• Title/Summary/Keyword: Fire protection safety

Search Result 643, Processing Time 0.019 seconds

A Study on the Analysis of Hazardous Risk Factors for Component in Hydrogen Station with Water Electrolysis Device (수전해 수소충전소 부품별 유해위험요인 분석)

  • Seo, Doo-Hyoun;Rhie, Kwang-Won;Kim, Tae-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.33-38
    • /
    • 2019
  • In order to invigoration the hydrogen economy, production of hydrogen needed for hydrogen charging stations and hydrogen fuel cells is needed. Generally, it is reforming used to coal fuel or natural gas. Other technologies include water electrolysis using pure water. Among these water electrolysis technologies, development is mainly carried out using PEM(Polymer Electrolyte Membrane electrolysis). In this study, the company aims to identify potential harmful hazards to PEM electrolysis hydrogen stations in the development stage among hydrogen charging stations. In order to find the hazardous factors in the facilities of the electrolysis and hydrogen charging stations, we were analyzed by Failure Mode & Effect Analysis(FMEA).

A Study on the Institutional Improvement Plan through Consumer Survey of Financial Support Programs for Industrial Accident Prevention (산업재해 예방을 위한 재정지원사업의 수요자 설문조사를 통한 제도적 개선방안 연구)

  • Bae, Dong Chul
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.4
    • /
    • pp.62-71
    • /
    • 2018
  • The purpose of this study is to conduct surveys on demanders using financial aid projects to prevent industrial accidents and to improve them. It is divided into clean business and loan support business through the structured questionnaire. In the case of clean business, the following results were obtained. Most of the applications were received within three months after application. The most important factor considered by the consumer is the amount of support, which is considered to consider the substantial improvement as follows.The expectation for the reduction of industrial accidents after the project was 96.1% and compared to before and after the actual business, it showed a 46.8% decrease from the previous year. In addition, the cost decreased by 21.8%, the facility utilization rate increased by 24.4%, the sales increased by 15.9%, and the average number of workers increased by 6.0. As for the sustainability of the business, 86.6% of the respondents said that they should continue to do so. The following results were obtained in the case of loan support projects. Industrial accidents decreased by 45.2% from the previous year. Costs decreased by 19.4%, facility utilization rose by 26.7%, sales increased by 14.9%, and the number of workers increased by an average of 2.8. In the case of suppliers, prevention of industrial accidents at the business sites participating in the clean business was the highest factor (67.0%). 89% of respondents were aware of the disposal criteria for ineligible suppliers. 50.6% of the respondents answered that it is appropriate to maintain the current level, and 39.4% of respondents answered that they should strengthen. The prices for the support items were more than 15% higher than the market prices.

A Study on Magnetic Field Reduction Design Technique around 345 kV Transmission Line with 2-wire Set Passive Loop (2선식 수동루프를 이용한 345[kV] 송전선 주변의 자계저감 설계기법 연구)

  • Kim, Eung Sik
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.5
    • /
    • pp.10-17
    • /
    • 2021
  • The controversy over the risk of the human body being affected by electromagnetic fields emitted from 60 Hz power lines continues without end. There are currently no new studies or research progress being made in this direction that is notable, and the number of civil complaints is gradually increasing. The problem is that each study produces different results, among which the effect of exposure to magnetic fields on childhood leukemia is a major one. In Korea, an electrician who was maintaining a 22.9 kV power line died of leukemia, which has recently been recognized as an occupational disease. Methods to reduce magnetic fields from power lines include shielding with wire loops, incorporating split phases and compaction techniques, installing underground power lines, converting to high-voltage direct current (HVDC), and increasing the ground clearance of transmission towers. Depending on whether a separate power supply is needed or not, there are two types of wire loops: passive loop and active loop. Magnetic field reduction is currently done through underground power lines; however, the disadvantage of this process is high construction costs. Installing passive loops, with relatively low construction costs, leads to lower magnetic field reduction rates than installing underground cables and a weakness to not solving the landscape problem. This methodological study aims at designing methods and reducing the effects of 2-wire set loops-the simplest and most practical. Since the method proposed in this study has been designed after analyzing the distribution of complex electromagnetic fields near the expected loop installation location, a practical design can be implemented without the need for any difficult optimization programming.

