• Title/Summary/Keyword: Fire protection safety

Search Result 643, Processing Time 0.024 seconds

An Improved Movable 3 photomultiplier (3PM)-γ Coincidence Counter Using Logical Sum of Double Coincidences in β-Channel for Activity Standardization

  • Hwang, Han Yull;Lee, Jong Man
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.2
    • /
    • pp.76-80
    • /
    • 2020
  • Background: To improve the measurement accuracy of liquid-scintillation counting for activity standardization, it is necessary to significantly reduce the background caused by thermal noise or after-pulses. We have therefore improved a movable 3 photomultiplier (3PM)-γ coincidence-counting method using the logical sum of three double coincidences for β events. Materials and Methods: We designed a new data-acquisition system in which β events are obtained by counting the logical sum of three double coincidences. The change in β-detection efficiency can be derived by moving three photomultiplier tubes sequentially from the liquid-scintillation vial. The validity of the method was investigated by activity measurement of 134Cs calibrated at the Korea Research Institute of Standards and Science (KRISS) with 4π(PC)β-γ(NaI(Tl)) coincidence counting using a proportional counter (PC) for the β detector. Results and Discussion: Measurements were taken over 14 counting intervals for each liquidscintillation sample by displacing three photomultiplier tubes up to 45 mm from the sample. The dead time in each β- and γ-counting channel was adjusted to be a non-extending type of 20 ㎲. The background ranged about 1.2-3.3 s-1, such that the contributions of thermal noise or after-pulses were negligible. As the β-detection unit was moved away from the sample, the β-detection efficiencies varied between 0.54 and 0.81. The result obtained by the method at the reference date was 396.3 ± 1.7 kBq/g. This is consistent with the KRISS-certified value of 396.0 ± 2.0 kBq/g within the uncertainty range. Conclusion: The movable 3PM-γ method developed in the present work not only succeeded in reducing background counts to negligible levels but enabled β-detection efficiency to be varied by a geometrical method to apply the efficiency extrapolation method. Compared with our earlier work shown in the study of Hwang et al. [2], the measurement accuracy has much improved. Consequently, the method developed in this study is an improved method suitable for activity standardization of β-γ emitters.

A Study on the Optimal Design of Soft X-ray Ionizer using the Monte Carlo N-Particle Extended Code (Monte Carlo N-Particle Extended 코드를 이용한 연X선 정전기제거장치의 최적설계에 관한 연구)

  • Jeong, Phil hoon;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.34-37
    • /
    • 2017
  • In recent emerging industry, Display field becomes bigger and bigger, and also semiconductor technology becomes high density integration. In Flat Panel Display, there is an issue that electrostatic phenomenon results in fine dust adsorption as electrostatic capacity increases due to bigger size. Destruction of high integrated circuit and pattern deterioration occur in semiconductor and this causes the problem of weakening of thermal resistance. In order to solve this sort of electrostatic failure in this process, Soft X-ray ionizer is mainly used. Soft X-ray Ionizer does not only generate electrical noise and minute particle but also is efficient to remove electrostatic as it has a wide range of ionization. X-ray Generating efficiency has an effect on soft X-ray Ionizer affects neutralizing performance. There exist variable factors such as type of anode, thickness, tube voltage etc., and it takes a lot of time and financial resource to find optimal performance by manufacturing with actual X-ray tube source. MCNPX (Monte Carlo N-Particle Extended) is used for simulation to solve this kind of problem, and optimum efficiency of X-ray generation is anticipated. In this study, X-ray generation efficiency was measured according to target material thickness using MCNPX under the conditions that tube voltage is 5 keV, 10 keV, 15 keV and the target Material is Tungsten(W), Gold(Au), Silver(Ag). At the result, Gold(Au) shows optimum efficiency. In Tube voltage 5 keV, optimal target thickness is $0.05{\mu}m$ and Largest energy of Light flux appears $2.22{\times}10^8$ x-ray flux. In Tube voltage 10 keV, optimal target Thickness is $0.18{\mu}m$ and Largest energy of Light flux appears $1.97{\times}10^9$ x-ray flux. In Tube voltage 15 keV, optimal target Thickness is $0.29{\mu}m$ and Largest energy of Light flux appears $4.59{\times}10^9$ x-ray flux.

