화재 피해를 입은 고 강도 철근콘크리트 휨 부재의 비파괴 검사 (Non destructive test of Fire-damaged reinforced concreted beams with high strength concrete)

  • 신미경;신영수;이차돈;홍성걸;김희선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.651-654
    • /
    • 2003
  • Non-destructive testing is essential in the inspection of alteration, repair and new construction in construction industry. This paper is to evaluate the strength variation of fire damaged concrete by non-destructive testing. Furthermore, It is to infer the recovery degree of residual strength of fire-damaged concrete. For this purpose, researchers are exploring the performance of non-destructive testing method using ultrasonic testing and Schmidt hammer in concrete specimens. Testing is performed four-times: before fire test, directly after fire test, after 20 days and after 60 days.

  • PDF

일반용 전기설비 안전관리의 문제점과 개선방안 (Problems and Improvement Method of Safety Management of Electrical Facilities for General Use)

  • 전정채;전현재;이상익;유재근
    • 한국산학기술학회논문지
    • /
    • 제8권3호
    • /
    • pp.488-495
    • /
    • 2007
  • 일반용 전기설비의 정기적인 전기안전 점검과 부적합 설비의 개선조치에도 불구하고 전기화재의 80% 이상이 일반용 전기설비에서 발생하였으며 전기안전점검제도에 대한 이해부족, 미점검 수용가 증가, 누전차단기 미설치 및 부적합 시설의 방치 등의 원인으로 전기안전사고를 예방하는 것이 더욱 어려워진다. 본 논문에서는 일반용 전기설비의 전기안전점검 제도, 안전점검결과 및 전기화재 통계를 분석하천 관련 문제점을 도출하였다. 또한 전기안전점검제도, 점검업무 수행 방법, 전기화재 통계 수립 및 전기안전의식, 원격전기안전점검 체계 측면에서 일반용 전기설비 안전관리 개선방안을 제시하였다.

  • PDF

콘크리트내에 표면매입 보강된 FRP의 내화성능 향상을 위한 내화단열재 열저항성능 평가 (Evaluation on the Thermal Resistance Capacity of Fire Proof Materials for Improving Fire Resistance of Near-Surface-Mounted FRP in Concrete)

  • 연제영;서수연
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권5호
    • /
    • pp.51-58
    • /
    • 2014
  • 본 연구에서는 철근콘크리트 구조의 FRP를 이용한 보강에서 낮은 내화성능을 개선하기 위한 방안을 찾기 위하여, 보강된 FRP의 외부를 내화보강하는 방법에 대한 내화실험을 실시하였다. 특히 철근콘크리트 부재의 피복에 홈을 형성하여 FRP를 매입하는 보강 즉, NSM 보강을 대상으로 하였다. 실험에서의 주요 변수는 보강방법과 사용 내화재료로서, Perlite계 재료를 표면에 분사하여 보강하는 방법, Calcium silicate계 보드로 표면에 부착하는 방법, 그리고 추가로 홈내부에 Polymer mortar 또는 Calcium silicate조각을 삽입하여 보강하는 방법으로 보강한 뒤 가열로 내부의 온도변화에 따른 열전달을 관찰하였다. 실험결과, Perlite계 내화뿜칠로 표면을 보강하는 경우보다 Calcium Silicate계 내화보드로 표면을 보강하는 방법이 효과적인 것으로 나타났다. 홈 내부의 에폭시가 유리전이온도에 도달할 때의 외부 표면온도 $820^{\circ}C$까지 내화단열성능을 확보할 수 있는 것으로 나타났다.

차동식스포트형열감지기 현장점검용 표준화기기 개발에 관한 연구 (A Study on the Development of Standardization Tester for the Field Inspection of the Rate of Rise Spot Type Heat Detector)

  • 김시국;육현대;양승현;지승욱;이춘하
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.85-92
    • /
    • 2009
  • 본 논문은 차동식스포트형열감지기 현장점검용 표준화기기 개발에 관한 연구이다. 현재 소방점검 시 차동식스포트형열감지기의 성능확인을 위해 사용되는 점검기기(4 Type)들을 실험대상으로 선정하여 문제점을 찾고, 도출된 문제점을 바탕으로 차동식스포트형열감지기 형식승인 시 감도시험기준과 동일한 온도조건인 실온보다 $30^{\circ}C$ 높은 온도로 자동설정 할 수 있고 설정된 온도를 계속 유지할 수 있는 기능과 풍속 조건인 풍속 85cm/s를 유지할 수 있는 차동식스포트형열감지기 현장점검용 표준화기기의 회로를 설계하고 시제품을 제작하였다. 개발된 시제품의 성능확인 결과 차동식스포트형열감지기의 형식승인시험 시 감도시험조건과 동일한 성능이 나타나는 것을 확인하였다.