Investigation of the Potential Risk for Musculoskeletal Disorders in Migrant Workers (외국인근로자의 근골격계질환 발생가능성에 관한 연구)

  • Lim, Hyung-Duk;Rajitha Kawshalya, Mailan Arachchige Don;Nam, Ki-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.781-786
    • /
    • 2021
  • Korean domestic workers are trend to avoid harmful and dangerous jobs calls 3D work due to the poor working conditions. Therefore, the incoming population of foreign workers is increasing to fulfill the required labor force. Mostly these foreign workers are placed in small and medium-size industries. As work that induces musculoskeletal disorders(WMSD) is equally exposed to domestic workers as well as foreign workers, this study attempted to investigate the work burdened by musculoskeletal disorders and derive improvement measures by understanding the actual conditions of the worksites of foreign workers. The result of this investigation defines that the possibility of developing musculoskeletal disorders is very high in the environment in which more than 40% of the respondents work with heavy objects and repetitive work of wrists and elbows. To prevent the symptoms of musculoskeletal disorders among foreign workers, three measures were proposed. To reduce the mandatory check-up period of WMSD under the Occupational Safety and Health Act, to revise the employment permit system, and to enhance the practical help of EPS education. Safety and health management of foreign workers is becoming an essential task not only for securing a workforce but also for the national image. Personal and economic losses at the national level should be minimized through policy support such as financial support for small and medium-sized businesses in Korea and supplementation of legal systems for the protection of foreign workers.

The Effects of Knowledge Management System for Earthquake disaster Management on the Disaster Management Job Performance (지진 재난관리를 위한 지식경영시스템이 재난관리 업무성과에 미치는 영향)

  • Shin, KwangSoon
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.353-363
    • /
    • 2020
  • Purpose: The purpose of this study is to verify the effects of assessment and compensation system, information technology, knowledge quality, and knowledge management activities on the earthquake disaster management job performance. Method: Questionnaire survey was performed for the fire officials, and the multi-regression analysis for surveyed data was statistically performed by using SPSS 25.0 program. Result: Information technology, knowledge quality and knowledge management activities among the factors of the knowledge management system related to earthquake disasters have had significant positive effects on the earthquake disaster management job performance, but assessment and compensation system are found to have no significant effects on the earthquake disaster management job performance. Conclusion: It was confirmed that the higher the level of information technology, knowledge quality and knowledge management activities related to earthquake disasters, the higher the disaster management job performance.

Effect of a CPR Educational Face Shield on Pathogenic Bacteria Protection (심폐소생술 교육용 페이스 쉴드의 병원성 세균 차단 효과)

  • Kim, Eun-Mee;Shim, Gyu-Sik;Roh, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.137-141
    • /
    • 2016
  • Cross contamination between a patient and rescuer or CPR trainees can occur when performing mouth to mouth ventilation during cardiopulmonary resuscitation (CPR). On the other hand, there has been a lack of research on the filtration efficacy of face shields that are designed to protect people from cross-contamination. This study aims to secure the safety of rescuers from communicable diseases in pre-hospital emergency settings and CPR trainees by verifying the protective effects of face shields. The FA shield and CM Shield were used to verify the safety. The bacteria collected from filters used by CPR trainees were incubated. These incubated bacteria were smeared onto the new filters, and were then blown out through the filters using a Bag Valve Mask (BVM) and the pathogens at the front and the back of the filters were checked. While the FA shield was effective in preventing the transmission of pathogens, the CM shield did not prevent the transmission of pathogens. Therefore, some of face shields that received national certification are ineffective in preventing cross-contamination. Accordingly, it is necessary to verify the safety of other face shields used domestically.

A comparative study of risk according to smoke control flow rate and methods in case of train fire at subway platform (지하철 승강장에서 열차 화재 시 제연풍량 및 방식에 따른 위험도 비교 연구)

  • Ryu, Ji-Oh;Lee, Hu-Yeong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.4
    • /
    • pp.327-339
    • /
    • 2022
  • The purpose of this study is to present the effective smoke control flow rate and mode for securing safety through quantitative risk assessment according to the smoke control flow rate and mode (supply or exhaust) of the platform when a train fire occurs at the subway platform. To this end, a fire outbreak scenario was created using a side platform with a central staircase as a model and fire analysis was performed for each scenario to compare and analyze fire propagation characteristics and ASET, evacuation analysis was performed to predict the number of deaths. In addition, a fire accident rate (F)/number of deaths (N) diagram (F/N diagram) was prepared for each scenario to compare and evaluate the risk according to the smoke control flow rate and mode. In the ASET analysis of harmful factors, carbon monoxide, temperature, and visible distance determined by performance-oriented design methods and standards for firefighting facilities, the effect of visible distance is the largest, In the case where the delay in entering the platform of the fire train was not taken into account, the ASET was analyzed to be about 800 seconds when the air flow rate was 4 × 833 m3/min. The estimated number of deaths varies greatly depending on the location of the vehicle of fire train, In the case of a fire occurring in a vehicle adjacent to the stairs, it is shown that the increase is up to three times that of the vehicle in the lead. In addition, when the smoke control flow rate increases, the number of fatalities decreases, and the reduction rate of the air supply method rather than the exhaust method increases. When the supply flow rate is 4 × 833 m3/min, the expected number of deaths is reduced to 13% compared to the case where ventilation is not performed. As a result of the risk assessment, it is found that the current social risk assessment criteria are satisfied when smoke control is performed, and the number of deaths is the flow rate 4 × 833 m3/min when smoke control is performed at 29.9 people in 10,000 year, It was analyzed that it decreased to 4.36 people.

