• Title/Summary/Keyword: Fire fighting

Search Result 487, Processing Time 0.025 seconds

The study of basic quality analysis for an effective fire suppression of the main temple properties in Korea (우리나라 중요목조문화재의 효과적 화재진압을 고려한 기본특성분석에 관한 연구)

  • Jung, Eun-Ji;Shin, Ho-Jun;Lee, Ji-Hyang;Kim, Jung-Ho;Back, Min-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.471-478
    • /
    • 2008
  • This study grasps the type and site area of properties, the size of properties, the distance between the wooden properties and fire station, the direction of a fire engine in the wooden properties, the member of self-protection, and the present condition of fire fighting. And the 121 main temples properties in Korea is researched for an effective fire suppression.

  • PDF

Fire Fighting Attachment Development Which Applies a Pipe Remnant (파이프 잔재를 활용한 배관 부속 개발 1)

  • Park, Seon-Yeong;Oh, Jae-hoon;Park, Hyo-Seok;Lee, Chang-Woon;Lee, Jin-Han;Moon, Jong-Wook
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.205-208
    • /
    • 2011
  • 최근 사용하는 소방배관의 현장 시공에 사용되는 공법 및 부속을 살펴보면 정통방식의 부속연결 방식, Tee 가공방식, 분기관 방식을 사용하고 있다. 이 방식 중 가장 많이 사용되고 있는 방식은 Tee가공 방식과 분기관 방식으로 이는 우리나라의 소방배관 시설의 규모로 보았을 때 부속과 공법이 미흡하다 할 수 있다. 기존의 공법은 현장 적용성이 떨어지고 화재안전 성능이 미흡하다 할 수 있으며 사회가 발달 하며 건축물의 형태가 다양해지고 초고층화가 이루어지고 있는 과정에서 본 연구에서는 현재사용 하고 있는 공법의 분석과 새로운 소방배관 부속을 개발 하려 한다.

  • PDF

The Way of operations and tactics for Disaster plan of High-rise Buildings (초고층 건물의 재난 발생 시 작전전술 방안)

  • Lee, Jung-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.3
    • /
    • pp.77-83
    • /
    • 2012
  • Recently, For the most efficient use of spaceis, high-rise buildings tend to increase. So it is with Korea, too. Besides, today high-rise buildings grows due to fire damage to life and property at large. In this study, Through analysis of domestic and foreign fire case and listen to the high-rise building fire managers, tenants, professionals advice, when the fire from the high-rise building, effective fire suppression tactics should we wish to research ways. In addition, we have used the car gondola was installed outside the fire suppression methods in studying. So that fire-fighting is a fire place can be reached quickly, many casualties and property damage, will be reduced.

Current Status of Fire Reduction Policy and Its Policy Impressions (화재저감정책의 현황과 개선과제)

  • Jo, Kwang-Hee;Kim, Sung-Il;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.3
    • /
    • pp.19-25
    • /
    • 2017
  • To minimize and prevent the increasing fire and personal injury, the domestic firefighting organizations are making continuous efforts to strengthen the response system and safety standards. "Fire Reduction Program" has been prepared to reduce the outbreak of fire up to 20% in the next 10 years, and the analysis of fire sources should be done and its countermeasures also should be done accordingly. Therefore, the management status, the improvement tasks, and the limitations of the implementation plan are reviewed and studied so that the implementation and goal of the "Fire Reduction Policy" can be achieved.

A Sensor Module Overcoming Thick Smoke through Investigation of Fire Characteristics (화재 특성 고찰을 통한 농연 극복 센서 모듈)

  • Cho, Min-Young;Shin, Dong-In;Jun, Sewoong
    • The Journal of Korea Robotics Society
    • /
    • v.13 no.4
    • /
    • pp.237-247
    • /
    • 2018
  • In this paper, we describe a sensor module that monitors fire environment by analyzing fire characteristics. We analyzed the smoke characteristics of indoor fire. Six different environments were defined according to the type of smoke and the flame, and the sensors available for each environment were combined. Based on this analysis, the sensors were selected from the perspective of firefighter. The sensor module consists of an RGB camera, an infrared camera and a radar. It is designed with minimum weight to fit on the robot. the enclosure of sensor is designed to protect against the radiant heat of the fire scene. We propose a single camera mode, thermal stereo mode, data fusion mode, and radar mode that can be used depending on the fire scene. Thermal stereo was effectively refined using an image segmentation algorithm, SLIC (Simple Linear Iterative Clustering). In order to reproduce the fire scene, three fire test environments were built and each sensor was verified.

