• Title/Summary/Keyword: Fire response system

Search Result 253, Processing Time 0.025 seconds

Development of U-Building Fire Safety Management System (U-건물 화재안전관리 시스템 개발)

  • Kim, Jong-Hoon
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.74-80
    • /
    • 2016
  • Ubiquitous computer technology (U technology) is continually, and the trend is moving towards the miniaturization of devices, cost reduction, performance enhancement, and intelligence. It is important to improve fire safety system by the application of advanced IT technologies. In this study, a vulnerable point in fire safety was selected for improvement by U technology. The structure of the whole system and a unit system was were designed. This system is divided into 5 parts: the U-fire protection facility management system, the U-fire safety information system, the U-fire safety education system, the U-fire response system, and the U-wide area fire safety management system. The prototype system was constructed in a real building to confirm the applicability of the system.

A Study on the Development of Emergency Response Guidance in Case of Passenger Ship Fire (여객선 화재발생 시 대응가이던스 개발에 관한 연구)

  • Kim, Byeol;Hwang, Kwang-Il;Jeong, Eun-Seok;Moon, Serng-Bae
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.05a
    • /
    • pp.36-37
    • /
    • 2018
  • This study is about the development of emergency response guidance according to the fire safety index in the fire safety module, which is one of the on-board remote monitoring system. In this paper divided the zones based on the location of the fire sensor for passenger ship which is one of the service passenger ships and developed on the emergency response guidance by the identified zones.

  • PDF

Forest Fire Response System Using Thermal Imaging Camera (열화상카메라를 이용한 산불 화재 대응시스템 연구)

  • Yoon, Won-Sub;Kim, Yeon-Kyu;Kim, Seung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.927-935
    • /
    • 2021
  • This study conducted a study to improve the problems of the existing fire sensor system. In the case of the existing system, it took more than 3 minutes to detect a fire even at a short distance, making it difficult to extinguish the initial fire. In order to improve these problems, in this study, a fire detection system using an infrared thermal imaging camera was studied. The infrared image-based fire detection system is relatively wide and can detect fire over a long distance, so it has the advantage of being applicable to many fire detection systems. As a result of conducting a field test using the fire detection system, a fire that occurred about 2 km ahead was detected within about 10 seconds. Since the fire detection function of this system can detect within 10 seconds from a distance of about 2 km, it was applicable to forest fires that occur frequently in spring and autumn.

A Study on the Improvement of Safety Management by Analyzing the Current Status and Response System of Forest Fire Accidents (산불사고 현황과 대응체계 분석을 통한 안전관리 개선방안 연구)

  • Jeong, Kyung-ok;Kim, Dae-jin
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.457-469
    • /
    • 2022
  • Purpose: The purpose of this study is to present the direction of improvement of safety management by reviewing the current status of forest fire accidents that are becoming larger throughout the year and the problems of the response system. Method: Domestic and foreign literature survey and statistics of recent forest fire accidents by Statistics Korea investigated and analyzed the cause, number of damage, and suggested ways to improve forest fire safety management through domestic and foreign forest fire response systems. Result: Through the analysis of the causes of recent wildfires and overseas response cases, measures to improve the safety management of wildfires in terms of hardware, software, and humanware were derived. Conclusion: The plan to improve forest fire safety management was classified into three main categories and presented, and it should be embodied through further related research.

A Method on a Proper Time Evaluation for Railway Emergency Response Staffs using the Therblig Analysis (Therblig 기법을 활용한 철도비상대응직원의 적정 비상대응조치 시간 도출 방안)

  • Park, Min-Kyu;Kim, Si-Gon;Sim, Young-Rok
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.689-695
    • /
    • 2007
  • This Paper introduced a proper time evaluation for railway emergency response staffs using the Therblig Analysis. We defines what Activities the emergency response staffs should take when the fire occurs on the railway. This has been possible through the development of the scenario that is focused on the fire accident and it also has been driven to minimize the spread and damage of the accident. Gilbreth's Therblig Analysis has been used here to derive the reasonable time that would take for the emergency response staffs to respond to the fire accident on the railway system. We developed Emergency Response Scenario against Accidents and defined the Activity of the main Action for Emergency Response staffs.

  • PDF

A Study on the Response Characteristics of Fire Detector by Full-scale Experiment of Fire Phenomena in the Row House (주택 실물화재실험에 의한 화재감지기 응답특성에 관한 연구)

  • SaKong, Seong-Ho;Kim, Shi-Kuk;Lee, Chun-Ha;Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.67-72
    • /
    • 2009
  • This paper is for response feature of fire detectors not only to analysis response feature of fire detector, but also to observe flame spread of inside-building and fire enlargement by using the row house which is supposed to be broken up. Many kinds of popular detectors such as heat type detector(differential type, fixed temperature type, Analogue type)and smoke type(light scattered type, Analogue type, single alarm type) were installed in the house in order to check for the change of temperature by installing of thermocouples. As a result, smoke detectors are better than heat detectors when it comes to making effective fire-detect system in the row house.

