• Title/Summary/Keyword: Fire safety design

Search Result 675, Processing Time 0.029 seconds

Enhancing fire resistance of steel bridges through composite action

  • Kodur, Venkatesh K.R.;Gil, Augusto
    • Steel and Composite Structures
    • /
    • v.43 no.3
    • /
    • pp.353-362
    • /
    • 2022
  • Bridge fire hazard has become a growing concern over the last decade due to the rapid increase of ground transportation of hazardous materials and resulting fire incidents. The lack of fire safety provisions in steel bridges can be a significant issue owing steel thermal properties that lead to fast degradation of steel properties at elevated temperatures. Alternatively, the development of composite action between steel girders and concrete decks can increase the fire resistance of steel bridges and meet fire safety requirements in some applications. This paper reviews the fire problem in steel bridges and the fire behavior of composite steel-concrete bridge girders. A numerical model is developed to trace the fire response of a typical bridge girder and is validated using measurements from fire tests. The selected bridge girder is composed by a hot rolled steel section strengthened with bearing stiffeners at midspan and supports. A concrete slab sitting on the top of the girder is connected to the slab through shear studs to provide full composite action. The validated numerical model was used to investigate the fire resistance of real scale bridge girders and the effect of the composite action under different scenarios (standard and hydrocarbon fires). Results showed that composite action can significantly increase the fire resistance of steel bridge girders. Besides, fire severity played an important role in the fire behavior of composite girders and both factors should be taken into consideration in the design of steel bridges for fire safety.

A Study on the Weighting of Fire Safety Attributes for Fire Risk Assessment in Historic Buildings - Focused on NakSansa- (역사적 건축물 화재위험성 평가를 위한 화재안전속성의 중요도분석 연구 - 낙산사를 중심으로 -)

  • Lee, Ji-Hee
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.189-196
    • /
    • 2012
  • Fire is one of the greatest threats to historical buildings not only to the building's occupants but also to the building's structure and contents. The purpose of this research is to evaluate fire risk in historical buildings in Korea through a series of survey and review. In this research, a multicriteria decision-making approach involving Analytical Hierarchy Process has been designed to determine a weighted index to identify factors and quantify fire risk. Fire risk ranking systems of historical building has been developed in some applications, for example, BOCA, WISCONSIN, FSES and HFRI. According to the such derived fire risk indexing, the Human Activity index showed the highest risk, followed by Historic Buildings, Fire Safety Systems, and then Natural Environmental Causes. Comparison of these factors indicates that the derived risk values differ from case to case. It is proposed that a performance-based design approach should consider the building & occupant characteristics, locations and historical significance, resulting in a more accurate and effective evaluation of fire risk.

A Study on Validation Methodology of Fire Retardant Performance for Cables in Nuclear Power Plants (원자력발전소 케이블 난연성능 검증 방법론 개선을 위한 연구)

  • Lee, Sang Kyu;Moon, Young Seob;Yoo, Seong Yeon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.140-144
    • /
    • 2017
  • Fire protection for nuclear power plants should be designed according to the concept of "Defense in Depth" to achieve the reactor safety shutdown. This concept focuses on fire prevention, fire suppression and safe shutdown. Fire prevention is the first line of "Defense in Depth" and the licensee should establish administrative measures to minimize the potential for fire to occur. Administrative measures should include procedures to control handling and use of combustibles. Electrical cables is the major contributor of fire loads in nuclear power plants, therefore electrical cables should be fire retardant. Electrical cables installed in nuclear power plants should pass the flame test in IEEE-383 standard in accordance with NUREG-0800, "Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants". To assure the fire retardant of electrical cables during design life, both aged and unaged cable specimens should be tested in accordance with IEEE-383. It can be generally thought that the flammability of electrical cables has been increased by wearing as time passed, however the results from fire retardant tests performed in U.S.A and Korea indicate the inconsistent tendency of aging and consequential decrease in flammability. In this study, it is expected that the effective methodology for validation of fire retardant performance would be identified through the review of the results from fire retardant tests.

Thermal-structural Coupled Field Analysis for Fire Safety Type Ball Valve (화재 안전용 볼밸브의 열·구조 연성해석)

  • Kim, Si-Pom;Lee, Joon-Ho;Lee, Kwon-Hee;Jeon, Rock-Won;Do, Tae-Wan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.28-32
    • /
    • 2011
  • The safety of transporting equipment in a cryogenic condition is one of important problems under the circumstances that the application weight of natural gas is gradually increasing. As a larger disaster may be generated by leakage of oil or gas from valves in case of fire occurrence of a ship, the present research applied a numerical analysis method on thermal stress distribution and deformation, etc. to the design of ball valves satisfying fire safety test's specification(API607) to prevent this. In addition, the present research progressed fire safety tests and compared the test result with numerical analysis results. The Max stress by parts was confirmed through thermal analysis of major parts to evaluate safety. The fire safety test was progressed according to the regulation of API607.

