A Study about Research on the Actual Condition for Fire Counterplan of Main Temple Wooden Cultural Properties (중요사찰목조문화재의 소방대책을 고려한 실태조사에 관한 연구)

  • Back, Min-Ho;Shin, Ho-Jun
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.121-130
    • /
    • 2009
  • This study is researched about the field trip of temples and the data for fire extinguishment manual of fire stations: it is done from June 2008 to December 2008 the 80 main temple wooden cultural properties among the 124 main wooden cultural properties appointed by the Cultural Heritage Administration. Cultural properties appointment classification, location classification, temple area, building area in a temple, building area of appointment cultural properties, a fire engine drive direction for fire suppression in a fire, distance from a fire station, and present condition of a fire administrator are researched. The cultural properties possess characteristic is in 2 cases: the whole things in a temple are appointed as cultural properties and only the wooden building is. The cultural properties are classified: the transport is possible or not. The special quality of cultural properties are classified for early correspondence and cultural properties transport in a fire and the basic data are arranged for damage limitation.

Fire Safety Administration Way of Tradition Buddhist Temple Cultural Heritage (전통사찰 문화재의 화재안전 관리방안에 관한 고찰)

  • Shin, Min-Seob;Kong, Ha-Sung
    • Journal of Conservation Science
    • /
    • v.23
    • /
    • pp.119-124
    • /
    • 2008
  • Have difficult controversial point to suppress fire effectively by geographical special quality that fire is transmitted and is during the mountain with the fast speed if our country's tradition Buddhist temple makes of most wood and most of construction structure of country importance tradition Buddhist temple are ignited once because combustibility is high as wood. By fire safety supervision improvement way of tradition Buddhist temple cultural heritage in this treatise law and systematic side, Side that is construction room robbers, disaster and prevention of disasters basis system construction and stream tube engine combination check, training courtesy call activity reinforcement present.

  • PDF

The study about fire counter plan through the properties qualities research of the main temple properties in Korea (우리나라 중요사찰문화재의 문화재 보유특성 조사를 통한 화재대응방안에 관한 연구)

  • Shin, Ho-Jun;Jung, Eun-Ji;Lee, Ji-Hyang;Kim, Jung-Ho;Back, Min-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.495-501
    • /
    • 2008
  • This study analyzes into the basic fire counter plan through classifying a kind, material, and transfer of which 66 the main temple properties among 124 the main wooden properties in Korea.

  • PDF

Fire Risk Assessment of Temple Components in Young-dong Areas using Fire Loads (영동지역 사찰의 구성요소별 화재하중을 통한 화재위험성 평가)

  • Lee, Hae-Pyeong;Kim, Su-Young
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.71-75
    • /
    • 2010
  • In this study, we have assessed the fire risk of Buddhist temples located in Youngdong area by means of fire loads of components. First, we categorized the components into Buddhist temples (Dae-Ung-Jeon, Pal-Sang-Jeon), Sam-Seong-Gak (Chil-Seong-Gak, San-Sin-Gak), a Buddhist temple dormitory (Sim-Geom-Dang, Seol-Seon-Dang), Lu, Il-Ju-Mun and then carried out a field survey. Then, we examined the area of each room, types as well as quantity and dimension of combustibles. The fire loads calculated in this way were 446.96 $kg/m^2$ for Buddhist temples, 331.71 $kg/m^2$ for Sam-Seong-Gak, 164.14 $kg/m^2$ for the Buddhist temple dormitory, 463.91 $kg/m^2$ for Lu and 1042.14 $kg/m^2$ for Il-Ju-Mun, thus showing Il-Ju-Mun with the biggest fire load. We speculate that this is because construction materials were similar in size and quantity to others albeit the area of Il-Ju-Mun is smallest.

A Study on the Environment Change of Fire Protection System After Naksan Temple Fire in 2005 year(I) - A Study on the change of Fire Fighting System before and after Naksan Temple fire - (2005년 낙산사 화재 후 소방대책의 환경변화에 관한 조사 연구(I) - 낙산사 화재전후 소방시스템 변화에 관한 조사 -)

  • Koo, Won-Hoi;Jung, Hae-June;Shin, Ho-Joon;Back, Min-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.438-441
    • /
    • 2011
  • 문화재의 경우 국가의 역사를 대변하고 있는 중요한 시설로서 매년 그 중요성이 강조되고 있다. 그럼에도 불구하고 목조 문화재의 화재는 지속적으로 발생하고 있는 것이 현실이다. 이 논문에서는 이러한 점을 반영하여 2005년 낙산사 화재의 개요에 대해 알아보고 낙산사 화재 이후 약 6년간의 낙산사 복구 과정 중에 소방 시스템의 변화에 대해서 분석하고자 한다.

