• 제목/요약/키워드: Fire proofing protection

검색결과 8건 처리시간 0.02초

내화피복이 생략된 합성보의 구조설계지침 제정을 위한 고찰 (Structural Design Guide Line of Composite Beam)

  • 홍원기;김진민;이경훈;박선치;김점한
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.93-98
    • /
    • 2008
  • As high rise buildings and large span spatial structures are constructed, new composite members and construction techniques are continuously developed. Wide flange steel beam can be easily constructed but the fire proofing protection is necessary and the cost is high. Nowadays environmental pollution of structures is becoming a big issue. The material of fire proofing protection is not allowed to use for structural members in several countries because it cab be a cause of environment pollution. Composite beam is a new hybrid beam system which is not needed a fire proofing protection process. Composite beam has better construction capacity than that of RC system and has more economic advantages than that of wide flange steel beam. In this paper, structural design guide lines of composite beam were provided to apply design and construction.

친환경 층고 절감형 합성보의 시공 Process 및 시공사례 (Environmental Friendly Construction Process of Composite Beam and its Application)

  • 홍원기;박선치;이경훈;김점한;이호찬;황윤하
    • KIEAE Journal
    • /
    • 제7권6호
    • /
    • pp.107-112
    • /
    • 2007
  • Recently hybrid beam system is widely used because it has many structural advantages such as short construction period and low story height etc. Generally steel wide flange beam exposure type and embedded type hybrid beams are constructed. Even though exposure hybrid beam is easily constructed, the fire proofing protection process is necessary because steel wide flange beam cannot resist to fire itself. Story height reduction type hybrid beam, which is introduced hybrid beam in this paper, does not need fire proofing protection process because it is constructed as a fully embedded type hybrid beam. Developed construction process and actual construction cases of story height reduction type hybrid beam were introduced in this study.

신개발 내화재료에 피복된 철근콘크리트 터널라이닝의 내화성능평가 (Evaluation of fire-proofing performance of reinforced concrete tunnel lining coated by newly developed material)

  • 박해균;김장호
    • 한국터널지하공간학회 논문집
    • /
    • 제10권4호
    • /
    • pp.329-336
    • /
    • 2008
  • 도심지 생활 편의를 위한 효율적인 교통 네트워크가 요구되고 있다. 그러나 과밀한 교통 네트워크는 교통체증은 물론 지반환경에 좋지 않은 영향을 주고 있어 터널 및 지하공간에 대한 효율적인 사용과 개발이 요구된다. 지난 20년간 전세계에서 많은 터널 화재사고가 발생하였으며, 그 결과 인명 및 구조물 피해는 물론 경제적으로 큰 손실을 초래하였다. 산악터널의 경우에는 화재 발생에 따른 터널 라이닝의 손상이 터널 안전성에 큰 영향을 주지는 않을 것이다. 그러나, 쉴드터널, 침매터널, 개착터널의 콘크리트 라이닝은 구조부재로 사용되는 관계로 화재 발생이 터널 붕괴로 이어지는 위험성을 안고 있다. 본 연구의 목적은 새롭게 개발된 시멘트계 내화재료로 피복된 터널 철근 콘크리트 라이닝의 내화성능을 평가하기 위함이다. 콘크리트 라이닝 시편을 대상으로 독일의 RABT 내화곡선(최고온도 $1,200^{\circ}C$), 네델란드의 RWS 내화곡선(최고온도 $1,350^{\circ}C$)을 이용하여 실험을 실시하였으며, 그 결과 RABT 내화곡선 하에서는 30mm의 내화피복만으로도 우수한 내화성능을 확인할 수 있었다.

  • PDF

화재시 연기확대 방지를 위한 건축물 구획공간에서의 방연성능 확보에 관한 조사 연구 (A Study on the Protection of Smoke Control Performance in Building Enclosure to Prevent the Expansion of Smoke in Fire)

  • 진승현;김혜원;이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.91-92
    • /
    • 2019
  • In case of fire in a compartmentalized building area, a number of casualties are caused by smoke production. Accordingly, openings, penetrations and joints in compartmentalized spaces should be secured not only for fire resistance but also for smoke-proofing. However, domestic test regulations stipulate test methods for refractory performance of penetrations and joints, but do not specify separate deferral performance. In the case of openings, the test for the smoke performance exists at room temperature, but the smoke performance at high temperature is not secured, so countermeasures are needed.

  • PDF

막재료의 설치높이와 발열량에 따른 화재연소특성 (Fire Combustion Characteristics of Membrane Materials According to the Height and Heat Generation Rate)

  • 조승호;최광호;노영숙
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권6호
    • /
    • pp.84-90
    • /
    • 2016
  • 최근 다양한 형태의 막구조물의 건설이 증가추세이지만 막구조물에 적합하지 않은 내화기준이 적용되어 활용성이 위축되고 있는 실정이다. 그렇기 때문에 막구조물의 건설 활성화에 맞추어서 이에 대한 내화기준의 제 개정이 필요한 상황이다. 따라서 본 연구에서는 일반적으로 많이 사용되는 막재료(ETFE, PVF, PTFE)를 선정하여 막구조물에 화재가 일어났을 때, 시간이 변화함에 따라 온도가 올라가는 막재료의 물리적인 특성 변화와 발열량과 막재료 설치높이와의 상관관계를 파악하여 막구조 내화기준에 기초 자료로 활용하고자 한다.

