• Title/Summary/Keyword: Fire protection system management

Search Result 137, Processing Time 0.023 seconds

A Study on Efficient Improvement Ways of Fire Protection Management System (방화관리제도의 효율적 개선방안에 관한 연구)

  • Kook, Hyeong-Ho;Jo, Dae-Ho;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.115-127
    • /
    • 2008
  • Fire protection management system has been introduced to prevent structure fire since establishment of Fire Prevention Act. Nevertheless, Damage by fires is continue. The main purpose of this study is to discuss approaches to improve fire protection management system into the fire prevention properties. Now fire protection management system has lots of the problems in managerial and systematical aspects. To improve these a unified fire protection management system must be establish by suggests revision of a unified Fire Prevention Act and foundation of Fire Prevention Institution, reform educational system for the fire safety directors would be essential to includes environment improvement, enhancement of certification requirements and education, a standardized computational management system of the fire protection properties must be build for efficient fire protection operations.

A Study on the Management Plan of Fire Protection System Utilizing Urban Spatial Information (공간정보를 활용한 소방시설의 관리방안 연구)

  • Bang, Changhoon
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.98-104
    • /
    • 2019
  • This study examined the efficient management of a fire protection system using spatial information, and basic data for the development of related firefighting industry were obtained. To overcome the problems of malfunction and management failure, which are the major issues of fire protection system management, this study analyzed the related laws and regulations on building spatial information of a fire protection system to introduce spatial information to the fire protection system field. For efficient management of the fire protection system, it is necessary to revise the related laws of the fire protection system, such as protection system-related laws including space information technology, and maintain the standardization, effectiveness, and consistency of fire protection system spatial information.

Development of Performance Index for Ubiquitous Building Fire Safety System - Focused on Sprinkler System - (유비쿼터스 건물 화재안전시스템을 위한 성능지수 개발 - 스프링클러 시스템을 중심으로 -)

  • Kim, Jong-Hoon;Roh, Sam-Kew
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.23-30
    • /
    • 2009
  • For managing fire safety system in building by ubiquitous management system, the index system to express the performance level of fire protection system is demanded. If some component formed fire protection system such as sprinkler water supply system is breakdown, that will fall down the performance of fire protection capacity. Consequently, it will affects the level of fire safety of building management and energy response. Consequently, Building fire protection system could give performance level of fire protection condition and the level of fire safety in building. It will also contribute to the development of wide area fire safety management. This development of index system has been developed as a part of the development project of Ubiquitous building fire management system.

An Exploratory Study on 3D-based Building Information Management for Multi-User Fire Protection System

  • Kim, Dahee;Cha, Heesung
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.1162-1169
    • /
    • 2022
  • As buildings become more and more complicated, the importance of developing and managing facility management information is increasing. In a building fire situation, various information is generated and needed to be quickly shared among participants. However, the current fire response system fails to monitor the relevant information in a real time basis. This study aims to develop a system prototype for fire protection management which can quickly and accurately manage and effectively deliver the pertinent information to the target participants. The research contributes to the efficiency of fire protection endeavors by interpreting both dynamic and static fire information in an appropriate manner.

  • PDF

A Study about False Alarm of Automatic Fire Detection System (자동화재 탐지설비의 비화재보 감소방안)

  • Lee, Jong-Hwa;Lee, Chun-Ha;Kim, Shi-Kuk;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • The automatic fire detection system is an important facility installed with focusing on minimizing the damage from a fire. This paper presents in the followings as the methods to reduce the false alarm of the automatic fire detection system; first, to prepare for legal standard so that revised legal standard can be applied to the fire fighting property prior to revision; second, to introduce the performance based fire detection protection design in the law based fire protection design; third, to maintain the wiring of worn-out detector; forth, to introduce an evaluation system to the education for the fire warden; fifth, to extend the standard of MTBF(meantime between failure) of the detector; sixth, to extend of installing the analog type detector; seventh, to improve the structure of reset switch.

Development of U-Building Fire Safety Management System (U-건물 화재안전관리 시스템 개발)

  • Kim, Jong-Hoon
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.74-80
    • /
    • 2016
  • Ubiquitous computer technology (U technology) is continually, and the trend is moving towards the miniaturization of devices, cost reduction, performance enhancement, and intelligence. It is important to improve fire safety system by the application of advanced IT technologies. In this study, a vulnerable point in fire safety was selected for improvement by U technology. The structure of the whole system and a unit system was were designed. This system is divided into 5 parts: the U-fire protection facility management system, the U-fire safety information system, the U-fire safety education system, the U-fire response system, and the U-wide area fire safety management system. The prototype system was constructed in a real building to confirm the applicability of the system.

