• Title/Summary/Keyword: Fire sensor

Search Result 417, Processing Time 0.025 seconds

Implementation of the Arc Detection Device Using IR Sensor (IR 센서를 이용한 아크 발생 검출 장치 구현)

  • Hyun, Deuk-Chang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.4
    • /
    • pp.258-262
    • /
    • 2017
  • Recently energy consumption has been increasing because of advances in the industry, and electrical fires have accounted for 31.9% of all fire accidents. An electrical fire is caused by a short circuit, power surge, or poor contact. Safety devices for short circuits or power surges are currently mandatory and can actually detect problems, but arcing caused by contact failure is difficult to detect in advance. This study used an IR sensor to detect the heat concentration caused by the arc. The data from the low-resolution sensor was amplified as much as four times by interpolation to find the exact location of the heat source and were then investigated.

A study of the disaster management model based on USN (USN 기반 재난 관리 모델 연구)

  • Lee, Chang yeol;Kim, Tae hwan
    • Journal of the Society of Disaster Information
    • /
    • v.5 no.1
    • /
    • pp.122-139
    • /
    • 2009
  • USN Middleware plays roles of broker between sensors and applications. It collects sensor data, decides the situation and sends the result to the applications. It is not good to decide the situation from one sensor data, because it may error data or reflect small part of all. In this paper, we propose the disaster management model based on the concept 'group' and 'semantic information' from the sensing data. Group is the primary unit to decide the situation. It consists of several sensors which were installed in the same place and had the same pre-defined condition to act. For example, all fire sensors in the room simultaneously trigger the ring when the same pre-defined temperature is recorded. Then, the all fire sensors are included to the same one sensor group. All operations of the intelligent USN middleware are based on the 'group' unit. Disaster information is the result of the interpretation of the sensing data. based on the 'group', the disaster meaning is processed.

  • PDF

A Study on the Improvement of Fire Alarm System in Special Buildings Using Beacons in Edge Computing Environment (에지 컴퓨팅 환경에서 비콘을 활용한 특수건물 화재 경보 시스템 개선 방안 연구)

  • Lee, Tae Gyu;Choi, Kyeong Seo;Shin, Youn Soon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.11 no.7
    • /
    • pp.217-224
    • /
    • 2022
  • Today, with the development of technology and industry, fire accidents in special buildings are increasing as special buildings increase. However, despite the rapid development of information and communication technology, human casualties are steadily occurring due to the underdeveloped and ineffective indoor fire alarm system. In this study, we confirmed that the existing indoor fire alarm system using acoustic alarm could not deliver a sufficiently large alarm to the in-room personnel. To improve this, we designed and implemented a fire alarm system using edge computing and beacons. The proposed improved fire alarm system consists of terminal sensor nodes, edge nodes, a user application, and a server. The terminal sensor nodes collect indoor environment data and send it to the edge node, and the edge node monitors whether a fire occurs through the transmitted sensor value. In addition, the edge node continuously generate beacon signals to collect information of smart devices with user applications installed within the signal range, store them in a server database, and send application push-type fire alarms to all in-room personnel based on the collected user information. As a result of conducting a signal valid range measurement experiment in a university building with dense lecture rooms, it was confirmed that device information was normally collected within the beacon signal range of the edge node and a fire alarm was quickly sent to specific users. Through this, it was confirmed that the "blind spot problem of the alarm" was solved by flexibly collecting information of visitors that changes time to time and sending the alarm to a smart device very adjacent to the people. In addition, through the analysis of the experimental results, a plan to effectively apply the proposed fire alarm system according to the characteristics of the indoor space was proposed.

Design of Automatic Fire Prevention and Suppression System for Photovoltaic Connection Module (태양광 접속반의 자동 화재 예방 및 진압 시스템 설계)

  • Lee, Kang Won;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.3
    • /
    • pp.33-38
    • /
    • 2022
  • A solar power generation system uses a solar module that collects solar radiation energy, a connecting board that collects DC power generated from the solar module, and a diode to prevent reverse current from flowing from an inverter to the solar module. The existing photovoltaic connection module consists of only fuses and diodes for reverse polarity and overcurrent blocking, and does not have fire diagnosis, prevention, and suppression functions in the event of a fire. To solve this problem, this paper presents a method to monitor the internal state of the photovoltaic connection module using several sensors and to prevent and extinguish a fire using solenoid valves and fire extinguishing agents when a fire is detected. Through the experiment, it was confirmed that the proposed method normally suppresses the fire in event of a fire.