A Characteristics Analysis of Pre-hospital Acute Poisoning in The Elderly

  • Choi, IL-Soon;Kim, Seon-Rye;Cho, Byung-Jun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.8
    • /
    • pp.123-129
    • /
    • 2019
  • This study selected all patients with acute poisoning carried by the 119 emergency services in K-Province from January 1 to December 31, 2015 for complete enumeration. The subjects were 1,627 patients who were classified as poisoning suspected in chemicals and animal/insect poisoning by Rescue Emergency Activity Information System(Emergency Statistics) in fire-fighting portal system of K-province fire-fighting officers. The 119 activity journals were analyzed retrospectively. The major results are as follows. Regarding the demographic characteristics of the elderly and the non-elderly, the most people were unemployed in the elderly group, other job, the non elderly group about their occupations and in both groups, the most people lived in rural areas about their living places. Regarding the poisoning characteristics of the elderly and the non-elderly, the most causing substance was bee sting about the poisoning causing substances and most of patients didn't get drunken about drunken state in both group. Regarding the time factors of the elderly and the non-elderly, both groups had the most accidents in afternoon about the poisoning time and in summer about the seasonal distribution.

Performance Assessment Model for Fire Safety Protection of Office Building (사무소 건축물의 화재안전 성능 평가모델)

  • Yang, Eun-Bum;Hwang, Young-Sam;Lee, Chan-Sik
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.2
    • /
    • pp.69-74
    • /
    • 2004
  • This study is to suggest a performance assessment model for fire safety protection of office building 34 asessment elements were chosen by interviewing with experts, reviewing several codes and existing relevant models, assessment elements included in this model are comprised of five categories which are 'performace of protected area', 'performance of fire partition', 'safety performance of fire escape', 'performace of smoke control system' and 'performace of fire fighting equipment'. The weight of each element was computed by systematic approach like an AHP (analytical hierarchy process), which was conducted by experts who work in the field of fire protection. This model would be utilized as a part of assessment model for the overall performace of domestic office building.

A Study on the Safe Position from the Local Fire in the Ship's Engine Rooms

  • Kim, Mann-Eun;Lee, Kyoung-Woo;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.446-454
    • /
    • 2008
  • Control devices for fire safety systems located in a engine room are to be arranged at a safe position which is easily accessible during a fire. To develop an interpretation for the safe position in engine rooms, calculation and experiments are carried out to determine a correlation between radiant heat and distance from fire in this paper. On the basis of results of this research, the control devices for a main engine are to be installed in the behind side of an obstruction to reduce radiant heat from the fire of the main engine. In case of other control devices, they are also to be provided in the same manner of control devices for the main engine or are to be placed with 5 meters far from fire hazards.

Strength Characteristic and Phenomenon of Heated Concrete by High Temperature (고온가열 콘크리트의 강도 특성과 현상)

  • 태순호;이병곤
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.3
    • /
    • pp.132-138
    • /
    • 1997
  • For many years concrete has been the major building material for most construction. It is of primary importance that fire fighters or fire investigators have a full understanding of the properties of concrete so that better control of the fire scene is achieved. This, in turn, not only help to ensure a safer fire-fighting job but also a more successful fire investigation. So far as the fire scene investigation in concerned, knowledge about the thermal behaviour of concrete can help the investigators to determine the highest temperature that a particular spot of a fire scene has ever reached thereby providing data which may be of value in reconstructing the course of the fire.

  • PDF

Analysis of Performance and Development of Environment-friendly High Expansion Foam Concentrate (친환경 고발포 소화약제 개발 및 성능 분석 연구)

  • Kim, Ha-Young;Nam, Jun-Seok;Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.4
    • /
    • pp.25-29
    • /
    • 2010
  • Foam concentrate is used for fire-extinguishing purposes, occurring foam, mixed with air. In huge oil-fire or the efficiency of fire-extinguishing with small quantity of water, Foam concentrate is used widely. However, perfluorooc tanoicsulfonate and nonylpenol that are included in Foam concentrate could be exposure in danger while they were discharged. The purpose of the research is the development of environment-friendly high expansion foam that exclude the dangerous substances and improvement of danger of the existing foam concentrate. The developed foam is analyzed as the environment-friendly foam in indexes of the environment-toxicity, the biodegradation appraisal, and the dangerous substances-detecting. In addition, the performances of expansion rate, discharge rate, and fire-extinguishing are suitable in the domestic regulation, so it is useful for fire-extinguishing in real fire situation.