• Title/Summary/Keyword: Fire safety management buildings

Search Result 93, Processing Time 0.018 seconds

A Study on the Fire Safety Plan for High-Rise Building Construction (초고층 건축물 건설공사 시 화재안전계획 수립에 관한 연구)

  • Ham, Eun-Gu;Jeong, Myeong-Jin;Lee, Myeong-Gu
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.11a
    • /
    • pp.59-66
    • /
    • 2012
  • Recently buildings are constructed in larger and higher scales and becoming more complex. Every country in the world is competing to build high-rise buildings. Korea also has and is constructing high-rise buildings, like the 123story Jamsil Lotte Super Tower. However from small to large scale buildings and on construction sites there still are fire safety accidents that occur continuously. Therefore to improve fire safety plan, examining the actual fire safety management and understanding fire risk analysis Using Fire Modeling through Computer Simulation. Fire safety management plan related fire safety cases were collected an dan analyzed for the study. Also hazard analysis of High rise Buildings under fire compared with existing fire law sand regulations.

  • PDF

High-rise buildings in the general direction of the Fire Safety Management Study (초고층 건축물 소방안전관리의 기본방향에 관한 연구)

  • Choe, Man-Cheol;Kim, Byeong-Seok
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.04a
    • /
    • pp.79-93
    • /
    • 2011
  • Unlike a general building high-rise buildings itself has a kind of risk. In this study, the risk of a number of high-rise buildings have fire safety management of the particular risks associated with looking for ways to minimize focused. Theoretical Study of the United States since the collapse of the WTC buildings, and be the center of the authentic country was. outside of the high-rise building fire safety and related issues, and measures were based on the theory of reference. Issues include voluntary arson. disaster management, building codes and fire regulations of the discrepancies, such as fire safety aspects are explained in terms of three kinds, and for it to take steps in the direction suggested an alternative for high-rise buildings. Although differences of opinion between departments will not be easy to fire and building regulations regarding conflicts of laws among other things, require immediate resolution, and high-rise buildings to create a standard for effective crisis management manual countermeasures will also be ensured.

  • PDF

A Study on the general direction of Fire-Fighting Safety management in high-rise buildings (초고층 건축물 소방안전관리의 기본방향에 관한 연구)

  • Choi, Man-Chul;Kim, Byung-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.67-75
    • /
    • 2011
  • Contrast a general building high rise buildings itself has a kind of risk. In this study, the risk of a number of high rise buildings have fire fighting safety management of the particular risks associated with looking for ways to minimize focused. Issues include self fire protection. disaster management, building code and fire code of the mismatch, such as fire protection facilities aspects are explained in terms of three kinds, and for it to take steps in the direction suggested an alternative for high rise buildings. Although differences of opinion between departments will not be easy to fire fighting and building codes regarding conflicts of codes above all require immediate resolution, and high rise buildings to create a standard for effective risk management manual countermeasures will also be ensured.

A Study on the Improvement of Fire Safety in high-rise Building Construction in Legal aspects (법규적 측면에서 고찰한 고층 건축물 공사현장 화재안전 확보방안)

  • Park, Chan-Seok;Jeong, Il-Kyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.21-32
    • /
    • 2015
  • High rising of the buildings offers a number of risk factors than ever before with regard to fire prevention. Especially in the construction site of high-rise buildings, people waste golden-time during the evacuation because temporary fire fighting facilities are not installed and transferred to a large fire because of fire suppression failure. In this study, the researcher derives the problems of fire protection in high-rise buildings construction sites and proposed the measures in such the legal aspects as fire building construction code and etc. There are the legal improvements such as orders of construction suspension in the problems of fire safety, appointing fire safety manager, temporary fire protection installation standards, enhancing penalty provisions regarding the use of fire, operating self fire brigade, confirming on-site after completing fire-protection facalities, establishment or strengthening special fire-protection investigations.

Problems and Reform Measures of Fire-Fighting Safety Management on the Skyscrapers (초고층 건축물 소방안전관리의 문제점과 개선방안)

  • Choi, Man-Chul;Lee, Dong-Hyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.4
    • /
    • pp.113-123
    • /
    • 2009
  • The number of high-rise buildings already constructed and/or being constructed is getting increased both domestically and internationally, for example, Lotte World 2 in Seoul and Taipei 101 in Taiwan, respectively. Maintenances of those skyscrapers, especially in fire-fighting safety, would be different from those of conventional buildings and are one of keen issues. In this study, the features of risks in aspects of fire-fighting safety for the buildings are investigated and the corresponding fire safety measures are proposed to prevent the disasters and to minimize the personal and property damages from it. The proposals include the specialization in self fire-fighting managements, the realization of self fire-fighting maintenance, the establishment of the integrated fire-fighting system, and the correction of inconsistencies in related laws on fire-fighting safety.