A Study on Revise the Rule of Safety Controllers of Hazardous Substances (위험물 안전관리 제도의 개선에 관한 연구)

  • Park, Kyong-Jin;Shin, Soo-Kyung;Lee, Bong-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.473-480
    • /
    • 2020
  • In this study, I analyzed problems of safety management system of hazardous substances and proposed improvement measures. By statistics of Korea National Fire Agency it shows that hazardous substances of not less than a designated quantity were 2,180 factorys, 24,732 handling places and 85,218 storing places in 2018. also It has been conformed that Fire accidents break out year after year in factory, etc. so In this study, I analyzed the safety controllers of hazardous substances of the present law and fire statistics. therefore I has been found out the problems that the first, safety controllers' status. the second, There is no laws related design, installation, installation supervision. the third, fire safety inspection. This study will be used a basic data for preventing of extensive hazazardous substances-related accident that is very difficult handling.

An experimental study on fire resistance of medical modular block

  • Kim, Hyung-Jun;Lee, Jae-Sung;Kim, Heung-Youl;Cho, Bong-Ho;Xi, Yunping;Kwon, Ki-Hyuck
    • Steel and Composite Structures
    • /
    • v.15 no.1
    • /
    • pp.103-130
    • /
    • 2013
  • Fire performance and fire safety of high-rise buildings have become major concerns after the disasters of World Trade Center in the U.S. in 2001 and Windsor tower in Spain in 2005. Performance based design (PBD) approaches have been considered as a better method for fire resistance design of structures because it is capable of incorporating test results of most recent fire resistance technologies. However, there is a difficulty to evaluate fireproof performance of large structures, which have multiple structural members such as columns, slabs, and walls. The difficulty is mainly due to the limitation in the testing equipment, such as size of furnace that can be used to carry out fire tests with existing criteria like ISO 834, BS 476, and KS F 2257. In the present research, a large scale calorie meter (10 MW) was used to conduct three full scale fire tests on medical modular blocks. Average fire load of 13.99 $kg/m^2$ was used in the first test. In the second test, the weighting coefficient of 3.5 (the fire load of 50 $kg/m^2$) was used to simulate the worst fire scenario. The flashover of the medical modular block occurred at 62 minutes in the first test and 12 minutes in the second test. The heat resistance capacity of the external wall, the temperatures and deformations of the structural members satisfied the requirements of fire resistance performance of 90 minutes burning period. The total heat loads and the heat values for each test are calculated by theoretical equations. The duration of burning was predicted. The predicted results were compared with the test results, and they agree quite well.

Simulation Study on the Fire Safety of AsanOeam Folk and JeonjuHanok Village

  • Park, Sun-gyu;Mishima, Nobuo;Kwon, Young-jin
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2016.05a
    • /
    • pp.259-260
    • /
    • 2016
  • Our research group, which was organized by the South Korean and Japanese researchers, have carried out research about natural disaster in our regional heritage villages derived from the concept of ICT(information communication technology)-based DPD(disaster prevention design). In this research, we performed simulation analysis on the fire safety diagnosis in Asan-Oeam folk and JeonjuHanok village for developing our research of ICT-based PBD. In order to do this, we used fire simulation program which was developed by BRI(Building Research Institute) of Japan. Based on the results of fire simulation of Asan-Oeam folk and JeonjuHanokvillage, we can demonstrated that the fire which broken out inregional heritage folk village will be easily expanded to adjacent houses, because the house which are built with wood structure.

  • PDF

Analysis of Fire Evacuation Behavior in a Primary School Environment

  • Lee, Chang-Seop;Kim, Hong;A. Kilpatrick;W. Fitzpatrick
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.492-504
    • /
    • 1997
  • The paper compares the statutory requirements for the design mid construction of primary schools in Korea and Scotland with respect to fire safety and examines the attitudes to, and the behavior in, evacuation scenarios of Primary school Pupils in both countries. The key behavioral issues examined are the effectiveness of fire safety training, the level of teacher dependency, the effect of spatial organization and gender differences both within and between Korea and Scotland.

  • PDF