  • PDF

A Study on Fire Risk Assessment of the Temple Using Fire Loads (화재하중을 통한 사찰의 화재 위험성 평가에 관한 연구)

  • Kim, Su-Young;Shin, Young-Ju;Park, Young-Ju;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.409-415
    • /
    • 2008
  • In this study, we considered the fire risk assessment of the temple using fire loads and the classification of combustibles. The building construction materials were classified as walls, beam-columns, floorings, ceiling panels and the loading combustibles were classified into fixed materials and movable materials. As a result, we confirmed that the total fire load of the Palsangjeon was $368\;kg/m^2$. The building construction materials accounted for approximately 93.8 percent of the total fire load and the loading combustibles accounted for approximately 6.2 percent.

  • PDF

A Study on the Environment Change of Fire Protection System After Naksan Temple Fire in 2005 year(II) - A Study on the Influence of Naksan Temple Area and the Change of Disaster Prevention Attitude - (2005년 낙산사 화재 후 소방대책의 환경변화에 관한 조사 연구(II) - 낙산사 주변지역의 영향 및 방재의식 변화에 관한 조사 -)

  • Koo, Won-Hoi;Jung, Hae-June;Shin, Ho-Joon;Back, Min-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.442-445
    • /
    • 2011
  • 2005년 4월 강원도 산불로 인해 낙산사 화재가 발생하여 많은 문화재의 손실이 발생하여 문화재에 대한 소중함과 경각심을 일깨워 주었으며 화재로 인해 발생하는 문화재 손실을 막기 위해 많은 노력이 요구되었다. 본 연구는 강원도 중요 목조문화재인 낙산사 화재 발생 후 6년이 지난 현 지점에서, 주민 방재의식조사를 통해 낙산사 주변지역의 방재의식 변화에 대해 알아보고 이를 바탕으로 문화재 방재대책을 제안하고자 한다.

  • PDF

Biological Damage and Risk Assessment of The Wood Cultural Properties in Fire Prevention Area (화재방제구역에 따른 목조문화재 생물손상 및 생물위험도 평가)

  • Kim, Dae Woon;Chung, Yong Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.1
    • /
    • pp.104-111
    • /
    • 2015
  • The three-year inspection of 20 tree stumps in the fire prevention area around the wooden building confirmed that termite colonies had been rapidly spread. In particular, four buildings among thirty one wooden buildings of Songgwang-sa temple were infected by the termite, indicating that the habitate of termite has been spread across the fire prevention area over the temple area. However, a non-destructive microwave diagnosis showed that internal damages have been progressed until now, suggesting a high risk to the building. These results suggest that the fire prevention area should be properly maintained to have harmful element controlled. Therefore, effective methods are required to eliminate tree stumps or wood materials used to establish fire prevention area near wooden buildings.

Micromorphological Characteristics of Buddhist Temple Woods Treated with Eire-retardant (방염 처리 고목재의 미생물 분해의 미시형태적 특징)

  • Wi, Seung Gon;Kim, Ik-Joo;Park, Young Man;Kim, Yoon Soo
    • 한국문화재보존과학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.27-34
    • /
    • 2001
  • Following the recommendations made by the cultural authorities the wooden cultural properties (WCP) had been treated with fire-retardants for fire protection. However, visual inspections of some of the WCPs treated with fire-retardants showed microbial decay. The work was extended to examine the micromorphological characteristics of the WCPs in a Buddhist temple which had been treated with fire-retardant. Microscopic examination showed the presence of typical soft rot cavities along the length of microfibrils in the secondary wall. Bacterial attack was also observed by scanning and transmission electron microscopy. It is interesting that the decay patterns observed in the Buddhist temple were very similar to those observed in the waterlogged woods. Presumably chemicals in the fire-retardants used rendered the wood susceptible to attack by soft-rot and bacterial decay by causing an increase in the moisture content of wood. Further studies are needed to investigate the effect of fire-retardants used currently on the hygroscopicity and the strength of wood materials in the WCPs. Microbial attacks caused degradation of the secondary cell walls and in some cases also of the middle lamella. In addition, the cell walls in the outer parts of wood were also degraded due to weathering, and cell separation occurred from total disintegration of the middle lamella.

  • PDF