• Title/Summary/Keyword: Fire facilities

Search Result 835, Processing Time 0.034 seconds

A Study on The Improvement of the Leagal Study on Special Fire Safety Inspection System (법과 제도적 관점에서 본 소방특별조사의 개선방안)

  • Lee, Jae Wook;Jeong, Gi Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.545-552
    • /
    • 2021
  • Under the Act amended on August 4, 2011, a special fire-fighting investigation was conducted by the relevant person (owner, manager, oil refineries), and the responsibility was also given to the relevant person. Instead of directly entering all existing fire-fighting targets and investigating the maintenance and management status of fire-fighting facilities, the fire-fighting agency selects and visits some targets every year, checks the maintenance and management status of fire-fighting facilities, corrects them, and imposes fines, etc. Reasons for the introduction of the system were the establishment of a private autonomous correction system by strengthening the responsibility of officials, lack of firefighting professionals, possible corruption due to frequent public contact, and responsibility of fire agencies. However, many problems arose even after the introduction of a special fire investigation system. A special fire investigation, one of the fire safety systems, checks whether related public officials and especially fire officials are properly installed, maintained and managed in accordance with relevant laws. Special firefighting investigations were introduced as firefighting inspections at the time the firefighting law was enacted in 1958, and have undergone a revised process more than 30 times until recently. Firefighting Facility Installation, Maintenance and Safety Management Act", the existing firefighting inspection was changed to a special firefighting investigation and accepted. At the time of enactment of the Fire Service Act in 1958, a special firefighting investigation was introduced as a firefighting inspection, and until recently, more than 30 revisions have been made. In 2003, as the existing fire fighting system was divided into four laws, it was approved by changing the existing fire fighting inspection to a special fire fighting investigation in the "Fire Fighting Facility Installation, Maintenance and Safety Management Act".

Effect of Preventive and Prepared Fire Administration on Response Fire Administration (예방소방행정과 대비소방행정이 대응소방행정에 미치는 영향)

  • Lee, Wonjoo;Lim, Jae Hoon;Moon, Kwang Min
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.120-130
    • /
    • 2020
  • This study aimed to provide an empirical analysis of the effect of preventive fire administration (PVFA) and prepared fire administration (PPFA) on response fire administration (RPFA) in fire service organizations in Korea. To this end, panel data was collected from 16 metropolitan councils from the period of 2008 to 2018 and statistically analyzed using PVFA, PPFA, and RPFA. The independent variables were PVFA and PPFA, while the dependent variable was RPFA. The analysis of the current situation of the specific target for firefighting (STFF), public use facilities, proof of completion of safety families for public use facilities, and special fire inspection were sub-variables of PVFA. Fire safety education (FSE) and the mobilization for fire suppression (MFS) were sub-variables of PPFA and RPFA, respectively. In the results, STFF and FSE had a significant positive influence on the MFS. This study will contribute to the basic research regarding the investigation of the effectivity of fire service organizations in Korea.

Fire Risk Assessment of Building Use Types Using Natural Breaks (Jenks) (자연적 구분법을 이용한 건축물 용도별 화재위험도 평가)

  • Lee, Kyu Min;Lim, Hyeon Seok;Cho, Jae Woo;Lee, Sang Kwon;Min, Se Hong;Min, Jeong Ki
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.63-71
    • /
    • 2019
  • This study quantitatively analyzed the fire risk of buildings by use nationwide, fire occurrence, and the statistical data of buildings by use. Fire incidents and buildings' statistics from the past 10 years (2008-2017) were used and classified as "Building Laws" and "Enforcement Decree of the Act on the Installation, Maintenance, and Safety of Fire Facilities" to be used for the relative assessment under the Natural Breaks as a risk matrix. In addition, after conducting risk assessment using 2018 fire occurrence data, we compared and analyzed the same with past 10 years' data. The results showed that most facilities had similar risk grades, except for the results of reduced risk levels from IV to II in recreational facilities, confirming the past and present data correlations as valid. Hence, the classification method is deemed appropriate. Through the results, the fire risk assessment of buildings by use nationwide are presented as a reference for fire safety.