Delphi Study on the Reduction of Cross-contamination and Improvement of Management System on Firefighting Protection Suit (소방 방화복 교차오염 저감 및 관리체계 개선을 위한 델파이 연구)

  • Kim, Soo Jin;Ham, Seunghon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.2
    • /
    • pp.182-194
    • /
    • 2022
  • Objectives: This study evaluates and recommends the priority of policy implementation to improve the fire protection clothing management system used by firefighters and the reduction of cross-contamination from contaminated clothing at the scene of a fire. Methods: It consisted of 7 experts and conducted three interviews and two modified Delphi surveys. Through the results of previous research and interviews with experts, a plan to reduce cross-contamination of fire suits and improve the management system was first derived. An improvement plan was presented in the four areas including resources, management, fire protection related work, and laws and regulations, and the priority of policy implementation was derived by analyzing the importance and practicality of the policy at the same time. Results: As a result of the analysis, the first priority was education on the health effects of pollutants at the disaster scene for firefighters, and the second priority was the addition of SOP for the primary decontamination of on-scene personal protective equipment in preparation for the health effects of the disaster scene, and education for fire suppression and rescue workers. The next step was to improve the management system of personal protective equipment such as fire suits and develop a training course for systematic operation. Conclusions: This findings could be used in the implementation of mid- to long-term firefighting policies for the systematic operation and establishment of a systematic management system for personal protective equipment such as fire protective suits.

The Relationship between Job Satisfaction and Turnover Intention among Fire Protection System Management Workers (소방시설관리업 종사자의 직무만족과 이직의도와의 관계)

  • Lim, Kyoung-Yeon;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.142-151
    • /
    • 2019
  • This study examined job satisfaction among fire protection system management workers in the fire industry and analyzed how job satisfaction affects turnover intention. The results revealed that, among the control variables, including age, rank, academic background, payment, total career, license, and tasks, significant differences in job satisfaction were found in the tasks between groups, while no significant differences in turnover were found in any control variable between groups. Additionally, the results revealed that, among the lower variables of job satisfaction, increased satisfaction with payment and organizational system affected the degree of turnover intention, while work and promotion did not. These results are to be used as data for human management of technicians and for creating alternatives. Future studies are required to establish a reasonable task rotation cycle for raising job satisfaction, to examine the current status of low-cost orders and countermeasures, and to analyze the direction of development of fire protection system management business.

Proposals On The Designe, Construction, Management Maintenance standardization Method Of Mechanical Field Fire Protection System By NFSC (화재안전기준(NFSC)에 따른 기계분야 소방설비 설계, 시공, 감리 유지관리 업무 표준화 방안에 대한 제안)

  • Kim, Sung-Il;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.3
    • /
    • pp.11-17
    • /
    • 2017
  • The study seeks to cooperate with the investigation of a fire investigation based on public-private partnership. Fire protection systems provide a wide variety of viewpoints from the perspectives of design, construction, management, maintenance, maintenance and maintenance systems at a particular point in time, construction, management, and maintenance systems. What is controversial is that there are illegal activities such as illegal activities of the Patent Office, misconduct of construction work and unreasonable construction of construction works.As a theoretical framework, the present study identified the four key elements of a successful disaster response system : responsiveness, control, professionalism, and bias.

Statistics and Management Systems of Unwanted Domestic and Foreign Fire Alarms (국내·외 비화재보의 통계 및 관리체계에 관한 연구)

  • Hwang, Euy-Hong;Lee, Sung-Eun;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.30-40
    • /
    • 2020
  • In the event of a fire and a disaster, prompt and accurate alarms inside and outside the building are directly related to the minimization of damage and the success of life evacuation. However, due to unwanted fire alarms in automated fire detection systems, the number of dispatches by misunderstanding in the 119 service is increasing. This causes the insensitivity to the safety of building managers and the waste of the fire-fighting power. Therefore, in this study, the statistical databases and literature on unwanted fire alarms in Korea and abroad (USA, UK) were identified and the management systems for unwanted fire alarms were compared and analyzed to identify problems of statistics in the management systems for unwanted fire alarms.