A Study on Improvement of Discharge Obstruction Prevention Standard for Sprinkler Head on NFSC 103 (스프링클러설비 소화성능 향상을 위한 NFSC 103 살수장애 방지기준 개선 방안에 관한 연구)

  • Kim, Sunghyun;Lee, Sungsu
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.237-247
    • /
    • 2020
  • Purpose: This study aims to draw the problems and improvements of NFSC 103 sprinkler head discharge obstruction prevention standard to increase the fire extinguishing performance of sprinkler system in order to contribute to the protection of people's lives and property in the event of a fire. Method: NFSC 103 was compared to NFPA 13 which is the latest 2019 version in U.S in terms of sprinkler head discharge obstruction prevention. Results: This study found that NFSC 103 doesn't define even the basic concept of sprinkler discharge obstruction. And NFSC 103 doesn't have detailed standard for side wall sprinkler head discharge obstruction prevention as well as the "height" criteria of the "three times" separation rule. Conclusion: NFSC 103 needs a lot of supplements and improvements such as the addition of definition for water discharge obstructions, the adoption of sidewall sprinkler heads standard for preventing water discharge obstructions and the additional establishment of the "three times rule" considering the "height" of obstacles to promote the advance of fire safety standard equal or above fire fighting advanced country and increase the reliability for the suppression performance of sprinkler system.

Na3PO4 Flame Retardant Treatment on Lyocell Fiber for Thermal Stability and Anti-oxidation Properties (라이오셀의 열 안정 및 내산화 특성 향상을 위한 Na3PO4 내염화 처리)

  • Kim, Hyeong Gi;Kim, Eun Ae;Lee, Young-Seak;In, Se Jin
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.25-32
    • /
    • 2015
  • The improved thermal stability and anti-oxidation properties of lyocell fiber were studied based on flame retardant treatment by using $Na_3PO_4$ solution. The optimized conditions of flame retardant treatment were studied on various concentrations of $Na_3PO_4$ and the mechanism was proposed through experimental results of thermal stability and anti-oxidation. The integral procedural decomposition temperature (IPDT), limiting oxygen index (LOI) and activation energy ($E_a$) increased 30, 160% respectively via flame retardant treatment. It is noted that thermal stability and anti-oxidation improved based on char and carbon layer formation by dehydrogenation and dissociation of C-C bond resulting the hindrance of oxygen and heat energy into polymer resin. The optimized conditions for efficient flame retardant property of lyocell fiber were provided using $Na_3PO_4$ solution and the mechanism was also studied based on experimental results such as initial decomposition temperature (IDT), IPDT, LOI and $E_a$.

A Study on the Effects of Droplets Characteristics of Water Mist on the Spray Density on the Floor (미분무 액적특성이 살수밀도에 미치는 영향 연구)

  • Kim, Jong-Hoon;Park, Won-Hee;Kim, Woon-Hyung;Myoung, Sang-Yup
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.120-127
    • /
    • 2021
  • Purpose: In this study, the effect of changes in the variables related to water droplets on the spray density on the floor in the analysis of the water mist fire protection system using FDS was analyzed. Method: When the spray of the water mist nozzle was analyzed in FDS, Particles Per Seconds, Particle Velocity, Size Distribution, and Spray Pattern Shape that can be set in relation to droplets were input to review the analyzed results. Result: In the analysis results, when the number of particles per second was set above a certain value, the spray density of the floor was similar. In the case of Particle Velocity, as the velocity decreases, the spray density of the central portion increases but decreases at a distance of 0.15m or more. From the analysis of the change in the size distribution function, it was found that an increase in the 𝛾 value increases the spray density of the central part, but the value at a remote location decreases. Compared to the result of applying the Gaussian distribution, the median value decreases dramatically when the uniform distribution is applied, but the value at the adjacent position increases. Conclusion: Variables related to the droplet properties of the FDS affect the spray density of the floor. Therefore, in order to increase the reliability of results before performing analyses such as fire suppression or cooling, a sufficient review of input variables is required.