A Study on the Influence of Fire Service Budget for Fire Service Force (소방예산이 소방력에 미치는 영향)

  • Kim, Jin-Dong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.67-74
    • /
    • 2008
  • Because the fire service demands are increasing and forms are diversified, the first thing you must do is to make up the fire service budget to keep fire service power sufficiently. Such budget allocation leads to supply enough fire service people want and results in social welfare satisfaction. If the budget of fire service is not enough to meet with its power, sufficient security of the fire fighters would be impossible. Also, when the urgent disasters occur, the government cannot cope with them effectively. In fact, loss of many lives and properties took place in some cities and kuns because of that. The purpose of this study is to investigate the influence of fire service budget for fire service force. To do this, this study reviews fire service budget, fire service force. And this study sets up three hypotheses based on the theoretical backgrounds and the past research. The statistical method used for the verification of hypotheses is multiple regression analysis. The analysis showed that fire service budget per head variable was positive significant, fire service budget ratio variable was not significant. Also, public facilities tax variable was negative significant. Therefore, the analysis showed that public facilities tax couldn't fill the role as a earmarked tax.

A Study on the Improvement of Life Safety Code for Logistics Warehouse Facilities (물류창고 시설의 인명안전기준 개선 방안에 관한 연구)

  • Kim, Yun-Seong;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.98-99
    • /
    • 2021
  • The number of fires in the Korean distribution warehouse increased by about 350 from 1,070 in 2014 to 1,416 in 2020. In addition, the fire load increases with the scale of the distribution warehouse, and even if the automatic sprinkler operates, there is a limit to the direct intrusion of the water source into the ignition source, and the detector is often installed on a high ceiling. The sensing time is often delayed. In order to improve the fire safety of such distribution warehouses, the US NFPA stipulates in detail the contents related to the facility, such as sprinkler water discharge standards, rack-type warehouse installation height restrictions, and regulations on collection and equipment. However, in Japan, the goods loaded inside the distribution warehouse are not classified in detail, and it is considered that the fire safety for the distribution warehouse is low due to the relaxation regulations of the fire prevention section. Therefore, in this study, common problems are classified into material, spatial, and safety management characteristics through the cases of distribution warehouse fires that occurred in Korea and abroad, and the problems related to distribution warehouses in Korea and abroad are compared and analyzed. And present basic materials for improving the life safety standards of future distribution warehouse facilities.

  • PDF

Review on the detailed standards for Quantitative Risk Analysis in High Speed Railway Tunnels (고속철도 터널의 정량적 위험도 분석(QRA)을 위한 세부기준에 관한 고찰)

  • Choi, Won-Il;Choi, Jeong-Hwan;Moon, Yeon-Oh;Kim, Seon-Hong;Yoo, Ho-Sik
    • Tunnel and Underground Space
    • /
    • v.18 no.6
    • /
    • pp.393-407
    • /
    • 2008
  • To protection of fire accident and to minimize danger of spreading the disaster. in railway tunnel, MCT (the Ministry of Construction and Transportation) published "Rules about the Safety Standard of Railroad (2005.10.27)" and "The Detailed Safety Standard of Railroad (2006.9.22)". QRA(Quantitative Risk Analysis) results are applied to establish the fire protection facilities in railway tunnel so that institute the reasonable application about the fire safety facilities However, it is difficult to perform the fire safety design due to lack of the detailed standards about event scenario, fire intensity, incidence rate of accidents etc. Therefore, This paper introduces the practical method about detailed standards of QRA.

대규모건축물적용 특수방재설비

  • 이성모
    • Fire Science and Engineering
    • /
    • v.10 no.4
    • /
    • pp.37-42
    • /
    • 1996
  • The "Intelligent Fire detecting and Extinguishing System" is an up-to-date fire protection system for modern high-rise buildings, international airports, enormous industrial facilities, dome stadiums such as specific areas in which the application of our local fire protection regulation could not be satisfied. The state-of-the art initiating devices communicated with sophisticated network control panels enable peoples to get reliable and powerful suppressions using water or gas, providing absolute protection. The Intelligent Water Cannon System, the Low Pressure $CO_2$ System and the MXL Networking Fire Alarm System introduced in this paper accomplish the dynamic protection for the special hazards.

