• 제목/요약/키워드: Fire exposure

검색결과 268건 처리시간 0.026초

A development of video-complex remote monitoring system for offshore plant (영상복합형 해양플랜트 원격 관제 시스템 개발)

  • Kim, Hun-Ki;Hwang, Hun-Gyu;Yoo, Gang-Ju;Lee, Jang-Se;Park, Hyu-Chan;Shin, Ok-Keun;Lee, Seong-Dae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권1호
    • /
    • pp.56-63
    • /
    • 2014
  • An offshore plant needs costly maintenance and has difficulty coping with various accidents coming from the exposure to the environmental threats such as typhoons, tidal waves and etc., in addition to the artificial ones such as fire, collision of ships and etc. In this paper, we develop the video-complex remote monitoring system for an offshore plant, using AtoN AIS and multi-stage database to monitor an offshore plant and solve those problems. The system handles real time video cameras to collect and monitor images on an offshore plant. So, users can be exactly and quickly aware of the information on various situations with the monitoring application based on ENC.

Design Study for the Improvement of Storage Space in the Problem of Domestic Ambulances (국내 구급차 내 수납공간의 문제점과 개선방안을 위한 디자인 연구)

  • Shin, Dong-Min;Kim, Seung-Yong;Hann, Boong-Gi;Han, Yong-Taek
    • Journal of the Korean Society of Safety
    • /
    • 제30권1호
    • /
    • pp.79-86
    • /
    • 2015
  • This research proposed a design direction for the ambulance interior storage space based on the placement and access to the equipment to facilitate an emergency medical practice taking into account the safety and efficiency by the emergency medical technician ergonomic factors. Therefore, through a field survey for the current derivation of the storage space problem 'placement', 'enable', 'management' like these three items resulting clarity, accessibility, simplicity and functionality of the four functional elements by targeting ambulances in operation in this country. First, there is a need to improve standardized of cabinet sizes fit to loaded meet emergency equipment standards. Currently, the equipment designed to use a simple storage cabinet has had problems in the usability. Second, it must be located in the continuous exposure in progress to the user's traffic line. Third, the problem was the insufficient function of the cabinet to ensure the safety of patients by paramedics from the emergency rescue equipment and due to the leaning of the ambulance driving. Besides, it was pointed out that in addition to the proposed alternatives, including the agenda, states that safety belt replacement equipment, emergency personnel and patients with the handle of a guardian for the efficient use storage space within the 119 ambulance. However, in the present study suggest that there is a state proceeds mainly limited usability in the field, having been installed.

Implementation of Film Type Sensor for Synthetic Lube Oil and High Pressure Hydraulic Fluid Leak Detection (합성 윤활유 및 고압 작동유 누출감지 필름형 센서의 구현)

  • Park, No-Jin;Yu, Dong-Kuen;Yu, Hong-Kuen
    • Journal of Sensor Science and Technology
    • /
    • 제23권4호
    • /
    • pp.266-271
    • /
    • 2014
  • Chemical sensors are used in various industrial facilities such high-risk and prevent the leakage of substances, important in life and environmental protection and the safe use of industry, used for management. In particular, high-temperature environments such as power generation equipment of the rotating part due to leakage generated by the various oil, power plants Shut Down, fire, work environment (exposure to various chemical solution and gas leak) and various water, air and soil pollution causes. Thus, over the long term through various channels such as crops and groundwater contamination caused by the slow, serious adverse effect on the ecosystem. In this paper, synthetic lube oil and high pressure hydraulic fluid leakage and immediately detect a new Printed Electronic implementation of technology-based film-type sensors, and its performance test. Thus, industrial accidents and environmental pollution and for early detection of problems, large accidents can be prevented. Experimental results of the synthetic lube oil and high pressure hydraulic fluid solution after the contact time depending on the experiment and the oil solution of the sensor material of the conductive porous PE resistance value by a chemical reaction could be confirmed that rapid increase. Also implemented in the film-type oil sensor electrical resistance change over time of the reaction rate and the synthetic lube oil is about 2 minutes or less, the high pressure hydraulic fluid is less than about 1 minute was. Therefore, more high-pressure hydraulic fluid such as a low volatility synthetic lube oils are the resistance change and the reaction rate was confirmed to be the slowest.

Impact Characteristics of CFRP Structural Member according to the Variation of Stacking Condition and Impact Energy (적층구성과 충돌에너지의 변화에 따른 CFRP 구조부재의 충격특성)

  • Yeo, In-Goo;Choi, Ju-Ho;Choi, Yeong-Min;Yang, Yong-Jun;Hwang, Woo-Chae;Yang, In-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • 제22권6호
    • /
    • pp.976-981
    • /
    • 2013
  • This aims to examine experimentally the absorption behavior and strength of circular CFRP members with different stacking configurations on exposure to a separate impact velocity. In addition, considered the dynamic characteristics. Circular and square CFRP members were prepared from 8-ply unidirectional prepreg sheets stacked at different angles ($0^{\circ}/90^{\circ}$ and $90^{\circ}/0^{\circ}$, where the $0^{\circ}$ direction coincides with the axis of the member) and interface numbers (2, 4, and 6). Based on the collapse characteristics of the circular CFRP members. In this study, for the circular members, the impact energies at crosshead speeds of 5.52 m/s, 5.14 m/s, and 4.57 m/s are 611.52 J, 529.2 J, and 419.44 J (at circular members), respectively. Likewise, for the square members, the impact energies at crosshead speeds of 2.16 m/s, 1.85 m/s, and 1.67 m/s are 372.4 J, 274.4 J, and 223.44 J (at square members).

