• Title/Summary/Keyword: Fire protection equipment

Search Result 172, Processing Time 0.023 seconds

Improvement of fire protection equipment the opening of according to narrow the distance between buildings (건물 간 이격거리 협소에 따른 개구부 방화설비의 개선방안)

  • Oh, Taek-Hum;Park, Chan-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.61-68
    • /
    • 2013
  • In the case of the fire to the exterior of the building through openings, the openings of the adjacent building are exposed to the risk of combustion expanding and factors that affect the combustion in the radiant heat and direct flame. Recent five years, fire of the adjacent building indicated that incidence of the 5,134(2.27%) among total 225,934 cases occurred The damage scale of fire expanded was lower than in a single building but casualties(5.46%) and property(25.0%) damage were higher. Therefore, this study provides to analyze the operating status for fire protection equipment of fire-preventing area in the Seoul and to apply measures to improve fire protection equipment according to narrow the distance between the building openings studied.

A Study on the Reformation of Certified Fire Fighting Specialists - Focused on Fire Protection System Managers - (소방전문자격사제도의 개선에 관한 연구 - 소방시설관리사를 중심으로 -)

  • Oh, Hyeong-Geun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.4 s.23
    • /
    • pp.21-28
    • /
    • 2006
  • This research analyzed the operational status of fire protection system managers who execute self inspection of the fire equipment in the specific fire protection facilities and presented the improvement scheme. Being made up inquiry for job environment, institutional environment, and operational environment for the subject of fire protection system managers who execute self inspection to complement the fire equipment inspection by city public fire protection service, the issues of the operational status of the institution of fire protection system managers were positively understood. The research result showed the conflict among building owner, fire equipment inspector, and fire protection system manager was existed due to the legal and institutional inertia to the self inspection, so it is judged that mutual complementary and cooperative relation should be established.

Development of Composite Examination Equipment for Improvement of Fire Detectors Checking Technology (감지기의 점검 기술향상을 위한 복합시험기의 개발)

  • Kong, Ha-Sung;Lee, Jong-Hwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.4
    • /
    • pp.135-143
    • /
    • 2008
  • Recently as the testing of fire detector used the testing device for fire detector, there are something the matter in the perception function loss of fire detector, structure and form of the testing device for fire detector. The problem at oxidation of emitting smoke ashes hazardous article part and so on that checking person absorbs be. In this paper the problem or the conventional the examination equipment of fire detectors is analysed and researched. To solve these problems after the theoretical study and design and paint drawing of equipment the prototype of composite examination equipment of fire detectors was made. After compared with the conventional, part that improve of composite examination equipment of fire detectors are verified through the examination. In the future it will be useful the operation state and correct operation time of the fire detectors are measured after the research about the quality of the material and transparency of bellows cover is done.

A Study on the Firefighting Equipment in Petrochemical Plants (석유화학공장의 소화설비에 관한 연구)

  • Kim, Bong-Hoon;Choi, Jae-Wook;Lim, Woo-Sub
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.14-22
    • /
    • 2014
  • Hydrocarbon fires and explosions in petrochemical plants have occurred repeatedly every year. But domestic law of fire protection system is insufficient for the worst case scenario. In this study, we analyzed domestic and foreign standards of fire protection system in petrochemical plants and surveyed firefighting equipment of 32 petrochemical plants in ulsan petrochemical complex. Finally, it is necessary to design fire water supply based on the worst case scenario in petrochemical plants and firefighting equipment such as fixed water spray system, elevated monitor nozzle, water curtain, large amount foam monitor system should be installed for the worst case scenario in petrochemical plants.

A Study on the Response Characteristics of Fire Frequency 447 MHz and 2.4 GHz (소방용주파수 447 MHz와 2.4 GHz의 응답특성에 관한 연구)

  • Oh, Sae-Byeol;Kim, Si-Kuk;Jee, Seung-Wook;Lee, Chun-Ha;Kim, Hyeong-Gweon;SaKong, Seong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.31-34
    • /
    • 2011
  • 본 논문은 소방용 무선주파수로 도입 예정인 447 MHz와 2.4 GHz의 응답특성을 확인하고자, 한국소방산업기술원에서 개발된 447 MHz 무선모듈과 2.4 GHz 무선모듈을 이용하여 건축물 내에서 무선통신 환경에 영향을 줄 수 있는 대표적 장애물인 벽체를 시료로 하여 두 주파수 간의 응답특성을 비교 분석하였다. 도출된 결과를 바탕으로 향후 도입될 소방용 무선주파수 선정을 위한 기초 자료로 활용하고자 한다.