A Study on Response Characteristics of ionization Smoke Detector Influenced by Air Stream (이온화식 연기감지기의 기류응답특성 연구)

  • 이복영;정길순;이병곤
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.6-9
    • /
    • 2003
  • Recently, forced ventilating air conditioning system has been widely used in modern buildings. However, It is obvious that this kind of system may affect on the response of fire detectors at real fire incidents, especially, on the ionization smoke detector, which is critically influenced by air stream. Therefore we studied to verify the response characteristics of air stream by ionization smoke detector for the design of facilities in practice. In this study, experiments were executed to examine the correlation between air velocity and the ionization detector's responses with var-ious air velocity and smoke densities in the simulated test room. As a result of experiments, ionization detector's operating time is in reverse proportion to air velocity. And the detector shows more sensitive reaction when the velocity of smoke stream increase over 60 cm/s. In addition, it was shown that ionization smoke detector is more sensitive to smoldering fires in paper than that in petro-chemicals.

Implementation of Monitoring and Control System for Fire Engine Pump using the AJAX (AJAX를 이용한 소방엔진펌프의 모니터링과 제어 시스템 구현)

  • Yang, Oh;Lee, Heon-Guk
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.3
    • /
    • pp.40-45
    • /
    • 2016
  • In this paper, the fire engine pump is controlled and monitored by the AJAX (Asynchronous Javascript and Xml) in the web server. The embedded system with built-in system having a processor and a memory of high performance occurs many problems in transmitting the large amount of data in real time through the web server. The AJAX is different from HTML (Hyper Text Makeup Language) with java script technology and can make RIA (Rich Internet Application). It process the necessary data by using asynchronous and it take advantage of usefulness, accessibility, a fast response time. Using AJAX can build up web server with real time and monitoring that fire engine pump status, check processing pump memory in the event of fire, also remotely monitors can do. The web server system can control the fire engine pump as like the black box. The experimental results show the effectiveness and commercialize possibility.

A Study on The Awareness of Fire-Fighting Officer for Strengthening Capabilities of Disaster Response System (재난현장 대응체계 역량강화를 위한 소방공무원 의식조사 연구)

  • Woo, Jaebong;Shin, Hojoon;Baek, Minho
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.276-281
    • /
    • 2013
  • This thesis grasped problems by examining the current status of disaster response system repeated during the disaster according to the changes of social environment and suggested current status of disaster response system and developmental measures through the investigation of the awareness of fire-fighting officer. On disaster site, close cooperation system of disaster safety measure headquarter and urgent rescue controlling association must be formed and range and time of the action must be accurately improved so as not to cause duplication of rights for orders. Also, systematic education and training system must be established so as to strengthen disaster site reaction capability and manpower and equipment for it must be increased. Finally, detailed measures for improving initial reaction capability during the disaster, such as tactic development, reaction plan establishment, etc, are requested.

A Study on the Improvement Plan for the Operation of National Fire Mobilization (전국 소방력 동원령 운영 개선방안에 대한 연구)

  • Lee, Chang Mok;Lee, Jong Ho;Chi, Jun Keun
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.3
    • /
    • pp.71-78
    • /
    • 2022
  • The purpose of this study is to improve the National Fire Mobilization Plan. This plan is a national-level comprehensive response system aimed to compensate for scarce firefighting resources and minimize damage from large-scale disasters that exceed the response limits of city and province firefighting forces. As such, relevant literature and domestic and foreign firefighting mobilization standards were reviewed, and simulations of firefighting mobilization were performed using the QGIS program to compare and analyze cases. Results showed that, as opposed to the current method of issuing mobilization orders by dividing resources according to city and province, recognizing the entire country as a single entity and prioritizing the mobilization of adjacent firefighting resources is more effective in terms of minimizing time and distance and more quickly securing resources. Regarding national firefighting mobilization, recognizing the country's firefighting resources as a whole will allow adjacent firefighting resources to be mobilized with priority. However, the mobilization-related limits of each region need to be set to respond to local disasters. Once the scale of mobilization is determined, a system that can quickly calculate how to mobilize firefighting resources based on location and distance can be established. Additionally, it is necessary to create an integrated management system so the central government can directly organize and mobilize local firefighting resources.