Optimal Allocation Heuristic Method of Military Engineering Equipments during Artillery Position Construction Operation (휴리스틱 기법을 이용한 포병진지 구축작전시 공병장비 최적배정)

  • Park, Se Hwan;Lee, Moon Gul
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • 제40권1호
    • /
    • pp.11-21
    • /
    • 2017
  • Artillery fire power due to effectiveness which is hard to predict well-planned and surprising attack can give a fear and shock to the personnel and is a very core weapon system and takes a critical role in wartime. Therefore in order to maximize operational effectiveness, Army required protecting artillery and takes a quick attack action through rapid construction of artillery's positions. The artillery use artillery's position to prevent exposure by moving to other position frequently. They have to move and construct at new artillery's positions quickly against exposing existed place by foe's recognition. These positions should be built by not manpower but engineering construction equipment. Because artillery positions have to protect human and artillery equipment well and build quickly. Military engineering battalion have lots of construction equipment which include excavator, loader, dozer, combat multi-purposed excavator, armored combat earthmover dump truck and so on. So they have to decide to optimal number of Team combining these equipments and determine construction sequence of artillery's position in operational plan. In this research, we propose to decide number of Team efficiently and allocate required construction's positions for each Team under constraints of limited equipments and time. To do so, we develop efficient heuristic method which can give near optimal solution and be applied to various situation including commander's intention, artillery position's priority or grouping etc. This heuristic can support quick and flexible construction plan of artillery positions not only for using various composition's equipment to organize Teams but also for changing quantity of positions.

A Survey and Recommendation on Safety and Health for Occupational Health Laboratories (일부 산업보건관련 기관의 분석실험실 안전보건에 관한 실태와 대책)

  • Yoo, Ke-Mook;Roh, Young-Man;Han, Jin-Gu;Won, Jung-IL
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • 제10권2호
    • /
    • pp.150-164
    • /
    • 2000
  • This study was conducted at occupational health laboratories in Seoul and Gyunggi district area from December, 1999 to January, 2000. The main purpose of this study was to survey the actual condition of safety and health by questionnaire and checklist and to assess the performance of fume hoods and the airborne exposures to chemicals in the laboratories. The chemicals in the cabinet were not classified by hazardous properties and the compressed gases were not stored safely. The prevalences of laboratories having first aid kits, fire extinguishers, and safety showers were found to be 18%, 55%, and 9%, respectively. Most laboratory workers were not educated for safety and health. Also, there was no performance evaluation for hazards and risks. The fume hoods in laboratories had not been annually inspected by checklist and the face velocity had been checked more than one time in the previous year for only 18% of them. Five percent of fume hoods had the face velocity more than 4.0 m/sec and 17% had no capture performance. Detected organic solvents were methylenechloride, acetone, ethylbenzene, isopropanol, xylene, methylisobutylketone, trichloroethylene, and toluene. The concentrations of organic solvents were much less than the occupational exposure limits proposed by the Ministry of Labor in Korea. This study showed that the actual condition of safety and health was not appropriate for laboratory workers. It is recommended that laboratory workers should be educated for the treatment and storage of hazardous chemicals and compressed gases to improve the working environment of the occupational safety and health laboratories.

  • PDF

The Framework of Aeronautical Information System for Volcanic Ash Hazard Management (화산재대응시스템을 위한 항공교통정보 프레임워크)

  • Nam, Doohee;Lee, Jinsun;Lee, Sangsoo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • 제16권1호
    • /
    • pp.166-175
    • /
    • 2017
  • Hazardous volcanic activity will continue to occur in the ring of fire, a major area in the basin of the Pacific Ocean where a large number of earthquakes and volcanic eruptions occur. and, because of rising populations, development pressures, and expanding national and international air traffic over volcanic regions, risks to life and property through exposure to volcano hazards continue to increase. During an eruption, volcanic contamination can reach and exceed the cruising altitudes of turbine-powered aircraft, among others, within minutes and spread over vast geographical areas within a few days. Volcanic ash can affect the operation of aircraft at aerodromes. Volcanic ash deposition at an aerodrome, even in very small amounts, can result in the closure of the aerodrome until all the deposited ash has been removed. In this study, air traffic information framework is presented along with algorithms to define affected routes, waypoints and airports using GIS geometry analysis.

