. Using Pyrosim to simulate diverse fire scenes in a high-rise apartment with corridors, to analyze the changes in those parameters. The results show that when a fire occurs, closing the fire-fighting corridor will increase the smoke temperature and concentration of CO in the stairwell, and reduce the height and visibility of the smoke layer; the automatic fire extinguishing system effectively suppresses the increase in the temperature of the fire smoke and the sedimentation of the smoke layer. Reasonable setting and operation of the automatic fire extinguishing system could effectively inhibit the spread of fire. Although closing fire corridor can slow down the direct upward spread of smoke through the corridor, it will force the fire smoke into the stairwell, which will seriously affect evacuation through the stairs. Therefore, in order to reduce risks, it is forbidden to close the fire doors of the firefighting corridor and stacking combustible materials in the corridor, Also, intensifying inspections and ensuring the normal operation of the automatic fire extinguishing system are indispensable. Based on the research results, the significance of installing fire-fighting facilities in the construction of high-rise apartments was discussed and proved.

고강도를 적용한 1종 경량골재 콘크리트의 내화특성 (Fire Resistance Performance of High Strength-Light Weight Concrete)

  • 송훈;이종찬;이세현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.749-752
    • /
    • 2005
  • Normally, the degradation of concrete member exposed to fire is largely dependent on the fire scale and fire condition. With all ensuring the fire resistance structure as a method of setting the required cover thickness to fire, the RC is significantly affected from the standpoint of its structural stability that the compressive strength and elastic modulus is reduced by fire. Thus, this study is concerned with experimentally investigating fire resistance of high strength-light weight concrete. From the test result, high strength-light weight concrete is happened explosive spalling. The decrease of cross section caused by explosive spalling made sharp increasing gradient of inner temperature.

  • PDF

실물화재실험을 통한 공동주택의 화재안전성 연구 (The Real Scale Fire Test for Fire Safety in Apartment Housing)

  • 유용호;권오상;김흥열
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.57-65
    • /
    • 2009
  • 본 연구에서는 화재 시 많은 인명피해가 예상되는 공동 주택을 대상으로 단위공간별 화재 성상을 예측하기 위한 실물화재실험을 실시하였다. 실험 모델 주택을 구성하고 있는 내부 가연물을 선정한 후 각 단위 품목에 대한 화재특성 실험을 실시하였으며, 주방, 거실, 침실, 공부방 등 4종류의 단위 공간으로 구분하여 각각 실물화재실험을 실시하였다. 실험결과 침실의 경우 점화 후 약 5분이 경과되었을 때 플래쉬오버 상태에 이르게 되어 매우 급격한 성장을 보였으며, 최대 열방출율 약 7,433.3kW, 최대 CO 578.6ppm, 최대 $CO_2$ 1.25%, 내부 최대온도 $1,350^{\circ}C$로 측정되었다. 특히, 화재 발생 초기에 가연 공간에서 화재의 진화가 이루어지지 않으면 약 3분 내에 인체에 급격한 피해를 줄 수 있는 한계온도 이상으로 화재가 성장하기 때문에 신속한 초기 대응이 필요함을 확인하였으며, 장롱, 침구류 등 비교적 화재가 급속히 전이 될 수 있는 가연물량이 다수 배치되어 있는 침실에서 용도별 가연 공간 중 가장 위험도가 높은 것으로 측정되었다. 단위 가연물에서 발생되는 유독가스가 임계수준 이상으로 발생되어 이로 인해 인체에 심각한 피해를 줄 수 있을 것으로 판단된다. 이러한 실물화재실험에서 얻어낸 결과는 향후 화재확대 예측 시뮬레이션 결과와 비교함으로써 각 용도별 공간에서의 화재 확산 예측에 적용될 수 있을 것이다.

Fuzzy Measure를 이용한 화재감지기의 기본설계

  • 백동현;김기화
    • 한국화재소방학회논문지
    • /
    • 제10권3호
    • /
    • pp.19-28
    • /
    • 1996
  • 본 논문은 Fuzzy Measure를 이용한 화재감지기의 사고판정을 결정하는 방법을 제시한 것으로 Belief measere를 기본으로하여 Dempster의 결합 Rule을 사용하였다. 감지기에서의 화재 판정 결정은 화재(F), 비화재(N)의 2가지로 하였으며, 이를 판정하기 위해 현재 사용되고있는 열, 연기감지기에 대한 정정값에 대해 Fuzzy Rule을 적용하여 시뮬레이션 하였다. 그 결과 Fuzzy Rule의 수를 많이 적용할수록, 최종동작은 Bel(F)의 값을 높게 할수록 확실한 화재 판별이 가능함을 입증하였다.

  • PDF

자동차 방화사례의 분석 (Analysis of an Arson fire of Motor Vehicle)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제25권6호
    • /
    • pp.112-119
    • /
    • 2011
  • 이 논문에서는 보험금을 사취하기 위해 자신의 승용차에 방화한 사례에 대해 구체적으로 화재원인분석을 하였다. 이 자동차화재의 원인규명을 통해 (1) 화재현장의 바닥에 낙하된 부품이나 잔재물(residues) 등의 수거 시스템 구축, (2) 경찰서에서 국립과학수사연구원에 자동차화재의 원인규명 의뢰 시에 구체적인 화재현장정보의 제공 시스템의 구축, (3) 불탄 자동차에 방화혐의가 있을 때 소방서와 경찰서의 상호협조 체제의 유지, (4) 국립과학수사연구원의 자동차방화 화재의 원인규명 절차의 개선, (5) 화재원인 규명과 분석장비와의 상관성에 대한 인식 전환 등 현행 관행의 개선이나 제도개선이 필요함을 제안하였다.

헤모글로빈-일산화탄소 농도에 따른 연소형태 (Fire Patterns Based on the Hb-CO Concentration)

  • 최승복;오부열;최돈묵
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.373-377
    • /
    • 2011
  • 심하게 소손된 화재현장은 남아 있는 잔존물만으로 초기 화재의 유형을 판단하기 곤란할 때가 많다. 화재로 인해 사람이 사망하였을 경우 혈중 일산화탄소-헤모글로빈 농도는 생존 당시의 화재의 유형을 가늠할 수 있으며 촉진제를 사용한 급격한 화재의 경우 열기와 유독가스로 인해 재실자의 생존은 화재진행속도와 비례되어 체내 헤모글로빈 일산화탄소 농도는 낮았으며, 훈소와 같이 서서히 진행되는 연소의 경우 오랜 시간 호흡하면서 체내에 축적되는 일산화탄소 농도는 증가하였다. 이러한 인체의 헤모글로빈-일산화탄소 농도를 분석하면 생존 시 어떠한 형태의 화재에 노출되었는지 알 수 있었다.

  • PDF