A Study on the Quantitative Process Facility Standards that Require H2S Toxic Gas Detectors and Location Selection for Emergency Safety (H2S 독성가스감지기가 필요한 정량적 공정설비 기준 및 비상시 안전을 위한 위치선정 방안에 대한 연구)

  • Choi, Jae-Young;Kwon, Jung-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.2
    • /
    • pp.90-96
    • /
    • 2018
  • Design techniques for minimizing the damage caused by leakage of $H_2S$ gas, contained in natural gas and petroleum, have been widely studied abroad in chemical plants that purify and process natural gas and petroleum. However, there is no domestic engineering practice and regulation of $H_2S$. In accordance with the circumstances, this study proposes the quantitative criteria of process equipment to install $H_2S$ toxic gas detector as 500 ppm and explains the valid basis. The $H_2S$ gas dispersion radius up to IDLH 100 ppm is calculated by ALOHA under previous $H_2S$ gas leak accident scenario. The weather conditions of modeling include the conditions of Ulsan, Yeosu and Daesan, the three major petrochemical complexes in Korea. The long radius up to 100 ppm was derived in order of Ulsan, Daesan, Yeosu. For emergency safety the dispersion radius up to 100 ppm of the $H_2S$ gas obtained in this study should be extended to apply the additional $H_2S$ toxic gas detector, and local climate conditions should be considered.

A Study on Daylight Control Method for Securing Visual Comfort and Reducing Lighting Loads on Interior Lighting Environment (실내조명환경의 시각적 쾌적성 확보 및 조명부하 저감을 위한 채광제어방법에 관한 연구)

  • Han, Sang-Pil
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.100-105
    • /
    • 2012
  • In previous study, to investigate the impression of the compound lighting based on the AC-Model at the full-size room, the impressions of various compound lighting were completed as compared with that of the uniform lightings through the comparison method (a paired comparison) by Semantic Differential scaling. Also, we examined the effect of the supplementary lighting type increasing the lights at the side of the window and the blind-control lighting type, and they were compared with the existing compound lighting type. In results, pared comparison of the compound lighting and the uniform lighting, indicates that the impression of the compound lighting is generally similar to that of the uniform lighting when there are same ratios of the light from the window. Based on these results, we suggest that the AC-Model might be applied to various conditions. And we also introduce the method for daylighting that it is possible to reduce discomfort glare and to improve visual impressions as the supplementary type and blind-control type on the compound lighting. And it was found that electric power consumption of the compound lighting room was lower than that of the uniform lighting room when as same lighting ratio of the compound lighting and the uniform lighting from the window was provided or there was the lighting distribution simulated to same light ratio from the window. Since the method of the ACModel was described in the experimental condition, additional studies should be performed to determine if this model could be applied to different window configurations, lighting layout and types of a room.

Application of TRA in u-health system focusing on moderating effect of health privacy information (유헬스 시스템에 대한 TRA의 적용에 관한 연구: 건강개인정보의 조절 효과를 중심으로)

  • Kim, Mincheol;Yang, Young-Bae;Ha, Tai-Hyun
    • Journal of Digital Contents Society
    • /
    • v.17 no.6
    • /
    • pp.537-543
    • /
    • 2016
  • The purpose of this study is to analyze the moderating effect of health privacy information on the relationship between the factors that affect the behavioral intention of the usage of u-health system have. Therefore, as a research hypothesis in TRA (Theory of Reasoned Action), self-efficacy and perceived usefulness will have a positive effect on the behavioral intention of the u-health system, and in the path, that personal information factors have an effect on each path. This study used the PLS-SEM methodology to verify the proposed research model. As a result of the analysis, this study showed that the moderating effect of health personal information in the presented model affects to some extent by the increase of R2 explanatory power. However, it was found that it was more consistent with the role of the independent variable rather than the moderating influence on the perceived usefulness.

Analysis on Factors of Importance and Performance in terms of Securing Customers of Farm Restaurants - Based on the Case of Bibijeong in Wanju-Gun - (농가레스토랑 이용고객의 중요도-만족도 분석 - 완주군 비비정을 사례로 -)

  • Han, A-Reum;Han, Jin;Lee, In-Jae;Jang, Dong-Heon
    • Journal of Korean Society of Rural Planning
    • /
    • v.21 no.2
    • /
    • pp.163-175
    • /
    • 2015
  • This study aimed to analyze factors of importance and performance picked by customers of Bibijeong, a farm restaurant operated by the local community of Wanju-gun. Major points include: Recognition paths mostly were word of mouth and mass media, types of visit were in the company of friends, family members or work colleagues, and purposes of visit included consumption of meal and identifying features of the restaurant. Secondly, factor analysis showed that level of facility, atmosphere/cleanness, diversity of menu, employees, ingredients and network. The Cronbach Alpha coefficient was +0.6. Thirdly, average of importance of factors was 3.861 while average performance was 3.429. IPA analysis showed that employee(communication, customer contact) in the first quadrant proved the need for fast improvement through training. Atmosphere/cleanness (interior atmosphere, table clean, kitchen cleanliness, clean dishes, interion design) and employee(proficiency, menu recognition), foodstuff(freshness, origin, safety) in the second quadrant showed that the marketing strategy of improvement as well as maintaining current status is needed, including regular training and hygiene inspection. The third quadrant contains facilities(disability, baby, fire protection) and food menu(food packing, various menu, creative menu, menu description), network(village economic links), which showed the need for gradual improvement. The forth quadrant contains network(sights's near contains. The results so far can be summed into the statement that overcoming the basic functionality of providing meals and linking the restaurant with local attractions and local economy would be need, as well as building up the image of unique farm restaurant with local features, so that Bibijeong can serve as the centerpiece of community and foundation of exchange with other areas.