  • PDF

A Study on the Analysis and Improvement of Current Fire Protection Standard for Buildings (현행소방시설설치기준의 분석과 개선방안에 관한 연구)

  • 정병재;이경회
    • Fire Science and Engineering
    • /
    • v.4 no.2
    • /
    • pp.3-13
    • /
    • 1990
  • Fire Protection System is facilities that Control the fire by mechanic means. Buildings Over a Certain Scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment the kinds are various. With the development of architecture technique while modern higher buildings are increased. As fire is a first product that human make, it performed many profits and services for our mankind. Sometimes as it is profitable fire or harmful fire, it takes charge of human's life culture. Therefore fire protection system is facilities that control the ]after fire by mechanic means Building over a certain scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment, the kinds are various. With the development of architecture technique while modern Higher buildings are increased high level and fire prevent facilities aren't reached to that level. The object of this study is present the problem which appear from the analysis of place standard for fire protection facility. This study described as a following order. First. We are going to look history of the fire protection system and change course of that with the year and facility. Second, We say the frame system and special nature of the foreign fire prevent Act. Third. We understand the control reality of fire protection system. Fourth. We took out the merit of foreign fire prevent law and the problem of our current domestic system. The placing standard of proper fire protection facilities that be presented from this study are followed next. 1) We have reinforce sprinkler system placing standard for the fire extinguishing and check the spread of fire. 2) We must to be ruled the standard for keeping fire prevention system that are received reality and people's idea. 3) We should prepare lawful basis which can be place fire prevention center. 4) We have to correct the standard of use about complex building without mainuse and we take increase the real effectiveness of this. 5) We ought to match the use of current fire prevention act and the use of architecture law.

  • PDF

Part II A Study on the Analysis and Improvement of Current Fire Protection Standard for Buildings (현행소방시설설치기준의 분석과 개선방안에 관한 연구II)

  • 정병재;이경회
    • Fire Science and Engineering
    • /
    • v.5 no.1
    • /
    • pp.5-14
    • /
    • 1991
  • Fire Protection System is facilities that Control the fire by mechanic means. Buildings Over a Certain Scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment the kinds are various. With the development of architecture technique while modern higher buildings are increased. As fire is a first product that human make, it performed many profits and services for our mankind. Sometimes as it Is profitable fire or harmful fire, it takes charge of human's life culture. Therefore fire protection system is facilities that control the latter fire by mechanic means Building over a certain scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment, the kinds are various. With the development of architecture technique while modern higher buildings are increased high level and fire prevent facilities aren't reached to that level. The object of this study is present the problem which appear from the analysis of place standard for fire protection facility. This study described as a following order. First, We are going to look history of the fire protection system and change course of that with the year and facility. Second. We say the frame system and special nature of the foreign fire prevent Act. Third. We understand the control reality of fire protection system. Fourth. We took out the merit of foreign fire prevent law and the problem of our current domestic system. The placing standard of proper fire protection facilities that be presented from this study are followed next. 1) We have to reinforce sprinkler system placing standard for the fire extinguishing and check the spread of fire. 2) We must to be ruled the standard for keeping fire prevention system that are received reality and people's idea. 3) We should prepare lawful basis which can be place fire prevention center. 4) We have to correct the standard of use count about complex building without mainuse and we take increase the real effectiveness of this. 5) We ought to match the use of current fire prevention act and the use of architecture law.

  • PDF

A Study on Authoritativeness of Electric Fire by Activating of Fire Damaged MCCB (소손된 배선용 차단기 동작상태에 의한 전기화재 규명의 신뢰성에 관한 연구)

  • Lee, Jong-Hwa;Mun, Yong-Soo;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2009
  • In the fire there are fusion signs and damage by fire, and insulation aging and carbonization of the electric wiring in the ignition spot because of special characteristic of the appliance in the electricity fire. Because of the physical factor applied in the damage of fire, the decision of ignition spot by eye investigation is insufficient. In this paper, the cause of electricity fire is researched. The focus is on the operation state of operated MCCB(Molded Case Circuit Breaker) at the time of electricity fire. Through grasping the operation principle of MCCB and the experiment, the state of MCCB after fire suppression is discriminated. The distinction possibility on the exist of electricity fire is proposed.

A Study on Effective Fire Countermeasures for Facilities for the Elderly and Children (노유자시설의 효율적인 화재 대응방안에 관한 연구)

  • Hwang, Euy-Hong;Choi, Han-Bit;Choi, Doon-Mook
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.107-114
    • /
    • 2020
  • With the development of the national industry, the importance of the elderly and children such as the elderly, disabled, and children is recognized. Similarly, the number of facilities for the elderly and children is increasing. Fires at facilities for the elderly and children cause heavy casualties. In response to these events, it is essential to activate fire alarms promptly and accurately and to secure evacuation routes. In this study, the laws and statistics related to facilities for elderly and children were reviewed, and problems with legal terms-such as elderly, children, others, unwanted alarm of fire alarm systems, blind spots of fire compartment standards, securing evacuation routes, and absence of standards for life safety rescue organizations-were identified. As an improvement measure, the legal definitions of similar terms-such as elderly, children, unwanted alarm checklist, and establishment of standards for fire prevention compartment-and introduction of other terms-evacuation elevators, the establishment of standards for life-safety rescue organizations, and provision of flame retardation objects for evacuees-were proposed.