  • PDF

Improvement Method of Hazardous Materials Facilities Installation License of Manufacturer (위험물시설의 설치허가제도의 개선방안)

  • 이종영;이수경;김태환
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.21-35
    • /
    • 2001
  • By rearing private experts to design hazardous facilities, Safety property is obstained. So it is necessary to limit within the designer of hazardous materials facilities who has some degree skill. After permission progress about the inspection of the design ascertain whether it is safety property Mayor/Do governor permits within the laws and their qualification. Accordingly, Korea Fire Equipment Inspection Corporation be come specialization about the design, inspection of construction completion. A inquire purpose of Fire Service Act be considered fitness. Subject by which the Korea Fire Equipment Inspection Corporation is entrusted, subject by which the a non-probit corporation in The Civil Law be possible to entrusted in separate. In this case, because of the level of one's technique and facilities are important, to limit as a nonprobit corporation in The Civil Law give rise to trouble. Consequently; established a business corporation, which the level of one's technique and facilities, in accordance with The Commercial Law can assign inspection of construction completion. The contents of the Fire Services Act is caused by the historic growth of hazardous facilities's safety management. Because we decide on a course about completed inspection of hazardous substance, it is needed that adjust the task performed by a corporation of the exert skill and the duty performed by the task that a authorized corporation on the civil law or the commercial law To adjust the duty, the Fire Service Act, that is suitable to the purpose and principle, should constitute a measure of the duty. With the object of insure the safety of the hazardous substance, when the fire survice act establish a corporation of the expert skill. There is the will of lawmakers that need organization to have the power of the professional technology. The state excise the will that insure the safety of hazardous materials facilities on the basis of the professional technology and facilities, and construct to establish a corporation of the expert skill. Therefore as concentrate on the technology to need to insure the safety of the facilities of hazardous substance to be suitable on the purpose of laws and take responsibility and reports to a corporation of the expert skill. The task to be given to the state will be done.

  • PDF

A Study on the Fire Prevention Activities and Suppression Measures of Utility-Pipe Conduit (지하공동구 화재예방활동 및 진압대책에 관한 연구)

  • Lee, Jung-Il
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.4
    • /
    • pp.63-68
    • /
    • 2010
  • Utility-Pipe Conduit is, Housing and city effectively accommodate what they absolutely need power, communications, gas, pipeline, water supply, drainage, energy facilities etc, according to expansion of urban infrastructure are derived, several ways to solve problems in, collection facilities in place are maintained and managed facility. If Utility-Pipe Conduit is damaged, as well as national security, because their impact on society as a whole, by introducing large vulnerability in the fire prevention activities and suppression measures and disaster for our situation by introducing measures, comprehensive analysis of the fire risk, it shall establish fire prevention activities and suppression through analysis of Utility-Pipe Conduit design, institutional issues, the problem of fire protection facilities, fire spread phenomenon etc. Because of Utility-Pipe Conduit is an enclosed place, so incomplete combustion due to lack of oxygen supply that there are problem such dark smoke, carbon monoxide etc, toxic combustion products and heat generation and visual impairment is an issue difficult to enter. As well as fire prevention activities, the fire In light of the particularity of the under ground than above ground fire, so this phenomenon is weak fire fighting that fire to become effective fire fighting tactics, basically it is necessary difficulty softening, non-burn softening and prevent combustion expansion of the cable is installed on the Utility-Pipe Conduit, having to considering the specificity of the response command system and relevant organizations to establish an on-site, Structural identification and other information gathering required to record of Response agencies, keep air conditioning system 24 hours and strengthening Virtual Total Training of Response agen

Experiments on Egress of Persons with Mobile Disability in Train Car (철도차량 화재 시 지체 장애인 피난 실험)

  • Kim, Jong-Hoon;Kim, Woon-Hyung;Roh, Sam-Kew;Lee, Duck-Hee;Jung, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1673-1679
    • /
    • 2009
  • Korean railroad company is continuously improving the service for the disabled. They also install and reform many facilities for them. However, They didn't consider the egress of the disabled when fire occurred until today. At present, fire hazard analysis and risk assessment are introduced into Korea regulation for improving fire safety performance of train car and railroad facilities. Fire safety evaluation for the railroad conducted in Korea didn't generally consider the disabled. In the present situation, the study for the egress of the disabled in train car was needed. The egress experiment was conducted to measure the movement speed of the disabled who didn't walk or walk very slow.

  • PDF