A Study on the Improvement Plans of Disaster Response Capabilities for U-city (U-City 재난 대응역량 제고방안에 관한 연구)

  • Park, Hee-Soon;Lee, Jeong-Il;Yoon, Hyung-Goog
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.55-66
    • /
    • 2010
  • As people's living standards and expectations for life increase, by applying advanced technology in the city, to enhance the convenience and safety needs are being expanded gradually. Accordingly, so the future of the city to see a viable alternative to that the ubiquitous city fused information communication technologies, large-scale projects conducted at the national level. Sectoral Disaster Prevention is ready for sure how much the lack of response capabilities in the field for checking solution has been suggested for The National Emergency Management Agency. These results present a Sectoral Disaster Prevention response capabilities somewhat different in were identified. Through these are proposed policy recommendations about Sectoral Disaster Prevention and insufficient areas of step response capabilities and building fire protection system approach combines ubiquitous technology in the new paradigm rather than traditional disaster management, greet era of ubiquitous.

A Study on the Daily Inspection Optimization of the Rolling Stocks (철도차량 일상검수 최적화에 관한 연구)

  • Kang, Byoung-Soo;Lee, Kang-In
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.7 no.4
    • /
    • pp.41-47
    • /
    • 2012
  • Railroad rolling stock has long service life and a lot of maintenance cost running on rail by wear and vibration. And it is very important to get optimization of maintenance. This paper want to analyze rolling stock maintenance situation of KORAIL and find out its improvement methods. Especially, the purpose of this paper is to adopt the most effective maintenance period and methods to daily inspection which needs many maintenance manpower in rolling stock. Rolling stock has self-diagnosis function using computer system and the quality of rolling stock has much improved these days but current daily inspection repeat for short period routinely and it is very ineffective. Therefore, the paper adopt improved daily inspection period reflecting the characteristics of rolling stock, and want to secure reliability of rolling stock and minimize maintenance cost.

  • PDF

A Study on Characteristic Analysis for Indoor Ventilation Performance of Mechanical Ventilation System (기계 환기시스템의 실내 환기성능 특성 해석에 관한 연구)

  • Ku, Jae-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.2
    • /
    • pp.31-37
    • /
    • 2012
  • This paper describes to analyze the ventilation performance of a room air conditioner for indoor comfort control. An experimental apparatus consists of a test room, the room air conditioner, a tracer gas measurement system, a supply fan and a controller. Ventilation performance as a function of human occupancy is evaluated with supply ventilation air using a tracer gas technique of CO2 gas in the test room. The ventilation performance is evaluated in a step-down method based on ASTM Standard E741-83 and is found to increase with increasing supply ventilation rate. The CO2 gas concentration is decayed rapidly without human occupancy. The ventilation performance without human occupancy increases up to 55% and the ventilation performance with one person increases up to 25% at the supply air of 570 lpm comparing with a natural reduction after one hour. A modeling for ventilation performance of a room air conditioner in a test room is presented using experimental datum.

Analysis on Information Use of Smartphone in the context of Tourists (관광객 대상 스마트폰 사용의 정보이용 분석)

  • Jee, Geun-Sung;Kim, Min-cheol;Ha, Tai-Hyun
    • Journal of Digital Contents Society
    • /
    • v.18 no.8
    • /
    • pp.1543-1550
    • /
    • 2017
  • Previous research on smartphone has been focused on personal performance, accessibility, and information gaps in information system quality. In order to analyze the relationship between the use of smartphone information and personal characteristics, this study conducted a survey of 300 tourists at Jeju Airport, by using three variables of self-efficacy, 'impulsiveness and demographic variables (age, sex, education level, etc.) of smartphone use with personal characteristics. In conclusion, self-efficacy and impulsiveness seem to be positively related to the use of smartphone because it seems to be a living environment in which the desired information can be acquired within a desired time. In addition, there seems to be a difference between a mobile native environment in which online and offline boundaries are always connected and an environment in which 40 to 50 digital literacies are connected. This can be interpreted as a result of additional analysis.