A Study on Workers Exposed to Diatomaceous Earth Dust and Development of Pneumoconiosis in a Diatomite Factory (모 규조토 가공 업체의 규조토 분진 폭로에 의한 규조토폐증 유병에 관한 조사)

  • Lim, Hyun-Sul;Kim, Sung-Soon;Lee, Won-Jae
    • Journal of Preventive Medicine and Public Health
    • /
    • 제28권1호
    • /
    • pp.1-12
    • /
    • 1995
  • Diatomaceous earth, quarried from the remains of aquatic plants deposited millions of years ago, continues to be a very important raw material with many industrial uses. In its natural state, diatomaceous earth is an amorphous silica with no crystalline pattern. For many uses, however, it is calcinated and calcination converts a portion of the amorphous silica to a crystalline form, cristobalite which is far more fibrogenic. In a factory which produces calcinated diatomaceous earth, seven workers were proved as pneumoconiosis on 1991 and 1992. Authors reviewed medical chart and current status of them. Authors also examined thirty one subjects from the factory with questionnaire, physical examination, spirometry and chest radiography on August 13th 1993. The radiographs were independently interpreted by two radiologists and their findings were classified by International Classification of Radiography of Pneumoconiosis(ILO, 1980). Total and respirable dust of diatomaceous earth were measured on October 1993. The results were as follows; 1. Of 31 workers, 6 (19.4%) were diagnosed as diatomaceous earth pneumoconiosis. There was an increasing tendency in prevalence of pneumoconiosis as the duration of dust exposure gets longer. 2. There were no significant differences in age, smoking rate, alcohol drinking rate, and pulmonary function test results between cases and non-cases. 3. The means of total dust exposures at flour manufacturing, fire brick grinding and packaging, ceramic raws packaging processes exceeded Korean and ACGIH standards, $10mg/m^3$. Above results suggest that engineering controls, periodic environmental and medical surveillance are important for preventing pneumoconiosis in the diatomite factory.

  • PDF

Performance Evaluation of High Strength Concrete with Composite Fibers in Accordance with High Temperature (복합섬유가 혼입된 고강도 콘크리트의 고온가열에 따른 성능 평가)

  • Kim, Seung-Ki;Kim, Woo-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제19권6호
    • /
    • pp.63-71
    • /
    • 2015
  • The objective of the present study is to investigate how elevated temperature ranging from $100^{\circ}C$ to $800^{\circ}C$ as well as room temperature affects the variation of mechanical properties of high strength concrete ($over\;f_{ck}=60MPa\;grade$). In this experiment, specimens were exposed for a period of $2^{\circ}C/min$ to temperatures of $20^{\circ}C$, $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$ $400^{\circ}C$, $500^{\circ}C$, $600^{\circ}C$, $700^{\circ}C$ and $800^{\circ}C$, respectively. Accordingly, the study investigated the fire resistance performance of high strength concrete mixed with composite fibers which composed with hybrid fibers and steel fibers. After cooling down to ambient temperature, the following basic mechanical properties were then evaluated and compared with reference values obtained prior to thermal exposure: (i) compressive strength in room temperature; (ii) residual compressive strength; (iii) Poisson's ratio; (iv) weight change; (v) SEM analysis & XRD analysis In addition, XRD and SEM Images analyses were performed to investigate chemical and physical characteristics of high strength concrete with composite fibers according to high temperature.

The Effect of Resilience on Posttraumatic Stress Disorder Symptoms and Comorbid Symptoms in Firefighters (강원지역 소방관에서 외상후 스트레스 증상 및 동반증상에 미치는 리질리언스의 영향)

  • Lee, Hong-Eui;Kang, Suk-Hoon;Ye, Byoung Seok;Choi, Jong-Hyuck
    • Anxiety and mood
    • /
    • 제8권2호
    • /
    • pp.86-92
    • /
    • 2012
  • Objective : This study investigated the relationship between the resilience and posttraumatic stress symptoms, as well as comorbid symptoms in firefighters. Methods : We collected 764 firefighters, who worked at six fire department stations in Gangwon-do. We investigated the impact of event scale-revised (IES-R), the life events checklists (LEC), Connor-Davidson resilience scale (CD-RISC), Beck depression inventory (BDI), state trait anxiety inventory (STAI) and alcohol use disorder identification test (AUDIT). Full PTSD groups, partial PTSD groups and non-PTSD groups, which were classified by IES-R scores, were compared in the LEC, CD-RISC, BDI, STAI and AUDIT, ; multiple linear regression analyses were done for independent predictors of variables. Results : Of the 764 firefighters, there were significant differences in LEC (p<0.001), CD-RISC (p<0.001), BDI (p<0.001), and AUDIT (p=0.001) among the full PTSD groups, partial PTSD groups and non-PTSD groups. However, STAI did not show significant difference among three groups. In multiple regression analysis, CD-RISC (${\beta}=-0.168$, p<0.001), LEC (${\beta}=0.211$, p<0.001) and AUDIT (${\beta}=0.115$, p=0.001) were significant predictors for IES-R. Conclusion : The results of the present study suggested that resilience might be a protective factor in PTSD and comorbid symptoms of PTSD.