• Title/Summary/Keyword: Fire prevention management

Search Result 389, Processing Time 0.024 seconds

Efficient Disaster Response Plan for Tunnel Fire Safety (터널 화재안전에 대한 효율적 재난대응 방안)

  • Jeong-Il Lee
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.2
    • /
    • pp.55-64
    • /
    • 2024
  • As the distribution of vehicles and logistics increases due to the development of human civilization and the increase in population, various roads play an important role in domestic traffic and transportation. However, the recent emergence of large cities and new cities is causing traffic problems, and the increase in roads is inevitable for the smooth distribution of vehicles and logistics. In Korea, mountainous regions occupy 70% of the country, so tunnels are used to open roads. Without this, it is difficult to open the road. Currently, there are 3,720tunnels (as of December 31, 2023) installed on high-speed national highways, general national highways, and local roads nationwide, with a length of 2.499 and increasing every year. Accordingly, fire accidents in tunnels will also increase, and due to the nature of tunnel fire accidents, there is a high probability that they will escalate into large-scale disasters, resulting in casualties and property damage, as well as significant social losses due to the disruption of logistics transportation, etc. As the possibility of potential hazards is increasing, the purpose of this study is to build a safe and efficient tunnel system by optimizing maintenance and management for fire and disaster accidents in tunnels.

Development and Application of Performance forms Fire Safety Education Program (공연형 소방안전교육 프로그램 개발 및 적용)

  • Deok-Jin, Jang;Ha-Sung, Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.4
    • /
    • pp.135-142
    • /
    • 2022
  • In school safety education, it was difficult to apply how to link the safety education according to grades year, and student's interest was reduced due to the repetition of existing safety education contents and the absence of new teaching methods and tools. In this study, as a new type of safety education, a performance forms fire safety education program was developed. This program aims to increase students' interest and satisfaction in safety education, and to this end, it was connect with korean elementary science curriculum and combined various engineering teaching materials or tools and methods. Developed program was applied to 2,231 students, 25 schools in 10 regions of Gyeonggi-do and surveyed 476 fifth and sixth grade students program satisfaction and 3 factors of interest in fire safety education who could respond to the survey. As a result of applying the program, more than 90% of students responded more than 'satisfied' in all areas. and statistical test(independent t-test and non-parametric test) indicates over-all satisfaction and interest factors in the program are high regardless of gender and grade, so the effectiveness can be guessed indirectly and there is a universal applicability also. Moreover, examining the influence of student interest level in the satisfaction of the fire safety program, it was found that in order to increase the satisfaction of fire safety education, students should have more fun with the content and feel interest in the teacher's teaching method or explanation.

A Case Study of Disaster Accidents at Construction Site Based on PDCA Theory

  • Shin, Dong-Won;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • v.10 no.3
    • /
    • pp.245-256
    • /
    • 2021
  • This study is significant in determining the reduction of safety accidents by applying PDCA's theory by subdividing it into a case analysis technique for construction sites by PDCA's theory. For this study, accidents accounted for the largest proportion of each type of disaster in the construction site were considered, and safety accidents were reduced through the PDCA theory through prior research. The analysis method of this study derived improvement plans by applying PDCA techniques to plan, implement, confirm, review, and improve disaster accidents at construction sites. The conclusions of this study are as follows. In the plan, first of all, measures shall be taken to prepare a safety management plan, to verify the implementation of the plan, and to verify the degree of implementation by the field manager. In the implementation, first of all, it is necessary to introduce a safety education history system to strengthen the safety education curriculum to suit the site, as long-term work is impossible for field workers depending on field conditions. First of all, it is necessary to strengthen the installation of safety facilities, including "work scaffolding" and "conducting prevention facilities" at construction sites. In management review and improvement, the risk assessment system for construction sites needs to be expanded first°.

A Study on the Heat Release Characteristic of Household Items using LSC(Large Scale Cone Calorimeter) (LSC를 이용한 생활용품의 발열량 특성에 관한 연구)

  • Park, Ju Young;Baek, Chang Sun;Lee, Hae Pyeong;Hong, Yi Pyo
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.38-44
    • /
    • 2015
  • For this study, fire tests were performed targeting household items (Sofa, Drawer, Refrigerator, Washing machine) using a large cone calorimeter (Large Scale Cone Calorimeter, LSC). The data were obtained focusing on the fire characteristic of the data when the actual fire occurs. The study results showed the following mean HRR of the household items; drawer 2843 KW, sofa 2939 KW, washing machine 719 KW, refrigerator 2907 KW, and THR is found in sofa 2202 MJ, drawer 1559 MJ, refrigerator 1193 MJ, washing machine 627 MJ. From the result, it could be found that the sofa can cause significant heat generation when the fire occurs, and the flashover tendency was found relatively high in compartment fire. In addition, a weight of the four our household items was reduced sharply in a similar time (20min before and after) degree after ignition. The drawer and sofa which has a high heat release can be considered to speed up the fire spread as their weight decrease rapidly and showed relatively weak to the fire compared to the refrigerator and washing machine.

Development of Algorithm for Analyzing Priority Area of Forest Fire Surveillance Using Viewshed Analysis (가시권 분석을 이용한 산불감시 우선지역 선정 방안)

  • Lee, Byung-Doo;Ryu, Gye-Sun;Kim, Sun-Young;Kim, Kyong-Ha;Lee, Myung-Boa
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.3
    • /
    • pp.126-135
    • /
    • 2011
  • In this study, the algorithm for priority area of forest fire surveillance was developed to enhance the effectiveness of fire detection. The high priority surveillance area for forest fire detection was defined as the area with not only low value of viewshed analysis of the lookouts and detection cameras but also high fire occurrence probability. To build the priority map, fuzzy function and map algebra were used. The analysis results of Bonghwa-gun, Gyeongbuk Province, showed that the surveillance priority of central and southern area is higher than north area. This algorithm could be used in the allocation of fire prevention resources and selection of suitable point for new fire detection system.