A study on Fire Hazard of Electric Radiant Heating Systems with Thermal Storage Using Off-peak Electricity (심야용 축열식 전기온풍기의 화재 위험성에 관한 연구)

  • Park, Min-Yeong;Mun, Yong-Su
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.8 no.1
    • /
    • pp.41-48
    • /
    • 2006
  • The purpose of this study is to identify the fire danger of the electric radiant heating system and check the way how to use it and the problems that could be possible through a actual case. We carry out an experiment to identify the possibility of the fire in the similar condition of the actual fire case. The results of this study are as follows. It is a possible condition to fire if the air blast of the electric radiant heating system is blocked by some combustible materials such as plastic bags continuously. A temperature sensor and a residual current device are necessary to disconnect the power source. It is also necessary to attach a notice in front of the electric radiant hearing system that shows users the fire danger to forbid the possible fire. Fires could be happened by internal defects of the electronic products. However, we can also find many external reasons to happen fires. Therefore, we need to check all reasons to make fires in the scene of a fire.

  • PDF

U-Bulguksa: Real-Time and Online Early Fire Detection Systems (U-불국사 : 실시간 온라인 화재조기감지시스템)

  • Joo, Jae-Hun;Yim, Jae-Geol
    • The Journal of Society for e-Business Studies
    • /
    • v.12 no.3
    • /
    • pp.75-93
    • /
    • 2007
  • This paper presents real-time online early fire warning systems developed for preserving cultural properties of Bulguksa which is a world heritage designated by UNESCO. The system is based on the ubiquitous sensor network employing 900MHz and 2.4GHz bands. In this paper, we analyze requirements that should be considered in building effective management systems of cultural heritages by using wireless sensor network. Finally, we introduce the architecture, sensor and network design, and software design of the fire warning systems which is an initial version of U-Bulguksa. The current version of systems has been operating in Bukguksa for a few months. U-Bukguksa project sponsored by National Information Society Agency is ultimately aimed at developing an integrated system of U-cultural heritage management and U-tourism. The former aims to conserve and manage intangible cultural properties by providing a variety of environmental information such as erosion, crack, and gradient as well as fire which are important causes of loss and damage in real-time and online. The latter refers to the intelligent tourism information and guidance systems allowing tourists to get the personalized content on cultural heritages and help guidance with mobile devices in Bulguksa.

  • PDF

Implementation of EO/IR Camera for Fire-fighting of Narrow Space (협소거주공간 진화를 위한 EO/IR카메라 구현)

  • Park, Hyun-Ju
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.628-629
    • /
    • 2018
  • Recently, residential spaces in urban areas have changed into multi - family residential spaces. There is a feature that smoke is charged when a fire occurs here. Also, the evacuation route and the direction of the outflow of smoke are the same, and the possibility of inhaling the smoke of the evacuees is very high. When fighting fire in a narrow residential space such as a dwelling in a downtown area, exploration is the most important. For this purpose, we implement EO / IR sensor which can be mounted on firefighter 's helmet and can be used for fire detection. By using the EO / IR operation test, we can derive the results that can be used for research and development of the fire search sensor.

  • PDF

A Study on Setting the Grade of Vertical Evacuation Rank to Introduce an USN-based Evacuation System into Super High-rise Apartment Housing's (초고층 공동주택의 USN기반 피난시스템 도입을 위한 수직적 피난위계 설정에 관한 연구)

  • Hong, Won-Hwa;Jeon, Gyu-Yeob;Choi, Jun-Ho
    • Journal of the Korean housing association
    • /
    • v.18 no.5
    • /
    • pp.133-141
    • /
    • 2007
  • The purpose of this study is to secure an evacuation time and to ensure safety by using an Ubiquitous Sensor Network computing when a fire breaks out at a super high-rise apartment housing. A super high-rise apartment housing that is a type of building to solve the problem of separation of the urban function and the phenomenon of hollowing out downtown has been on the increase, high-rise apartment housings occupying 52.7% of whole housings in 2005. However, if a fire breaks out, there would be serious damage since it accommodates many people and facilities as existence of vertical gigantism in the city. The architectural law in force has no clause on it which is universally applicable to general building, it is difficult to be applicable to a densely super high-rise apartment housing and there would be in danger of a resident's evacuation in the fire. Therefore, as a previous study to introduce an USN-based fire-warning facility and evacuation equipment, this study shows the improvement way after analyzing factors that are barriers to evacuaee's behavior of a super high-rise apartment housing and also shows establishment of the grade of vertical evacuation rank by SimuleX, one of the best computer simulation program.

A Study on Platform Development of Fire Detector applying IoT (화재감지기에 사물인터넷을 적용한 플랫폼 개발에 관한 연구)

  • Lee, Hae-Keon;Kwak, Dong-Kurl;Lee, Bong-Seob;Jung, Do-Young
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.1-3
    • /
    • 2018
  • When a fire is detected by a sensor of a fire detector, the fire is notified to the manager through the siren. However, if the manager is not indoors, prompt action may not be taken in the event of a fire. In this study, we would like to propose a platform system for fire prevention applying IoT to prevent problems that arise when building manager is absent. This paper presents the structure and operation principle of fire prevention platform system design using IoT, describes the overall system design through fire detector H/W design, micom S/W design and Android application development, and is expected to develop a system that can respond a little faster in case of fire.

  • PDF