Browse > Article
http://dx.doi.org/10.12989/scs.2022.43.3.353

Enhancing fire resistance of steel bridges through composite action  

Kodur, Venkatesh K.R. (Department of Civil and Environmental Engineering, Michigan State University)
Gil, Augusto (Department of Civil and Environmental Engineering, Michigan State University)
Publication Information
Steel and Composite Structures / v.43, no.3, 2022 , pp. 353-362 More about this Journal
Abstract
Bridge fire hazard has become a growing concern over the last decade due to the rapid increase of ground transportation of hazardous materials and resulting fire incidents. The lack of fire safety provisions in steel bridges can be a significant issue owing steel thermal properties that lead to fast degradation of steel properties at elevated temperatures. Alternatively, the development of composite action between steel girders and concrete decks can increase the fire resistance of steel bridges and meet fire safety requirements in some applications. This paper reviews the fire problem in steel bridges and the fire behavior of composite steel-concrete bridge girders. A numerical model is developed to trace the fire response of a typical bridge girder and is validated using measurements from fire tests. The selected bridge girder is composed by a hot rolled steel section strengthened with bearing stiffeners at midspan and supports. A concrete slab sitting on the top of the girder is connected to the slab through shear studs to provide full composite action. The validated numerical model was used to investigate the fire resistance of real scale bridge girders and the effect of the composite action under different scenarios (standard and hydrocarbon fires). Results showed that composite action can significantly increase the fire resistance of steel bridge girders. Besides, fire severity played an important role in the fire behavior of composite girders and both factors should be taken into consideration in the design of steel bridges for fire safety.
Keywords
advanced analysis; bridge girders; composite structures; fire resistance; numerical models;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 British Standard BS476-20 (1987), Fire Tests on Building Materials and Structures - Part 20: Method from Determination of the Fire Resistance of Elements of Construction (General Principles), British Standards Institution; Chiswick, London, UK.
2 Dwaikat, M. and Kodur, V. (2010), "Effect of location of restraint on fire response of steel beams", Fire Technology, 46(1), 109-128. https://doi.org/10.1007/s10694-009-0085-9.   DOI
3 Mirza, O. and Uy, B. (2009), "Behaviour of headed stud shear connectors for composite steel-concrete beams at elevated temperatures", J. Construct. Steel Res., 65(3), 662-674. https://doi.org/10.1016/j.jcsr.2008.03.008.   DOI
4 Vimonsatit, V., Tan, K.H. and Qian, Z.H. (2007), "Testing of plate girder web panel loaded in shear at elevated temperature", J. Struct. Eng., 133(6), 815-824. https://doi.org/10.1061/ASCE0733-94452007133:6815.   DOI
5 Kodur, V.K.R. and Naser, M. (2020), Structural Fire Engineering, McGraw Hill, New York, NY, USA.
6 Kodur, V.K.R. and Naser, M.Z. (2013), "Importance factor for design of bridges against fire hazard", Eng. Struct., 54, 207-220. https://doi.org/10.1016/j.engstruct.2013.03.048.   DOI
7 Eurocode 2 (2004), EN 1992-1-2: Design of Concrete Structures - Part 1-2: General Rules - Structural Fire Design, European Committee for Standardization; Brussels, Belgium.
8 ISO 834 (2014), Fire Resistance Tests - Elements of Building Construction, International Organization for Standardization; Geneva, Swerzerland.
9 Jankowiak, T. and Lodygowski, T. (2005), "Identification of parameters of concrete damage plasticity constitutive model", Found. Civil Environ. Eng., 6, 53-69.
10 Kodur, V.K.R. and Naser, M.Z. (2019), "Designing steel bridges for fire safety", J. Construct. Steel Res., 156, 46-53. https://doi.org/10.1016/j.jcsr.2019.01.020.   DOI
11 Kodur, V.K.R. and Naser, M.Z. (2021), "Fire hazard in transportation infrastructure: Review, assessment, and mitigation strategies", Front. Struct. Civil Eng., 15, 46-60. https://doi.org/10.1007/s11709-020-0676-6.   DOI
12 Kodur, V.K.R., Aziz, E.M. and Naser, M.Z. (2017), "Strategies for enhancing fire performance of steel bridges", Eng. Struct., 131, 446-458. https://doi.org/10.1016/j.engstruct.2016.10.040.   DOI
13 ASCE 29 (2005), Standard Calculation Methods for Structural Fire Protection, American Society of Civil Engineers, Reston, VA, USA.
14 Mendes, P.A., Valente, J.C. and Branco, F.A. (2000), "Simulation of ship fire under Vasco da Gama Bridge", Struct. J., 97(2), 285-290.
15 NFPA 502 (2017), Standard fo Road Tunnels, Bridges, and Other Limited Access Highways, National Fire Protection Association; Quincy, Massachusetts, USA.