A Study on the Improvement of Safety Management of Hazardous Chemicals Handling in the Workplace (유해화학물질 취급작업장의 안전관리 개선에 관한 연구)

  • Jeong, Gyeong-Sam;Baik, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.12-19
    • /
    • 2014
  • Workplaces handling hazardous chemicals are scattered, because of old-aging facilities are have been operating for more than 20 years, there is still has the risk of an accident. Advanced countries including the UN and strengthen regulation of chemicals, but the frequent leak accidents have become a big issue socially. In the case of subsequent domestic accidental chemical accident, the government and related departments for the overall prevention, preparedness, response system has been checked and improved. In this study, improvements of the related system and the plan of safety management for on the prevention of accidents and the initial response were suggested throughout the analysis of problems on the actual condition of safety management and such as standard of the related systems for handling, management for occurring the main cause of the leak and chemical accidents from hazardous chemicals handling in the workplace.

A Forest Fire Prevention Mechanism using Geographic Information System - The case of Mt. Uam in Cheongju - (지리정보시스템(GIS)을 이용한 산불방재방안 - 청주시 우암산 지역을 중심으로 -)

  • Shin, Young-Chul;An, Sang-Hyun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.3 no.1
    • /
    • pp.23-34
    • /
    • 2000
  • The forest fire covered with forest gets increasing year after year in Korea. Furthermore the scale becomes larger. A forest fire problem is extremely serious. In this situation this study discussed a forest fire prevention with scientific and systematic method. Various information was created using GIS for Mt. Uam, which is located in Uam, Cheongju city. The predictive model to enhance effective forest fire management was developed.

  • PDF

Study on the effective response method to reduce fire risk of wood fuel heating system (화목 연료 난방설비의 화재 위험 감소 방안에 관한 이론적 연구)

  • Park, Kyong-Jin;Lee, Bong-Woo;Lee, Guen-Cull;Nam, Ki-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.2
    • /
    • pp.163-171
    • /
    • 2019
  • Recently, rural housing in urban areas has been increasing due to the improvement of income level. With the increase of the construction of the power house, the installation of the heating system using the harmonious fuel for the purpose of heating and the beauty of the room is increasing rapidly. In addition to the increasing use of firewood heating equipment, the incidence of fire is also increasing. Analysis of the National Fire Data System of the Fire Department The result of the analysis of the National Fire Data System Many parts of the fire are incinerated by the accumulation of tar due to the incompleteness of periodic cleaning inside the cylinder. The distance between the fire extinguisher and the combustible materials such as ceiling, Resulting in fire. In addition, it was found that much of the fire of the firewood heating system in the time zone occurs during the sleeping and resting time and there is not enough time for the residents to cope. This, in turn, causes serious harm to the lives and property of the users of the pyrotechnic heating system. Therefore, in this study, domestic and foreign standards and laws related to fuel oil heating facilities were analyzed and 12 cases of fire accidents were analyzed. Through the revision of the fire prevention and firefighting facilities installation and maintenance law, the installation standards of the alarm and fire extinguishing facilities were presented.

Research about Members' Recognition of Crisis Management System to Preparation Phase of Terror Countermove - Focusing on the Fire Fighting Public Service Personnel - (테러대응 준비단계의 위기관리체제 구성원의 인식에 관한 연구 - 소방지방공무원을 중심으로 -)

  • Oh, Tae-Kon
    • Fire Science and Engineering
    • /
    • v.21 no.2 s.66
    • /
    • pp.24-29
    • /
    • 2007
  • This research is accomplished for the purpose of providing fundamental materials to improve the level of prevention consciousness by deducting awareness difference through analyzing awareness level about terror preparation of members of crisis management system - the public service personnel in charge of crisis management in a self-governing body and the fire fighting public service personnel. For this research, That is measured through the priority order survey about a specialty of public service personnel in charge of crisis management and a level of crisis prepartion and a cooperation between crisis management system and etc. As a result of analysis, it is revealed that there is a difference about the priority order of measurement variable to terror preparation but all the members are recognizing the importance of that.

Comparative Analysis of Flame Retardant Performance of Japanese Cypress Plywood Based on the Main Ingredients of Fire Retardant Paint (도료의 주성분에 따른 편백 합판의 방염성능 비교 분석)

  • Soo-Hee Lim;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.1
    • /
    • pp.61-66
    • /
    • 2023
  • The purpose of this study is to compare and analyze the flame retardant performance of Japanese cypress(Chamaecyparis obtusa) plywood, commonly used in indoor decoration, furniture, and tableware, by treating it with three different fire retardants with different primary ingredients. The experiment was conducted in compliance with Article 31, Paragraph 2 of the Enforcement Decree of the Fire Facilities Installation and Management Act and Articles 4 and 7-2 of the Flame Retardant Performance Standards. After flame time, after glow time, char length, and char area were measured. As a result, first, after flame time was measured at 0 seconds regardless of whether the flame retardant treatment was applied. Second, after glow time was relatively long, measuring 22.7 seconds without treatment, which is likely due to the weak fire resistance and high concentration of carbon monoxide generated by the chemical characteristics of the Japanese cypress itself. Third, it was confirmed that the effects of the primary ingredient, phosphorus, in the flame retardant treatment varied depending on the technological development of the manufacturers of the same species of Japanese cypress plywood. In the future, it is expected that the results of this study will provide fundamental data to select flame retardant treatments that show high flame retardant performance according to the botanical characteristics of the wood.