3성분계(Li/Na/K) 용해성 규산염을 이용한 방화피복재의 개발 (A Development of Fire Protective Coatings using Ternary(Li/Na/K) Soluble Silicate)

  • 이내우;김정훈
    • 한국안전학회지
    • /
    • 제10권1호
    • /
    • pp.28-34
    • /
    • 1995
  • To improve fire proofing characteristics of protective coating using ternary soluble silicate from two component mixture, the method of reducing solubility, increasing intumescence and protection time have been studied. Intumescence and solubility of ternary silicate mixtures were dependent on many kinds of water release and the strength of cation cross-links between polysilicate particles. Especially the effect of additive, for example, corn starch was investigated. However the solubility of ternary mixture is decrease in order of Na$^{+}$ >K$^{+}$ >Li$^{+}$, and the magnitute of intumescence is increased $K^{+}$ >Na$^{+}$ >Li$^{+}$.}$ +/.

  • PDF

방폭구조 ESD Detector 개발 및 본질안전 특성 분석에 관한 연구 (A Study on the Development of Explosion Proof ESD Detector and Intrinsic Safety Characteristics Analysis)

  • 변정환;최상원
    • 한국안전학회지
    • /
    • 제35권1호
    • /
    • pp.1-11
    • /
    • 2020
  • Article 325 (Prevention of Fire Explosion due to Electrostatic) of the Rule for Occupational Safety and Health Standard specifies that in order to prevent the risk of disasters caused by static electricity, fire, explosion and static electricity in the production process, However, in order to do this, it is absolutely necessary to use a pre-detection technology and a detector for antistatic discharge prediction, which is a precautionary measure by static electricity in a fire / explosion hazard place, but in Korea, And there is no technical standard for the application of the technology of the explosion proof structure of the related equipment. Research methods include domestic and overseas electrostatic discharge detection technology and literature investigation of related equipment explosion proofing technology, domestic and foreign electrostatic discharge detection device production and use situation investigation, advanced foreign technology data analysis and benchmarking. In particular, we sought to verify the results of empirical experiments using electrostatic discharge detection technology through sample purchase and analysis of related major products, development of optimization technology through prototype production, evaluation, and supplementation, and expert knowledge through expert consultation. The results of this study were developed and fabricated two prototypes of electrostatic discharge detector based on the technology / standard related to electrostatic discharge detection technology in Korea and abroad through development of electrostatic discharge detection technology and development and production of detector. In addition, based on the development of electrostatic discharge detection technology, we developed an intrinsic safety explosion proof ib class explosion proof technology applicable to the process of using and handling flammable gas and flammable liquid vapor and combustible dust. In the case of the over voltage and minimum voltage are supplied to the explosion-proof structure ESD detector, check the state of the circuit and the transient and transient currents generated by the coil and capacitor elements during the input and standby of the signal pulse voltage. Explosion-proof equipment-Part 11: Intrinsically safe explosion proof structure The comparative evaluation with the reference curve in Annex A of "i" confirms that the characteristics of the intrinsically safe explosion protection structure are met.

Ecological Green Roofs in Germany

  • Kohler, Manfred
    • 한국환경복원기술학회지
    • /
    • 제7권4호
    • /
    • pp.8-16
    • /
    • 2004
  • The industrialization of central Europe more than 100 ago marked the beginning of densely concentrated buildings in quickly growing cities. A cheap type of roofing material of that time was tar. But it was dangerous because it was high inflammable. Then some roofer had a splendid idea. They used sandy material as a final layer atop the impermeable tar layer. These roofs were much more fire resistant than the typical roofs. In this sandy layer some plant species began to grow spontaneously. This was the beginning of the green roof history of modern Europe. A number of these green roofs survived both world wars. In the early 80's in Berlin alone, 50 such buildings existed and they continued to be waterproof until the present day. Since the 1992 Earth Summit of 1992 in Rio de Janeiro(http://www.johannesburgsummit.org/html/basic_info/unced.html) the term "sustainable development" became of central interest of urban designers. In city regions green roofs had become synonymous with this term. With a small investment, long-lasting roofs can be created. Further back in history, more exciting examples of green roofs can be found. The hanging gardens of antiquity are well-known. There are also green roofs built as insulation against cold and heat all over the world. For over 20 years, roof greening in central Europe has been closely examined for various reasons. Roof greening touches several different disciplines. Of primary interest is the durability of the roofs. But ecologists are also interested in green roofs, for instance in biodiversity research. The beneficial effect of greening on water proofing was also proven. For some time, the issue of fire protection was investigated. According to tests, green roofs received a harsh careful rating. Their fire protective property is considered similar to that of tile roofs. Another recent impulse for the green roof movement in Germany has come from the evident improvement of storm water retention and the reduced burden on the sewer system. The question of whether and how much energy green roofs can save has become an urgent question. The state of the research and also various open questions from a central European point of view will be discussed in the context of international collaboration. Apart from academic considerations, those who involve themselves in this issue take a predominantly positive view of the numerous existing green roofs in Germany. In some cities, green roofs are the typical construction technique for new buildings. A few outstanding examples will conclude this review. In Germany, about 20 companies, some of which operate internationally, specialize in green roof consulting. Learning from each other in an open-ended way with respect to different construction techniques and applications in various climatic regions can only be accomplished through such international collaboration as is taking place here.