Improvement of Performance based wooden building National Fire Safety Codes (성능에 기반을 둔 목조건축물 화재안전기준 개선방안)

  • Oh, Taek-Hum;Park, Chan-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.2
    • /
    • pp.83-92
    • /
    • 2016
  • Because National Fire Safety Codes is mixed performance criteria and specification, and it defines the fire extinguish equipment type and standards that need to be installed in a building as one method. Therefore, to fully reflect the fire risk characteristics of the building, such as the wooden building there is a limit. In this study, suggested to the performance criteria drawn methodologies through fire load of wooden buildings studies, theory on performance and performance analysis to fire extinguish equipment of the wooden buildings is installed according to current fire safety codes.

A Study on the Fire Safety Plan for Building Construction (건축물 건설공사 시 화재안전계획 수립에 관한 연구)

  • Jeong, Myeong-Jin;Lee, Myeong-Gu;Ham, Eun-Gu
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.4
    • /
    • pp.31-37
    • /
    • 2012
  • Recently buildings are constructed in larger and higher scales and becoming more complex. However from small to large scale buildings and on construction sites there still are fire safety accidents that occur continuously. Therefore to improve fire safety plan, examining the actual fire safety management and understanding fire risk analysis Using Fire Modeling through Computer Simulation. On this study, the permissible evacuation times were estimated for smoke fall, temperature, CO concentration, viability, etc. Fire safety management plans for fire safety were suggested.

Improvement of Fire Safety Management Plan in Response to Hydrogen Chloride Leak (염화수소 누출에 따른 소방계획서 개선방안)

  • Boohyun Baek;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.3
    • /
    • pp.39-49
    • /
    • 2024
  • This study aims to propose an improvement of fire safety management plans for buildings, such as apartment complexes and schools, within a 10 km radius of industrial complexes. It utilizes an off-site consequence analysis program to reflect the toxic impact on national industrial complexes and surrounding areas. The ALOHA program was utilized to analyze the impact of toxicity due to a hydrogen chloride leak, a hazardous material. The results showed that the area with AEGL-2 and above ranged from 3.1 km to 10 km, the AEGL-3 area ranged from 1.9 km to 7.3 km. The ASET was measured to be between 3 and 24 minutes. Due to the impact of toxicity, it is necessary to prepare fire safety management plans for buildings, such as apartment complexes and schools that are within a 10 km radius from industrial complexes. These safety plans incorporate the hydrogen chloride risk assessment results, ASET, weather conditions, and coordination with the local community.

A Study on the Methods of Fire-Safety in Cultural Property Wooden Buildings (목조 문화재 건축물의 화재 방재를 위한 조사 연구)

  • Chang, Hyung-Soon;Cho, Won-Seok;Kim, Heung-Gee
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.10 no.4
    • /
    • pp.25-32
    • /
    • 2008
  • The prevention of disasters in cultural property is very important management and historical duties. The reason can't be measured values with monetary scale of our contemporary. Therefore, this paper was considered fire-safety as one of terrible threat-disasters about the wooden buildings. This research deal with 47 cases cultural property wooden building by whole investigation(field survey and interview) in Gangnung province. The most buildings have basic fire extinguisher; ABC powder. A few buildings are rarely installed fire extinguishing equipments; outdoor fire hydrant, heat sensor, ground sprinkler, CO2-hose-reel. But these state is very insufficient for the fire-safety in cultural property wooden buildings. Specially as particular attention in province, forest fire of regional characteristic have close relation with cultural property fire. The majority of factor against forest and building fire is to provide monitoring and security system; CCTV, Fence, Sensor, Alarm and paid guard man against incendiary. Ultimately it is necessary to construct comprehensive disaster prevention system with the organic cooperation such as National Emergency Management Agency, Cultural Heritage Administration, Forest Service, local government officials and regional citizen.

  • PDF

A Checklist and Manual Developed to Review Fire Safety Facilities' Compliance with Fire Safety Requirements for Apartment Buildings (공동주택 소방시설 적법성 검토를 위한 화재안전규정 체크리스트 및 매뉴얼 개발)

  • Jeong, Soo-jin;Park, Yoo-na;Kim, Jae-jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.6
    • /
    • pp.94-102
    • /
    • 2018
  • Recently, there is a growing need to review compliance with legal requirements to ensure fire safety as the number of fires caused by noncompliant fire safety facilities in high-rise buildings has increased. While there are a large number of apartment buildings in Korea, there is a lack of review on fire safety facilities' compliance with fire safety requirements. The reason for this lack of review despite apartment buildings causing deaths due to their structural features in the event of a fire, lies in the misinterpretation of legal provisions as the Building Act and the Fire Services Act are mixed up; a final inspection when fire safety facilities are unnecessarily installed or missing could result in significant losses in terms of finances and time. Therefore, this study developed a checklist that makes it possible to review mixed-up legal requirements for fire safety facilities simultaneously, and examined the importance and current level of each item through IPA (Importance Performance Analysis). Based on these results, this study intends to develop a manual that considers its applicability to construction practices and contribute to reducing construction companies' fire safety inspection risks.