4M 기법을 활용한 전기화재 예방대책 수립 연구 (A Study on the Establishment of Preventive Measures for Electric Fires Using the 4M Technique)

  • 오택흠;박찬석
    • 대한안전경영과학회지
    • /
    • 제23권4호
    • /
    • pp.23-29
    • /
    • 2021
  • The purpose of this study is to reduce the probability of occurrence of electric fires as a preemptive preventive measure, and to strengthen the capability of preventing electric fires by strengthening the cooperative function between electric fire-related departments and establishing a cooperative system. In this study, the general aspects of electric fires were identified by reviewing the literature such as ignition mechanisms of electric fires. And the major electrical fires that occurred in the last 10 years were classified into ignition factors (short circuit, overload/overcurrent, and earth leakage/ground fault) and ignition sources (wiring/wiring appliances, electrical equipment/household appliances). And the 4M technique was used to analyze the potential causes of ignition at the fire site and to suggest preventive measures. In the case In this study, out of 48 electrical fires in the past 10 years, 16 short-circuit fires, 3 overload/overcurrent fires, 3 short-circuit and earth fault fires, 16 fires in wiring/wiring appliances, and 10 fires in electrical equipment/home appliances classified as cases. And prevention measures were presented in terms of human, machine, media, and management by using the 4M technique. For the preemptive prevention of electric fires, strengthening the compulsory electrical safety inspection and making it mandatory to report when new or expanding electric facilities, charging a fee for electric safety inspection for detached houses and granting benefits subject to inspection completion, improvement of the electric safety voluntary inspection table and safety indications; It was suggested as a policy to organize and operate electrical safety inspection personnel in a two-person team (mixed), establish a close work cooperation system with related organizations, and strengthen electrical safety education and publicity.

소방설비 작동신뢰성 기반 건축용도별 화재리스크 분석에 관한 연구 (A Study on the Analysis of Fire Risk for each Building Usage Based on the Reliability of Operation of Fire Protection System)

  • 진승현;김혜원;서동구;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.113-114
    • /
    • 2020
  • In the design and maintenance of buildings, identifying the degree of damage in the event of a fire is an important factor in fire prevention and fire safety design. In order to predict fire damage, safety measures should be established by predicting the nature of evacuation according to fire, smoke and in-house characteristics, and the effects of the operation of fire safety facilities should also be considered, but in Korea, the risk analysis due to the operation of fire safety facilities is insufficient. Accordingly, this study uses fire statistics and sprinkler inspection data to analyze the degree of fire damage caused by the operation of sprinkler facilities in a probabilistic manner.

  • PDF

재생잔골재를 활용한 화재피해를 입은 콘크리트의 공학적 특성에 관한 실험적 연구 (An Experimental Study on the Engineering Properties of Deteriorated Concrete using Recycled Fine Aggregate by Fire Damage)

  • 권영진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.190-196
    • /
    • 2006
  • 기존 연구에서 살펴보면, 철근콘크리트구조물에 발생한 화재로 인해 경화된 시멘트 페이스트와 골재의 수축과 팽창의 차이에 따라 조직이 와해되고, 열응력에 의해 균열이 발생하여 내구성이 저하한다. 그래서 성능저하의 정확한 진단은 일반적인 콘크리트구조물에서 방화성능저하의 매커니즘에 관한 기초가 요구되며, 고온에 노출된 콘크리트의 특성에 대한 기초 정보와 데이터는 성능저하의 정확한 진단을 위해 필요하다. 따라서, 본 연구는 다양한 콘크리트 시험체를 제작하여, 고온 환경에서 노출시켜, 폭열을 관찰하고, 공학적인 특성을 평가함으로서 화재피해를 입은 콘크리트구조물 성능저하의 빠르고 정확한 진단을 위한 기초적인 데이터를 제공하고자 한다.

변전소 철골 내화뿜칠 부착강도 기준설정에 관한 실험적 연구 (The Experimental Study on the Suggestion for Bond Strength Standard of Sprayed Fire Resistive Materials Used at the Substation Steel Structures)

  • 박동수;정원섭
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권1호
    • /
    • pp.128-137
    • /
    • 2014
  • 내화뿜칠재는 주로 철골구조물 위에 시공하여 내화구조기준을 만족하기 위한 것이다. 국내에서는 원자력발전소를 비롯하여 철골구조물에 내화뿜칠재를 시공하여 왔지만, 재료특성 중 중요한 요건인 부착강도기준이 제정되어있지 않았다. 다만, 원자력발전소는 원전의 기준에 따라 부착강도 기준이 있었다. 본 논문에서는 변전소에 시공되는 내화뿜칠재의 부착강도 기준을 정하고자 하였다. 기준설정 방법은 현재 사용되는 제품으로 실험체를 제작하고, 변전소 환경에 따라 열화시키며 부착강도를 측정하고 구조물 내구연한 기간 동안 열화시킨 후 변전소에서 발생하는 충격하중 실험을 통하여 탈락여부를 평가하여 부착강도기준을 설정하였다. 본 논문에서의 부착강도는 시중에서 사용되는 제품을 기준으로 실험한 것으로 최소한의 값이라고 판단된다.

X-선 형광분석기를 이용한 현장방염검사방법에 관한 연구 (A Study on the On-site Flame Resistant Inspection Method by X-ray Fluorescence Spectrometer)

  • 김황진;이성은
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.124-129
    • /
    • 2016
  • 현행법상 현장방염 처리한 실내장식물은 관할 소방서에서 45도 연소시험을 통해 방염성능검사에 합격하여야 한다. 45도 연소시험법은 방염성능을 확인할 수 있는 가장 정확한 시험법이지만 시료 제출자가 부정시료를 제출하였을 경우에는 시험결과를 신뢰할 수 없다. 따라서 본 논문에서는 이러한 문제를 보완하기 위하여 X-선 형광분석기를 이용한 현장방염 검사방법을 제안하고자 한다. 총 10종의 방염도료를 합판 및 MDF에 처리하여 그 성분을 X-선 형광분석기로 분석한 결과 함유된 물질의 함량 차이로 인해 각 방염제마다 고유의 스펙트럼을 나타내고 있었으며, 측정기기로 손쉽게 각 물질별 함량(%)을 확인할 수 있었다. 따라서 제도적인 절차가 마련된다면 효율적인 현장방염검사방법으로 사용될 수 있을 것으로 기대된다.