16 Paya-Zaforteza, I. and Garlock, M.E.M. (2012), "A numerical investigation on the fire response of a steel girder bridge", J. Construct. Steel Res., 75, 93-103. https://doi.org/10.1016/j.jcsr.2012.03.012.   DOI
17 Wainman, D.E. and Kirby, B.R. (1987), "Compendium of UK standard fire test data for unprotected structural steel-2", British Steel Technical and Sweden Laboratories, Rotterdam, Netherlands.https://www.steelconstruction.info/images/c/ce/Co mpendium_UK2.pdf.
18 Zhang, G., Kodur, V.K. R., Yao, W. and Huang, Q. (2019), "Behavior of composite box bridge girders under localized fire exposure conditions", Struct. Eng. Mech., 69(2), 193-204. https://doi.org/10.12989/sem.2019.69.2.193.   DOI
19 Kodur, V.K.R., Aziz, E. and Dwaikat, M. (2013), "Evaluating fire resistance of steel girders in bridges", J. Bridge Eng., 18(7), 633-643. https://doi.org/10.1061/(asce)be.1943-5592.0000412.   DOI
20 AISC (2017), Steel Construction Manual, American Institute of Steel Construction. Chicago, IL, USA.
21 AASHTO (2009), LRFD Bridge Design Specifications, American Association of State Highway and Transportation Officials, Washington, DC, USA.
22 ACI 216 (2014), Code Requirements for Determining Fire Resistance of Concrete and Masonry Construction Assemblies, American Concrete Institute; Farmington Hills, MI, USA.
23 Choe, L., Ramesh, S., Dai, X., Hoehler, M., Bundy, M., Bryant, R., Story, B., Chakalis, A. and Chernovsky, A. (2021), "Fire Resilience of a Steel-Concrete Composite Floor System: Full-Scale Experimental Evaluation for U.S. Prescriptive Approach with a 2-Hour Fire-Resistance Rating (Test #1)", NIST Technical Note 2165. https://doi.org/10.6028/NIST.TN.2165   DOI
24 ASTM E1529 (2004), Standard Test Methods for Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and Assemblies, ASTM International; West Conshohocken, PA, USA.
25 Aziz, E.M., Kodur, V.K.R., Glassman, J.D. and Moreyra Garlock, M.E. (2014), "Behavior of steel bridge girders under fire conditions", J. Construct. Steel Res., 106, 11-22. https://doi.org/10.1016/j.jcsr.2014.12.001.   DOI
26 Bletzacker, R.W. (1966), "Fire resistance of protected steel beam floor and roof assemblies as affected by structural restraint", Symposium on Fire Test Methods-Restraint & Smoke, Atlantic City, NJ, USA.
27 Classen, M. (2018), "Limitations on the use of partial shear connection in composite beams with steel T-sections and uniformly spaced rib shear connectors", J. Construct. Steel Res., 142, 99-112. https://doi.org/10.1016/j.jcsr.2017.11.023.   DOI
28 Davidson, M.T., Asce, A.M., Harik, I.E., Asce, M. and Davis, D. B. (2013), "Fire impact and passive fire protection of infrastructure: State of the art", J. Perform. Construct. Facilities, 27(2), 135-143. https://doi.org/10.1061/(ASCE)CF.1943-5509.0000295.   DOI
29 Eurocode 3 (2005), EN 1993-1-2: Design of Steel Structures - Part 1-2: General Rules - Structural Fire Design, European Committee for Standardization; Brussels, Belgium.
30 Eurocode 1 (2002), EN 1991-1-2: Actions on Structures - Part 1-2: General Actions - Actions on Structures Exposed to Fire, European Committee for Standardization; Brussels, Belgium.
31 Dotreppe, J.C., Majkut, S. and Franssen, J.M. (2011), "Failure of a tied-arch bridge submitted to a severe localized fire", IABSE Symposium Report, 90(7), 15-22. https://doi.org/10.2749/222137805796270973   DOI
32 Eurocode 4 (2005), EN 1994-1-2: Design of Composite Structures - Part 1-2: General Rules - Structural Fire Design, European Committee for Standardization, Brussels, Belgium.
33 Fike, R. and Kodur, V.K.R. (2011), "Enhancing the fire resistance of composite floor assemblies through the use of steel fiber reinforced concrete", Eng. Struct., 33, 287-2878. https://doi.org/10.1016/j.engstruct.2011.06.011.   DOI
34 Hu, J., Usmani, A., Sanad, A. and Carvel, R. (2018), "Fire resistance of composite steel & concrete highway bridges", J. Construct. Steel Res., 148, 707-719. https://doi.org/10.1016/j.jcsr.2018.06.021.   DOI
35 ASTM E119 (2018), Standard Test Methods for Fire Tests of Building Construction and Materials, ASTM International; West Conshohocken, PA, USA.